• 제목/요약/키워드: Criteria pollutants

검색결과 161건 처리시간 0.02초

서울.수도권 지역 주요 대기오염물질 배출원 자료 현황 분석 (Analysis of the Present State of Air Pollutant Emission Data for the Greater Seoul Area)

  • 김진영;김영성;김용표
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.813-826
    • /
    • 1999
  • To understand the present status of air pollutant emission data for the greater Seoul area, existing air pollutant emission data were analyzed and compared. For the criteria pollutants, estimation methods of emissions from point, line, and area sources adopted in the previous studies were analyzed and their results were compared. Two sets of VOC emission estimation were also compared and analyzed. There exists a large discrepancy among previous emission data due to the differences in the scope of emission sources and the estimation method including emission factors employed in each estimation. Applications of previous air pollutant emission studies for air quality modeling and related problems were discussed.

  • PDF

농림생태계와 대기간의 상호 작용 연구를 위한 에디 공분산 방법의 사용에 관하여 (On Using the Eddy Covariance Method to Study the Interaction between Agro-Forest Ecosystems and the Atmosphere)

  • 최태진;김준;윤진일
    • 한국농림기상학회지
    • /
    • 제1권1호
    • /
    • pp.60-71
    • /
    • 1999
  • The micrometeorological tower flux network is the cornerstone of the global terrestrial vegetation monitoring. The eddy covariance technique used for tower fluxes is derived from the conservation of mass and is most applicable for steady-state conditions over flat, extended, and uniform vegetation. This technique allows us to obtain surface fluxes of energy budget components, greenhouse and trace gases, and other pollutants. The quality-controlled flux data are invaluable to validate various models with temporal scales ranging from minutes to years and spatial scales ranging from a few meters to hundreds of kilometers. In this paper, we review the theoretical background of this important eddy covariance technique, examine the measurement criteria and corrections, and finally suggest some measurement strategies that may facilitate coordinated flux measurements among different disciplines and provide a strong infrastructure for the global flux network.

  • PDF

국내 지하수 수질관리체계 개선을 위한 유럽 지하수 문턱값 비교 (Comparative Study of Groundwater Threshold Values in European Commission and Member States for Improving Management of Groundwater Quality in Korea)

  • 남선화;이우미;정승우;김혜진;김현구;김태승;안윤주
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권3호
    • /
    • pp.23-32
    • /
    • 2013
  • Korean groundwater quality standards were established in 1994, and revised in 2003 and 2010. The substances for which standards have been developed are classified into two groups, general pollutants, 4, and specific pollutants, 15. The standards have been applied to household water use, agriculture, aquaculture, and industrial use. However, there is no systematic methodology for either selecting candidate substances or establishing groundwater standards. We investigated various derivation methodologies for groundwater standards used by the European Commission and 27 member states and compared their methods for determining threshold values. The European Commission presented to their member states groundwater standards for two substances and a list of required substances for derivation of threshold values along with the member states. Interestingly, they first considered national background levels and then considered other criteria for water protection, such as drinking water standards, environmental quality standards, and irrigation standards. We suggest that Korean background levels in groundwater should be included in the methodology for establishing groundwater quality standards. These results may be useful in developing a systematic methodology for establishing Korean groundwater quality standards.

Size Distribution Characteristics of Particulate Mass and Ion Components at Gosan, Korea from 2002 to 2003

  • Han J.S.;Moon K.J.;Lee S.J.;Kim J.E.;Kim Y.J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제21권E1호
    • /
    • pp.23-35
    • /
    • 2005
  • Size distribution of particulate water-soluble ion components was measured at Gosan, Korea using a micro-orifice uniform deposit impactor (MOUDI). Sulfate, ammonium, and nitrate showed peaks in three size ranges; Sulfate and ammonium were of dominant species measured in the fine mode ($D_{p} < 1.8 {\mu}m$). One peak was observed in the condensation mode ($0.218\sim0.532{\mu}m$), and the other peak was obtained in the droplet mode ($0.532\sim1.8{\mu}m$). Considering the fact that the equivalent ratios of ammonium to sulfate ranged from 0.5 to 1.0 in these size ranges, it is inferred that they formed sufficiently neutralized compounds such as ($NH_{4})_{2}SO_{4} and (NH_{4})_{3}H(SO_{4})_{2}$ during the long-range transport of anthropogenic pollutants. On the other hand, nitrate was distributed mainly in the coarse mode ($3.1\sim6.2{\mu}m$) combined with soil and sea salt. Two sets of MOUDI samples were collected in each season. One sample was collected when the concentrations of criteria air pollutants were relatively high, but the other represented relatively clean air quality. The concentrations of sulfate and ammonium particles in droplet mode were the highest in winter and the lowest in summer. When the air quality was bad, the increase of nitrate was observed in the condensation mode ($0.218\sim0.282{\mu}m$). It thus suggests that the nitrate particles were produced through gas phase reaction of nitric acid with ammonia. Chloride depletion was remarkably high in summer due to the high temperature and relative humidity.

실내공기질에 따른 재실자의 인식성 공기질 평가 (Perceived Air Quality Assessment of Occupants According to Indoor Air Quality)

  • 우병렬;이현수;안호기;정순원;황문영;박충희;유승도;양원호
    • 한국환경과학회지
    • /
    • 제20권1호
    • /
    • pp.61-69
    • /
    • 2011
  • Perceived air quality (PAQ) is defined as evaluation of indoor air satisfaction and comfortable sensory by occupants. However, there are differences between criteria of indoor pollutants and lowest sensory thresholds. In this study, we compared indoor PAQ by questionnaire with measured benzene, toluene and nitrogen dioxide ($NO_2$) concentrations in home indoors. The $NO_2$ concentration was the highest in Seoul, while benzene and toluene were the highest in Asan. Average PAQ score in winter was higher than that in summer. Significant correlations between PAQs of home indoor air pollution and measured pollutant concentrations were not shown and correlation coefficients (r) ranged between -0.453

서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성 (Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

최적화 모델을 이용한 경제적인 총량관리 할당기법 연구 (The Allocation Methods for Economical Efficiency Using an Optimized Model)

  • 최인욱;신동석;김홍태;박재홍;안기홍;김용석
    • 한국물환경학회지
    • /
    • 제31권3호
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.

카보닐 계열의 배출 특성과 그에 따른 악취 발생 기여도 비교 연구: 반월공단내 주요 산업시설물들을 중심으로 (Emission Characteristics of Carbonyl Compounds from Major Industrial Sectors in the Ban-Wall Industrial Complex, Korea)

  • 홍윤정;전의찬;김기현
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.679-692
    • /
    • 2006
  • The carbonyl compounds in the atmosphere belong to one of the regulatory pollutants for the malodor control designated by the Korean Ministry of Environment(KMOE). In the present study, the emission concentration levels of carbonyl compounds were measured along with a number of criteria odor pollutants from a total of 47 individual companies(June 2004 to January 2005). The results of our study showed that a number of carbonyl compounds(such as formaldehyde, acetaldehyde, acetone, and butyraldehyde) maintained significantly high mean concentrations of 298 to 372 ppb. In contrast, other carbonyl compounds were low enough with the mean valves of 0.54 to 19.1 ppb. It was found that except for such industries as metal production or leather processing, their emissions were generally quite significant. If the measured values were evaluated in terms of malodor intensity, butyraldehyde appeared to be the most significant contributor to the malodor release. According to the measurements made in strong source areas, it can be concluded that several carbonyl compounds(acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) are useful enough to diagnose malodor release from those source areas. It should also be addressed that a number of carbonyl compounds added newly as the result of malodor control legislation were not sensitive enough to diagnose malodor release from such sources.

통합 환경 관리를 위한 수질 환경의 질 목표 수준 설정 방법에 관한 연구 (A study on the method of setting the water quality target level for integrated environmental management)

  • 황현정;간종범;서지혜;이선경;김영란
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.187-196
    • /
    • 2021
  • When evaluating the extent of the impact of water pollutants on the surrounding area, we would like to present the target level (proposal) of the quality of the environment, which is the standard for evaluation. We propose the environmental quality target level for substances that need to be applied domestically by investigating overseas cases operating the integrated environmental management system and the implications of domestic environmental pollutant management. The appropriateness of the environmental quality target level reviewed in this study was determined using data from the water quality measuring network, and future improvement measures were proposed. We review the available methodologies for setting quality objectives for the environment. It proposed the environmental quality target level for 21 substances that have domestic water pollutant emission standards and do not have environmental standards, and proposed future improvement measures. If it is necessary to add quality target-level items of the environment in the future, it is believed that expansion will be possible based on the methodology presented in this study.

Risk Assessment of Volatile Organic Compounds (VOCs) and Formaldehyde in Korean Public Facilities: Derivation of Health Protection Criteria Levels

  • Kim, Ho-Hyun;Lim, Young-Wook;Shin, Dong-Chun;Sohn, Jong-Ryeul;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권2호
    • /
    • pp.121-133
    • /
    • 2011
  • This study suggests criteria to conduct a risk assessment of VOCs and formaldehyde in uncontrolled public facilities. Pollutants and facilities were selected based on two years of monitoring data and exposure scenarios in 573 uncontrolled public facilities, composed of 10 types of public institutions. With the exception of social welfare facilities, lifetime ECRs of formaldehyde and benzene in each facility were higher in employees than in users, except in social welfare facilities. In social welfare facilities, the risk of benzene for users ($1{\times}10^{-5}$) was higher than that of workers ($1{\times}10^{-6}$) because facility users live in the facility 24 hours per day, compared to workers who spend an average of 8 hours per day in the facility. The risk of benzene to workers in restaurants, academies, performance halls, internet cafe and pubs were estimated as high as $1{\times}10^{-4}$ and the risk to workers in the theaters and karaoke bars were recorded as $1{\times}10^{-5}$. Because lifetime ECRs of carcinogens exceeded $1{\times}10^{-4}$ for workers and users in most facilities, risk management of formaldehyde and benzene in these facilities is necessary. Although HQs of toluene and xylenes did not exceed 1.0, their HQs did exceed 0.1 in some facilities, so they were evaluated as potentially harmful materials. Additionally, criteria for health protection in IAQ by facility are suggested at $60-100\;{\mu}g/m^3$ for formaldehyde, $400-500\;{\mu}g/m^3$ for TVOCs, $10-20\;{\mu}g/m^3$ for benzene, $150-170\;{\mu}g/m^3$ for toluene and $100\;{\mu}g/m^3$ for xylenes, based on the survey on IAQ and HRA methodology. The excess rates of IAQ to health protection criteria in all facilities were 16% for formaldehyde, 8% for TVOCs and benzene, 9% for toulene, and 5% for xylenes.