• 제목/요약/키워드: Creep Displacement

검색결과 88건 처리시간 0.022초

마이크로 압입 크리프 시험기 개발 및 성능평가 (Development and its Performance Evaluation of a Micro-Impression Creep Machine)

  • 양경탁;김현준;김호경
    • Tribology and Lubricants
    • /
    • 제24권1호
    • /
    • pp.27-33
    • /
    • 2008
  • A micro-impression creep machine was designed and developed, adopting a small punch in diameter of 150 um, displacement gage with an accuracy of sub-${\mu}m$ scale, and load-cell with an accuracy of mN scale in order to investigate creep behavior of small solder ball in diameter of less than 1 mm. Creep behavior of lead-free solder ball(Sn-3.0Ag-0.5Cu) in diameter of $760\;{\mu}m$ was investigated in the stress range of $8{\sim}60\;MPa$ and at $303\;K{\sim}393\;K$. The applied load became decreased slightly and continuously in the creep rate of $10^{-4}/s$ range during the current experiments. Also, the machine frame was so sensitive to the environmental temperature that nm scaled displacement recording was unstable according to the change in environmental temperature.

Creep Crack Growth Properties of Low Pressure Turbine Rotor Steel under Constant Load and Ct

  • Jeong, Soon-Uk
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권2호
    • /
    • pp.95-101
    • /
    • 2002
  • The propagation rate(da/dt) prediction parameter and the microstructure properties of creep crack in domestic 3.3NiCrMov steel were investigated at 550$\^{C}$ by using 0.5" CT specimen under constant load(4090N) and constant Ct(300∼4000N/mhr) condition that was maintained during crack growth of 1mm distance. C* usually increased with crack length though load was reduced in order to maintain constant Ct value as crack growth and considerably showed the scatter band, but Ct depended on load line displacement rate and represented a good relation with da/dt. At constant toad and Ct region, crack growth slope was 0.900 and 0.844 each, in the other hand C* slope was 0.480. Fully coalesced area(FCA) ahead of crack tip was increased as Ct value increase to the critical value, and after that value FCA decreased. The average diameter ditribution of cavity in FCA showed the greatest value about 1.5 ㎛ when Ct=2000N/mhr. The increasing of Ct in FCA view point enlarged the size of damage area and the size reached to maximum 800 ㎛ when Ct=2000N/mhr.

Influence of creep on dynamic behavior of concrete filled steel tube arch bridges

  • Ma, Yishuo;Wang, Yuanfeng;Su, Li;Mei, Shengqi
    • Steel and Composite Structures
    • /
    • 제21권1호
    • /
    • pp.109-122
    • /
    • 2016
  • Concrete creep, while significantly changing the static behaviors of concrete filled steel tube (CFST) structures, do alter the structures' dynamic behaviors as well, which is studied quite limitedly. The attempt to investigate the influence of concrete creep on the dynamic property and response of CFST arch bridges was made in this paper. The mechanism through which creep exerts its influence was analyzed first; then a predicative formula was proposed for the concrete elastic modulus after creep based on available test data; finally a numerical analysis for the effect of creep on the dynamic behaviors of a long-span half-through CFST arch bridge was conducted. It is demonstrated that the presence of concrete creep increases the elastic modulus of concrete, and further magnifies the seismic responses of the displacement and internal force in some sections of the bridge. This influence is related closely to the excitation and the structure, and should be analyzed case-by-case.

변형률 적합성을 고려한 토목섬유 보강재의 장기허용강도 결정 모델 (Model to Determine Long-term Allowable Strength of Geosynthetics Reinforcements Considering Strain Compatibility)

  • 전한용;유증조;목문성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1580-1587
    • /
    • 2005
  • To calculate the long-term allowable strength of geosynthetic reinforcement, replacement method was recommended. The isochronous creep curve by S. Turner was used to define the relation between creep strain and allowable strength. In isochronous curve at given time, one can read the allowable strength at allowable creep strain. The allowable strain gets from specification by directors or manufacturers according to the allowable displacement of reinforced structures. The allowable strength can be determined in relation to the allowable horizontal displacement each structures case by case. The effect of install damage on isochronous behaviors of geosynthetic reinforcement was little. In previous study, install damage increase the creep strain slightly. And the degradation was not identified. But it is supposed that degradation increase the creep strain. In conclusion, The recommended model to determine long-term allowable strength of geosynthetic reinforcements considering tensile deformation of reinforcement and soil is fit for proper, correct and economic design for reinforced earth walls.

  • PDF

열 생성 알루미나 박막의 크리프 및 인장 특성 (Creep & Tensile Properties of Thermally Grown Alumina Films)

  • 고경득;선신규;강기주
    • 대한기계학회논문집A
    • /
    • 제31권6호
    • /
    • pp.665-670
    • /
    • 2007
  • Alpha-phase alumina TGO(Thermally Grown Oxide) forms on the interface between zirconia top coat and bond coat of thermal barrier coating system for superalloys during exposure to high temperature over $1000^{\circ}C$. It is known to provide a good protection against hot corrosion and to cause surface failure such as rumpling and cracking due to difference in thermal expansion coefficient from the substrate metal and the lateral growth. Consequently, mechanical properties of the alumina TGO at the high temperature are the key parameters determining the integrity of TBC system. In this work, by using Fecralloy foils as the alumina forming substrate, creep tests and tensile tests have been performed with various TGO thicknesses$(h=0{\sim}4{\mu}m)$ and yttrium contents(0, 200ppm) at $1200^{\circ}C$. Displacement-time curves and load-displacement curves for each TGO thickness(h=1,2,..) were measured from the creep and tensile tests, respectively, and compared with the curves without TGO thickness(h=0). As the result, the intrinsic tensile and creep properties of TGO itself were determined.

몽크만·그랜트관계에 기초한 소형펀치 크리프시험 데이터와 일축 크리프시험 데이터의 관계 (Relationship Between Small-punch Creep Test Data and Uniaxial Creep Test Data based on the Monkman-Grant Relation)

  • 김범준;손일선;임병수
    • 한국정밀공학회지
    • /
    • 제30권8호
    • /
    • pp.809-814
    • /
    • 2013
  • The relationship between the small-punch creep test and the conventional creep test was investigated experimentally using a method similar to that of the Monkman-Grant relationship. Uniaxial and small-punch creep rupture tests were carried out on 9Cr-2W ferritic steel (Commercial Grade 92 steel: X10CrWMoVNb 9-2) at elevated temperatures. From the relation derived in the same manner as the Monkman-Grant relation, a correlation between the displacement rate in response to the small-punch creep test and the strain rate in the uniaxial creep test was found, and the creep life was calculated using this relation. Furthermore, the failure modes of the small punch creep test specimens were investigated to show that the fracture was caused by creep.

Zr-2.5Nb 압력관의 수소화물에 의한 고온 크리프의 열화거동 (Degradation of Thermal Creep by Hydrides of Zr-2/5Nb Pressure Tube)

  • 오동준;마영화;윤기봉;김영석
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1526-1533
    • /
    • 2006
  • The aim of this research was to confirm the existence of the thermal creep degradation by hydrides of Zr-2.5Nb pressure tube materials. Small punch creep tests were performed to obtain the relationship between a creep displacement and a loading period at $300^{\circ}C$. A creep stress and a creep strain rate were also converted from the previous results. The creep material constants and the creep stress exponents at the different hydride contents were compared. Finally the hydrides of the axial and circumferential section were observed using OM, SEM and TEM. The following conclusions were made: 1) The degradation of the thermal creep by hydrides was existed and it strongly depended on the hydride contents. 2) As the hydride contents were increased, the creep stress exponents (m) were also increased. 3) Even though the hydride was not precipitated in 50 ppm materials at $300^{\circ}C$, the degradation of thermal creep was found. Therefore, it was believed that this phenomenon strongly related to the hydride precipitation at room temperature.

소형펀치-크리프 시험에 의한 9Cr1MoVNb강의 고온 크리프 특성 평가 연구 (A Study on Evaluation of High Temperature Creep Properties of 9Cr1MoVNb Steel by Small Punch-Creep test)

  • 유효선;나성훈;백승세;권일현;안병국;나의균
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.99-104
    • /
    • 2000
  • This paper describes the high temperature creep characteristics for virgin material of 9Cr1MoVNb steel using small punch creep(SP-Creep) test technique which is developing recently. In addition, the several results of SP-Creep test are compared with that of 2.25Cr- 1Mo steel which is widely used as boiler materials and that of conventional uniaxial creep test. The obtained SP-Creep curves show the creep behaviors of three regimes like that obtained from conventional uniaxial creep test, and SP-Creep properties are definitely depended on applied load and test temperature. The correlation of SP-Creep rate and creep rupture life with applied load has been determined like the correlation between creep rate/rupture life and stress in uniaxial creep test, and also is satisfied with Power law. The creep rupture times of newly 9Cr1MoVNb steel are higher than those of 2.25Cr1Mo steel at the same creep temperature and applied loading condition, and the decrease extent of creep rupture life with loads is very lower compared with 2.25Cr1Mo steel.

  • PDF

광범위 크리프 조건에 대한 관통균열 배관의 크리프 파괴역학 해석 (Creep Fracture Mechanics Analysis for Through-Wall Cracked Pipes under Widespread Creep Condition)

  • 허남수;김윤재;김영진
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.890-897
    • /
    • 2003
  • This paper compares engineering estimation schemes of C* and creep COD for circumferential and axial through-wall cracked pipes at elevated temperatures with detailed 3-D elastic-creep finite element results. Engineering estimation schemes included the GE/EPRI method, the reference stress method where reference stress is defined based on the plastic limit load and the enhanced reference stress method where the reference stress is defined based on the optimized reference load. Systematic investigations are made not only on the effect of creep-deformation behaviour on C* and creep COD, but also on effects of the crack location, the pipe geometry, the crack length and the loading mode. Comparison of the FE results with engineering estimations provides that for idealized power law creep, estimated C* and COD rate results from the GE/EPRI method agree best with FE results. For general creep-deformation laws where either primary or tertiary creep is important and thus the GE/EPRI method is hard to apply, on the other hand, the enhanced reference stress method provides more accurate and robust estimations for C* and COD rate than the reference stress method.

소형펀치 크리프 시험중 측정하는 변수에 대한 연구 (A Study on Parameters Measured during Small Punch Creep Testing)

  • 박태규;심상훈;윤기봉;장창희
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.171-178
    • /
    • 2002
  • An effect is made in this study to deepen understanding of small punch(SP) creep testing which has been a round for about 10 years as a substitute for the conventional uniaxial creep testing. Even though considerable numbers of SP creep test program have been performed, most of the tests were aimed at measuring creep rupture lives only. Very flew studies showed interest on the meaning of what we were really measuring during the SP creep tests. In this paper meanings of the parameters measured during the SP creep testing, such as punch load and punch displacement rate are investigated using finite element analysis. It was shown that the measured parameters must represent the stress and strain rates of the material at the annular region located at about 0.65 mm from the center of the SP specimen. The material in this location would go through constant maximum stress and strain rate during the testing. Experimental verification is also discussed.