• 제목/요약/키워드: Craniofacial reconstruction

검색결과 228건 처리시간 0.027초

유년기 안구적출술 및 방사선치료로 인하여 발생된 안와 열성장에 대한 재건 치험례 (PRELIMINARY CASE REPORTS OF RECONSTRUCTION FOR ORBITAL HYPOPLASIA AFTER EYEBALL ENUCLEATION AND IRRADIATION DURING CHILDHOOD)

  • 김훈;최미숙;최성원;홍관석;김성문;임재석;권종진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권1호
    • /
    • pp.17-25
    • /
    • 1996
  • There are many reports of the surgical management for the craniofacial abnormalities arising from the irradiation of the head and face for treatment of childhood cancers. Since the mordern combined-modality theraphy for childhood cancers began in the late 1960s and the early 1970s, recent reports have described the occular, dental and maxillo-facial abnormalities after irradiation in long-term survivors of cancers of the head and face. The resultant deformities may be known to be difficult to reconstruct with surgical techniques. This paper describes the late reconstructive surgery for the unilateral orbital and malar hypoplasia after eyeball enucleation and irradiation during childhood to correct the facial asymmetry and expand the contracted orbital socket into the functional dimension for the retaining eyeball prosthesis with spherical implant. We reports the satisfactory preliminary results from the midfacial osteotomy through the supero-lateral orbital rim and malar bone and the antero-lateral repositioning with the autogenous bone grafting in 26 year-old female patient who will be planned to make the new eyeball prosthesis by the department of ophthalmology.

  • PDF

정중 상구순열의 수술적 교정 치험례 (Surgical Correction of a Median Cleft of the Upper Lip Associated with Enlarged Frenulum and Palatal Masses)

  • 한형민;김지예;민희준;김석원
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.485-489
    • /
    • 2011
  • Purpose: Median cleft of upper lip is defined as any congenital vertical cleft through the midline of the upper lip. It is uncommon, its embryological pathogenesis remains unexplained to date. The authors hereby report a rare case of median cleft of the upper lip associated with enlarged frenulum and palatal mass. This case offers some understanding of the possible embryologic development of this anomaly. Methods: A 10-month-old boy born by normal vaginal delivery at full-term had a notch in the midline of the upper lip with widened philtrum along with enlarged median frenulum, alveolar cleft, and mass of the hard palate. We performed en bloc resection of the enlarged frenulum and palatal mass and cheiloplasty under general anesthesia. Results: Histological examination revealed that the frenulum and palatal mass was consisted of fibrous tissue with normal mucous membrane. The postoperative course was satisfactory. Conclusion: A rare case of median cleft of the upper lip with associated enlarged frenulum and palatal mass was presented with proper surgical management. The surgical technique includes marginal excision of the clefted epithelium and reconstruction of orbicularis oris muscle, in addition to en bloc resection of the palatal mass and frenulotomy.

Evaluation of deep learning and convolutional neural network algorithms for mandibular fracture detection using radiographic images: A systematic review and meta-analysis

  • Mahmood Dashti;Sahar Ghaedsharaf;Shohreh Ghasemi;Niusha Zare;Elena-Florentina Constantin;Amir Fahimipour;Neda Tajbakhsh;Niloofar Ghadimi
    • Imaging Science in Dentistry
    • /
    • 제54권3호
    • /
    • pp.232-239
    • /
    • 2024
  • Purpose: The use of artificial intelligence (AI) and deep learning algorithms in dentistry, especially for processing radiographic images, has markedly increased. However, detailed information remains limited regarding the accuracy of these algorithms in detecting mandibular fractures. Materials and Methods: This meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Specific keywords were generated regarding the accuracy of AI algorithms in detecting mandibular fractures on radiographic images. Then, the PubMed/Medline, Scopus, Embase, and Web of Science databases were searched. The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was employed to evaluate potential bias in the selected studies. A pooled analysis of the relevant parameters was conducted using STATA version 17 (StataCorp, College Station, TX, USA), utilizing the metandi command. Results: Of the 49 studies reviewed, 5 met the inclusion criteria. All of the selected studies utilized convolutional neural network algorithms, albeit with varying backbone structures, and all evaluated panoramic radiography images. The pooled analysis yielded a sensitivity of 0.971 (95% confidence interval [CI]: 0.881-0.949), a specificity of 0.813 (95% CI: 0.797-0.824), and a diagnostic odds ratio of 7.109 (95% CI: 5.27-8.913). Conclusion: This review suggests that deep learning algorithms show potential for detecting mandibular fractures on panoramic radiography images. However, their effectiveness is currently limited by the small size and narrow scope of available datasets. Further research with larger and more diverse datasets is crucial to verify the accuracy of these tools in in practical dental settings.

가토의 하악골에서 골신장기 동안 반복 골신장술이 골형성에 미치는 효과 (THE EFFECT OF OSCILLATING DISTRACTION OSTEOGENESIS ON NEW BONE FORMATION DURING MANDIBULAR DISTRACTION PERIOD IN RABBITS)

  • 권준경;박홍주;유선열
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권3호
    • /
    • pp.241-249
    • /
    • 2006
  • Purpose For the reconstruction of craniofacial deformities, the distraction osteogenesis is an useful method which can make new soft tissues as well as new bone. Although the distraction osteogenesis is an effective procedure in quantitative aspects, the new bone formed by this procedure can be coarse in qualitive aspects sometimes. Materials and methods Twelve rabbits, weighing about 2 kg, were included and the prefabricated distraction device were used. After a latency period of 5 days, in the experimental group (n=6), the mandible was distracted at the rate of 1.0 mm/day for 2 days and then compressed with 1.0 mm for the next 3rd day, therefore distracted totally to a length of 1.0 mm for 3 days. This procedure was repeated 5 times and, as a result, the experimental group was distracted to a length of 5.0 mm for 15 days finally. In the control group (n=6), the mandible was distracted totally to a length of 5.0 mm at the rate of 1 mm/day. At 2 weeks and 8 weeks of consolidation in the control group, 3 rabbits in each group were sacrificed and their biopsy specimens from the distracted mandible were taken. Results All animals showed the mandibular elongation clinically and radiographically. Histologically, many blood vessels, osteoblasts and immature bones formed by osteoid deposition were observed in the experimental group at 2 weeks. At 8 weeks, the bony trabeculae were thicker than the ones in the control group and were composed of lamella bones and woven bones in the experimental group. On histomorphometric analysis, the bone deposition area of the distracted site was broader in the experimental group $(273.8{\pm}115.7\;cm^2)$ than the one in the control group $(199.4{\pm}101.4\;cm^2)$. Futhermore, the modified rate of bone deposition area was higher in the experimental group (48${\pm}$20%) than the one in the control group (35${\pm}$18%). However, these data showed no significant differences statistically. Conclusion These results suggest that the distraction osteogenesis by using an alternating distraction/compression protocols is an effective method for increasing new bone formation in distracted areas.

반안면 왜소증 환자에서의 골신장술: 증례보고 (THE USE OF DISTRACTION OSTEOGENESIS TO TREAT HEMIFACIAL MICROSOMIA: A CASE REPORT)

  • 백성문;김수관;김학균;문성용
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권5호
    • /
    • pp.559-566
    • /
    • 2007
  • Distraction osteogenesis(DO) is a surgical method of bone formation that involves an osteotomy and sequential stretching of the healing callus by gradual movement and subsequent remodeling. DO is used to correct facial asymmetry, such as in patients with hemifacial microsomia, maxillary or mandibular retrusion, cleft lip and palate, alveolar defects, and craniofacial deficiency. It is accomplished with the aid of a distraction device, which is secured with screws placed directly into bone, for a predetermined length of time. Hemifacial microsomia is characterized by unilateral facial hypoplasia, often with unilateral shortening of the mandible and subsequent malocclusion. Patients with hemifacial microsomia and facial asymmetry have a vertically short maxilla, tilted occlusal plane, and short mandible. Early treatment is necessary to avoid subsequent impaired midfacial growth. The standard treatment of these malformations consists of the application of bone grafts, which can lead to unpredictable growth. The new bone-lengthening procedure represents a limited surgical intervention and opens up a new perspective for treatment, especially in younger children with severe deformities. This report describes a case of hemifacial microsomia(Type-II left-sided hemifacial microsomia). The patient, a 10-year-old child, visited our clinic for facial asymmetry correction. He had a hypoplastic mandible, displaced ear lobe, 10 mm canting on the right side, and malocclusion. We planned DO to lengthen the left mandible in conjunction with a Le Fort I osteotomy for decanting and then perform a right intraoral vertical ramus osteotomy(IVRO). Progressive distraction at a rate of 0.5 mm/12 hours was initiated 7 days postoperatively. The duration of DO was 17 days. The consolidation period was 3 months. Satisfactory results were obtained in our case, indicating that DO can be used successfully for functional, aesthetic reconstruction of the mandible. We report a case involving DO in conjunction with orthognathic surgery for correcting mandibular hypoplasia with a review of the literature.

Performance of ChatGPT 3.5 and 4 on U.S. dental examinations: the INBDE, ADAT, and DAT

  • Mahmood Dashti;Shohreh Ghasemi;Niloofar Ghadimi;Delband Hefzi;Azizeh Karimian;Niusha Zare;Amir Fahimipour;Zohaib Khurshid;Maryam Mohammadalizadeh Chafjiri;Sahar Ghaedsharaf
    • Imaging Science in Dentistry
    • /
    • 제54권3호
    • /
    • pp.271-275
    • /
    • 2024
  • Purpose: Recent advancements in artificial intelligence (AI), particularly tools such as ChatGPT developed by OpenAI, a U.S.-based AI research organization, have transformed the healthcare and education sectors. This study investigated the effectiveness of ChatGPT in answering dentistry exam questions, demonstrating its potential to enhance professional practice and patient care. Materials and Methods: This study assessed the performance of ChatGPT 3.5 and 4 on U.S. dental exams - specifically, the Integrated National Board Dental Examination (INBDE), Dental Admission Test (DAT), and Advanced Dental Admission Test (ADAT) - excluding image-based questions. Using customized prompts, ChatGPT's answers were evaluated against official answer sheets. Results: ChatGPT 3.5 and 4 were tested with 253 questions from the INBDE, ADAT, and DAT exams. For the INBDE, both versions achieved 80% accuracy in knowledge-based questions and 66-69% in case history questions. In ADAT, they scored 66-83% in knowledge-based and 76% in case history questions. ChatGPT 4 excelled on the DAT, with 94% accuracy in knowledge-based questions, 57% in mathematical analysis items, and 100% in comprehension questions, surpassing ChatGPT 3.5's rates of 83%, 31%, and 82%, respectively. The difference was significant for knowledge-based questions(P=0.009). Both versions showed similar patterns in incorrect responses. Conclusion: Both ChatGPT 3.5 and 4 effectively handled knowledge-based, case history, and comprehension questions, with ChatGPT 4 being more reliable and surpassing the performance of 3.5. ChatGPT 4's perfect score in comprehension questions underscores its trainability in specific subjects. However, both versions exhibited weaker performance in mathematical analysis, suggesting this as an area for improvement.

구순구개열 환아에서의 치조골이식 (TOOTH MOVEMENTS TO THE SITE OF ALVEOLAR BONE GRAFT)

  • 조해성;박재홍;김광철;최성철;이긍호;최영철
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.140-149
    • /
    • 2007
  • 치조파열 및 구개열과 같은 선천성 기형은 이환된 환자에게 기능적, 심미적으로 많은 문제점을 야기하므로 정상으로 회복시켜 주는 것은 중요한 문제이다. 장기간 방치될 경우 영양장애, 구강위생 불량, 호흡기 감염, 언어 장애, 악안면 변형, 그리고 정신적인 문제 등이 복합적으로 발생할 수 있다. 따라서 구순구개열 환자의 치료는 여러 전문 치료 분야의 복합적 인 접근이 필요하다. 골이식은 구순구개열 환자에 있어 중요한 치과치료 단계이다. 치아의 맹출과 치열의 안정화를 위해 치열궁은 골결손이 없이 완전해져야 한다. 또한 치열궁의 파열이 있는 부위로는 정상적인 교정적 치아이동이 곤란하다. 따라서 구순구개열 환자에 있어 골이식은 광범위하게 적용되고 있는 외과적 술식이다. 치조골을 이식함으로써 치조열은 안정화되고, 견치 또는 절치가 이식부위로 이동할 수 있게 된다. 그리고 골 이식 후, 교정을 통해 치조열 부위의 공간을 폐쇄함으로써 보철치료 없이 치열을 재형성 할 수 있다. 골이식술에는 다양한 이식재료가 사용되었다. 자가골을 이식할 경우 장골이 가장 선호되며, 그밖에 경골, 늑골, 두개골, 하악골을 이용하기도 한다. 그리고 골이식은 골이식 시기에 따라 일차골이식, 조기 이차골이식, 이차골이식, 만기 이차골이식으로 구분할 수 있다. 이차골이식은 혼합치열기 말경에 시행되는 것을 말하며 가장 좋은 것으로 받아들여지고 있다. 영구 견치가 맹출되기 전에 이차골이식을 시행하면 인접치아의 맹출과 보존에 도움이 된다. 본 증례에서는 치조구개파열 환자의 장골에서 골을 채취하여 골 이식을 시행한 후, 골이 채워진 이식 부위에 인접 치아가 성공적으로 이동하거나 치축이 개선되고 교정치료를 통해 치열궁 배열의 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

  • PDF

두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가 (Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.131-140
    • /
    • 2003
  • 3차원 영상의 해부학 구조에 대한 정확한 거리 측정은 중요한 역할을 하고 있으므로, 인체 두개골 팬텀을 사용하여 다검출기 CT에서의 슬라이스 두께별 획득 변수에 따른 3차원 영상의 정량적 특성에 관하여 거리 측정방법에 의한 정확도 평가를 실시하였다. 두개골 팬텀의 외부에 임상적으로 중요한 의미를 갖는 21 개의 위치를 표시하고 각 점간의 거리를 실측하였다. 실측한 데이터는 3차원 재구성 영상의 계측값과 비교평가 하기 위한 기준으로 삼았다. 다검출기 CT를 사용하여 200 mA, 120 kVp의 X-선 튜브 조건과 갠트리 회전 당 스캔(scan) 시간 1초로 단면영상을 획득하였다. 축형 모드와 나선형 모드(pitch 3:1, 6:1)에서 각각 1.25 mm, 2.50 mm, 3.75 mm, 5.00 mm의 슬라이스 두께로 획득하였고, 나선형 모드에서 획득된 단면영상을 다시 1.25 mm로 획득하였다. 영상분석 소프트웨어를 이용하여 3차원 영상 재구성 및 거리측정을 하고 통계분석을 실시하였다. 1.25 mm, 2.50 mm, 3.75 mm, 5.00 mm의 계측값의 정확도는 각각 48%, 33%, 23%, 14%로 나타났으며 1.25 mm로 재구성한 3차원 영상의 정확도는 각각 53%, 41%, 43%, 36%로 나타났다. 그러나, 1.25 mm로 재구성한 3차원영상들 간의 거리측정의 정확도 사이에서 통계적으로 유의할 만한 수준(P-value<0.05)의 차이는 보이지 않았다. 다검출기 CT의 영상획득 변수에 따른 3차원 재구성 영상에서의 각 점간의 거리측정 결과는 피치나 스캔 모드에서 보다 슬라이스 두께와 재구성 슬라이스 두께에 따른 영향이 더욱 크다는 것을 나타내었다.

  • PDF