• Title/Summary/Keyword: Craniofacial cleft

Search Result 845, Processing Time 0.021 seconds

Facial injury burden of personal mobility devices: a single-center retrospective analysis

  • Yoon, Jae Hee;Jeon, Hong Bae;Kang, Dong Hee;Kim, Hyonsurk
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.4
    • /
    • pp.163-170
    • /
    • 2022
  • Background: Personal mobility devices (PMDs) have become an increasingly popular transport modality globally. With increasing social interest in and demand for PMDs, the number of individuals visiting emergency departments with PMD-related injuries has also increased annually. This study aimed to evaluate injury patterns and treatment costs for patients treated in the department of plastic surgery in a trauma center. Methods: In this retrospective study, data concerning patients with PMD-related injuries from January 2017 to December 2021 were reviewed. The data retrieved included age, sex, alcohol consumption, helmet use, the type of impact, onset of injury, place of first visit, type of injury, admission status, operation status, and treatment cost. Multiple linear regression analysis was performed to determine the effects of various factors on cost. Results: Data were collected from 93 patients. Until 2019, the annual number of PMD-related accidents was less than 10; however, this number increased sharply in 2020. The average cost of hospitalization was USD 7,698 whereas the average cost of non-hospitalization was USD 631. Only fractures had a significant association with total cost in linear regression analysis (p< 0.001). Conclusion: The prevalence of PMD use and related injuries requiring plastic surgery during the study period showed significant health and financial costs both to the patients involved and to society. This cost could be reduced through stricter regulations concerning PMD use, advocating the use of protective gear, and promoting greater awareness of safety measures and of the consequences of PMD-related accidents.

Cranioplasty and temporal hollowing correction with a three-dimensional printed bioresorbable mesh and double vertical suture anchor muscle sling: a case report

  • Choi, Jae Hyeok;Roh, Tai Suk;Lee, Won Jai;Baek, Wooyeol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.4
    • /
    • pp.178-182
    • /
    • 2022
  • Postoperative temporal hollowing is a common complication of craniotomy. Damage and repositioning of the temporalis muscle can lead to a depression in the temporal side of the skull with inferior bulging, worsening aesthetic outcomes. We report a case of cranioplasty with three-dimensional (3D) printed mesh involving an additional correction using a temporalis muscle sling to help address this problem. A 3D-printed bioabsorbable mesh was prepared based on preoperative facial computed tomography, and was fixed to the hollowed area for tissue augmentation. The temporalis muscle was elevated and fanned out to its original position, and a sling was attached to a screw that was fixed to the mesh. For reinforcement, an additional sling was attached to another screw fixed to the mesh 2-3 cm vertically above the first screw. Aesthetic results were confirmed immediately after surgery and later during outpatient follow-up. Both depression and lateral bulging were resolved, and there was no delayed drooping of the temporalis muscle on 6-month follow-up. There were no complications, and the patient was satisfied with the appearance. This is a simple yet effective technique with a low risk of complications, and should be considered for postoperative temporal hollowing patients, especially those with severe lateral bulging.

Reduction of comminuted fractures of the anterior wall of the frontal sinus using threaded Kirschner wires and a small eyebrow incision

  • Lee, Da Woon;Kwak, Si Hyun;Choi, Hwan Jun;Kim, Jun Hyuk
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.5
    • /
    • pp.220-227
    • /
    • 2022
  • Background: Frontal sinus fractures are relatively rare. Their surgical management significantly differs depending on whether the posterior wall is invaded and the clinical features vary. A bicoronal incision or endoscopic approach can be used. However, the minimally invasive approach has been attracting attention, leading us to introduce a simple and effective surgical method using multiple-threaded Kirschner wires. Methods: All patients had isolated anterior wall fractures without nasofrontal duct impairment. The depth from the skin to the posterior wall was measured using computed tomography to prevent injury. The edge of the bone segment on the skin was marked, a threaded Kirschner wire was inserted into the center of the bone segment, and multiple Kirschner wires were gently reduced simultaneously. Results: Surgery was performed on 11 patients. Among them, seven patients required additional support for appropriate fracture reduction. Therefore, a periosteal elevator was used as an adjunct through a small sub-brow incision because the reduction was incomplete with the Kirschner wire alone. The reduction results were confirmed using facial bone computed tomography 1 to 3 days postoperatively. The follow-up period was 3 to 12 months. Conclusion: The patients had no complications and were satisfied with the surgical results. Here we demonstrated an easy and successful procedure to reduce a pure anterior wall frontal sinus fracture via non-invasive threaded Kirschner wire reduction.

Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report

  • Shin, Jin Yong;Lee, Nae-Ho;Kim, Min-Seok;Roh, Si-Gyun;Chung, Yoon Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.5
    • /
    • pp.228-231
    • /
    • 2022
  • Fibrin glue is a topical agent widely used for hemostasis, wound healing, and surgical adhesion. Complications of fibrin glue itself are extremely rare because it is absorbed over time, but can occur as a result of inappropriate application. We report a case of a postoperative complication caused by inappropriate application of fibrin glue in blow-out fracture surgery. A 65-year-old male patient presented with periorbital swelling and an open wound on the right infraorbital area. Computed tomography showed a right orbital floor fracture. After reduction of the herniated tissue into the orbit, an implant was inserted and fibrin glue was applied to stabilize the implant. This procedure was performed without difficulty, but the patient complained of persistent diplopia and limited eyeball movement after surgery. An imaging study showed a mass-like lesion, which was not a hematoma, in the orbital cavity. In a second operation, the mass was identified as clotted fibrin glue that had not been applied properly. After removal, the patient's symptoms were relieved without further complications. Appropriate and careful application of fibrin glue is necessary to avoid unnecessary complications.

Surgical refinement of the purse-string suture for skin and soft tissue defects of the head and neck

  • Park, Hyochun;Lee, Yunjae;Yeo, Hyeonjung;Park, Hannara
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.4
    • /
    • pp.183-192
    • /
    • 2021
  • Background: The purse-string suture (PSS) is a simple and rapid wound closure method that results in minimal scarring. It has been used to treat circular or oval skin defects caused by tumor excision or trauma. However, due to obscurity, it is not widely used, especially for the head and neck. This study aimed to modify the PSS to obtain predictable and acceptable results. Methods: A total of 45 sites in 39 patients with various types of skin and soft tissue defects in the head and neck were treated with PSS. We used PDS II (2-0 to 5-0), which is an absorbable suture. Minimal dissection of the subcutaneous layer was performed. The suture knot was hidden by placing it in the dissection layer. Depending on the characteristics of the skin and soft tissue defects, additional surgical interventions such as side-to-side advancement sutures, double PSS, or split-thickness skin graft were applied. Results: All wounds healed completely without any serious complications. Large defects up to 45 mm in diameter were successfully reconstructed using only PSS. Postoperative radiating folds were almost flattened after approximately 1-2 months. Conclusion: PSS is simple, rapid, and relatively free from surgical design. Owing to the circumferential advancement of the surrounding tissue, PSS always results in a smaller scar than the initial lesion and less distortion of the body structures around the wound in the completely healed defect. If the operator can predict the process of healing and immediate radiating folds, PSS could be a favorable option for round skin defects in the head and neck.

Clinical association between serum cholesterol level and the size of xanthelasma palpebrarum

  • Kim, Young Geun;Oh, Jae Wook;Lee, Keun Cheol;Yoon, Sung Ho
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.71-76
    • /
    • 2022
  • Background: Xanthelasma palpebrarum (XP) is a benign periorbital lesion. The relationship between xanthelasma lesion size and serum cholesterol levels has been poorly studied. In this study, we investigated this relationship in the context of the clinical etiology of XP. Methods: We retrospectively reviewed medical records and pathology reports of all patients treated for XP at our hospital between June 2014 and June 2021; the data were used to analyze lesion size, underlying disease, serum cholesterol, and disease recurrence. Results: The mean values for patient age, serum cholesterol, and lesion size were 53.0 years, 235.0 mg/dL, and 69.2 mm2, respectively. XP mainly occurred in women (64.7%); furthermore, the incidence of XP and lesion size was greatest among patients in their 5th decade of life (41.2%). There was no statistically significant relationship between xanthelasma lesion size and serum cholesterol level. Conclusion: This study compared lesion size with various clinical features in XP patients. In patients who underwent surgery for XP, serum cholesterol levels tended to be higher than those in the general population. However, the trend between the size of XP and serum cholesterol level was unclear. Therefore, if a patient with XP visits the hospital for surgery, it is recommended to check the lipid profile to confirm underlying dyslipidemia regardless of the size.

Perforating patterns of cutaneous perforator vessels in anterolateral thigh flaps for head and neck reconstruction and clinical outcomes

  • Lee, Sang Soo;Hong, Jong Won;Lee, Won Jae;Yun, In-Sik
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.64-70
    • /
    • 2022
  • Background: Anterolateral thigh (ALT) flaps are versatile soft tissue flaps that have become the standard soft-tissue flaps used for head and neck reconstruction. They provide a long vascular pedicle, constant vessel diameter, abundant soft tissue coverage, and minimal donor site morbidity. The ALT flap was initially designed on the basis of a septocutaneous (SC) perforator. However, more recent research has shown that a substantial number of ALT flaps are now based on musculocutaneous (MC) perforators, and the ratio between MC and SC perforators varies among studies. In this study, we analyzed the perforating pattern of ALT flaps along with their clinical outcomes during head and neck reconstruction in the Korean population. Methods: From October 2016 to July 2020, 68 patients who had undergone an ALT flap procedure for head and neck reconstruction were enrolled retrospectively. The perforating pattern of the cutaneous perforator vessel (MC perforator/SC perforator/oblique branch), pedicle length, and flap size were analyzed intraoperatively. Patient demographics and flap necrosis rates were also calculated. Results: The highest number of cutaneous perforator vessels supplying the ALT flap were the MC perforators (87%). The proportion of MC perforators was significantly higher than that of the SC perforators and oblique branches. Flap necrosis occurred in seven cases (11.86%); sex, hypertension, diabetes mellitus, coronary artery disease, perforator course, and history of radiotherapy did not significantly affect flap necrosis. Conclusion: The ALT free flap procedure remains popular for reconstruction of the head and neck. In this study, we observed that the majority of cutaneous vessels supplying the flaps were MC perforators (87%). When using the MC perforator during flap elevation, careful dissection of the perforator is required to achieve successful ALT flaps because intramuscular dissection is difficult. Perforator pattern and history of radiotherapy did not affect flap necrosis.

Ruptured pseudoaneurysm of the internal maxillary artery in zygomaticomaxillary fracture: a case report

  • Lim, Soo Yeon;Lee, Hyun Gun;Kim, Kyu Nam;Kim, Hoon;Oh, Dong Hyun;Koh, In Chang
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.89-92
    • /
    • 2022
  • Post-traumatic pseudoaneurysms of internal maxillary artery are rare, but may be life-threatening. When arterial damage leads to pseudoaneurysm formation, delayed intractable epistaxis can occur. We report our experience with the diagnosis and management of a ruptured internal maxillary arterial pseudoaneurysm that was discovered preoperatively in a patient with a zygomaticomaxillary complex (ZMC) fracture. He presented to the emergency room with epistaxis, which ceased shortly, and sinus hemorrhage was observed with a fracture of the posterior maxillary wall. The patient was scheduled for open reduction and internal fixation (ORIF) of the ZMC fracture. However, immediately before surgery, uncontrolled epistaxis of unknown origin was observed. Angiography indicated a pseudoaneurysm of the posterior superior alveolar artery. Selective endovascular embolization was performed, and hemostasis was achieved. After radiologic intervention, ORIF was successfully implemented without complications. Our case shows that in patients with a posterior maxillary wall fracture, there is a risk of uncontrolled bleeding in the perioperative period that could be caused by pseudoaneurysms, which should be considered even in the absence of typical symptoms.

Sequencing of panfacial fracture surgery: a literature review and personal preference

  • Jae Hee, Yoon;Dong Hee, Kang;Hyonsurk, Kim
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.6
    • /
    • pp.256-261
    • /
    • 2022
  • Background: Treating panfacial fractures (PFFs) can be extremely difficult even for experienced surgeons. Although several authors have attempted to systemize the surgical approach, performing surgery by applying a unidirectional sequence is much more difficult in practice. The purpose of this study was to review the literature on PFF surgery sequence and to understand how different surgical specialists-plastic reconstructive surgery (PRS) and oral maxillofacial surgery (OMS)-chose sequence and review PFFs fixation sequence in clinical cases. Methods: The PubMed and Google Scholar databases were scoured for publications published up until May 2020. Data extracted from the studies using standard templates included fracture part, fixation sequence, originating specialist, and the countries. Bibliographic details like author and year of publication were also extracted. Also, we reviewed the data for PFFs patients in the Trauma Registry System of Dankook University Hospital from 2011 to 2021. Results: In total, 240 articles were identified. This study comprised 22 studies after screening and full-text analysis. Sixteen studies (12 OMS specialists and 4 PRS specialists) used a "bottom-top" approach, whereas three studies (1 OMS specialist and 2 PRS specialists) used a "top-bottom" method. However, three studies (only OMS specialists) reported on both sequences. In our hospital, there were a total of 124 patients with PFF who were treated during 2011 to 2021; 64 (51.6%) were in upper-middle parts, 52 (41.9%) were in mid-lower parts, and eight (6.5%) were in three parts. Conclusion: Bottom-top sequencing was mainly used in OMS specialists, and top-bottom sequencing was used at a similar rate by two specialists in literature review. In our experience, however, it was hard to consistently implement unidirectional sequence suggested by a literature review. We realigned the reliable and stable buttresses first with tailoring individually for each patient, rather than proceeding in the unidirectional sequence like bottom-top or top-bottom.

Sensory change and recovery of infraorbital area after zygomaticomaxillary and orbital floor fractures

  • Sang Woo, Han;Jeong Ho, Kim;Sug Won, Kim;Sung Hwa, Kim;Dae Ryong, Kang;Jiye, Kim
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.6
    • /
    • pp.262-268
    • /
    • 2022
  • Background: To compare the sensory change and recovery of infraorbital area associated with zygomaticomaxillary and orbital floor fractures and their recoveries and investigate the factors that affect them. Methods: We retrospectively reviewed 652 patients diagnosed with zygomaticomaxillary (n= 430) or orbital floor (n= 222) fractures in a single center between January 2016 and January 2021. Patient data, including age, sex, medical history, injury mechanism, Knight and North classification (in zygomaticomaxillary fracture cases), injury indication for surgery (in orbital floor cases), combined injury, sensory change, and recovery period, were reviewed. The chi-square test was used for statistical analysis. Results: Orbital floor fractures occurred more frequently in younger patients than zygomaticomaxillary fractures (p< 0.001). High-energy injuries were more likely to be associated with zygomaticomaxillary fractures (p< 0.001), whereas low-energy injuries were more likely to be associated with orbital floor fractures (p< 0.001). The sensory changes associated with orbital floor and zygomaticomaxillary fractures were not significantly different (p= 0.773). Sensory recovery was more rapid and better after orbital floor than after zygomaticomaxillary fractures; however, the difference was not significantly different. Additionally, the low-energy group showed a higher incidence of sensory changes than the high-energy group, but the difference was not statistically significant (p= 0.512). Permanent sensory changes were more frequent in the high-energy group, the difference was statistically significant (p= 0.043). Conclusion: The study found no significant difference in the incidence of sensory changes associated with orbital floor and zygomaticomaxillary fractures. In case of orbital floor fractures and high-energy injuries, the risk of permanent sensory impairment should be considered.