• Title/Summary/Keyword: Cracking potential

Search Result 134, Processing Time 0.018 seconds

Mechanical Modeling of Pen Drop Test for Protection of Ultra-Thin Glass Layer (초박형 유리층 보호를 위한 펜 낙하 시험의 기계적 모델링)

  • Oh, Eun Sung;Oh, Seung Jin;Lee, Sun-Woo;Jeon, Seung-Min;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.3
    • /
    • pp.49-53
    • /
    • 2022
  • Ultra-thin glass (UTG) has been widely used in foldable display as a cover window for the protection of display and has a great potential for rollable display and various flexible electronics. The foldable display is under impact loading by bending and touch pen and exposed to other external impact loads such as drop while people are using it. These external impact loads can cause cracks or fracture to UTG because it is very thin under 100 ㎛ as well as brittle. Cracking and fracture lead to severe reliability problems for foldable smartphone. Thus, this study constructs finite element analysis (FEA) model for the pen drop test which can measure the impact resistance of UTG and conducts mechanical modeling to improve the reliability of UTG under impact loading. When a protective layer is placed to an upper layer or lower layer of UTG layer, stress mechanism which is applied to the UTG layer by pen drop is analyzed and an optimized structure is suggested for reliability improvement of UTG layer. Furthermore, maximum principal stress values applied at the UTG layer are analyzed according to pen drop height to obtain maximum pen drop height based on the strength of UTG.

Evaluation of Freeze-Thaw Damage on Concrete Using Nonlinear Ultrasound (초음파의 비선형 특성을 이용한 콘크리트 동결융해 손상 평가)

  • Choi, Ha-Jin;Kim, Ryul-Ri;Lee, Jong-Suk;Min, Ji-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.56-64
    • /
    • 2021
  • Leakage due to deterioration and damage is one of the major causes of volume change by freezing and thawing, and it leads micro-cracking and surface scaling in concrete structures. The deterioration of damaged concrete accelerates with the chloride attack. Thus, in the detailed guidelines for facility performance evaluation (2020), the quality of cover concrete and the freeze-thaw (FT) repetition cycle were newly suggested for concrete durability assessment. The quality of cover concrete should be evaluated by the rebound hammer test and the FT repetition cycle should be also considered in the deterioration environmental assessment. This study suggested the application of fast dynamic based nonlinear ultrasound method to monitor initial micro-scale damage under freezing and thawing environment. Concrete specimens were fabricated with different water-cement ratios (40%, 60%) and air contents (1.5% and 3.0%). The compressive strength, rebound number, relative dynamic modulus, and nonlinear ultrasound were measured with different FT cycles. The scanning electron microscopy was also performed to investigate the micro-scale FT damage. As a result, both the rebound number and the relative dynamic modulus had difficulty to detect early damage but the proposed method showed a potential to detect initial micro-scale damage and predict the FT resistance performance of concrete.

Influence of Curing Conditions on Volumetric Changes in Concrete (양생 조건이 콘크리트의 체적 변화에 미치는 영향)

  • Lee, Kwang-Myong;SunWoo, Joo-Yeun;Lee, Hoi-Keun;Khayat, Kamal H.
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.331-338
    • /
    • 2006
  • This paper presents the experimental results on volumetric changes in ordinary portland cement concrete made with various water-to-cement ratios(W/C's) ranging from 0.32 to 0.50 and cured in low different conditions. Curing regimes employed in this work were designed to exhibit autogenous and drying shrinkage as well as swelling of concrete. The concrete avoided any moist evaporation(Regime f showed only autogenous shrinkage and the lower the W/C, the feater the autogenous shrinkage. The concrete exposed to air drying conditions at $20{\pm}1^{\circ}C$ and $60{\pm}3%$ RH after 6-day water curing at $20{\pm}1^{\circ}C$(Regime II) swelled and then started to shrink. The maximum swelling value of concrete developed in water curing was between 15 and $40{\pm}10^{-6}$, and the greatest total shrinkage(autogenous+drying shrinkage) was obtained for the mixture made with W/C of 0.32. The concrete let to air drying conditions(Regime III) showed greater total shrinkage compared to the concrete cured in Regime II. The concrete exposed to air drying condition after 6-day sealed curing(Regime IV) exhibited slightly smaller total shrinkage than that of the concrete cured in Regime III. Net drying shrinkage that can be derived from the results of Regime I, III, and IV increased as the W/C increased despite of similar total shrinkage. This result indicated that drying shrinkage governs total shrinkage of high-W/C concretes. In other words, a portion of autogenous shrinkage in total shrinkage increased in low-W/C concretes. Therefore, it should be controlled in terms of cracking potential. Finally, total shrinkage of high-strength and high-performance concrete made with low W/C can be effectively reduced by appropriate early moisture curing.

Evaluation of Agronomic Characteristics, Nutritional Contents, and Insect Response of the Transgenic Potato Resistant to Glufosinate Ammonium (제초제 저항성 형질전환 감자의 농업적 특성, 영양 성분 및 해충 반응성 평가)

  • Ahn, Soon-Young;Cho, Kwang-Soo;Seo, Hyeo-Won;Yi, Jeong-Yoon;Bae, Shin-Cheol;Cho, Ji-Hong;Park, Young-Eun;Kim, Ju-Il;Kim, Hyun-Jun;Cho, Hyun-Mook
    • Horticultural Science & Technology
    • /
    • v.29 no.3
    • /
    • pp.247-254
    • /
    • 2011
  • The agronomic characteristics, nutritional contents, and insect response of the potato clones transformed with a glufosinate ammonium resistance gene were evaluated. Among the 4 transgenic potato clones, the Bar 3 clone was selected as a promising one for commercialization. The Bar 3 clone showed similar tuber yield capacity but higher herbicide resistance as compared with the non-transgenic potato cv. Dejima. The herbicide resistance of the Bar 3 clone was more than 5 times higher when tested with the herbicide concentration recommended by the producer. The major agronomic characteristics of the Bar 3 clone were not different from those of the non-transgenic Dejima. The annual variation in yields and agronomic characteristics showed similar tendency for 2 years from the third to fourth generation after transformation. The tubers of the Bar 3 clone also showed low occurrence in common scab and physiological disorders such as cracking and secondary growth. But the reasons for such results are yet to be studied. Also, it was considered that the Bar 3 clone have a potential of reducing not only common scab occurrence but also soil erosion during potato cultivation in field. The nutritional contents (mineral compound, vitamin C and amino acid) and response to Spodoptera exigua of the transgenic potato clones were not significantly different.