• Title/Summary/Keyword: Crack start test

Search Result 14, Processing Time 0.021 seconds

Hot Cracking Behavior in Inconel 690 Overlay Welds on Mn-Ni-Cr-Mo Steel for Pressure Vessels (Mn-Ni-Cr-Mo강에 대한 Inconel 690 오버레이 용접부에서의 고온균열의 발생거동)

  • 양병일;김정태;신용범;안용식;박화순
    • Journal of Welding and Joining
    • /
    • v.20 no.2
    • /
    • pp.82-89
    • /
    • 2002
  • In order to clarify hot cracking phenomena occurred in Inconel 690 welds and it's prevention, in this study, the cracking behavior and the influence of welding variables on cracking in Inconel 690 overlay welds on Mn-Ni-Cr-Mo steel(SA 508 cl.3) for pressure vessel were investigated by using mock-up test. The main results are as follows: The cracks in Inconel 690 overlay welds were mainly generated near the start and the end part of welding beads adjacent to STS 309L welded outside of Inconel 690 welds. Most of the cracks showed typical solidification crack, and also it was assumed that there was possibility of liquation cracking in HAZ. The existence of Nb constituents or concentration of Nb was recognized on the fracture facets of the solidification cracks in the welds by SMAW. Therefore Nb was considered to be the main factor of the solidification cracking. As the weld heat input was more increased and the weld bead length was longer, the extent of cracking was more increased. Moreover the extent of cracking was considerably decreased by changing of welding sequence to the start and the end part of welds. Hot cracking in welds by GTAW was considerably decreased as compared with that of SMAW. And cracks were well generated in the Inconel 690 overlay welds adjacent to 575 309L welds. This means that the hot cracking susceptibility of Inconel 690 welds was largely varied by chemical components and/or compositions of filter metals, base metals and neighboring welds.

A Study on Determination of $J_{IC}$ by Time-Frequency Analysis Method (시간-주파수 해석법에 의한 $J_{IC}$결정에 관한 연구)

  • Nam, Gi-U;An, Seok-Hwan;Kim, Bong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.5
    • /
    • pp.765-771
    • /
    • 2001
  • Elastic-plastic fracture toughness JIC can be used a s an effective design criterion in elastic-plastic fracture mechanics. Among the JIC test methods approved by ASTM, unloading compliance method was used in this study. In order to examine the relationship between fracture behavior of JIC test and AE signals, the post processing of AE signals has been carried out by Short Time Fourier Transform(STFT), one of the time-frequency analysis methods. The objective of this study is to evaluate the application of characterization of AE signals for unloading compliance method of JIC test. As a result of time-frequency analysis, we could extract the AE from the raw signal and analyze the frequencies in AE signal at the same time. AE signal generated by elastic-plastic fracture of material has some different aspects at elastic and plastic ranges, or the first portion of crack growth by fracture. First of all, increased energy recorded and detected by using AE count method increase rapidly from the start of ductile fracture. The variation of main frequency range with time-frequency analysis method could be confirmed. We could know fracture behavior of interior material by examination AE characteristics generated in real-time when elastic-plastic fracture occurred in material under loading.

Conservation and Pedestal Stability Estimation of the Bukji-ri Stone Pensive Bodhisattva of Bonghwa (봉화 북지리 석조반가상의 보존 및 받침대 안정성 평가)

  • Chae, Woomin;Jang, Minkyeong;Yi, Younghee;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • v.17
    • /
    • pp.85-100
    • /
    • 2016
  • The Bukji-ri Stone Pensive Bodhisattva of Bonghwa in the collection of Kyungpook National University Museum was transported to the National Museum of Korea for display in a special exhibition('Masterpieces of Early Buddhist Sculpture 100 BCE - 700 CE') and therefore underwent conservation ahead of the exhibition's start date. The stone sculpture had visibly encrusted surface dirt, granular disintegration and fissures upon arrival. Notably, a crack running obliquely across its lower half rendered the object unable to support its own weight without a pedestal, so one was created in order to maintain the sculpture in an upright position while on exhibition. The sculpture was further examined using a polarizing microscope and a stereoscopic microscope. SEM-EDS resulted in petrographic analysis of the stone's mineral composition and identification of its surface contaminants. Polarizing light microscopy confirmed biotite granite as the main mineral component of the object. Several urethane resins cast in round cross-sections were inserted into the newly made pedestal and stability tests were perform to measure the frictional force of the resins. An additional test was performed to compare urethane resin and epoxy resin, with results showing urethane to have a higher coefficient of friction. Utilizing a pedestal with urethane resin effectively ensured the stability of the Bukji-ri Stone Pensive Bodhisattva of Bonghwa during the aforementioned exhibition.

Failure Analysis of Corroded Coating Materials by Acoustic Emission (음향방출법에 의한 용사코팅 피막부식재의 파손 해석)

  • KIM GUI-SHIK;HYUN CHANG-HAE;HONG YONG-UI;SHON CHANG-HWAN
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.43-49
    • /
    • 2005
  • This paper is to investigate the effect of corrosion by acoustic emission method in tensile loading and the adhesiveness between substrate and coating layer. The powders used are Zn and Amdry625, respectively. They are coated on brass alloy substrate. AE signals of Zn and Amdry625 coating layer increase drastically in strain $2\%$. However, those of Zn specimen have more than those of Amdry625 specimen. When the specimens executed the corrosion test under $3.5\%$ NaCl solution for 500, 1000 hours, the salt solution penetrated into the surface of the substrate through the pores of the coating layer. As a result, corrosion production formed on the surface of the substrate. The adhesiveness between coating layers is weakened by the polarization and corrosion itself. The AE event, count, and energy of corroded coating specimens decrease, compared to specimens without corrosion. The results are summarized as follows : 1. In the tensile tests, the time that it took to start and develop the cracks and exfoliations between the surface of the substrates and the plasma spray coatings were different according to the type of plasma sprayed material, which are Zn and Amdry625. These phenomena were obvious at the strain rate 1 to $5\%$, and few available data were found after that stage. 2. The specimens with Zn coating showed the characteristics of crack, according to the changes of the tensile strength applied on the substrates while those with Amdry625 showed exfoliation as a result of low adaptation to the tensile strength. 3. The anti-corrosion specimens showed that the adhesive properties between the substrate and the plasma spray coating were strong in the order of Zn, Amdry. It showed that Corroded specimens cracked or exfoliated easily, even with the small energy, because those had a comparatively weakened adhesive property, due to corrosion. 4. Zn specimen showed no corrosion phenomena on the surface of the substrates, because they had the function of sacrifice anode however, Amdry625 specimen showed the corrosion, because it did not have that function.