• Title/Summary/Keyword: Crack ratio

Search Result 1,304, Processing Time 0.022 seconds

A Study on the Effect of Calcium-Chloride Content on the Strength of Mortar (염화(鹽化)칼슘의 함량(含量)이 Mortar의 강도(强度)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Sung, Chan-Yong;Kang, Sin-Up
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.2
    • /
    • pp.185-191
    • /
    • 1979
  • Compressive and tensile strengths of commonly being used mortar and mortar specially hardened by adding 1%, 2% and 3% of $CaCl_2$ were compared under the different mixing ratio of mortar and ages to investigate the effect of $CaCl_2$ which is being used as a promotor for coagulation and hardness, on the strength of mortar. The results obtained were as follows: 1. The compressive strength of mortar hardened by addition of $CaCl_2$ was higher than that of commonly being used mortar. The highest compressive strength of mortar was obtained when 2% of $CaCl_2$ were added. 2. The tensile strength of mortar, which was made by adding $CaCl_2$ and aged for seven days, was higher than that of commonly being used mortar. The highest tensile strength of mortar was obtained when 1% of $CaCl_2$ was added and aged for 28 days. And the tensile strength of mortar with 2% of $CaCl_2$ was lower than that of commonly being used mortar. 3. When the amount of $CaCl_2$ added was higher than 3%, the mortar was abruptly hardened and thereby occurred crack was considered lowering strength of mortar. 4. The rich mix was effective for the increasing the compressive and tensile strength before seven days of age and less effective after seven days of age. Therefore, the addition of one to two per cent of $CaCl_2$ would be effective for promoting initial strength of mortar during winter season.

  • PDF

Fiber Orientation Factor on a Circular Cross-Section in Concrete Members (콘크리트 원형단면에서의 섬유분포계수)

  • Lee, Seong-Cheol;Oh, Jeong-Hwan;Cho, Jae-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.307-313
    • /
    • 2014
  • In order to predict the post-cracking tensile behavior of fiber reinforced concrete, it is necessary to evaluate the fiber orientation factor which indicates the number of fibers bridging a crack. For investigation of fiber orientation factor on a circular cross-section, in this paper, cylindrical steel fiber reinforced concrete specimens were casted with the variables of concrete compressive strength, circular cross-section size, fiber type, and fiber volumetric ratio. The specimens were cut perpendicularly to the casting direction so that the fiber orientation factor could be evaluated through counting the number of fibers on the circular cross-section. From the test results, it was investigated that the fiber orientation factor on a circular cross-section was lower than 0.5 generally adopted, as fibers tended to be perpendicular to the casting direction. In addition, it was observed that the fiber orientation factor decreased with an increase of the number of fibers per unit cross-section area. For rational prediction of the fiber orientation factor on a circular section, a rigorous model and a simplified equation were derived through taking account of a possible fiber inclination angle considering the circular boundary surface. From the comparison of the measured data and the predicted values, it was found that the fiber orientation factor was well predicted by the proposed model. The test results and the proposed model can be useful for researches on structural behavior of steel fiber reinforced columns with a circular cross-section.

Rheological Evaluation of Blast Furnace Slag Cement Paster over Setting Time (고로슬래그 혼합 시멘트 페이스트의 응결시간 경과에 따른 레올로지 특성)

  • Cho, Bong-Suk;Ahn, Jae-Cheol;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.505-512
    • /
    • 2016
  • Even though high performance concrete was developed according to the trend of bigger and higher of reinforced concrete building, the rheological evaluations such as viscosity, yield stress are not enough to use as input data to accomplish the numerical analysis for the construction design. So there are many problems in the harden concrete such as poor compaction, rock pocket and crack, etc. in the field. In this study, consistency curves were measured by the viscometer as hydration reaction time passed. At the same time the slump flow test and Vicat setting test were carried out for comparing with the results of rheological properties. The fluidity of the W/B 30% decreased as the increase of replacement ratio of blast furnace slag. But in case of W/B 40%, the replacement ration did not significantly influenced to the slump flow value with the passage of hydration time. By the replacement of blast furnace slag to cement, initial setting was delayed and the time gap between initial and final setting became shorten. Through the regression analysis using Bingham model, there are a sudden changes of viscosity and yield stress around initial setting in case of low W/B 30%. The increase of workability by the change of free water in cement paste was offset by the coating effect of impermeable layer in case of W/B 40%.

Effects of Crack Resistance Properties of Ozone-treated Carbon Fibers-reinforced Nylon-6 Matrix Composites (탄소섬유의 오존처리가 나일론6 기지 복합재료의 크랙저항에 미치는 영향)

  • Han, Woong;Choi, Woong-Ki;An, Kay-Hyeok;Kim, Hong-Gun;Kang, Shin-Jae;Kim, Byung-Joo
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.363-369
    • /
    • 2013
  • In this work, the effects of ozone treatments on mechanical interfacial properties of carbon fibers-reinforced nylon-6 matrix composites were investigated. The surface properties of ozone treated carbon fibers were studied by Fourier transform infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy (XPS). Mechanical interfacial properties of the composites were investigated using critical stress intensity factor ($K_{IC}$). The cross-section morphologies of ozone-treated carbon fiber/nylon-6 composites were observed by scanning electron microscope (SEM). As a result, $K_{IC}$ of the ozone-treated carbon fibers-reinforced composites showed higher values than those of as-received carbon fibers-reinforced composites due the enhanced $O_{1s}/C_{1s}$ ratio of the carbon fiber by the ozone treatments. This result concludes that the mechanical interfacial properties of nylon-6 matrix composites can be controlled by suitable ozone treatments on the carbon fibers.

Effect of seaweed extracts(GA14), a plant growth regulator, on growth and yield of two rice cultivars (식물생장조절제 Seaweed extracts(GA14)의 수도 품종간 생육 및 수량에 미치는 효과)

  • Song, Jae-Young;Kim, Yong-Il;Park, Bo-Young;Jung, Jae-Young;Choi, Hyun-Gu;Jung, Jong-Tae;Lee, Hee-Bong
    • Korean Journal of Agricultural Science
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • This study was carried out to identify the effects of seaweed extracts(GA14) on growth of two rice cultivars, Junambyo and Donganbyo. Seedling qualities of two cultivars were better in all items including heading dates at early stage treated at seedling plus 2-3 leaf stages than at single treatment of seedling. Ripening ratio of Junambyo in paddy field was increased 0.3% by seaweed extracts(GA14) treatment, but that of Donganbyo decreased 0.5%. 1,000 grain weight of Junambyo and Donanbyo by seaweed extracts(GA14) treatment was two to four grams higher and the yield of two cultivars was also higher by three to four percent. Appearance characters of two rice cultivars was high in head, while damaged, chalky and crack rate were low at seaweed extracts(GA14) treatment. Protein, moisture and amylose characteristics related to table quality of Junambyo were not different by seaweed extracts treatment, but table values was high in only treatment. Donganbyo was also similar to Junambyo, but table quality was slightly high at non-treatment.

  • PDF

Flexural Strength Analysis of RC T-Beams Strengthened Using Fiber Sheets (섬유시트로 보강된 T형 철근콘크리트보의 휨 강도 해석)

  • Park, Tae-Hyo;Lee, Gyu-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.234-245
    • /
    • 2003
  • Most of the concrete bridge structures are exposed to damage due to the excessive traffic loading and the aging of the structure. The damage of concrete causes the further deterioration of the function in the concrete structure due to corrosion of the reinforced bars and decohesion between the concrete and the reinforced bar. The quick rehabilitation of the damaged concrete structures has become of great importance in the concrete structural system in order to avoid the further deterioration of the structures. Recently fiber sheets are used for strengthening the damaged concrete structures due to its many advantages such as its durability, non-corrosive nature, low weight, ease of application, cost saving, control of crack propagation, strength to thickness ratio, high tensile strength, serviceability and aesthetic. However, the lack of analytical procedures for assessing the nominal moment capacity by the fiber sheet reinforcement leads to difficulties in the effective process of decisions of the factors in the strengthening procedure. In this work, flexural strengthening effects by fiber sheets bonded on bottom face of the member are studied for the reinforced concrete T beam. In addition, auxiliary flexural strengthening effects by U-type fiber sheets bonded on bottom and side faces of the member to prevent delamination of the bottom fiber sheet are theoretically investigated. The analytical solutions are compared with experimental results of several references to verify the proposed approach. It is shown that the good agreements between the predicted results and experimental data are obtained.

Thermal property of geopolymer on fly ash-blast furnace slag system with the addition of alumina aggregate (알루미나 골재 첨가에 따른 플라이애쉬-고로슬래그계 지오폴리머의 열적특성)

  • Kim, Jin-Ho;Nam, In-Tak;Park, Hyun;Kim, Kyung-Nam
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.1
    • /
    • pp.47-56
    • /
    • 2017
  • In this study, the higher temperature thermal property of the fly ash-blast furnace slag system Geopolymer including alumina aggregate was investigated whether that Geopolymer will be or not useful as thermal-resistant construction materials. Under every mixing conditions, the crack on the surface of hardened body was not observed up to $800^{\circ}C$ and it corresponded with fact that level of changes was not significant before and after heating process. Residual compressive strength is most high when mixing Blast-Furnace Slag ratio is 60 wt% until temperature reaches $800^{\circ}C$. The major hydrates of hardened body of Geopolymer; amorphous halo pattern between $20{\sim}35^{\circ}$ (2theta) and mullite ($3Al_2O_3{\cdot}2SiO_2$) and quartz ($SiO_2$) was found during the experiment. Amorphous halo pattern was a aluminosilicate gel generated by geopolymeric polycondensation and it was found that the halo pattern of aluminosilicate gel was preserved up to $800^{\circ}C$. The patterns of aluminosilicate gel disappeared from $1,000^{\circ}C$ and crystal phases like gehlenite, calcium silicate, calcium aluminum oxide, microcline was observed with the increase of exposure temperature.

Quality Characteristics of Korean Red Ginseng Powder with Different Milling Methods (분쇄방법에 따른 고려홍삼분말의 품질특성)

  • 서창훈;이종원;도재호;김나미;양재원;장규원
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.3
    • /
    • pp.370-374
    • /
    • 2003
  • Cell cracking method using a non-collision was evaluated for the possibility of new red ginseng grinding technique. Based on particle size distribution analysis by 1size shaker, the ratios of 100 mesh penetrated particles were 94.9% for hammer mill (group A) and 95.6% for cell crack (group B). The ratio of 120 mesh penetrated particle of group A was higher than that in group B. The particle size distributions for 100 mesh non-penetrated Powder between 2 groups were not significantly different, and particle size distribution analysis by laser scattering analyzer showed that the particle size ranges were 0.77~128.07 ${\mu}{\textrm}{m}$ for group A and 4.24~180.07 ${\mu}{\textrm}{m}$ for group B. The Particle size distribution in group A was more broad than that in group B. The mean particle size in group B was larger than that in group A, while the standard deviation of particle size distribution in group B was less than that in group A. Structural surface characteristics, in group A, particle size distribution was broad and the distribution curve was amorphous. The structure of individual particles was similar to unequal stone which was roughly grinded and had soft cotton-like surface. In the contrary, in group B, particle size distribution was relatively narrow and also individual size particles were ubiquitously distributed. The structure of individual particles was unequal cut stone shape.

Scale Model Studies for Stability Estimation of Twin Tunnels with Small Clearance (근접병설터널의 안정성 평가를 위한 모형실험 연구)

  • Kim, Pyoung Gi;Kim, Jong Woo
    • Tunnel and Underground Space
    • /
    • v.23 no.2
    • /
    • pp.130-140
    • /
    • 2013
  • In this study, scaled model tests were performed to investigate the stability of twin tunnels with small clearance, where the pillar widths were 0.5D and 0.25D, respectively. The tunnels were supposed to be constructed in anisotropic weathered rocks with $30^{\circ}$ inclined bedding planes, and the model tests were conducted under the condition of lateral pressure ratio, 1. Six types of test models which had respectively different pillar widths and support conditions were experimented, where crack initiating pressures, maximum pressures, failure modes of pillar and deformation behaviors around tunnels were investigated. The models with wider pillar were cracked under higher pressure than the models with shallower pillar. The models with lining support were cracked under higher pressure and showed less tunnel convergence than the unsupported models. The models with both lining and pillar reinforcement were proved to be most stable among the tested models. In particular, as the model of 0.25D pillar width with only lining support showed shear failure of pillar according to the existing bedding planes, so both lining and pillar reinforcement were thought to be indispensable in that case of tunnel.

A Study on the Preparation of Aluina & Titania Sols for Coatings (코팅용 알루미타, 티타니아솔 제조에 관한 연구)

  • Kim, Chu-Hui;Choe, Hyeong-Su;Jo, Yeong-Sang;Im, Jong-Ju
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.319-328
    • /
    • 1994
  • Aluminium and titanium precursors containing $\beta$-diketonate ligands were used for the synthesis of polymeric sols of alumina and titania by sol-gel methods. To prepare polymeric sols by solgel processing, we synthesized modified precursors having chelating organic ligands. With these precursors it was found to be possible to control both hydrolysis and polycondensation reaction rates which resulted in ultrafine particles few nms of average size. The optimum molar ratio of acid to alkoxide for alumina sol was 0.3-0.4 and that of water to alkoxide &as 1. On the other hand, the corresponding ratios for titania sol were found be 0.25-0.20 and 1 respectively. Dynamic light scattering measurements indicated that the average particle size in both sols was in the order of few nms. SEM photographs were taken to observe crack-free and smooth surfaces of coated membranes after sintering at $450^{\circ}C$. Alumina coated membrane on a slide glass had about 4-4.5$\mu \textrm{m}$, thickness and titania coated one had 2-2.5$\mu \textrm{m}$, thickness. And according to TEM photographs, the grain size of titania was smaller than 30nm and that of alumina was in the range of few $\AA$s to 2nms. An X-ray diffraction study revealed that alumina was $\gamma$ phase and titania was anatase crystal.

  • PDF