• 제목/요약/키워드: Crack occurrence

검색결과 235건 처리시간 0.178초

축방향 다중관통균열이 존재하는 증기발생기 세관 평가법 (Assessment of Steam Generator Tubes with Multiple Axial Through-Wall Cracks)

  • 문성인;장윤석;김영진;이진호;송명호;최영환
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1741-1751
    • /
    • 2004
  • It is commonly requested that the steam generator tubes wall-thinned in excess of 40% should be plugged. However, the plugging criterion is known to be too conservative for some locations and types of defects and its application is limited to a single crack in spite of the fact that the occurrence of multiple through-wall cracks is more common in general. The objective of this research is to propose the optimum failure prediction models for two adjacent through-wall cracks in steam generator tubes. The conservatism of the present plugging criteria was reviewed using the existing failure prediction models for a single crack, and six new failure prediction models for multiple through-wall cracks have been introduced. Then, in order to determine the optimum ones among these new local or global failure prediction models, a series of plastic collapse tests and corresponding finite element analyses for two adjacent through-wall cracks in thin plate were carried out. Thereby, the reaction force model, plastic zone contact model and COD (Crack-Opening Displacement) base model were selected as the optimum ones for assessment of steam generator tubes with multiple through-wall cracks. The selected optimum failure prediction models, finally, were used to estimate the coalescence pressure of two adjacent through-wall cracks in steam generator tubes.

표면개량 버블시트 종류 변화가 서중환경 콘크리트의 온도 및 균열발생에 미치는 영향 (Effect of the Kind of Modified Bubble Sheets on the Temperature Profiles and Crack Reduction of the Concrete under Hot Weather)

  • 이상운;한민철
    • 한국건축시공학회지
    • /
    • 제18권3호
    • /
    • pp.251-257
    • /
    • 2018
  • 여름철 콘크리트는 수분증발에 의한 소성 및 건조수축균열, 슬럼프 저하, 콜드조인트 발생 등 다양한 문제가 발생한다. 이에 국내에서는 수분증발을 방지하고, 단열성능을 확보하기 위해 표면피복 양생을 위한 다양한 형태의 버블시트를 제작하여 사용하고 있으나, 여름철에는 적용사례가 없었다. 따라서 본 연구에서는 여름철 시공중인 아파트 현장에 1중의 투명, 백색 및 알루미늄 증착 버블시트와 PE필름 및 표면노출의 5가지 표면피복 양생재를 적용하여 콘크리트의 온도 및 균열특성 등 품질에 미치는 영향을 분석하였다. 실험결과 알루미늄 증착 버블시트가 온도저감, 균열저감 면에서 가장 뛰어난 것으로 나타났지만, 알루미늄 재질의 특성상 빛이 반사되어 시공자의 눈부심에 따른 시각공해가 발생하기 때문에 백색 버블시트의 사용이 가장 효과적인 것으로 밝혀졌다.

계장화한 긴 바를 사용한 세라믹판의 충격 파괴 거동 (Impact Fracture Behavior of Ceramic Plates Using Instrumented Long Bar)

  • 신형섭;오상엽;최수용;서창민;장순남
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.787-793
    • /
    • 2002
  • In this study, a bar impact test of low velocity was carried out to gain an insight into the damage mechanism and sequence induced in alumina plates(AD 85 and AD 90) under impact conditions. An experimental setup utilizing an instrumented long bar impact was devised, that can measure directly the impact force applied to the specimen and supply a compressive contact pressure to the specimen. During the bar impact testing, the influences of the contact pressure applied along the impact direction to the specimen on the fracture behavior were investigated. The measured impact force profiles explained well the damage behavior induced in alumina plates. The higher contact pressure to the specimen led to the less damage due to the suppression of radial cracks due to the increase in the apparent flexural stiffness of plate. It had produced the change of damage pattern developed in the specimen; from the radial cracks to the local contact stress dominant damage. It would contribute to the improvement of the ballistic property in ceramic plates. The observed results showed the following sequence in damage developed: The development of cone crack at impact region, the formation of radial cracks from the rear surface of plate depending on the plate thickness, the occurrence of crushing within the cone envelope and the fragmentation.

재생 PET 섬유가 혼입된 섬유 보강 콘크리트의 강도 및 균열저항 특성 (Strength and Crack Resistance Properties of Fiber Reinforced Concrete Mixed with Recycled PET Fiber)

  • 김성배;김현영;이나현;김장호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.102-108
    • /
    • 2010
  • 본 연구의 목적은 폐 PET병을 재활용하여 만든 섬유(RPET)를 콘크리트 부재에 적용시키기 위한 성능 평가에 있다. RPET 섬유보강 효과를 평가하기 위해서 압축강도, 탄성계수, 쪼갬인장강도와 같은 기초물성실험과 건조수축균열실험을 수행하였다. 기초물성실험에서 RPET의 혼입률이 증가할수록 RPET 보강 콘크리트의 압축강도와 탄성계수는 감소하였고, 쪼갬인장강도는 증가하였다. 건조수축 실험에서 자유건조수축은 증가하였다. 반면에 구속건조수축의 경우 RPET 섬유에 의한 인장 저항성의 증가로 인해 균열 발생을 지연시켰다. RPET 섬유와 PP 섬유를 혼입한 콘크리트 시편의 특성을 비교해보면 두 섬유가 유사하다는 것을 알 수 있다. 따라서 RPET 섬유는 PP 섬유의 대체 재료로서 충분할 뿐만 아니라 폐 PET병을 재활용하고 환경오염을 저감시킨다는 측면에서 친환경적으로 더 뛰어나다는 것을 알 수 있다.

원자로 내부구조물 균열개시 민감도에 미치는 영향인자 고찰 (Review of Factors Affecting IASCC Initiation of Stainless Steel in PWRs)

  • 황성식;최민재;김성우;김동진
    • Corrosion Science and Technology
    • /
    • 제20권4호
    • /
    • pp.210-229
    • /
    • 2021
  • To safely operate domestic nuclear power plants approaching the end of their design life, the material degradation management strategy of the components is important. Among studies conducted to improve the soundness of nuclear reactor components, research methods for understanding the degradation of reactor internals and preparing management strategies were surveyed. Since the IGSCC (Intergranular Stress Corrosion Cracking) initiation and propagation process is associated with metal dissolution at the crack tip, crack initiation sensitivity was decreased in the hydrogenated water with decreased crack sensitivity but occurrence of small surface cracks increased. A stress of 50 to 55% of the yield strength of the irradiated materials was required to cause IASCC (Irradiation Assisted Stress Corrosion Cracking) failure at the end of the reactor operating life. In the threshold-stress analysis, IASCC cracks were not expected to occur until the end of life at a stress of less than 62% of the investigated yield strength, and the IASCC critical dose was determined to be 4 dpa (Displacement Per Atom). The stainless steel surface oxide was composed of an internal Cr-rich spinel oxide and an external Fe and Ni-rich oxide, regardless of the dose and applied strain level.

철근부식으로 인한 지하철 박스구조물의 콘크리트 피복층 균열특성 분석 (Analysis of Crack characteristic on Concrete Cover for Subway Box Structure Due to Reinforcement Corrosion)

  • 최정열;신동섭;정지승
    • 문화기술의 융합
    • /
    • 제8권6호
    • /
    • pp.727-732
    • /
    • 2022
  • 도시철도 지하구조물에서 중요한 열화 중 하나인 철근부식은 철근의 부피 팽창에 의해 콘크리트의 피복층의 균열 또는 표면박리, 박락 등을 초래하여 철근콘크리트 구조물의 사용성과 안전성이 저하된다. 본 연구에서는 부식환경에서의 도시철도 지하박스 구조물을 대상으로 철근부식으로 인한 콘크리트 피복층의 균열발생 위치에서 철근의 팽창율을 측정하고 이를 바탕으로 철근부식으로 인한 콘크리트 피복층 들뜸 및 손상에 대한 분석을 수행하였다. 부식된 철근의 방사형 변위 분포 모델을 산출하고 기존 제안식과 비교, 분석하였다. 또한 대표 단면을 대상으로한 수치해석(역해석)을 수행하여 부식철근의 방사형 변위장에 의한, 철근의 불균일한 부식팽창을 해석모델에 적용하였다. 수치해석 결과를 바탕으로 철근부식율 진전에 따른 철근콘크리트 구조물의 균열 및 피복층 박리의 영향을 해석적으로 도출하고 현장 시료와의 비교를 통해 수치모델의 적정성을 입증하였다.

실동이력에 기초한 곡선거더교의 피로균열 특성 및 분석 (Characteristic and Analysis of Fatigue Crack for Curved Girder Bridge based on the Stress Range Histerisis)

  • 권순철;경갑수;김대용;이해성
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.1-13
    • /
    • 2008
  • 곡선거더교의 복부는 교축방향의 면내응력과 면외 휨응력을 동시에 받는 구조이므로, 직선교에 비하여 플랜지와 복부의 필릿용접이음부에서의 발생응력이 상당히 크며, 또 바닥틀이나 브레이싱을 주거더에 연결시켜주는 거셋플레이트는 구조적으로 더욱 취약한 구조가 된다. 본 연구에서는 23년간 공용된 곡선거더교에서 발생된 피로균열의 발생원인을 조사하기 위하여 실제교통 흐름 하에서의 용접부에서의 응력특성을 파악하기 위하여 일련의 현장측정을 실시하였다. 이들 현장측정으로부터 여러 가지 타입에 대한 피로균열 원인을 분석하였고, 또한 주요 균열에 대한 피로수명을 평가하였다. 또한 곡선거더교 용접이음부의 구조거동 특성을 조사하기 위하여 유한요소해석을 실시하고 이들 결과를 현장측정결과와 비교분석하였다.

종방향균열 영향인자 분석을 통한 NATM터널 정밀안전진단 상태평가 항목의 재검토 (A re-appraisal of scoring items in state assessment of NATM tunnel considering influencing factors causing longitudinal cracks)

  • 추진호;유창균;오영철;이인모
    • 한국터널지하공간학회 논문집
    • /
    • 제21권4호
    • /
    • pp.479-499
    • /
    • 2019
  • 공용중인 터널의 조사 및 평가는 시설물안전법의 안전점검 및 정밀안전진단 세부지침(터널)편에 따라 외관조사와 내구성조사를 근거하여 상태평가를 수행하고 있다. 본 연구에서는 종방향균열의 발생요인 파악을 위해 준공 후 10년이 경과되어 최초 정밀안전진단이 실시된 NATM터널 12개에 대해 균열과 라이닝의 두께를 검토하여, 이를 반영한 상태평가 수정사항을 모색하였다. 종방향균열에 대한 굴착지반의 영향을 검토하기 위해 지보패턴, 이를 구성하는 지보재 시공 조건, 라이닝의 재료적 특성, GPR탐사를 통한 라이닝 두께 등을 터널 형상 및 용도에 따라 4개의 그룹으로 나누어 자료를 분석하였다. 균열발생밀도는 숏크리트, 록볼트, 강지보재의 지보재 지지능력에 따라 변화되나 굴착지보패턴에 따른 균열발생과의 연관성은 낮은 것으로 나타났다. 라이닝 재료적인 특징인 물-시멘트비, 시멘트함유량, 강도 등이 균열발생에 영향을 주는 것으로 나타났다. 또한, GPR탐사의 라이닝 두께를 반영한 상태평가에서는 평균 0.03 정도(분포, 0.001~0.071)의 점수증가를 야기하는 것으로 확인되어 향후 라이닝 두께 부족을 고려하는 현실적인 상태평가 방안에 대한 검토가 필요하다.

무근 콘크리트포장 초기균열 거동 연구 (Behaviors of Early-Age Cracks on the JCP)

  • 박대근;서영찬;안성순;김형배
    • 한국도로학회논문집
    • /
    • 제6권2호
    • /
    • pp.47-59
    • /
    • 2004
  • 콘크리트포장에 초기균열을 일으키는 중요한 인자 중 하나는 콘크리트 내부의 초기온도이다. 따라서 콘크리트포장의 초기균열 발생원인을 연구하기 위해서는 초기온도를 계측하여 분석하는 일이 필요하다. 본 논문에서는 초기균열이 발생하는 슬래브 장소와 초기균열의 발생시간이 초기온도패턴에 어떤 영향을 받는지를 검증하였고 더불어, 줄눈부에서 발생하는 균열의 발생시점과 시공시간과의 관계도 알아보았다. 본 논문을 위해서 "중부내륙고속도로 여주-충주간 제 1공구 시험도로 건설공사구간 STATION 1+400$\sim$1+700" 지점에서 시험시공이 이루어졌으며, 시공 후 72시간 동안 i-Button(온도계측센서)을 이용하여 온도계측을 시행하였으며, 초기균열의 거동은 Demec gauge를 사용하였으며, 초기균열 및 줄눈부 균열은 육안으로 확인하였다. 초기온도패턴과 초기균열의 분석 결과, 콘크리트의 초기온도패턴은 슬래브에 초기균열이 발생하는 위치와 시각에 영향을 주는 것으로 나타났다 초기균열균열은 온도낙차폭이 가장 큰 슬래브에서 발생하였으며, 그 시각은 슬래브의 온도가 급강하하는 새벽이었다. 또한, 콘크리트 슬래브의 거동이 인근 줄눈부에 발생한 초기균열에 따라 영향을 받으며. 줄눈부에 발생한 균열의 발생시기가 서로 다를 경우에 균열의 거동이 달라질 수 있다는 가능성이 제시되었다. 그 외에도, 오전에 시공한 슬래브에서의 균열 발생률이 오후에 시공한것보다 더 큰 것으로 나타났으며, 균열의 발생 간격이 큰 균열이 그렇지 않은 균열보다 더 큰 균열틈을 보였다.

  • PDF

내부구속에 의한 수화열 균열의 개선된 평가 방법 (An Advanced Assessment Strategy of Thermal Cracks Induced by Hydration Heat and Internal Restraint)

  • 전세진;최명성;김영진
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.677-685
    • /
    • 2006
  • 수화열 균열 저감 기법 중 내부구속이 지배적인 구조물에서 단면의 내외부 온도차를 관리하는 방식은 그 활용도가 매우 높다. 그러나 현 국내 기준의 내외부 온도차와 온도균열지수 관계식은 균열 발생 가능성을 과대평가하는 경향이 있다. 본 연구에서는 그러한 평가식이 유도된 배경을 단계별로 추적하여 타당성을 검증해 보았으며, 그 결과 재령에 따른 탄성계수의 변동성이 고려되지 않은 단순한 재료모델을 사용한 경우에 해당됨을 밝혔다. 개선된 재료모델로 증분형태 구성방정식인 hypoelastic 모델을 사용한 결과 온도균열지수가 기존 식보다 증가되었으며, 그 증가량은 다양한 조건들에 의존하는 것으로 나타났다. 본 연구의 분석 결과와 해외사례를 참조하여 평가식의 개선된 형태를 고찰하였으며 또한 평가시 필요한 내외부 온도차를 시공 조건들의 영향을 고려하여 용이하게 추정할 수 있는 식도 제안하였다. 추후 해석 및 실험 자료가 축적되면 구조물과 배합의 주요 특징들을 반영하여 평가식을 세분화하는 것도 바람직하다고 생각된다.