• Title/Summary/Keyword: Cr Loading

Search Result 146, Processing Time 0.029 seconds

Stiffness Reduction Factor for Flat Plate Slabs (플랫 플레이트 슬래브 해석을 위한 강성감소계수 제안)

  • Park, Young-Mi;Han, Sang-Whan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.337-340
    • /
    • 2006
  • The purpose of this study is to propose the stiffness reduction factor for flat plate slabs under lateral loads. Current design code (e.g., ACI 318-05) requires considering the effects of cracks for calculating slab stiffness under lateral loads. This study collected the test results of 20 interior slab-column connections, from which stiffness reduction in each test was estimated with respect to the ratio of applied moment to cracking moment ($M_a/M_{cr}$). Based on collected data, this study proposed equations for calculating stiffness reduction with respect to $M_a/M_{cr}$. To verify the proposed equations, this study conducted the experimental test of interior slab-column connections under quasi-static cyclic loading. From the test, load-deformation curve is compared to that obtained from effective beam width method with the proposed equation for the stiffness reduction. It is shown that the effective beam width method with the proposed equation for stiffness reduction predicts accurately the test results.

  • PDF

The selection criteria of temporary or permanent luting agents in implant-supported prostheses: in vitro study

  • Alvarez-Arenal, Angel;Gonzalez-Gonzalez, Ignacio;deLlanos-Lanchares, Hector;Brizuela-Velasco, Aritza;Ellacuria-Echebarria, Joseba
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.144-149
    • /
    • 2016
  • PURPOSE. The use of temporary or permanent cements in fixed implant-supported prostheses is under discussion. The objective was to compare the retentiveness of one temporary and two permanent cements after cyclic compressive loading. MATERIALS AND METHODS. The working model was five solid abutments screwed to five implant analogs. Thirty Cr-Ni alloy copings were randomized and cemented to the abutments with one temporary (resin urethane-based) or two permanent (resin-modified glass ionomer, resin-composite) cements. The retention strength was measured twice: once after the copings were cemented and again after a compressive cyclic loading of 100 N at 0.72 Hz (100,000 cycles). RESULTS. Before loading, the retention strength of resin composite was 75% higher than the resin-modified glass ionomer and 2.5 times higher than resin urethane-based cement. After loading, the retentiveness of the three cements decreased in a non-uniform manner. The greatest percentage of retention loss was shown by the temporary cement and the lowest by the permanent resin composite. However, the two permanent cements consistently show high retention values. CONCLUSION. The higher the initial retention of each cement, the lower the percentage of retention loss after compressive cyclic loading. After loading, the resin urethane-based cement was the most favourable cement for retrieving the crowns and resin composite was the most favourable cement to keep them in place.

Removal of Synthetic Heavy Metal ($Cr^{6+}$, $Cu^{2+}$, $As^{3+}$, $Pb^{2+}$) from Water Using Red Mud and Lime Stone (적니와 석회석을 이용한 혼합 중금속($Cr^{6+}$, $Cu^{2+}$, $As^{3+}$, $Pb^{2+}$)의 제거)

  • Kang, Ku;Park, Seong-Jik;Shin, Woo-Seok;Um, Byung-Hwan;Kim, Young-Kee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.566-573
    • /
    • 2012
  • This study examined the removal rate of heavy metals from synthetic control water using red mud and lime stone. Overall, the percent of absorption obtained in this study for the red mud treatment was 94.0% ($Pb^{2+}$), 67.1% ($As^{3+}$), 37.5% ($Cu^{2+}$), and 36.6% ($Cr^{6+}$), while that of lime stone was $Pb^{2+}$ (30.8%), $Cu^{2+}$ (16.5%), $Cr^{6+}$ (11.5%), and $As^{3+}$ (8.9%). The kinetic data presented that the slow course of adsorption follows the Pseudo first and second order models, the equilibriuim adsorption of $Cr^{6+}$ and $Pb^{2+}$ obeys Freundlich isotherm model, while the adsorption of $Cu^{2+}$ obeys only Langmuir model. The results also showed that adsorption rate slightly increased with increasing pH from 5 to 9. Interestingly, this trend is similar to results obtained as function of loading amount of red mud. Meanwhile, an unit adsorption rate was slightly decreased. For lime stone, it did not much change in adsorption as function of treatment amount. Consequently, it was concluded that the absorbents can be successfully used the removal of the heavy metals from the aqueous solutions.

Development of Hip Joint Simulator to Evaluate The Wear of Biomaterials Used in Total Hip Joint Replacement (인공고관절 생체재료 마멸평가를 위한 시뮬레이터 개발)

  • 이권용;윤재웅;전승범;박성길
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.265-270
    • /
    • 2001
  • Hip joint simulator which Is an essential device for evaluating the wear of biomaterials (ultrahigh molecular weight polyethylene, Co-Cr alloy, alumina, etc.) used in total hip joint replacement was developed. This hip joint simulator mimics the joint motion and joint loading of human gait by adapting the 4 degree of freedom in kinematic motion (flexing/extension, adduction/abduction, Internal rotation/external rotation) and axial loading, Four stations are operated by 8 servo-motors and harmony drives. Joint leading was imposed by displacement control from a ball screw, LM guide, and spring system. Each kinematic link system operates separately or coupled modes. A heater and a thermocouple were installed for keeping the body temperature in each station.

  • PDF

PERFORMANCE OF TWO-PHASE UASB REACTOR IN ANAEROBIC TREATMENT OF WASTEWATER WITH SULFATE

  • Oh, Sae-Eun
    • Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.8-15
    • /
    • 2007
  • Two phase UASB reactors for treating wastewater with sulfate were operated to assess the performance and competition of organics between sulfate reducing bacteria(SRB) and methane producing bacteria(MPB), and the change of characteristics of microorganisms. The reactors were fed in parallel with a synthetic wastewater of 4,000-5,000 mgCOD/L and sulfate concentration of $800-1,000\;mgSO_4/L$. In the MPR(methane producing reactor) and CR(control reactor), COD removal efficiencies were 90% and 60%, respectively, at the OLR(organic loading rate) of 6 gCOD/L, while the amount of biogas and methane content were 6.5 L/day and 80%, and 3 L/day and 50%, respectively. However, the portion of electron flow used by SRB at the OLR of 6 gCOD/L day in MPR and CR was 3% and 26%, respectively. This indicated that the increase of OLR of wastewater containing high sulfate like CR resulted in activity decrease and cell decay of MPB, while SRB was adapted immediately to new environment. The MPB activities in MPR and CR were 2 and $0.38\;kgCH_4-COD$/gVSS day at the OLR of 6 gCOD/L. This indicated hat SRB dominated gradually over MPB during long-term operation with wastewater containing sulfate as a consequence of outcompeting of SRB over MPB. In addition, the solution within AFR was maintained around pH 5.0, the MPB such as Methanothrix spp. which was very important to formation of granules was detached from the surface of granules due to the decrease of activity by limitation of substrate transportation into MPB. Therefore, a significant amount of sludge was washed out from the reactor.

Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials (대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구)

  • Park, Young-Bae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

Characteristics of Pollutant Loading from Paddy Field Area with Groundwater Irrigation (지하수 관개지역 논에서의 배출부하 특성)

  • 윤춘경;김병희;전지홍;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.5
    • /
    • pp.116-126
    • /
    • 2002
  • Discharge pattern and water quality were investigated in the drainage water from about 10 ha of groundwater-irrigated paddy field in the growing season of 2001. Total discharge quantity was about 1,117.2 mm in which about 75% was caused by management drainage due to cultural practice of paddy rice farming and the rest by rainfall runoff where total rainfall was about 515 mm. Dry-day sampling data showed wide variations in constituent concentrations with average of 26.14 mg/L, 0.37 mg/L, 3.54 mg/L at the inlet, and 43.60 mg/L, 0.34 mg/L, 3.58 mg/L at the outlet for CO $D_{cr}$ , T-P, and T-N, respectively. Wet-day sampling data demonstrated that generally CO $D_{cr}$ followed the discharge pattern and T-P was in opposite to the discharge pattern, but T-N did not show apparent pattern to the discharge. Discharge and load are in strong relationship. And based on regression equation, pollutant loads from groundwater irrigation area are estimated to be 288.34, 1.17, and 5.45 kg/ha for CO $D_{cr}$ , T-P, and T-N, respectively, which was relatively lower than the literature value from surface water irrigation area which implies that groundwater irrigation area might use less irrigation water and result in less drainage water, Therefore, total pollutant load from paddies irrigation with groundwater could be significantly lower than that with surface water. This study shows that agricultural drainage water management needs a good care of drainage outlet as well as rainfall runoff. This study was based on limited monitoring data of one year, and further monitoring and successive analysis are recommended for more generalized conclusion.

Index of Organic Matter in Stream and Lake (하천·호소의 유기물 지표 평가)

  • Yu, Soon Ju;Hwang, Jong Yeon;Yoon, Young Sam;Cheon, Se Uk;Han, Eui Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.81-92
    • /
    • 1999
  • This study discussed the appropriateness of organic matter indexes such as biochemical oxygen demand(BOD) and chemical oxygen demand with potassium permanganate($COD_{Mn}$) in water quality environmental standard of streams and lakes and the applicability of the items to water quality environmental standard to add or substitute COD with potassium dichromate ($COD_{Cr}$) and total organic carbon(TOC) being used as index of organic matter. And indexes of organic matter content and organic carbon concentration were distinguished between dissolved and particulate component in water sample to estimate their effect on pollutants loading in lake and stream. The ratio of $COD_{Cr}$/BOD was 5.1 under BOD concentration 3mg/L in river water quality environmental standard II, and 2.67 above it. This ratio was diminished to 2.04 when BOD concentration was more than 8mg/L, in river quality environmental standard IV. Also the ratio of $COD_{Mn}$/BOD showed 2.16 under 3mg/L(BOD), and 1.1 above it. This ratio is also diminished to 0.84 over 8mg/L(BOD). Accordingly, we should apply this ratio depending on the concentration level to add and change organic matter index of water quality environmental standard newly. The ratio $COD_{Cr}/COD_{Mn}$ both in lake and stream shows 2.37(r=0.986, p<0.001). But the ratios showed range of 2.34~2.50, which is no much difference of this ratio according to $COD_{Mn}$ concentration.

  • PDF

Fatigue Damage Evaluation of Cr-Mo Steel with In-Situ Ultrasonic Surface Wave Assessment (초음파 시험에 의한 배관용 Cr-Mo강의 피로손상의 비파괴평가)

  • Kim, Sang-Tae;Lee, Hei-Dong;Yang, Hyun-Tae;Choi, Young-Geun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.1
    • /
    • pp.32-38
    • /
    • 2001
  • Although the ultrasonic method has been developed and used widely in the fields, it has been used only for measuring the defect size and thickness loss. In this study, the relationship between surface wave attenuation through micro-crack growth and variation of velocity under repeated cyclic loading has been investigated. The specimens are adopted from 2.25Cr-1Mo steel, which is used for power plant and pipeline system, and have dimensions of $200{\times}40{\times}4mm$. The results of ultrasonic test with a 5MHz transducer show that surface wave velocity gradually decreases from the point of 60% of fatigue life and the crack length of 2mm with the increasing fatigue cycles. From the results of this study, it is found that the technique using the ultrasonic velocity change is one of very useful methods to evaluate the fatigue life nondestructively.

  • PDF

Observation of Fatigue Crack Growth Behavior in 1Cr-1Mo-0.25V Steel Using Image Processing Technology (영상처리기법을 이용한 1Cr-1Mo-0.25V 강의 피로균열 성장거동 관찰)

  • Nahm, Seung-Hoon;Kim, Yong-Il;Ryu, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.14-21
    • /
    • 2002
  • The development of a new experimental method is required to easily observe the growth behavior of fatigue cracks. To satisfy the requirement, an image processing technique was introduced to fatigue testing. The length of surface fatigue crack could be successfully measured by the image processing system. At first, the image data of cracks were stored into the computer while the cyclic loading was interrupted. After testing, crack length was determined using an image processing software which was developed by authors. Various image processing techniques like a block matching method was applied tc the detection of surface fatigue cracks. By comparing the data measured by the image processing system with those by the manual measurement with a microscope, the effectiveness of the image processing system was established. If the proposed method is used to monitor and observe the crack growth behavior automatically, the time and efforts for fatigue test could be dramatically reduced.