• Title/Summary/Keyword: Cr(VI)

Search Result 218, Processing Time 0.025 seconds

Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter (Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가)

  • Shin, Yong Chul;Oh, Se Min;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF

Diffusion of Cr(VI) in Porous Media (심층 지하에서의 육가 크롬 확산)

  • 현재혁
    • The Journal of Engineering Geology
    • /
    • v.3 no.2
    • /
    • pp.203-214
    • /
    • 1993
  • Underground Injection Control regulations for Class I injection wells require that the vertical dufusion be considered as a mechanism for transport of contaninants in evaluating containment Due to the low permeability in the confining aquitard, the movement of contaminants over the long term is controlled by the molecular diffusion. The movement can be predicted, using the Fick' S second law of diffusion. The diffusion coefficient in Fick' s law has been determined experimentally in this study. Instantaneous injection of $^{51}Cr$ was used to trace the distribution of Cr(VI) in soil plugs and an analytical solution was applied to calculate the diffusion coefficients. This study shows the effect of environmental factors, such as temperature, chloride concentration, applied amount of $^{51}Cr$, and bulk density of injection formations on diffusion of Cr(VI)

  • PDF

Application of Organized Media for Rapid Spectrofluorimetric Determination of Trace Amounts of Cr(VI) in the Presence of Cr(III)

  • Madrakian, Tayyebeh;Afkhami, Abbas;Mohammadnejad, Masoumeh
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1252-1256
    • /
    • 2009
  • A simple, selective and sensitive fluorescence quenching method was developed to the determination Cr(VI). The method is based on the oxidation of $I^-\;to\;{{I_3}^-}$ by Cr(VI) in sulfuric acid solution followed by immediate formation of ion association compound between I3 − and rhodamine 6G in Tween-80 micellar media at room temperature. The influence of several surfactants on rhodamine 6G fluorescence signal was studied; particular attention was paid in the aggregation behavior of rhodamine 6G–Tween-80 system. The experimental parameters (e.g., type of surfactant, reagent concentration) were studied and the optimal conditions were established. The linear calibration graph was obtained in the range 2.0 - 100.0 ng m$L^{-1}$ Cr(VI). The detection limit of the method was 0.37 ng m$L^{-1}$. The relative standard deviation (R.S.D.) is less than 5% (n = 5). The efficiency of the method for the determination of Cr(VI) in the presence of Cr(III) in the sample was investigated. The method was applied successfully to the determination of Cr(VI) and total Cr in water, and liver tissue samples.

Welder's Exposure to Airborne Hexavalent Chromium and Nickel during Arc Welding in a Shipyard (모 조선업체 아크 용접 작업자의 공기중 6가 크롬 및 니켈 노출에 관한 연구)

  • Shin, Yong Chul;Yi, Gwang Yong;Lee, Na Roo;Oh, Se Min;Kang, Seong Kyu;Moon, Young Hahn;Lee, Ki Ra
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.209-223
    • /
    • 1998
  • The aim of this study was to evaluate welders' exposure to hexavalent chromium (Cr(VI)) and nickel (Ni) during welding operations in a Korean shipyard. The airborne Cr(VI) and Ni concentrations were measured during metal inert gas (MIG) welding on mild and stainless steel, and manual metal arc (MMA) welding on mild steel. The geometric mean (GM) of Cr(VI) concentrations inside the welding helmet during MIG welding on mild steel were $0.0018mg/m^3$ inside a ship section, and $0.0015-0.0026mg/m^3$ at the welding shops. All of the personal breathing zone air samples were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$) of $0.01mg/m^3$. Conversely, eighty-eight percent(21 of 24) of the personal breathing zone air samples exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit of $0.001mg/m^3$. Ni was not detected on 20 of 23 air samples collected during MIG welding on mild steel. The three Ni samples above the limit of detection ranged from 0.015 to $0.044mg/m^3$. The GM of Cr(VI) concentrations during MMA welding on mild steel were $0.0013mg/m^3$, but Ni was not detected in the air samples during this operation. It is assumed that the airborne Cr(VI) and Ni during mild steel welding were derived from the base metals which contained about 0.03% Cr and 0.03% Ni. The GM of airborne total Cr, Cr(VI) and Ni concentrations during MIG welding on stainless steel were 4.02, 0.13 and $0.86mg/m^3$, respectively, and the levels of Cr(VI) and Ni were above the ACGIH-$TLV^{(R)}$. Cr(VI) comprised about 35.5% of the total chromium(Cr) from MIG welding on mild steel, and about 8.4% of total Cr from MIG welding on stainless steel. The ratios of Cr(VI) to total Cr were significantly different among welding shops. It was concluded that welders were exposed to high levels of Cr(VI) and Ni during welding on stainless steel, and were exposed to low levels of Cr(VI) even during welding on mild steel.

  • PDF

Facilitated Transport of Cr(VI) through a Supported Liquid Membrane with a Carrier

  • Park, Sang-Wook;Lee, Jae-Wook;Kim, Sung-Soo;Choi, Byoung-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.154-164
    • /
    • 2003
  • This paper has applied a simple model to the mass transfer mechanism of Cr(VI) with crownether in a batch-type, supported liquid membrane module. Concentration at pH 3 are as follows : 0.012 kmol/$m^3{\le}$18-crown-6${\le}$0.036 kmol/$m^3$ and 20 g/$m^3{\le}$ Cr(VI)${\le}$500 g/$m^3$. The measured values of forward- and backward-reaction rate constants between Cr(VI) and 18-crown-6 were used to simulate the model with the mass conservation equation and associated boundary conditions. Comparison between the experimental and simulated facilitated factor of Cr(VI) transport led to classification of reaction regions.

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

Photocatalytic Cr(VI) Reduction with a Photoanode for Hydrogen Production (수소제조용 광전극을 활용한 Cr(VI) 환원처리에 관한 연구)

  • Shim, Eun-Jung;Park, Youn-Bong;Bae, Sang-Hyun;Yoon, Jae-Kyung;Joo, Hyun-Ku
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.4
    • /
    • pp.452-457
    • /
    • 2007
  • Titanium foil and mesh(anodized tubular $TiO_2$ electrode, ATTE) were anodized in a bath at $5^{\circ}C$ with 20V external bias applied, then annealed at different temperatures($450^{\circ}C{\sim}850^{\circ}C$) to obtain tubular $TiO_2$ on the Ti substrate. The prepared sample was used to investigate rate of hydrogen production as well as Cr(VI) reduction. The ATTEs annealed at relatively lower temperatures showed higher activity than those at relatively higher temperatures. In particular, the Cr(VI) reduction was pH-dependent. To improve photocatalytic Cr(VI) reduction with the ATTEs, two configurations, fixing foil type and rotating mesh type, were also compared. As a result, the rotating mesh type was much more effective for Cr(VI) reaction than the former due to the more efficient use of the light. In the rotating type reactor, as the rotating speed increased, the rate of the Cr(VI) reduction was getting faster.

Ni Nanoparticle-Graphene Oxide Composites for Speedy and Efficient Removal of Cr(VI) from Wastewater

  • Wang, Wan-Xia;Zhao, Dong-Lin;Wu, Chang-Nian;Chen, Yan;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.31 no.6
    • /
    • pp.345-352
    • /
    • 2021
  • In this study, Ni nanoparticle supported by graphene oxide (GO) (Ni-GO) is successfully synthesized through hydrothermal synthesis and calcination, and Cr(VI) is extracted from aqueous solution. The morphology and structure of Ni-GO composites are characterized by scanning electron microscopy (SEM), trans mission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). High-resolution transmission electron microscopy (HRTEM) and XRD confirms the high dispersion of Ni nanoparticle after support by GO. Loading Ni on GO can obviously enhance the stability of Ni-GO composites. It can be calculated from TGA that the mass percentage of Ni is about 60.67 %. The effects of initial pH and reaction time on Cr(VI) removal ability of Ni-GO are investigated. The results indicate that the removal efficiency of Cr(VI) is greater than that of bared GO. Ni-GO shows fast removal capacity for Cr(VI) (<25 min) with high removal efficiency. Dynamic experiments show that the removal process conforms to the quasi-second order model of adsorption, which indicates that the rate control step of the removal process is chemical adsorption. The removal capacity increases with the increase of temperature, indicating that the reaction of Cr(VI) on Ni-GO composites is endothermic and spontaneous. Combined with tests and characterization, the mechanism of Cr(VI) removal by rapidly adsorption on the surface of Ni-GO and reduction by Ni nanoparticle is investigated. The above results show that Ni-GO can be used as a potential remediation agent for Cr(VI)-contaminated groundwater.

Studies on the Selective Separation and Preconcentration of Cr(VI) Ion by XAD-16-Chromotropic Acid Chelating Resin (XAD-16-Chromotropic Acid 킬레이트 수지에 의한 몇 가지 금속이온의 선택적 분리 및 농축에 관한 연구)

  • Lee, Won;Lee, Chang-Youl;Kim, Mi-Kyoung;Kim, In-Whan
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.199-210
    • /
    • 2004
  • A new polystyrene-divinylbenzene chelating resin containing 4,5-dihydroxy-naphthalene-2,7-disulfonic acid (chromotropic acid : CTA) as functional group has been synthesized and characterized. The sorption and desorption properties of this chelating resin for Cr(III) ion and Cr(VI) ion including nine metal bloodstain. As a results, FOB test kit could be effectively applied to identification of human blood at chelating resin was stable in acidic and alkaline solution. The Cr(VI) ion is selectively separated from Cr (III) ion at pH 2 and the maximum sorption capacity of Cr(VI) ion is 1.2 mmol/g. In the presence of anions such as $F^-$, $SO{_4}^{2-}$, $CN^-$, $CH_3COO^-$, $NO{_3}^-$, the sorption of Cr(VI) ion was reduced but anions such as $PO{_4}^{3-}$ and $Cl^-$ revealed no interference effect. The elution order of metal ions obtained from breakthrough capacity and overall capacity at pH 2 was Cr(VI)>Sn(II)>Fe(III)>Cu(II)>Cd(II)${\simeq}Pb(II){\simeq}Cr(III){\simeq}Mn(II){\simeq}Ni(II){\simeq}Al(III)$. Desorption characteristics for Cr(VI) ion was investigated with desorption agents such as $HNO_3$, HCl, and $H_2SO_4$. It was found that the ion showed high desorption efficiency with 3 M HCl. As the result, the chelating resin, XAD-16-CTA was successfully applied to separation and preconcentration of Cr (VI) ion from several metal ions in metal finishing works.

Simultaneous Removal of Lead and Cr(VI) Using Chemically Combined Materials, ZanF (Zeolite anchored Fe) (ZanF (Zeolite anchored Fe)를 이용한 납과 Cr(VI)의 동시제거)

  • Lee, Seung-Hak;Lee, Kwang-Hun;Park, Jun-Boum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.185-188
    • /
    • 2003
  • 오염된 지하수 정화에 있어 반응벽체(Permeable Reactive Barriers, PRBs)를 이용한 정화기법은 최근 가장 큰 관심을 모으고 있는 기술이다. 반응벽체의 적용에 있어 가장 중요한 사항은 오염물질의 특성을 고려하여 적절한 반응성을 가지는 충진물질을 선택하는 일이다. 지금까지 연구된 반응물질 중 제올라이트는 취득이 용이하고 가격이 저렴하여, 암모늄이나 중금속과 같은 양이온성 오염물질의 정화에 그 적용성을 인정받아왔다. 하지만 표면에 음전하를 띠는 제올라이트의 특성 때문에, 지하수내에서 음이온의 형태로 존재하는 Cr(VI) 등에는 반응성이 없는 것으로 알려져 왔다. 이에 본 연구에서는 제올라이트에 영가철을 결합한 ZanF란 물질을 개발하여 양이온성 중금속의 하나인 납과 음이온성 중금속의 하나인 Cr(VI)을 동시 제거하는 실험을 수행하였다. 실험결과 ZanF는 초기농도 2-15mmol를 가지는 납 오염용액에 대해 90% 이상의 제거율을 보였으며, 초기농도 0.1 mmol을 가지는 Cr(VI) 오염용액의 농도를 5시간 내에 검출한계 이하로 떨어뜨리는 탁월한 효과를 보였다. 실험결과를 토대로 ZanF는 납과 Cr(VI)으로 동시에 오염된 지하수 정화에 효과적으로 사용될 수 있으리라 기대된다.

  • PDF