• Title/Summary/Keyword: Cr(VI)환원

Search Result 36, Processing Time 0.023 seconds

Study on photoactivity of anodized $TiO_2$ photoanode used of organic electrolyte for development of photocurrent (광전류 향상을 위한 유기 전해질 활용 양극산화 된 $TiO_2$ 전극의 광활성 연구)

  • Shim, Eun-Jung;Heo, Ah-Young;Park, Min-Sung;Yoon, Jae-Kyung;Joo, Hyun-Ku
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.222-225
    • /
    • 2009
  • In this paper, $TiO_2$ nanotube is prepared and the preparation is influenced by electrochemical etching rate and chemical dissolution rate. Especially, the chemical dissolution rate is lowered as the length $TiO_2$ nanotube increases. Titanium foil were anodized at various bias or current such as 20V, 55V and 0.1A (bath temperature $25^{\circ}C$) in organic electrolytes (ethylene glycol, glycerol) and then annealed at $450^{\circ}C$ and $650^{\circ}C$ to obtain the crystallized tubular $TiO_2$ on the Ti foil. Higher efficiency (89.1%) for the Cr(VI) reduction was obtained with the prepared sample compared to that (20.9%) with the sample in 0.5% HF electrolyte earlier studied.

  • PDF

Simultaneous Spectrophotometric Determination of Cr(Ⅲ) and Cr(Ⅳ) in Chromium Plating Solution via Flow-Through Analysis (흐름계를 이용한 크롬도금 용액의 Cr(Ⅲ)와 Cr(Ⅵ)의 분광학적 동시 분석 방법)

  • Kim, Sun Kwan;Nam, Hakhyun;So, Jae Chun;Lee, Won;Cha, Geun Sig;Han, Sang Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.2
    • /
    • pp.87-93
    • /
    • 1995
  • The amount of Cr(Ⅲ) and Cr(Ⅵ) in a chromium plating solution could be determined simultaneously within five minutes using UV/VIS spectrophotometer coupled with a flow-through analysis(FTA) setup. The λmax's at 580 nm and 440 nm which correspond to Cr(Ⅲ) and Cr(Ⅵ), respectively, well obey the Beer-Lambert law in the range over 0.05 g/L for Cr(Ⅲ) and 0.005 g/L for Cr(Ⅵ). when the pH of the sample is less than 4.0, the absorption extinction coefficients of those peaks are not much dependent on the proton concentration. The amount of Cr(Ⅲ) and Cr(Ⅵ), and the total chromium in post treatment chromium plating solution, which normally has few g/L of Cr concentration, could be easily measured using UV/VIS spectrophotometry after the sample had been diluted with sulfuric acid of pH=1.0 in the flow-through analysis setup; this method is far more convenient and faster than the common redox titration (which requires at least 40 min/sample) method, while the accuracy of the method is highly comparable to conventional titrimetric method. Since the implementation of an PTA-UV/VIS setup in any plating industry is cost effective and easy to operate, the analytic method described in this paper may be applied directly for in situ analysis of plating solutions.

  • PDF

Simultaneous Flotation and Determination of Trace Cobalt, Copper and Total Chromium in Sea water by $La(OH)_3$ Coprecipitation ($La(OH)_3$ 공침에 의한 해수중 흔적량 코발트, 구리, 및 전체 크롬의 동시 부선 및 정량)

  • Jo, Man Sik;Im, Heung Bin;Kim, Yeong Sang
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.9
    • /
    • pp.667-675
    • /
    • 1994
  • The precipitate flotation using $La(OH)_3$ as a coprecipitant was studied for the simultaneous determination of trace three elements in a sea water. Several experimental conditions such as pH, coprecipitant and surfactant were investigated with an artificial sea water. To remove the influence of Cr(VI) the Cr(VI) was reduced to Cr(III) using $NaBH_4$ prior to the flotation. Trace amounts of Cu(II), Co(II) and total Cr in 1.0 l sea water was coprecipitated together with the precipitation of $La(OH)_3$ in the solution of pH 9.8 adjusted with 3.OM NaOH solution. The precipitate was floated by using a mixed surfactant (1 to 8 of each 0.5% ethanolic sodium oleate and sodium dodecylsulfate solution) by bubbling a nitrogen gas. The floats was separated and filtrated from the mother liquor by suction. The precipitate was dissolved in 7.0 M $HNO_3$ solution and then marked to 25.0 ml with a deionized water. These elements were determined by graphite fumace atomic absorption spectrophotometry. This method was applied to determine the elements in the sea water of the Eastern and Western coasts. And the recoveries were over 90.0% in the samples into which given amounts of the analyte elements were spiked.

  • PDF

A Study of Hexavalent Chromium Reduction by Iron Sulfide (황화철에 의한 6가 크롬의 환원에 관한 연구)

  • Jo, Se-I;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.657-662
    • /
    • 2005
  • Iron sulfide(FeS) is significantly produced through both abiotic and biotic processes in natural sediments and pore waters. In this study, chromium(VI) reaction with iron sulfide at various initial concentrations and at pH values of 4 and 8 was conducted to better understand the interactions between Cr(VI) and Fe(II) species dissolved from iron sulfide in both the aqueous and solid phases. Also, the removal efficiency of iron sulfide was compared with zero valent iron and other iron bearing oxides such as ${\alpha}-Fe_2O_3$, ${\alpha}-FeOOH$ and $Fe_3O_4$. The Cr(VI) removal rate by iron sulfide was higher at pH 4 than at pH 8 because more dissolved Fe(II) existed at pH 4 than at pH 8. Chromium and iron(oxyhydroxide) could be identified on the iron sulfide surface with transmission microscopy imaging and energy dispersive spectroscopy. The removal capacity of iron sulfide was much higher than zero valent iron and other iron oxide minerals due to the synergic effect of hydrogen sulfide and ferrous iron.

Removal of Nitrate by Ferrous Cement Hydrates (2가철 시멘트 수화물에 의한 질산성 질소의 제거)

  • Kang, Wan-Hyup;Park, Tae-Sook;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.53-60
    • /
    • 2005
  • Ferrous cement hydrates made from hydrating Portland cement doped with Fe (II) were reported to reductively dechlorinate chlorinated organics and to reduce Cr (VI) to Cr (III). In this study, kinetics of nitrate removal by ferrous cement hydrates were investigated. Nitrate removal kinetics were characterized by experimental variables such as cement hydration, amount of cement addition, Fe (II) dose, pH, and byproducts. As a result, hydrated cement showed better performances than non-hydrated cement due to the formation of LDH (layered double hydroxide). Doping of Fe (II) into the cement was found to improve removal efficiency at high pHs by association with Fe (II) sorbed on cement hydrates as a reactive reductant. Reduction of nitrate produced ammonium as a major product, which accounted for 63.5% of the final products, and nitrite (0.15%) as a minor product. These results indicate that the developed media are effective as sorbent/reducing agents in the nitrate removal and the reaction mechanisms of nitrate removal are sorption and reduction.

Photocatalytic activity under visible-light with metal or $WO_3$ deposited-$TiO_2$ tubes (가시광감응을 위한 금속이나 $WO_3$ 도핑된 $TiO_2$ 튜브의 광활성 연구)

  • Heo, Ahyoung;Lee, Changha;Park, Minsung;Shim, Eunjung;Yoon, Jaekyung;Joo, Hyunku
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.227.1-227.1
    • /
    • 2010
  • 본 연구는 자외선 영역의 흡수로 전자 정공의 전하쌍을 생성함으로써 광전압 및 전류를 일으키는 티타니아 물질을 금속지지체 표면에 양극산화로 튜브형 $TiO_2$(anodized tubular $TiO_2$; ATT)로 제조한 후 나노크기의 금속 혹은 $WO_3$입자를 담지하여 광감응 재료로 활용하였다. 이는 기존의 입자나 콜로이드 형태로 광촉매 물질을 고정화하여 사용한 재료의 탈리현상 및 효율저하를 극복하기 위함이다. ATT는 전해질 내에 전기화학적 에칭율과 화학적 용해율의 비율에 의해 나노튜브 길이 성장에 영향을 미치는데 이를 유기 전해질과 불산 전해질을 사용하여 정전압 혹은 정전류의 조건에서 다양한 길이의 $TiO_2$ 나노튜브를 제조하였다. 여기에 전기분해담지(electrolytic deposition; ELD)를 통하여 정전류 조건에서 다양한 금속(Pt, Pd, Ru)을 나노크기의 형태로 담지하여 광촉매 내 생성된 전자 정공의 재결합을 줄이고자 하였고 $WO_3$의 담지를 통하여 가시광 감응을 높이고자 하였다. 제조된 여러 조건의 시료는 SEM과 EDAX를 통하여 형태와 길이, 담지량을 확인 하고 XRD를 이용하여 열처리 온도에 따른 결정화상태를 확인하였으며 광전류 측정 및 Cr(VI)의 광환원과 MB의 광분해를 통하여 광효율을 관찰하였다. 금속이 도핑되었을 경우 순수 ATT보다 보통 3배의 흡착률과 UV광원 아래 2배의 광효율을 관찰할 수 있었는데 이 중 Pt의 담지가 가장 효율이 좋았으며 흡착률에서는 담지량의 증가에 따른 증가선을 관찰 할 수 있었으나 광원 사용시 3%담지율에서 최적을 확인 할 수 있었다. 또한 $TiO_2$외 가시광감응 활성을 높이기 위한 다양한 광촉매제조가 진행 중에 있다.