• Title/Summary/Keyword: Cover test

Search Result 799, Processing Time 0.024 seconds

Design and Implementation of the SSL Component based on CBD (CBD에 기반한 SSL 컴포넌트의 설계 및 구현)

  • Cho Eun-Ae;Moon Chang-Joo;Baik Doo-Kwon
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.12 no.3
    • /
    • pp.192-207
    • /
    • 2006
  • Today, the SSL protocol has been used as core part in various computing environments or security systems. But, the SSL protocol has several problems, because of the rigidity on operating. First, SSL protocol brings considerable burden to the CPU utilization so that performance of the security service in encryption transaction is lowered because it encrypts all data which is transferred between a server and a client. Second, SSL protocol can be vulnerable for cryptanalysis due to the key in fixed algorithm being used. Third, it is difficult to add and use another new cryptography algorithms. Finally. it is difficult for developers to learn use cryptography API(Application Program Interface) for the SSL protocol. Hence, we need to cover these problems, and, at the same time, we need the secure and comfortable method to operate the SSL protocol and to handle the efficient data. In this paper, we propose the SSL component which is designed and implemented using CBD(Component Based Development) concept to satisfy these requirements. The SSL component provides not only data encryption services like the SSL protocol but also convenient APIs for the developer unfamiliar with security. Further, the SSL component can improve the productivity and give reduce development cost. Because the SSL component can be reused. Also, in case of that new algorithms are added or algorithms are changed, it Is compatible and easy to interlock. SSL Component works the SSL protocol service in application layer. First of all, we take out the requirements, and then, we design and implement the SSL Component, confidentiality and integrity component, which support the SSL component, dependently. These all mentioned components are implemented by EJB, it can provide the efficient data handling when data is encrypted/decrypted by choosing the data. Also, it improves the usability by choosing data and mechanism as user intend. In conclusion, as we test and evaluate these component, SSL component is more usable and efficient than existing SSL protocol, because the increase rate of processing time for SSL component is lower that SSL protocol's.

Long-term Oxygen Therapy for Chronic Respiratory Insufficiency: the Situation in Korea after the Health Insurance Coverage: a Multi-center Korean Survey -Study for the Development and Dissemination of the COPD Guidelines, Clinical Research Center for Chronic Obstructive Airway Disease- (가정산소치료의 보험급여 실시 이후 처방 실태: 다기관 조사 -만성기도폐쇄성질환 임상연구센터 제3세부과제 만성기도폐쇄성질환 진료지침 개발/보급 연구-)

  • Park, Myung Jae;Yoo, Jee-Hong;Choi, Cheon Woong;Kim, Young Kyoon;Yoon, Hyoung-Kyu;Kang, Kyung Ho;Lee, Sung Yong;Choi, Hye Sook;Lee, Kwan Ho;Lee, Jin Hwa;Lim, Sung-Chul;Kim, Yu-Il;Shin, Dong Ho;Kim, Tae Hyun;Jung, Ki-Suck;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.2
    • /
    • pp.88-94
    • /
    • 2009
  • Background: From November 2006, The national health insurance system in the Republic of Korea began to cover prescribed long-term oxygen therapy (LTOT) in patients with chronic respiratory insufficiency. This study examined the current status of LTOT after national health insurance coverage. Methods: Between November 1, 2006 and June 30, 2008, the medical records of patients who were prescribed LTOT by chest physicians were reviewed. The data was collected from 13 university hospitals. Results: 197 patients (131 male and 66 female) were prescribed LTOT. The mean age was 64.3${\pm}$13.0 years. The most common underlying disease was chronic obstructive pulmonary disease (n=103, 52.3%). Chest physicians prescribed LTOT using arterial blood gas analysis or a pulse oxymeter (74.6%), symptoms (14%), or a pulmonary function test (11.2%). The mean oxygen flow rate was 1.56${\pm}$0.68 L/min at rest, 2.08${\pm}$0.91 L/min during exercise or 1.51${\pm}$0.75 L/min during sleep. Most patients (98.3%) used oxygen concentrators. Only 19% of patients used ambulatory oxygen supplies. The oxygen saturation before and after LTOT was 83.18${\pm}$10.48% and 91.64${\pm}$7.1%, respectively. After LTOT, dyspnea improved in 81.2% of patients. The mean duration of LTOT was 16.85${\pm}$6.71 hours/day. The rental cost for the oxygen concentrator and related electricity charges were 48,414${\pm}$15,618 won/month and 40,352${\pm}$36,815 won/month, respectively. Approximately 75% of patients had a regular visit by the company. 5.8% of patients had personal pulse oxymetry. 54.9% of patients had their oxygen saturation checked on each visit hospital. 8% of patients were current smokers. The most common complaint with LTOT was the limitation of daily activity (53%). The most common complaint with oxygen concentrators was noise (41%). Conclusion: The patients showed good compliance with LTOT. However, only a few patients used an ambulatory oxygen device or had their oxygen saturation measured.

Evaluation of Field Applicability with Coal Mine Drainage Sludge as a Liner: Part II: Effect of Freezing/Thawing in CMDS Mixed Liner (차수재로의 광산슬러지 재활용 적용성 평가: Part II: 동결/융해에 의한 광산슬러지 혼합 차수재의 거동)

  • Lee, Jai-Young;Bae, Sun-Young;Park, Kyoung-Joo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.73-79
    • /
    • 2011
  • Based on the results of Part 1 of our two-parts paper, the possibility on field applicability of CMDS(Coal Mine Drainage Sludge) mixed with bentonite and cement as a liner in landfill sites was investigated. The optimum moisture content that met the landfill liner condition was obtained when the ratio of CMDS: bentonite: cement was 1: 0.5: 0.3 in a lab-scale. The relative compaction was measured in 90.1%, which results for construction field have been generally acceptable. In this study, a large-scale Lysimeter($1.0m{\times}1.5m{\times}2.0m$) was used to simulate the effects of the layer on the freeze/thaw by -20 average temperature. The mixture after freezing/thawing showed compressive strength more than $5kg/cm^2$, which was satisfied with EPA standards. Initial permeability of CMDS was $7.10{\times}10^{-7}cm/s$ and permeability its mixture after freezing/thawing was increased to $9.80{\times}10^{-7}cm/s$. The change of temperature in the layers rises and falls with linear and temperature gradient keep maintain the present state. Moisture contents in the layers have not been radically changed. Through the leaching test determined by KSLT method, it was found that heavy metals excluding Zn and Ni were not leached out or leached out less than the standards during 7 cycles of freezing/thawing process. Since it shows the increased permeability about 1.5 times and slight change in moisture content, but it was satisfied with EPA standar through 7 cycles of freezing/thawing process, this mixture can be applied as a liner in landfill final cover system.

Development of Solar Warehouse for Drying and Storing the Agricultural Products (농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seob;Kim, Soung Rai;Jeon, Byeong Seon
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.357-370
    • /
    • 1982
  • Recent concern regarding price and availability of fossil fuels has spurred the interest in alternative sources for farm crop drying. Among the available options such as biomass energy, wind power, nuclear energy and solar energy etc., the increasing attention is being directed to the utilization of heat from solar energy especially for farm crop drying. Even though solar energy is dispersed over a large land area and only a relatively small amount of energy can be simply collected, the advantages of solar energy is that the energy is free, non-polluting. The study reported here was designed to help supply the informations for the development of simple and relatively inexpensive solar warehouse for farm crop drying and storage. Specifically, the objectives of this study were to determine the performance of the solar collector fabricated, to compare solar supplemented heat drying with natural air drying and to develop a simulation model of temperature in stored grain, which can be used to study the effects due to changes in ambient air temperature. For those above objectives, solar collector was fabricated from available materials. Corrugated steel galvanized sheet, painted flat black, was used as absorbers and clear 0.2mm polyethylene sheet was the cover material. The warehouse for rough rice drying and storage was constructed with concrete block, and the solar collector was used as the roof of warehouse instead of original roofing system of it. The results obtained in this study were as follows: 1. The thermal efficiency of the solar collector was average 26 percent and the overall heat transfer coefficient of the collector was approximately $25kJ/hr.m^2\;^{\circ}K$. 2. Solar heated air was sufficient to dry one cubic meter of rough rice from 23.5 to 15.0 percent in 7 days and natural air was able to dry the same amount of rough rice from 20.0 to 5 percent in l2 days. 3. Drying with solar heat reduced the required drying time to dry the same amount of rough rice into a half compared to natural air drying, but overdrying problems of the bottom layer were so severe that these problems should be thoroughly analyzed. 4. Simulation model of temperature in stored grain was developed and the results of predicted temperature agreed well with test results. 5. Based on those simulated temperature, changes in the grain-temperature were a large at the points of the wallside and the damage of the grain would be severe at the contact area of wall.

  • PDF

Does Home Oxygen Therapy Slow Down the Progression of Chronic Obstructive Pulmonary Diseases?

  • Han, Kyu-Tae;Kim, Sun Jung;Park, Eun-Cheol;Yoo, Ki-Bong;Kwon, Jeoung A;Kim, Tae Hyun
    • Journal of Hospice and Palliative Care
    • /
    • v.18 no.2
    • /
    • pp.128-135
    • /
    • 2015
  • Purpose: As the National Health Insurance Service (NHIS) began to cover home oxygen therapy (HOT) services from 2006, it is expected that the new services have contributed to overall positive outcome of patients with chronic obstructive pulmonary disease (COPD). We examined whether the usage of HOT has helped slow down the progression of COPD. Methods: We examined hospital claim data (N=10,798) of COPD inpatients who were treated in 2007~2012. We performed ${\chi}^2$ tests to analyze the differences in the changes to respiratory impairment grades. Multiple logistic regression analysis was used to identify factors that are associated with the use of HOT. Finally, a generalized linear mixed model was used to examine association between the HOT treatment and changes to respiratory impairment grades. Results: A total of 2,490 patients had grade 1 respiratory impairment, and patients with grades 2 or 3 totaled 8,308. The OR for use of HOT was lower in grade 3 patients than others (OR: 0.33, 95% CI: 0.30~0.37). The maintenance/mitigation in all grades, those who used HOT had a higher OR than non-users (OR: 1.41, 95% CI: 1.23~1.61). Conclusion: HOT was effective in maintaining or mitigating the respiratory impairment in COPD patients.

Yield Increase and Energy Saving Effect on Plastic Greenhouse Covered with Polyolefin Film (PO필름 피복 온실의 수량 증대 및 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kim, Jin Gu;Lee, Jae Han;Kang, Youn Koo;Lim, Mi Young;Kim, Hye Min
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.428-439
    • /
    • 2020
  • This study was carried out to investigate the effect of PO film on the increase of crop yield and energy saving through PO and PE film greenhouse application and comparison test. As a experimental greenhouse, two single span greenhouses (1-1 W) and two double span greenhouses (1-2 W) were used. During winter season, PO film (0.15 mm outer layer, 0.10mm inner layer) was used as a covering material of greenhouse in double layers for double-span (B15) and single-span(B21), and PE film used for double-span (B15), and single-span (B23) as a control. The experimental vegetable was tomato(Solanum lycopersicum L.) cultivated in soil and the cultivar of that was 'Happiness'. That was cultivated from December 3, 2019 to April 30, 2020. The temperature at night inside the greenhouse was maintained at 15℃, and the side and roof windows were opened to maintain 23 ~ 24℃ during the day. As a result, this study showed that the yield in single-span greenhouse(B21) covered with a PO film increased 20% and that in double-span greenhouse (B16) increased by 9% compared to the greenhouse covered with a PE film (B23, B15). Fuel consumption of the single-span greenhouse (B21) with the cover of PO film was reduced by 12.4% and that of double-span greenhouse was done by 11.5% compared to that of the PE film greenhouse (B23, B15) without any difference between them in growing state.

A Comparative Study on the Possibility of Land Cover Classification of the Mosaic Images on the Korean Peninsula (한반도 모자이크 영상의 토지피복분류 활용 가능성 탐색을 위한 비교 연구)

  • Moon, Jiyoon;Lee, Kwang Jae
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_4
    • /
    • pp.1319-1326
    • /
    • 2019
  • The KARI(Korea Aerospace Research Institute) operates the government satellite information application consultation to cope with ever-increasing demand for satellite images in the public sector, and carries out various support projects including the generation and provision of mosaic images on the Korean Peninsula every year to enhance user convenience and promote the use of satellite images. In particular, the government has wanted to increase the utilization of mosaic images on the Korean Peninsula and seek to classify and update mosaic images so that users can use them in their businesses easily. However, it is necessary to test and verify whether the classification results of the mosaic images can be utilized in the field since the original spectral information is distorted during pan-sharpening and color balancing, and there is a limitation that only R, G, and B bands are provided. Therefore, in this study, the reliability of the classification result of the mosaic image was compared to the result of KOMPSAT-3 image. The study found that the accuracy of the classification result of KOMPSAT-3 image was between 81~86% (overall accuracy is about 85%), while the accuracy of the classification result of mosaic image was between 69~72% (overall accuracy is about 72%). This phenomenon is interpreted not only because of the distortion of the original spectral information through pan-sharpening and mosaic processes, but also because NDVI and NDWI information were extracted from KOMPSAT-3 image rather than from the mosaic image, as only three color bands(R, G, B) were provided. Although it is deemed inadequate to distribute classification results extracted from mosaic images at present, it is believed that it will be necessary to explore ways to minimize the distortion of spectral information when making mosaic images and to develop classification techniques suitable for mosaic images as well as the provision of NIR band information. In addition, it is expected that the utilization of images with limited spectral information could be increased in the future if related research continues, such as the comparative analysis of classification results by geomorphological characteristics and the development of machine learning methods for image classification by objects of interest.

The Comparison of Noise-induced Hearing Loss Evaluation Criteria for Management (소음성난청 관리를 위한 판정기준간의 비교)

  • 남궁원자;원정일
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.123-134
    • /
    • 1998
  • The study was performed to investigate the differences among various evaluation criteria for noise-induced hearing loss(NIHL). The subjects were 100 workers who had received detailed audiometric examinations after the periodic annual examination for hearing loss. The evaluation criteria included were as follows: The criterion I was NIHL of 50dB or greater at 4,000Hz in either ear which is one of the legal requirements for determining occupational hearing loss in Korea. The criterion II was NIHL of 40dB or greater by 4-divided classification(a+b+c+d/4 at 500Hz(a), 1,000Hz(b), 2,000Hz(c), 4,000Hz(d)) which is also one of the legal requirements for determining occupational hearing loss in Korea. The criterion III was NIHL of 31dB of greater by 6-divided classification(a+2b+2c+d/6) which is the workers' compensation standard. The criterion IV was NIHL of 40dB or greater by 6-divided classification(a+2b+2c+d/6), the criterion used to prohibite workers to be employed in the noisy workplace. The criterion V was NIHL of 40dB or greater by 3-divided classification(a+b+c/3) which is the guideline of the Japanes Labour Department. The results were as follows; 1. The percentage of workers with NIHL by the criterion I was the highest(96%) and covered all workers with NIHL diagnosed by other criteria. Therefore, this criterion was the most sensitive one for early detection of NIHL among various evaluation criteria. 2. The percentage of workers with NIHL by the criterion II was 29% of the subjects, but all of them could be diagnosed as having NIHL by the criterion I and 33.1% of the NIHL by the criterion III could not be covered by the criterion II. Thus, this criterion was not considered suitable as an initial step for determining occupational hearing loss. 3. The percentage of workers with NIHL by the criterion III was 45% of the subjects. This percentage was 46.9% of the NIHL by the criterion I and was estimated to cover 3.6% of all noise exposed workers. 4. The percentage of workers with NIHL by the criterion IV was 28% of the subjects, but 37.8% of the NIHL by the criterion III and 70.8% of the NIHL by the criterion I were not covered by the criterion. Therefore, these workers could have been employed in the noisy workplaces. 5. Employed relocation which was one of the post management methods was an option in the criterion I in Korea and in the criterion V in Japan. The number of NIHL by the criterion I was 6.7times greater than that by the criterion V. Thus, although employee relocation was not used exclusively, many more workers with NIHL could have been relocated. In conclusion, this study revealed that the criteria being used for managing occupational hearing loss showed a lack uniformity among them. In addition, since these criteria are all relied on the total threshold shifts caused by the noise exposure at the time of hearing test with no consideration given to the past noise exposure history nor age, it can be said that they are not an effective tool for occupational hearing loss management. Since legal requirements are usually followed after being diagnosed as having NIHL, it is recommended that a uniform diagnostic criterion should be used to minimize confusion. Pre-employment hearing tests should also be utilized so as to managing occupational hearing loss after employment rather than being used as a legal roadblock of prohibiting workers with mild hearing loss from being employed. Thus, what is needed is an establishment of a rational criterion for occupational hearing loss management rather than for legal requirements.

  • PDF

Generation of Sea Surface Temperature Products Considering Cloud Effects Using NOAA/AVHRR Data in the TeraScan System: Case Study for May Data (TeraScan시스템에서 NOAA/AVHRR 해수면온도 산출시 구름 영향에 따른 신뢰도 부여 기법: 5월 자료 적용)

  • Yang, Sung-Soo;Yang, Chan-Su;Park, Kwang-Soon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.165-173
    • /
    • 2010
  • A cloud detection method is introduced to improve the reliability of NOAA/AVHRR Sea Surface Temperature (SST) data processed during the daytime and nighttime in the TeraScan System. In daytime, the channels 2 and 4 are used to detect a cloud using the three tests, which are spatial uniformity tests of brightness temperature (infrared channel 4) and channel 2 albedo, and reflectivity threshold test for visible channel 2. Meanwhile, the nighttime cloud detection tests are performed by using the channels 3 and 4, because the channel 2 data are not available in nighttime. This process include the dual channel brightness temperature difference (ch3 - ch4) and infrared channel brightness temperature threshold tests. For a comparison of daytime and nighttime SST images, two data used here are obtained at 0:28 (UTC) and 21:00 (UTC) on May 13, 2009. 6 parameters was tested to understand the factors that affect a cloud masking in and around Korean Peninsula. In daytime, the thresholds for ch2_max cover a range 3 through 8, and ch4_delta and ch2_delta are fixed on 5 and 2, respectively. In nighttime, the threshold range of ch3_minus_ch4 is from -1 to 0, and ch4_delta and min_ch4_temp have the fixed thresholds with 3.5 and 0, respectively. It is acceptable that the resulted images represent a reliability of SST according to the change of cloud masking area by each level. In the future, the accuracy of SST will be verified, and an assimilation method for SST data should be tested for a reliability improvement considering an atmospheric characteristic of research area around Korean Peninsula.

Effect of Visual Sensory Improvement by Amblyopia Treatment on Improvement of Ocular Functions (약시 치료에 의한 시감각 개선이 안기능 향상에 미치는 효과)

  • Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.551-555
    • /
    • 2014
  • Purpose: This study is to investigate if the improvement of visual sensory (VS) by amblyopia treatment affects the ocular functions in refractive errors, accommodative errors and phoria at distance and near. Methods: 10 subjects (17 eyes, mean age of $10.7{\pm}2.9$ years) who treated amblyopia completely, were participated for this study. Refractive errors, accommodative errors, and distance and near phoria were compared between before and after treatments of amblyopia. Refractive errors and accommodative errors at 40 cm were measured using openfield auto-refractor (NVision-5001, Shin Nippon, Japan) and using monocular estimated method (MEM) respectively. Phoria was determined at 3 m for distance and at 40 cm for near using Howell phoria card, cover test or Maddox rod. Results: Mean corrected visual acuity (CVA) significantly increased from $0.46{\pm}0.11$ (decimal notation) for before amblyopia treatment to a level of $1.03{\pm}0.13$ for after amblyopia treatment (p < 0.001). For spherical refractive error, hyperopia significantly decreased from $+2.29{\pm}0.86D$ to a level of $+1.1{\pm}2.38D$ (p < 0.05) but astigmatism did not significantly change; $-1.80{\pm}1.41D$ for before treatment and $-1.65{\pm}1.30D$D for after treatment (p > 0.05). Accommodative error significantly decreased from accommodative lag of $+1.1{\pm}0.75D$ to a level of $+0.5{\pm}0.59D$ (accommodative lag) (p < 0.05). Distance phoria significantly changed from eso $2.9{\pm}6.17PD$ (prism diopters) to a level of eso $0.2{\pm}3.49PD$ (p < 0.05), and near phoria also significantly changed from eso $0.4{\pm}2.32PD$ to level of exo $2{\pm}4.9PD$ (p < 0.05). There was a high correlation (r = 0.88, p < 0.001) between improvement of visual acuity and decrease of accommodative lag. Conclusions: Hyperopic refractive error decreased with improvement of CVA or VS by amblyopia treatment. And the improvement of VS by amblyopia treatment also improved accommodative error, and changed phoria coupled with accommodation.