• 제목/요약/키워드: Coupling Scheme

검색결과 289건 처리시간 0.023초

Droop Control Scheme of a Three-phase Inverter for Grid Voltage Unbalance Compensation

  • Liu, Hongpeng;Zhou, Jiajie;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1245-1254
    • /
    • 2018
  • The stability of a grid-connected system (GCS) has become a critical issue with the increasing utilization of renewable energy sources. Under grid faults, however, a grid-connected inverter cannot work efficiently by using only the traditional droop control. In addition, the unbalance factor of voltage/current at the common coupling point (PCC) may increase significantly. To ensure the stable operation of a GCS under grid faults, the capability to compensate for grid imbalance should be integrated. To solve the aforementioned problem, an improved voltage-type grid-connected control strategy is proposed in this study. A negative sequence conductance compensation loop based on a positive sequence power droop control is added to maintain PCC voltage balance and reduce grid current imbalance, thereby meeting PCC power quality requirements. Moreover, a stable analysis is presented based on the small signal model. Simulation and experimental results verify the aforementioned expectations, and consequently, the effectiveness of the proposed control scheme.

리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘 (A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser)

  • 김슬기;김응상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.

유동가속부식이 잠재한 곡관내의 3차원 난류유동 해석 (Three-dimensional Turbulent Flow Analysis in Curved Piping Systems Susceptible to Flow-Accelerated Corrosion)

  • 조종철;김윤일;최석기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.900-907
    • /
    • 2000
  • The three-dimensional turbulent flow in curved pipes susceptible to flow-accelerated corrosion has been analyzed numerically to predict the pressure and shear stress distributions on the inner surface of the pipes. The analysis employs the body-fitted non-orthogonal curvilinear coordinate system and a standard $ {\kappa}-{\varepsilon}$ turbulence model with wall function method. The finite volume method is used to discretize the governing equations. The convection term is approximated by a high-resolution and bounded discretization scheme. The cell-centered, non-staggered grid arrangement is adopted and the resulting checkerboard pressure oscillation is prevented by the application of a modified version of momentum interpolation scheme. The SIMPLE algorithm is employed for the pressure and velocity coupling. The numerical calculations have been performed for two curved pipes with different bend angles and curvature radii, and discussions have been made on the distributions of the primary and secondary flow velocities, pressure and shear stress on the inner surface of the pipe to examine applicability of the present analysis method. As the result it is seen that the method is effective to predict the susceptible systems or their local areas where the fluid velocity or local turbulence is so high that the structural integrity can be threatened by wall thinning degradation due to flow-accelerated corrosion.

  • PDF

자기매계변수 연성을 갖는 응답의 통계적 특성 (Stochastic Response of a System with Autoparametric Coupling)

  • 조덕상;김영종
    • 한국전산구조공학회논문집
    • /
    • 제13권4호
    • /
    • pp.387-394
    • /
    • 2000
  • 본 연구에서는 광대역 불규칙가진력을 받는 자기매계변수계의 모드상호작용을 고찰하였다. 고찰대상 모델은 매우 흔한 추조물의 형태인 내부공진을 갖는 자기매계변수 동흡진기이다. Gaussian closure 방법에 의하여 계의 불규칙 응답을 나타내는 통적 모멘트방정식은 1차 및 2차 모멘트로 구성된 자율 상미분방적식으로 줄여진다. 계의 평형해와 평형해의 안정성측면에서 계의 응답이 조사되었다. 참고문헌 [18]과 [20]에서 보고된 발견한 감쇠가 안정성을 축소하기도 한다라는 이 효과는 본 연구에서 발견할 수 없었다. 또한 확정적 비선형계에 존재하는 포화현상은 발견되지 않았다.

  • PDF

APPLICATION OF BACKWARD DIFFERENTIATION FORMULA TO SPATIAL REACTOR KINETICS CALCULATION WITH ADAPTIVE TIME STEP CONTROL

  • Shim, Cheon-Bo;Jung, Yeon-Sang;Yoon, Joo-Il;Joo, Han-Gyu
    • Nuclear Engineering and Technology
    • /
    • 제43권6호
    • /
    • pp.531-546
    • /
    • 2011
  • The backward differentiation formula (BDF) method is applied to a three-dimensional reactor kinetics calculation for efficient yet accurate transient analysis with adaptive time step control. The coarse mesh finite difference (CMFD) formulation is used for an efficient implementation of the BDF method that does not require excessive memory to store old information from previous time steps. An iterative scheme to update the nodal coupling coefficients through higher order local nodal solutions is established in order to make it possible to store only node average fluxes of the previous five time points. An adaptive time step control method is derived using two order solutions, the fifth and the fourth order BDF solutions, which provide an estimate of the solution error at the current time point. The performance of the BDF- and CMFD-based spatial kinetics calculation and the adaptive time step control scheme is examined with the NEACRP control rod ejection and rod withdrawal benchmark problems. The accuracy is first assessed by comparing the BDF-based results with those of the Crank-Nicholson method with an exponential transform. The effectiveness of the adaptive time step control is then assessed in terms of the possible computing time reduction in producing sufficiently accurate solutions that meet the desired solution fidelity.

Numerical Study on Performance of Horizontal Axis (Propeller) Tidal Turbine

  • Kim, Kyuhan;Cahyono, Joni
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.296-296
    • /
    • 2015
  • The aim of this paper is to numerically explore the feasibility of designing a Mini-Hydro turbine. The interest for this kind of horizontal axis turbine relies on its versatility. For instance, in the field of renewable energy, this kind of turbine may be considered for different applications, such as: tidal power, run-of-the-river hydroelectricity, wave energy conversion. It is fundamental to improve the turbine performance and to decrease the equipment costs for achievement of "environmental friendly" solutions and maximization of the "cost-advantage". In the present work, the commercial CFD code ANSYS is used to perform 3D simulations, solving the incompressible Unsteady Reynolds-Averaged Navier-Stokes (U-RANS) equations discretized by means of a finite volume approach. The implicit segregated version of the solver is employed. The pressure-velocity coupling is achieved by means of the SIMPLE algorithm. The convective terms are discretized using a second order accurate upwind scheme, and pressure and viscous terms are discretized by a second-order-accurate centered scheme. A second order implicit time formulation is also used. Turbulence closure is provided by the realizable k - turbulence model. In this study, a mini hydro turbine (3kW) has been considered for utilization of horizontal axis impeller. The turbine performance and flow behavior have been evaluated by means of numerical simulations. Moreover, the performance of the impeller varied in the pressure distribution, torque, rotational speed and power generated by the different number of blades and angles. The model has been validated, comparing numerical results with available experimental data.

  • PDF

Hygrothermal sound radiation analysis of layered composite plate using HFEM-IBEM micromechanical model and experimental validation

  • Binita Dash;Trupti R Mahapatra;Punyapriya Mishra;Debadutta Mishra
    • Structural Engineering and Mechanics
    • /
    • 제89권3호
    • /
    • pp.265-281
    • /
    • 2024
  • The sound radiation responses of multi-layer composite plates subjected to harmonic mechanical excitation in hygrothermal environment is numerically investigated. A homogenized micromechanical finite element (FE) based on the higher-order mid-plane kinematics replicating quadratic function as well as the through the thickness stretching effect together with the indirect boundary element (IBE) scheme has been first time employed. The isoparametric Lagrangian element (ten degrees of freedom per node) is used for discretization to attain the hygro-thermo-elastic natural frequencies and the modes of the plate via Hamilton's principle. The effective material properties under combined hygrothermal loading are considered via a micromechanical model. An IBE method is then implemented to attain structure-surrounding coupling and the Helmholtz wave equation is solved to compute the sound radiation responses. The effectiveness of the model is tested by converging it with the similar analytical/numerical results as well as the experimentally acquired data. The present scheme is further hold out for solving diverse numerical illustrations. The results revealed the relevance of the current higher-order FE-IBE micromechanical model in realistic estimation of hygro-thermo-acoustic responses. The geometrical parameters, volume fraction of fiber, layup, and support conditions alongside the hygrothermal load is found to have significant influence on the vibroacoustic characteristics.

큐 서비스 방식에서 실시간 트래픽 연결 수락 제어 (Real-Time Traffic Connection Admission Control of Queue Service Discipline)

  • 나하선;나상동
    • 한국통신학회논문지
    • /
    • 제27권5C호
    • /
    • pp.445-453
    • /
    • 2002
  • ATM망에서 큐 서비스 방식에서는 상위 프레임과 하위 프레임을 따로 정의하여 대역폭 할당과 전송 지연보장을 분리할 수 있기 때문에 종단간 전송 한계에서 QoS를 보장할 수 있는 단순화한 큐 서비스 방식을 제안하였다. 제안한 큐 서비스 방식은 실시간 트래픽과 비실시간 트래픽을 나누어 저장하기 때문에 연결별 트래픽 조절기 없이도 지연 지터 특성이 개선된다. 제안된 큐 서비스 방식을 이용하여 연결 수락 제어는 트래픽 왜곡의 영향을 계산 할 수 없는 트래픽 왜곡의 영향이 실제로 존재한다는 가정 하에 트래픽 왜곡에 대한 영향에 종단간 지연을 보장함으로서 연결 수락 가능범위를 다양한 프레임의 길이에 대해 나타내었으며, 프레임의 길이가 클수록 제안된 큐 서비스 방식의 연결 수락 범위가 지연 EDD방식과 비교해서 많은 차이를 보이지만 프레임의 길이를 점차 줄여갈수록 연결 수락 가능 범위가 지연 EDD 방식에 근접함을 나타내었다.

취업률 향상에 기여하는 공학인증 시스템 운영에 관한 연구 (A Study of Operating the Engineering Accreditation System to Contribute to Improving Rate of Employment)

  • 손호재
    • 공학교육연구
    • /
    • 제19권2호
    • /
    • pp.45-52
    • /
    • 2016
  • The employment rate of a college has long been one of the most important elements in college survival strategies. Employment rates may not be key to colleges' survival in other countries, but they are fundamental to colleges in Korea as seen in the Korean government-led National Competency Standard (NCS), which has been underway since its introduction to colleges in Korea. Against this backdrop, if the engineering accreditation system can contribute to improving employment rate in this context, it can take root more quickly. The process conducive to improving employment rates can be classified as both direct and indirect methods. With dwindling school-age population having impacts on colleges and universities, the environment and the education directions of colleges have rapidly been shifting since the introduction of the NCS. Therefore, various survival strategies for colleges need to be developed. An indicator of employment rate of college graduates is among the most important things during this transition process. The Department of Mechanical Engineering at Koje College has consistently shown good records during the past 5 years by matching the accreditation schemes and employment strategies. The department will help put in place the engineering technology education accreditation system at the college through its various innovative and effective programs. To formulate a better employment strategy, it is needed to reflect and consolidate the engineering accreditation scheme into the existing employment policy of college. In short, this paper examines both the engineering accreditation scheme and the employment policy in ways that helps produce a coupling matrix structure. This study looks into the measures for improving employment rates by better adjusting the engineering education methods under the accreditation scheme.

Array Calibration for CDMA Smart Antenna Systems

  • Kyeong, Mun-Geon;Park, Hyung-Geun;Oh, Hyun-Seo;Jung, Jae-Ho
    • ETRI Journal
    • /
    • 제26권6호
    • /
    • pp.605-614
    • /
    • 2004
  • In this paper, we investigate array calibration algorithms to derive a further improved version for correcting antenna array errors and RF transceiver errors in CDMA smart antenna systems. The structure of a multi-channel RF transceiver with a digital calibration apparatus and its calibration techniques are presented, where we propose a new RF receiver calibration scheme to minimize interference of the calibration signal on the user signals. The calibration signal is injected into a multi-channel receiver through a calibration signal injector whose array response vector is controlled in order to have a low correlation with the antenna response vector of the receive signals. We suggest a model-based antenna array calibration to remove the antenna array errors including mutual coupling errors or to predict the element patterns from the array manifold measured at a small number of angles. Computer simulations and experiment results are shown to verify the calibration algorithms.

  • PDF