• Title/Summary/Keyword: Coupling Controller

Search Result 212, Processing Time 0.028 seconds

A Zero Sequence Voltage Injection Method for Cascaded H-bridge D-STATCOM

  • Yarlagadda, Srinivasa Rao;Pathak, Mukesh Kumar
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1088-1096
    • /
    • 2017
  • Load variations on a distribution line result in voltage fluctuations at the point of common coupling (PCC). In order to keep the magnitude of the PCC voltage constant at its rated value and obtain zero voltage regulation (ZVR), a D-STATCOM is installed for voltage correction. Moreover, the ZVR mode of a D-STATCOM can also be used to balance the source current during unbalanced loading. For medium voltage and high power applications, a D-STATCOM is realized by the cascaded H-bridge topology. In the ZVR mode, the D-STATCOM may draw unbalanced current and in this process is required to handle different phase powers leading to deviations in the cluster voltages. Zero sequence voltage needs to be injected for ZVR mode, which creates circulating power among the phases of the D-STATCOM. The computed zero sequence voltage and the individual DC capacitor balancing controller help the DC cluster voltage follow the reference voltage. The effectiveness of the control scheme is verified by modeling the system in MATLAB/SIMULINK. The obtained simulations are further validated by the experimental results using a dSPACE DS1106 and five-level D-STATCOM experimental set up.

Turret location impact on global performance of a thruster-assisted turret-moored FPSO

  • Kim, S.W.;Kim, M.H.;Kang, H.Y.
    • Ocean Systems Engineering
    • /
    • v.6 no.3
    • /
    • pp.265-287
    • /
    • 2016
  • The change of the global performance of a turret-moored FPSO (Floating Production Storage Offloading) with DP (Dynamic Positioning) control is simulated, analyzed, and compared for two different internal turret location cases; bow and midship. Both collinear and non-collinear 100-yr GOM (Gulf of Mexico) storm environments and three cases (mooring-only, with DP position control, with DP position+heading control) are considered. The horizontal trajectory, 6DOF (degree of freedom) motions, fairlead mooring and riser tension, and fuel consumptions are compared. The PID (Proportional-Integral-Derivative) controller based on LQR (linear quadratic regulator) theory and the thrust-allocation algorithm which is based on the penalty optimization theory are implemented in the fully-coupled time-domain hull-mooring-riser-DP simulation program. Both in collinear and non-collinear 100-yr WWC (wind-wave-current) environments, the advantage of mid-ship turret is demonstrated by the significant reduction in heave at the turret location due to the minimal coupling with pitch mode, which is beneficial to mooring and riser design. However, in the non-collinear WWC environment, the mid-turret case exhibits unfavorable weathervaning characteristics, which can be reduced by employing DP position and heading controls as demonstrated in the present case studies. The present study also reveals the plausible cause of the failure of mid-turret Gryphon Alpha FPSO in milder environment than its survival condition.

Design of 5'' True Color FED Driving System (5'' True Color FED 구동시스템 설계)

  • Shin, Hong-Jae;Kwon, Oh-Kyong;Kwack, Kae-Dal
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.70-78
    • /
    • 2001
  • We have developed a novel driving system of 5' true color FED using voltage controlled PWM method which has current control effect. The proposed method has the advantage of voltage controlled pulse width modulation method and current control method. Also, we propose a new circuit model of FED subpixel for circuit simulation of FED driving circuits, considering some parasitic effects, i.e., cross talk, line coupling effect and leakage current to the adjacent cathode lines. Output stage of the data driving circuit is optimized using the proposed circuit model. In video data processing, FED controller uses the parallel processing of R.G.B input data, so duty ratio is maximized and brightness of FED increases. With this results, no noise and high quality performance is achieved in display of 5' true color FED.

  • PDF

A Study on Parallel Operation of PWM Converter for Auxiliary Power Supply of High Speed Train (고속전철 보조전원장치용 PWM 컨버터의 병렬운전에 관한 연구)

  • Kim, Yeon-Chung;O, Geun-U;Won, Chung-Yeon;Choe, Jong-Muk;Gi, Sang-U
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.6
    • /
    • pp.64-72
    • /
    • 2000
  • This paper deals with the parallel operation of two PWM converters for auxiliary block of high speed train. The parallel operation of AC/DC PWM converter controlled by 3-level PWM switching method to operate switching devices to realize a high power factor and reduce the primary side of the transformer current harmonics is proposed. In this paper, it is presented the phase shift technique between two converters switching phase, solution to eliminate the coupling effects due to the transformer and zero crossing detection method for synchronized with the source and controller. Experimental results for laboratory system with TMS320C31 microprocessor and 10[kVA]PWM converter confirm the validity of the proposed algorithm.

  • PDF

Research on Speed Estimation Method of Induction Motor based on Improved Fuzzy Kalman Filtering

  • Chen, Dezhi;Bai, Baodong;Du, Ning;Li, Baopeng;Wang, Jiayin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.272-275
    • /
    • 2014
  • An improved fuzzy Kalman filtering speed estimation scheme was proposed by means of measuring stator side voltage and current value based on vector control state equation of induction motor. The designed fuzzy adaptive controller conducted recursive online correction of measurement noise covariance matrix by monitoring the ratio of theory residuals and actual residuals to make it approach real noise level gradually, allowing the filter to perform optimal estimation to improve estimation accuracy of EKF. Meanwhile, co-simulation scheme based on MATLAB and Ansoft was proposed in order to improve simulation accuracy. Field-circuit coupling problems of induction motor under the action of vector control were solved and the parameter optimization accuracy was improved dramatically. The simulation and experimental results show that this algorithm has a strong ability to inhibit the random measurement noise. It is able to estimate motor speed accurately, and has superior static and dynamic characteristics.

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

강자성체를 이용한 연속 가변 토크 제어 전달 기구의 개발

  • Seo, Hyo-Jeong;An, Jae-Yeong;Myeong, Jin-Sol;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.140-140
    • /
    • 2017
  • 4륜 장착 자동차의 토크 전달은 2륜 구동, 4륜 구동 모드를 간단히 전환하는 방식(part time 4WD)과 항시 사륜 구동 모드에서 전후륜의 토크 전달비를 제어하는 방식(AWD, all wheel drive)이 있다. 경제의 발달에 따라서 취미 인구의 확대로 국내에만 180만 명의 R/C car 사용자가 있다. 이 중 2WD-4WD의 전환을 differential lock mechanism으로 구현한 수입산 모델의 가격이 1,000,000원을 호가하지만 가변 제어 방식이 아닌, 정차 후 2-4륜 구동 전환 방식을 적용하고 있으며 상대적으로 내구성이 떨어진다. DC motor의 출력이 늘어나고 배터리의 성능이 좋아진 현재 소형 RC car의 최고 속도는 80 km/h 정도로 빨라졌다. 그러나 마찰 계수가 낮은 노면(실내의 대부분 평활 처리된 복도)에서는 2륜 구동 모드의 활용도가 매우 낮다. 미끄러운 노면에서 후륜 구동 모드로는 oversteer가 발생하여 차량이 스핀하기 쉽고 전륜 구동 모드로는 understeer가 발생하여 제대로 된 코너링이 어렵다. 상시 4륜 구동 모드는 에너지 소모가 크고 전후륜이 tight coupling되어 있는 문제 때문에 일반적인 노면에서 부드러운 코너링이 잘 이루어지지 않는 문제가 있다. 본 연구에서 제안하는 방식은 그림 1와 같이 center shaft의 중간에 영구 자석으로 만들어진 토크 전달용 판이 있고 그 사이에 자계를 차폐할 수 있는 강자성체 셔터를 서보 기구에 연결하여 서보 회전각에 따라서 구동 쪽의 토크가 피구동축으로 전달되는 양을 연속 가변제어할 수 있다. 토크 전달용 판의 차폐 면적에 따른 토크 전달양을 전/후륜 바퀴의 Static torque를 통해 측정하였으며(그림 2), 공중 상태에서 즉 공기저항만을 고려한 상태에서의 RPM 회전수 차이 측정(그림3)을 통해 구동 쪽의 회전수가 피구동축으로 전달되는 양을 측정하여 연속가변 토크 제어 전달 기구의 성능을 확인하였다. 이 기구는 현재 1차적으로는 remote controller의 ch 3(ON/OFF제어 방식)에 연결하여 특정한 양의 토크를 전륜 쪽으로 보낼 수 있도록 구현이 가능하며, ch 2(PID제어 방식)에 연결하여 연속 가변 조절이 가능하도록 구현이 가능하다. 부가적으로 Arduino board를 내장하여 전후륜의 휠센서에서 입력되는 신호를 감지하여 자동적으로 전후륜에 배분되는 토크를 제어할 수 있도록 설계 중에 있다.

  • PDF

Optimal Design of Magnetically Levitated Flywheel Energy Storage System Based on System Stability Using Rigid-Body Model (강체모델 기반 시스템 안정성을 고려한 자기부상 플라이휠 에너지 저장장치의 최적 설계)

  • Kim, Jung-Wan;Yoo, Seong-Yeol;Bae, Yong-Chae;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.283-289
    • /
    • 2010
  • Owing to the increasing worldwide interest in green technology and renewable energy sources, flywheel energy storage systems (FESSs) are gaining importance as a viable alternative to traditional battery systems. Since the energy storage capacity of an FESS is proportional to the principal mass-moment of inertia and the square of the running speed, a design that maximizes the principal inertia while operatingrunning at the highest possible speed is important. However, the requirements for the stability of the system may impose a constraint on the optimal design. In this paper, an optimal design of an FESS that not only maximizes the energy capacity but also satisfies the requirements for system stability and reduces the sensitivity to external disturbances is proposed. Cross feedback control in combination with a conventional proportional-derivative (PD) controller is essential to reduce the effect of gyroscopic coupling and to increase the stored energy and the specific energy density.

A Semi-Active Control of the Combustion Instability in a Ducted Premixed Flame (덕트 형상 연소기의 연소불안정에 대한 Semi-Active Control)

  • Song, Jae-Cheon;Song, Jin-Kwan;Hwang, Jeong-Jae;Yoon, Young-Bin;Lee, Jong-Guen
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.11
    • /
    • pp.1131-1139
    • /
    • 2009
  • Combustion Instabilities are caused by a coupling between acoustic waves and unsteady heat release. They can be eliminated using passive controller such as a Helmholtz resonator. But, Helmholtz resonator is normally only effective over a narrow frequency range. In this work, Helmholtz resonator is applied for reducing the combustion oscillations and we vary the Helmholtz resonator volume using piston in oder to tune in the wide range of operating conditions. As the result, it is found that the dominant combustion oscillations can be largely reduced by optimizing the size of resonator volume. And, interesting relation for phase difference of dynamic pressure both combustor and the helmholtz resonator are presented in this paper. Also, we investigate semi-active control using Helmholtz equation and phase difference.

Hierarchical Voltage Regulation of a DFIG-based Wind Power Plant Using a Reactive Current Injection Loop with the Maximum Voltage Dip for a Grid Fault (최대 전압 강하에 비례하는 무효전류 공급 루프를 이용한 DFIG 풍력단지의 계층전압제어)

  • Park, Geon;Kim, Jinho;Kang, Yong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1334-1339
    • /
    • 2016
  • In a power grid that has a high wind power penetration, the fast voltage support of a wind power plant (WPP) during the grid fault is required to stabilize the grid voltage. This paper proposes a voltage control scheme of a doubly-fed induction generator (DFIG)-based WPP that can promptly support the voltage of the point of common coupling (PCC) of a WPP during the grid fault. In the proposed scheme, the WPP and DFIG controllers operate in a voltage control mode. The DFIG controller employs two control loops: a maximum voltage dip-dependent reactive current injection loop and a reactive power to voltage loop. The former injects the reactive power in proportion to the maximum voltage dip; the latter injects the reactive power in proportion to the available reactive power capability of a DFIG. The former improves the performance of the conventional voltage control scheme, which uses the latter only, by increasing the reactive power as a function of the maximum voltage dip. The performance of the proposed scheme was investigated for a 100-MW WPP consisting of 20 units of a 5-MW DFIG under various grid fault scenarios using an EMTP-RV simulator. The simulation results indicate that the proposed scheme promptly supports the PCC voltage during the fault under various fault conditions by increasing the reactive current with the maximum voltage dip.