• 제목/요약/키워드: Coupled-Field Analysis

검색결과 528건 처리시간 0.025초

LC-MS/MS를 이용한 농경지 토양 중 항생제 모니터링 (Monitoring of Veterinary Antibiotics in Agricultural Soils using Liquid Chromatography Coupled with Tandem Mass Spectrometry)

  • 이영준;최정희;정형석;이한솔;박병준;김장억;심재한
    • 한국환경농학회지
    • /
    • 제35권3호
    • /
    • pp.166-174
    • /
    • 2016
  • 농경지 토양에서 대상항생제 6종(amoxicillin, ampicillin, chlortetracycline, enrofloxacin, oxytetracycline, tetracycline을 아세트산 함유 아세토니트릴, Na2Cit.5H2O, Na3Cit.2H2O과 Na2-EDTA로 추출 후 C18으로 정제하여 LC-MS/MS로 분석하는 모니터링을 수행하였다. 그 중 2종의 항생제, chlortetracycline과 enrofloxacin이 국내 농경지 토양에서 검출되었다. 제안한 분석법은 토양 중 잔류 항생제 모니터링을 위한 빠르고 간편한 시험법이었고 다양한 활용이 가능할 것으로 보인다.

실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구 (Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method)

  • 예진;정동희;백성옥
    • 한국대기환경학회지
    • /
    • 제30권6호
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

수치해석을 이용한 이어도 종합해양과학기지의 해상풍 관측 오차 연구 (Numerical Study on the Observational Error of Sea-Surface Winds at leodo Ocean Research Station)

  • 임진우;이경록;심재설;김종암
    • 한국해안해양공학회지
    • /
    • 제18권3호
    • /
    • pp.189-197
    • /
    • 2006
  • 수치해석을 통하여 이어도 종합해양과학기지 구조물이 대기 유동에 미치는 영향을 분석하였고, 이 결과를 바탕으로 과학기지에 설치된 풍속센서에서의 측정값 오차를 평가하는 연구를 수행하였다. 과학기지 형상을 3차원으로 모델링하였고 수치해석을 위한 격자를 생성하여, Navier-Stokes 방정식 및 난류모델을 적용하여 수치해석을 수행하였다. 선정된 자유류의 풍속과 풍향 조건에 대하여 과학기지 구조물에 의해 변화된 유동장을 계산하고, 실제 풍속센서가 설치된 위치에서의 풍속/풍향 정보와 자유류를 비교하였다. 이를 통하여 자유류 방향 및 측정 위치에 따른 데이터의 정확도와 신뢰할 수 있는 데이터 범위를 알아보았다. 본 연구 결과로 관측된 해상풍 데이터의 구조물 간섭에 의한 오차 범위를 정량적으로 파악할 수 있었으며, 과학기지가 위치한 지점의 정확한 해상풍 데이터 제공을 위한 기초 자료로 활용될 것으로 기대된다.

만경강 수중에서 신체보초제품(PPCPS)의 잔류 (The Occurrences of Pharmaceutical and Personal Care Products (PPCPs) in Mankyung River, South Korea)

  • 김준우;김종구;장효상;조현서;다카오 유지;아리조노 코지
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.245-254
    • /
    • 2009
  • In recent years, environmental pollution by phannaceuticals and personal care products (PPCPs) in the aquatic environment is of great concern worldwide. Recent studies have been reported to occur in a variety of environmental organisms such as surface, drinking and ground water, soils, sediments and hospitals. The purpose of this study was to evaluate the occurrence and environmental behavior of fourteen human PPCPs in surface waters of Mankyung River in South Korea. We were conducted to field survey for water quality and PPCPs analysis at November, 2006. PPCPs were analyzed by liquid chromatograph coupled with a tandem mass spectrometer (HPLC-MS/MS). The concentration of COD was measured to be 2.37$\sim$19.71 mg/L, which was belong to 4$\sim$5 grade in water quality criteria of lake. Station 2 that there is no pollution in upper stream, was appeared to lower concentration. The concentration of TN and TP, that is cause matter of eutrophication, were found to be 7.78$\sim$35.42 mg/L and 0.08$\sim$0.95 mg/L, respectively, which were exceeding 5 grade in Lake water quality criteria. The 11 kind of PPCPs compounds except levofloxacin and triclosan were detected to Mankyung river. PPCPs concentrations of STP(Sewer Treatment Plant) effluents and aquatic environment in Mankyung river have been detected in the range from dozens of ng/L to hundreds of ${\mu}g/L$ that by order of atenolol, carbamazepine, propranolol, Ibuprofen, erythromycin, ifenprodil, clarithromycin, mefenamic acid, fluconazole, indomethacin, disopyramide. PPCPs concentration of Station 1 and 5, which was influenced by Jeonju STP and Wanju STP, was detected high values. Station 2 that there is no pollution, showed lower values. Station 3 which joined Gosan stream and Jeonju stream and station 4 which influenced by stock wastewater was detected to low values.

$TBP/XAD-16/HNO_3$추출 크로마토그래피에 의한 모의 사용후핵연료 용해용액 중 미량 핵분열생성물 원소의 분리 (Separation of Fission Product Elements from Synthetic Dissolver Solutions of Spent Pressurized Water Reactor Fuels by $TBP/XAD-16/HNO_3$Extraction Chromatography)

  • 이창헌;최광순;김정석;최계천;지광용;김원호
    • 대한화학회지
    • /
    • 제45권4호
    • /
    • pp.304-311
    • /
    • 2001
  • 경수로 사용후 핵 연료에 미량 함유되어 있는 핵분열생성물을 유도 결합 플라스마 원자방출분광법(ICP-AES)으로 분석하기 위하여 우라늄으로부터 학분열생성물을 추출 크로마토그래피로 분리, 회수하는 방법을 검토하였다. 우라늄 분리 분야에서 잘 알려져 있는 tri-n-butyl phosphate(TBP)를 추출제로 사용하여 몇 가지 Amberlite XAD 다공성 수지들에 대한 침윤능을 비교한 후 TPB침윤양이 가장 큰 Amberlite XAD-16을 지지체로 선택하였다. 사용후핵연료 용해용액과 화학조성이 유사한 모의 사용후핵연료 용해용액을 사용하여 TBP 침윤수지에 대한 핵분열생성물 원소들의 흡착거동을 조사하고, 분리에 미치는 여러 변수들을 최적화 하였다. Pd 및 Ru을 제외한 대부분의 핵분열생성물 원소들을 정밀도 3.1% 이하의 범위에서 정량적으로 회수할 수 있었다.

  • PDF

광릉 KoFlux 관측지 계곡에서의 국지순환 수치모의 (Numerical Simulation of Local Atmospheric Circulations in the Valley of Gwangneung KoFlux Sites)

  • 이승재;김준;강민석;빈드 말러 타쿠리
    • 한국농림기상학회지
    • /
    • 제16권3호
    • /
    • pp.246-260
    • /
    • 2014
  • 90m 고해상도 SRTM 지형자료를 장착한 WRF 수치모형을 이용하여 광릉 활엽수림 KoFlux 타워(GDK)와 침엽수림 KoFlux 타워(GCK)가 위치한 계곡 및 주변에서의 국지 대기순환을 식생-대기 이산화탄소 순환 및 미기상학적 관점에서 연구하였다. 지표 부근 온도와 바람에 대하여 모형과 관측 결과를 비교함으로써 모형의 전반적인 성능을 평가하였고, 연구 지역에 국지순환이 발생한 맑은 날(Case I)과 흐린 날(Case II) 사례를 선정하여 수치모의를 수행하고 그 결과를 정성적으로 분석하였다. 관측된 바람장은 GDK와 GCK 간에, 또 Case I과 Case II 간에 주간 및 야간 국지풍의 시작, 종료, 지속시간, 강도 등에 차이를 보였다. 모형의 수치모의 결과들은 광릉 KoFlux 타워 관측으로부터 그 가능성이 제기된 관측지 계곡의 배수류가 실제로 존재함을 증거하였다. 전반적으로 모형이 모의한 바람장은 아침의 배수류-사면활승풍 전이와 저녁의 사면활승풍 역전 등을 포함하여 계곡 및 주변에서 관측된 국지풍의 일변화를 현실적으로 모사하였다. 또한 국지풍 간 상호작용의 복잡성도 지시하였는데, 가령 주간에 광릉 관측지 계곡 내부의 서풍은 반드시 산풍인 것은 아니었으며, 종종 약한 종관규모 바람 또는 서쪽에서 불어온 해풍과 같은 보다 큰 규모의 중규모 바람 등 다른 풍계와 결합이 되어 있었다. 광릉 생태계의 에너지, 물질, 정보 흐름의 시공간적 변동을 입체적으로 이해하는데 있어서 이러한 고해상도 국지순환 수치모의 결과는 상당히 유용한 것으로 판단되며, 구축된 국지모의 시스템을 지속적으로 개선하는 노력이 향후 뒤따라야 할 것이다. 아울러, 다른 농림생태계 관측지도 모의 영역에 포함시켜 모형 결과의 활용도를 넓힐 필요가 있다.

반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(II) -구조개선을 중심으로 (A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter(II) -Structural Improvement)

  • 김진욱;정유진;유정근;손병현
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.985-992
    • /
    • 2011
  • 복합 후처리장치의 최적 모델 개발을 위해 반응기 내부 유동 특성 및 유량 분배 수준 등과 관련지어 3차원 전산유체역학(CFD)을 수행하였다. 백필터의 각 격실별로 유량 분배가 크게 차이가 발생해 반건식 반응기(SDR)에 편류현상이 발생할 것으로 예측되어 백필터에 균등한 유량 분배를 위한 구조 개선이 시급한 것으로 나타났다. 이를 위해, 장치에 3가지 수정.보완(플래넘 구조 개선, 풍도 오리피스 설치, 복수의 흡인 덕트 설치)이 이루어졌다. 이 중에서 플래넘 구조 개선, 풍도 오리피스 설치가 가장 합리적일 것으로 판단된다. 본 해석을 이용하여 수정 보완한 배가스복합 후처리장치는, 반건식 반응기와 백필터 처리부가 일체화되어 있어 장치가 콤팩트하고 설치면적이 적으며 운영 및 관리가 매우 편리할 것으로 판단된다.

복합재의 파괴와 hygrothermal 효과에 관한 연구 (Fracture and Hygrothermal Effects in Composite Materials)

  • Kook-Chan Ahn;Nam-Kyung Kim
    • 한국안전학회지
    • /
    • 제11권4호
    • /
    • pp.143-150
    • /
    • 1996
  • 본 연구는 선형, 비선형 hygrothermal 응력 문제를 위한 explicit-Implicit 유한요소 해석 모델 개발에 관한 것이다. 부가적으로 moilsture 확산 방정식, J-적분 평가를 위한 균열 요소 및 가상 균열 진전법이 도입된다. 시간 변화에 따른 균열 추진력을 계산하기 위하여 선형 탄성 파괴 역학(LEFM)이론이 고려되며 재료의 기공은 실온에서 액체 상태의 습기로 포화되어 있으며 온도가 상승함에 따라 증기화된다는 가정하에서 균열 추진력과 증기 효과의 관계가 연구된다. 이상 기체방정식은 각 시간 단계에서 증기에 의한 열역학적 압력을 계산하기 위하여 이용된다. 다공질 재료의 시간 종속 응답을 지배하는 방정식들은 혼합이론에 기초하며 다공질 재료의 유체 흐름을 위한 Darcy의 법칙과 Von-Mises 항복 기준을 포함하고 있는 Perzyna의 점소성 모델이 첨가된다. 또한 Green-Naghdi 응력률이 중첩된 강체 운동하에서 응력 텐서 invariant로 사용되며, 모델링을 위하여 사각요소가 이용되고 비선형 지배 방정식을 풀기 위하여 full Newton-Raphson법에 의한 반복법이 사용된다. 본 연구를 통하여 얻은 결과는 다음과 같다. 1) 본 유한요소 프로그램은 복합재의 hygrothermal 파괴 해석에 매우 유용하게 적용될 수 있다. 2) 습기의 온도에 의한 영향을 가지는 재료의 J-적분을 정확히 예측하기 위하여는 증기 효과를 고려하여야 한다. 왜냐하면 초기단계에 균열 전파력이 가속되기 때문이다. 3) 본 해석을 위해 Uncoupled scheme에 의한 결과도 Coupled scheme에 결과에 비해 아주 타당하므로 CPU 측면에서 매우 경제적인 Uncoupled scheme이 추천된다.

  • PDF

내열 내식용 Cr-Al반강자성계 스핀밸브막의 거대자기저항 효과 (Giant Magnetoresistance of Antiferromagnetic Cr-Al based Multilayer Spin-Valve with Anti-Corrosion and Thermal Stability)

  • 김병수;이성훈;이찬규
    • 한국자기학회지
    • /
    • 제8권6호
    • /
    • pp.362-368
    • /
    • 1998
  • 반강자성 Cr86Al14계 스핀밸브막의 자기특성과 내열 내식성에 대해 연구하엿다. Cr86Al14스핀밸브막의 자기적성질은 강자성층, 자성층 및 비자성층두께에 의존하였으며, glass/Cr86Al14(600$\AA$)/Ni81Fe19(50$\AA$)/Cu(40$\AA$)/Ni81Fe19(40$\AA$)구조에서의 교환결합자장(Hex)은 20 Oe, 자기저항비(MR ratio (%))는 2%를 나타내었다. Cr96Al14 및 Fe50Mn50 스핀밸브막은 annealing온도가 증가함에 따라 모두 Hex 및 MR비가 감소하는 경향을 나타내엇으나 FeMn막에 비해 CrAl막이 우수하여, FeMn막은 15$0^{\circ}C$, CrAl막은 25$0^{\circ}C$에서 Hex 및 MR비값을 상실하였다. 또한 가혹한 환경에서의 스핀밸브막의 부식저항성을 평가하고자 35$^{\circ}C$,90% 습도상태의 챔버내에서 Hex와 MR비값의 변화를 관찰한 결과 CrAl막의 경우에는 Hex 및 MR비 값이 시간이 경과해는 변화지 않았으나, FeMn막은 15일정도 경과하자 거의 상실하는 결과를 나타냈다. SEM관찰결과 FeMn막은 pitting이 나타났으며 15일정도 경과후에는 박리가 발생하였다.

  • PDF