• Title/Summary/Keyword: Counts Rate

Search Result 495, Processing Time 0.033 seconds

The Effect of Sunlight Exposure on the Survival of Microorganism Contaminated Bedding Materials (침구에 부착된 미생물 생존에 미치는 일광조사의 영향)

  • 최인려
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.2 no.1
    • /
    • pp.113-121
    • /
    • 2000
  • The effect of Sunlight exposure on reducing the microorganism counts in the bedding materials was experimented by using 3 kinds of microorganisms(S. aureus, K. pnenmoniae and E. coli) and 3 kinds of fabrics (cotton, silk and polyester). Counts of the microorganism were examined before and after sunlight exposure. The sunlights were controlled U.V and Daylight D50 using MacBeth artificial light source. The specimens were exposed for 5 min, 10 min and 30 minutes under the $20^{\circ}C$ and 60% R.H, distance is 50cm from the light source. Results were as follows, 1. The reduction rate of the 3kinds of microorganisms was remarkably great under the U.V exposure. The U.V. exposure was very effective way to sterlize the bedding materials in the house care. 2. S. aureus was the most susceptible to U.V. exposure and the sunlight exposure. E. coli was the most resistant to the U.V and the sunlight exposure. 3. The reduction rate of the 3 kinds of fabrics was not significantly different. The polyester is more resistant than the silk and the cotton. Those were shown good reduction rate if all kinds of microorganism under the U.V and daylight.

  • PDF

Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

A Study of Syllable Maximum Repetition Rate for Stimuli, Age and Sex (검사어 및 성별.연령에 따른 음절 최대 반복 속도에 대한 연구)

  • 최홍식;차정민;심현섭
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.1
    • /
    • pp.55-60
    • /
    • 2001
  • Background and Objectives : Syllable Maximum Repetition Rate(MRR) is ability to repeat rapidly the articulators and is assessed for oromechanism function as one of the MPT. MRR is measured by rate(counts/sec), also simultaneously considered accuracy and consistency. The objective of the present was to examine stimuli effects and age and sex differences for MRR. Materials and Method : This study was participated 60 normal males and females(1 : 1) who were divided into two groups young(<40 years old) and old($\geq$40 years old). Stimuli were $/{P^=}a/,/{t^=}a/,/{k^=}a/,/{P^h}a/,/{t^h}a/,/{k^h}a/,/{P^=}{at^=}{ak^=}a/$ for, manner(tense and aspirated) of articulation, $/{p^h}{at^h}{ak^h}a/,/{t^h}{ap^h}{ak^h}a/$ for the effect of the order of syllable, glide /u-i/ for coordination of lip and tongue, interrupted vowel /i/ for laryngeal function. Results : There were little differences in two age groups and sex and manner of articulation for MRR tasks. The fastest average MRR of the single syllable included in this study was $/{t^=}a/$. significant differences existed between MRR for ${p^h}{at^h}{ak^h}a/ and /{t^h}{ap^h}{ak^h}a/$, which suggested that MRR was affected by the order of the syllables. MRR for interrupted vowel /i/ was about 2 counts/sec slower than average rate of 1 syllables. Conclusion : From these results, the order of the syllables was a crucial variable in MRR. rather than age or sex. There were no difference age, sex and manner of rate. The interrupted vowel repetition rate was slightly slow used and can provide basic information to assess the speech mechanism and can be useful to develop effective stimuli to differentiate the disordered group from normal.

  • PDF

Plug & Play quantum cryptography system (Plug & Play 양자암호 시스템)

  • Lee, Kyung-Woon;Park, Chul-Woo;Park, Jun-Bum;Lee, Seung-Hun;Shin, Hyun-Jun;Park, Jung-Ho;Moon, Sung-Wook
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.45-50
    • /
    • 2007
  • We present a auto compensating quantum key distribution system based on optical fiber at 1550nm. In the quantum key transmission system, main control board and phase modulation driving board are fabricated for auto controlling quantum key distribution(QKD). We tested the single photon counts per dark counts for a single photon detector, quantum key distribution rate($R_{sift}$) and the quantum bit error rate (QBER). Quantum bit error rate of 3.5% in 25km QKD is obtained. This system is commercially available.

High Rate Dissolved Air Flotation (DAF) for the Removal of Algae Species (유입원수 조류제거를 위한 high rate DAF 최적화 연구)

  • Jung, Woosik;An, Ju-Suk;Song, Keun-Won;Oh, Hyun-Je
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.415-419
    • /
    • 2017
  • In recent years there have been large increases in the hydraulic loading rates used to design dissolved air flotation (DAF) facilities for drinking water applications. High rate DAF processes are now available at loading rates of 20 to $40m^3/m^2{\cdot}h$. This research evaluated dissolved air flotation as a separation method for algae and organic compounds from water treatment plants. During the service period of 2016. 5. to 2017. 6., DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU). As a result of analyzing the algae cell counts in the influent source, it was expressed at 100-120 cells/mL. In DAF treated water, the removal efficient of alge cell counts was found to be upto 90%. The stable turbidity and algae removal were confirmed by operating the high rate DAF process under the condition of the surface loading rate of $30m^3/m^2{\cdot}hr$.

Effects of Aloe arborescens on Survival and Blood Picture of Cobalt-60 Gama Irradiated Mice (Aloe arborescens 투여가 Cobalt-60 감마선 조사를 받은 마우스의 생존율 및 혈액상에 미치는 영향)

  • Sung Jai-Ki;Choi Min-Cheol;Kim Dong-Jun;Hwang Sung-Wook
    • Journal of Veterinary Clinics
    • /
    • v.8 no.1
    • /
    • pp.109-117
    • /
    • 1991
  • This experiment was carrid out to investigate whether Aloe arborescens had a radioprotective effect in cobalt-60 gamma irradiated(600 and 700ra4s) mice. The survival ratio of mice for 30 days and blood pictures were investigated. 1. The survival ratios of 600ra4s gamma Irradiated(dose rate 50rads/min.) in pre-irradiation aloe administered group(A), post-irradiation aloe administered group(B) and control group were 73.3%, 72.3% and 63.3%, and those of 700ra4s groups were 63.3%, 60.0% and 51.7%, respectively. 2. The total leucocyte counts of aloe administered groups were less decreased and more rapidly recovery to normal level than those of control group. 3. The lymphocyte counts were rapidly decreased on the 1st day after irradiation in all experimental groups than those of control group. 4. The recovery effects of total leucocyte counts of pre-irradiation aloe administered groups were superior to those of post-irradiation aloe groups and control group.

  • PDF

Joint Modeling of Death Times and Counts Considering a Marginal Frailty Model (공변량을 포함한 사망시간과 치료횟수의 모형화를 위한 주변환경효과모형의 적용)

  • Park, Hee-Chang;Park, Jin-Pyo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.9 no.2
    • /
    • pp.311-322
    • /
    • 1998
  • In this paper the problem of modeling count data where the observation period is determined by the survival time of the individual under study is considered. We assume marginal frailty model in the counts. We assume that the death times follow a Weibull distribution with a rate that depends on some covariates. For the counts, given a frailty, a Poisson process is assumed with the intensity depending on time and the covariates. A gamma model is assumed for the frailty. Maximum likelihood estimators of the model parameters are obtained. The model is applied to data set of patients with breast cancer who received a bone marrow transplant. A model for the time to death and the number of supportive transfusions a patient received is constructed and consequences of the model are examined.

  • PDF

Monitoring of Rotational Movements of Two Piston Rings in a Cylinder Using Radioisotopes

  • Jung, Sunghee;Jin, Joonha
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.423-431
    • /
    • 1999
  • A radiotracer technique has been developed to monitor the rotational movement of two piston rings in one cylinder during engine operation. The rings were labeled with two different kinds of radioisotopes, i.e. $^{60}$ Co and $^{192}$ Ir, for identification of the top ring from the second ring. The radiotracers were implanted in a small hole bored on the inner side of each piston ring. The rings were installed in a single cylinder hydrogen engine and three Nal scintillation detectors were mounted around the engine block to measure the gamma radiation. The angle of ring-gap orientation was determined from the radiation counts measured with the three detectors during engine operation. Two windows (upper window for $^{60}$ Co and lower window for $^{192}$ Ir) were set on each ratemeter to count radiation from the two isotopes separately. Procedure to convert the radiation counts to the position of the ring gap was established. With the software programmed with MS-Visualbasic, radiation counts were compared with the reference responses that were measured at angular intervals of 10$^{\circ}$for each piston ring in advance of the experiment. The result was used for the evaluation of the relationship between the orientation of ring-gaps and oil consumption. It was found that an increase in the oil consumption rate of a specific operation condition was closely related to the relative phase angle of the two piston rings.

  • PDF

Characterization of Stress Corrosion Cracking at the Welded Region of High Strength Steel using Acoustic Emission Method (음향방출법에 의한 고 장력강 용접부의 부식손상 특성 평가)

  • Na, Eui-Gyun;Kim, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.212-219
    • /
    • 2003
  • This study is to evaluate the characteristics of SCC at the welded region of high strength steel using acoustic emission(AE) method. Specimens were loaded by a slow strain rate method in synthetic seawater and the damage process was monitored simultaneously by AE method. Corrosive environment was controlled using the potentiostat, in which -0.8V and -1.1V were applied to the specimens. In the case of one-pass weldment subjected to -0.8V, much more AE counts were detected compared with the PWHT specimen. It was verified through the cumulative counts that coalescence of micro cracks and cracks for the one pass weldment with -0.8V were mostly detected. In case of the one pass weldment subjected to -1.1V, time to failure became shorter and AE counts were produced considerably as compared with that of the two pass weldment. It was shown that AE counts and range of AE amplitude have close relations with the number and size as well as width of the cracks which were formed during the SCC.