• Title/Summary/Keyword: Counter Rotating Axial Fan

Search Result 13, Processing Time 0.027 seconds

Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Fan (엇회전식 축류홴의 공력 특성에 관한 실험적 연구)

  • Choi, Jin-Yong;Cho, Lee-Sang;Cho, Jin-Soo;Won, Eu-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.441-446
    • /
    • 2000
  • The experiments of the Aerodynamic characteristics of a counter-rotating axial fan were carried out. The performance tests of a single and a counter-rotating axial fan were carried out based on the Korean Standard Testing Methods for Turbo-fans and Blowers(KS B 6311). The performances of single and counter-rotating axial fans were obtained and compared with each other. The flow fields of a counter-rotating axial fan at the peak efficiency point were measured using a five-hole probe. As a result, compared with the performance of a single-rotating axial fan, that of a counter-rotating axial fan was superior. And it is confirmed that most of the swirl flow generated by the front rotor was eliminated by the rear rotor.

  • PDF

Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Flow Fan (엇회전식 축류 펜의 공력 특성에 관한 실험적 연구)

  • Choe, Jin-Yong;Jo, Lee-Sang;Jo, Jin-Su;Won, Yu-Pil
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.201-210
    • /
    • 2002
  • Experiments were done for performance and flow characteristics of a counter-rotating axial flow fan. Performance curves of a counter-rotating axial flow fan were obtained and compared by varying the blade pitch angles. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe and a slanted hot-wire. The velocity profiles between the hub and tip of the fans were measured and analyzed at the peak efficiency point. The peak efficiency of the counter-rotating axial flow fan was improved about 15% respectively, compared with the single rotating axial fan. The single rotating axial flow fan showed relatively law efficiency due to the swirl velocities behind rotor exit which produced pressure losses. The counter-rotating axial flow fan showed that the swirl velocity generated by the front rotor was eliminated by the rear rotor and the associated dynamic pressure is recovered in the from of the static pressure rise.

Numerical and Experimental Analyses of the Aerodynamic Characteristics of a Counter Rotating Axial Fan (엇회전식 축류홴의 공력 특성에 관한 전산 해석 및 실험)

  • Cho, Jin-Soo;Won, Yu-Phil;Lee, Moon-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.325-337
    • /
    • 2000
  • A study was done on the numerical and experimental analyses of the aerodynamic characteristics of a counter rotating axial fan. The numerical analysis uses the frequency domain panel method developed for the aerodynamic analysis of interacting rotating systems, which is based on the unsteady lifting surface panel method. Each stage of interaction involves the solution of an isolated rotor, the interaction being done through the Fourier transform of the induced velocity field. Numerical results showed good agreements with other experimental data for single and counter rotating propeller systems. And they were compared with the experimental results of the counter rotating axial fan studied in the present paper. The performance test was carried out based on the Korean Standard (KS B 6311). It was focused on the relative efficiency increase of a counter rotating system for a single rotating one, and effects of the axial distance between the front and rear rotors on overall fan performances were investigated. As a result, it was shown that the counter rotating axial fan has the efficiency 14% higher than the single rotating one at peak efficiency points.

Numerical analyses on the Aerodynamic Characteristics of a Counter-rotating Axial Flow Fan (고성능 엇회전식 축류팬의 공력특성에 대한 전산해석)

  • Cho, Leesang;Cho, Jinsoo
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.1
    • /
    • pp.37-40
    • /
    • 2015
  • Numerical analyses on the aerodynamic characteristics of a counter rotating axial flow fan is carried out using the frequency domain panel method. Front rotor and rear rotor blades of a counter rotating axial fan are designed by using the simplified meridional flow analysis method with the radial equilibrium equation and the free vortex design condition, according to design requirements. Performance characteristics of a counter rotating axial flow fan are estimated for the variation of design parameters such as the hub to tip ratio, the taper ratio and the solidity. Pressure losses were higher at leading edge and hub region of rotor blades. Characteristic curve of the counter rotating fan was overpredicted without consideration of viscous effect.

Experimental Study on the Aerodynamic Characteristics of a Two Stage and a Counter-Rotating Axial Flow Fan (2단 축류팬과 엇회전식 축류팬의 공력 특성에 관한 실험적 연구)

  • Cho, Lee-Sang;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.541-547
    • /
    • 2000
  • Experiments were done for the comparison of performance and flow characteristics between a two stage axial flow fan and a counter-rotating axial flow fm. The fan performance curves were obtained by the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe by the non-nulling method. Each stage of the two stage axial flow fan used for the present study has an eight bladed rotor and thirteen stator blades. The front and the rear rotor of the counter-rotating axial flow fan have eight blades each and are driven by coaxial counter rotating shafts through a gear box located between the rear rotor and the electric motor. Both of the two axial fan configurations use identical rotor blades and the same operating conditions for the one-to-one comparison of the two. Performance characteristics of the two configurations were obtained and compared by varying the blade setting angles and axial gaps between the blade rows. The passage flow fields between the hub and tip of the fans were measured and analyzed for the particular operating conditions of peak efficiency, minimum and maximum pressure coefficients.

  • PDF

Experimental Study on the Aerodynamic Characteristics of a Two-Stage and a Counter-Rotating Axial Flow Fan (2단 축류홴과 엇회전식 축류홴의 공력특성에 관한 실험적 연구)

  • Cho, Jin-Soo;Cho, Lee-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1281-1292
    • /
    • 2001
  • Experiments were done for the comparison of performance and flow characteristics between a two -stage axial flow fan and a counter-rotating axial flow fan. Each stage of the two -stage axial flow fan used fur the present study has an eight bladed rotor and thirteen slater blades. The front and the rear rotor of the counter - rotating axial flow fan have eight blades each and are driven by coaxial counter ro latins shafts through a gearbox located between the rear rotor and the electric motor. Both of the two axial fan configurations have identical rotor blades and the same operating condition fur the one -to-one comparison of the two. Performance curves of the two configurations were obtained and compared by varying the blade pitch angles and axial gaps between the blade rows. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fa n flow characteristics were measured using a five-hole probe by a non-nulling method. The velocity profiles between the hub and tip of the fans were measured and analyzed at the particular operating condition s of peak efficiency, minimum and maximum pressure coefficients. The peak efficiency of the counter-rotating axial fan was improved about 2% respectively, compared with the two stage axial fan. At the minimum pressure coefficient point of the two stage axial fan, the fan inlet flow patterns show that axial velocity highly decreased in the vicinity of the blade tip region. Also, the reverse flow took place at the blade tip.

Experimental Study on the Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan (엇회전식 축류팬의 비정상 유동특성에 관한 실험적 연구)

  • Cho, Lee-Sang;Choi, Hyun-Min;Kang, Jeong-Seek;Cho, Jin-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.305-310
    • /
    • 2007
  • For the understanding of the complex flow characteristics in the counter-rotating axial flow fan, it is necessary to investigate the three-dimensional unsteady flow fields in the counter-rotating axial flow fan. This information is also essential for the prediction of the aerodynamic and acoustical characteristics of the counter-rotating axial flow fan. Experimental study on the three-dimensional unsteady flow in the counter-rotating axial flow fan is carried out at the design point(operating condition). Three-dimensional unsteady flow fields in the counter rotating axial flow fan are measured at the cross-sectional planes of the upstream and downstream of each rotor using the $45^{\circ}$ inclined hot-wire. Three-dimensional unsteady flow fields in the counter-rotating axial flow such as the wake, the tip vortex and the tip leakage flow are shown the form of the velocity vectors and the velocity contours.

  • PDF

Experimental Study on the Three Dimensional Unsteady Flow in a Counter-Rotating Axial Flow Fan (엇회전식 축류팬의 3차원 비정상 유동에 관한 실험적 연구)

  • Park, Hyun-Soo;Cho, Lee-Sang;Cho, Jin-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1005-1014
    • /
    • 2004
  • Experiments were done for the three dimensional unsteady flow in a counter-rotating axial flow fan under peak efficiency operating condition. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional flow patterns were investigated through the acquired data by the 45$^{\circ}$ inclined hot-wire. Flow characteristics such as tip vortex, secondary flow and tip leakage flow were confirmed through axial, radial and tangential velocity vector plot. It has been found that the radial and tangential velocity components disappeared, while the axial velocity component highly increased as soon as the tip vortex was generated. It has been observed that secondary flow and turbulence intensity which were increased by the front rotor were dissipated passing through the rear rotor. As the result the energy loss of the counter rotating axial flow fan decreased at the downstream of rear rotor. Also, it has been verified that tip vortex pattern of the rear rotor was dampened because the tip vortex generated by front rotor was mixed with that of the rear rotor.

Experimental Study on the Unsteady Flow under Various Operating Conditions of a Counter Rotating Axial Flow Fan (엇회전식 축류팬의 작동조건 변화에 따른 비정상 유동에 관한 실험적 연구)

  • Kang, Hyun-Koo;Cho, Lee-Sang;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1389-1394
    • /
    • 2004
  • Experiments were done for the unsteady flow in a counter rotating axial flow fan near peak efficiency and stall point. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional passage flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Comparison of flow characteristics between two different operating conditions such as tip vortex, secondary flow and turbulence intensity were performed through the analyses of axial, radial and tangential velocity distributions. As a result, tip vortex and secondary flows are enforced and measured obviously at stall point.

  • PDF

Experimental Study on the Three Dimensional Unsteady Flow in a Counter Rotating Axial Flow Fan (엇회전식 축류팬의 3 차원 비정상 유동에 관한 실험적 연구)

  • Park, Hyun-Soo;Cho, Lee-Sang;Kang, Hyun-Koo;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.822-827
    • /
    • 2003
  • Experiments were done for the three dimensional unsteady flow in a counter rotating axial flow fan under stable operating condition. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Flow characteristics such as tip vortex, secondary flow and tip leakage flow were confirmed through axial, radial and tangential velocity vector plot. Swirl velocity, which was generated by the front rotor, was recovered in the form of static pressure rise by the rear rotor except for hub and tip regions.

  • PDF