• Title/Summary/Keyword: Counter Current Flow Limit

Search Result 12, Processing Time 0.018 seconds

An Experimental Study on the CCFL in Narrow Annular Gaps with Large Diameter (곡률 반경이 큰 환상관 간극에서 CCFL에 대한 실험 연구)

  • Lee, Seung-Jin;Jeong, Ji-Hwan;Park, Rae-Joon;Kim, Sang-Baik;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.795-800
    • /
    • 2000
  • A CCFL(Counter Current Flow Limit) test have been performed in narrow annular gaps with large diameter, because it has been confirmed that the CCFL phenomena affected the critical power in hemispherical narrow gap geometries from the SONATA(Simulation Of Naturally Arrested Thermal Attack)-IV (In-Vessel)/VISU(Visualization)-II experiments. The objectives of the CCFL experiments are to investigate the small gap sizes(1, 2mm) effect on CCFL under the large diameter condition and to confirm the findings of the VISU-II study that global dryout in hemispherical narrow gaps was induced by the CCFL. The test section was made of acrylic resin to allow visual observation on the two-phase flow behaviors inside annular gaps. It was observed from visualization that a part of water supplied was accumulated in the upper plenum and a significant increase in the differential pressure across the gap was occurred, which was the definition of the CCFL occurrence in this experimental study. From the experimental results in annular gap with large diameter it can be known that an increase in the differential pressure was not big at small air flow-rates. When the CCFL was occurred, the differential pressure across gaps was increased significantly and a water accumulated in the upper plenum. The occurrence of CCFL was correlated using the Wallis parameter.

  • PDF

Assessments of FLECHT SEASET Unblocked Forced Reflood Tests Using RELAP5/MOD3 (RELAP5/MOD3 코드를 이용한 FLECHT SEASET의 강제 재관수 실험에 대한 평가)

  • Baek, Joo-Seok;Lee, Won-Jae;Lee, Sang-Yong;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.297-310
    • /
    • 1992
  • FLECHT SEASET unblocked forced reflood tests are assessed using Apollo version of RELAP5/MOD3 5M5. The main purpose of the study is to examine the code predictability under forced reflood conditions having different initial power levels and flooding rates. Among various test matrices, the assessment calculations are performed for the test numbers 31701 31302, 31203, 31805, 34524, 31021, 34006 and 35807 These have been selected because they have similar initial conditions but different initial peak rod powers or flooding rates. In addition, various sensitivity calculations are performed for test number 31203 on the improved models of RELAP5/MOD3. Those are for the effect of Counter Current Flow Limit (CCFL) option at the outlet junction of the test section, for the effect of grid modelling on the interfacial drag calculations as well as on the heat structure calculations, and for the effect of nodalization and the time step size. The results of sensitivity studies show that the improved models of RELAP5/MOD3 enhance the code predictability. The assessment results show that the RELAP5/MOD3 has a tendency to underpredict the turn around temperature and the turn around time. But RELAP5/MOD3 silghtly overpredicts the turn around temperature for high flooding rate. The results also show that the calculated quenching by RELAP5/MOD3 is delayed with the increase of the rod power or the decrease of the flooding rate.

  • PDF