• Title/Summary/Keyword: Count rate

Search Result 875, Processing Time 0.034 seconds

AE Count Rate and Crack Growth Rate under Low Cycle Fatigue Fracture Loading (저주기 피로 파괴 하중하에서 AE수 변화율과 균열성장율에 관한 연구)

  • 이강용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.252-256
    • /
    • 1989
  • In the low cycle fatigue fracture testing with KS(or JIS) SS41, crack growth rate, AE count rate and J-integral range are measured to get empirical relations between crack growth rate and J-integral range, AE count rate and J-integral range as well as AE count rate and crack growth rate. All the relations are shown to be linear on the log-log graphs. It is also shown that the linear relations can be formulated by using Dunegan's assumption and elastic-plastic fracture mechanics along with the well-known relation of crack growth rate and J-integral range. It is concluded that the differences between experimental and theoretical values are due to Dunegan's assumption.

Survey on Bacteriological Contamination of Restaurants in Seoul Area (서울지역 대중음식점의 위생상태에 관한 미생물학적 조사연구 - 물수건, 냉면육수, 엽차를 중심으로 -)

  • Shin Jung Sik;Park Sang Huun
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.41-46
    • /
    • 1986
  • This study was performed to investigate the sanitation of restaurants in Seoul Area. The subjects were 153 wet towels, 64 cold noodle soup and 190 barely tea. The results were as follows: In wet towels: The detected rate of standard plate counts was $86.9\%$ (133 samples) and average count was $1.8\times10^3/g$ $the detected rate of coliform was $37.9\%$ (58 samples) and average count by MPN method was $2.0\times10^3/100g$, the detected rate of fecal coliform was $15.7\%$ (24 samples) and average count by MPN method was $3.2\times10/100g$. In cold noodle soups: The detected rate of standard plate counts was $100\%$ (64 samples) and average count was $9.4\times10^5/ml$, the detected rate of coliform was $75\%$ (48 samples) and average count by MPN method was $6.0\times10^5/100ml$, the detected rate of fecal coliform was $51.6\%$ (33 samples) and average count by MPN method was $3.4\times10^3/100ml$. In barely tea: The detected rate of standard plate counts was $87.4\%$(166 samples) and average count was $5.8\times10^3/ml$the detected rate of coliform was $66.3\%$ (126 samples) and average count by MPN method was $3.9\times10^3/100ml$, the detected rate of fecal coliform was $32.6\%$ (62 samples) and average count was by MPN method was $4.7\times10/100ml$.

  • PDF

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

A Method for Determining Dead Times of a G.M. Defector as a Function of the Count Rate

  • Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.3-7
    • /
    • 1971
  • A method for determining dead times of a G.M. detector as a function of the count rate has been investigated using the Mn$^{56}$ radioactive sample. The formula, (equation omitted), seems to be useful for determining a relation between the dead time and the count rate. Here (equation omitted)(N$_1$) is the dead time for the count rate N$_1$, N$_1$is the count rate at time zero, Nt is the count rate at time t, λ is the radioactive decay constant of the sample used, and t is the time between the first and second runs. When all the counting data were corrected for the dead times evaluated with this formula and then a variation of these corrected counting data with rime was observed, the results showed quite a good agreement with the published data for the radioactive decay of Mn$^{56}$ . Besides, it appears that the dead time decreases as the count rate increases in a dead time-to-count rate relation obtained by the same formula.

  • PDF

A study of feedback resister series effects for stabilizing the gain of the photomultiplier with counting rate increase (계수율 증가에 따른 광증배관의 이득안정을 위한 궤환저항 효과에 관한 연구)

  • 천희영;신현국
    • 전기의세계
    • /
    • v.29 no.7
    • /
    • pp.455-459
    • /
    • 1980
  • The gain change of the photomultiplier which occurs as the count rate increased was examined. and simple feedback resistor series was introduced between 7th and 9th dynode for compensating the gain change. The effect of the feedback resistor series was considerably good to reduce the gain change. With the feedback resistor, the gain change was only 1.9%, when count rate was increased from 514 CPS (counts per second) to 1250 CPS. Without the feedback resister, the gain change was 6.9%, when the count rate was increased from 530 CPS to 1250 CPS.

  • PDF

Fracture Detection of Milling Cutter Using Cutting Force and Acoustic Emission Signals (절삭력과 음향방출 신호를 이용한 밀링공구의 파손 검출)

  • Maeng, Min-Jae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.1
    • /
    • pp.28-37
    • /
    • 2004
  • An on-line monitoring system of endmill failure such as weal, chipping, and fracture is developed using AE, cutting force Characteristic variations of AE and cutting force signals due to endmill failure are identified as follows. When endmill fracture occurs, AE count rate shows a rapid Increase in conjunction with a subsequent decrease while a standard deviation of the principal cutting force Increases significantly. The increase of AE count rate precedes the Increase of standard deviation of principal cutting force. Chipping results in relatively small increase and decrease of AE count rate without any significant variation of the cutting force Gradual increase of AE count rate and mean principal cutting force are Identified to be related with the wear of cutter. A cutter fracture detection algorithm is developed based on the present results. The signals me normalized to enhance the applicability of the algorithm to Wide those of fresh cutters, and qualitative characteristics of AE signals encountered at the moment of fracture are employed. It is demonstrated that the algorithm can detect the cutter fracture successfully.

  • PDF

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

A STUDY ON PULSE RATE SYSTEM

  • Kim, H. K.;S. C. Han;K. K. Min;W. Huh
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.535-537
    • /
    • 1998
  • In this paper, we devised a pulse rate detection system to provide basic clinical index of cold-hot diagnosis of oriental medicine. The system consists of pulse signal detection, respiration signal detection, electrocardiograph detection, A/D conversion and computer system parts. We define a pulse rate by a pulse count to the respiration period inspiration pulse rate by a pulse count to the inspiration period, and expiration pulse rate by a pulse count to the expiration period. The clinical experiments for normal Person to evaluate the pulse rate detection system show the pulse/respiration ratio of 4.30${\pm}$1.03, the pulse/inspiration ratio of 1.60${\pm}$0.32, the pulse/expiration ratio of 2.37${\pm}$0.75.

  • PDF

Monitoring of Tool Wear using AE Signal in Interrupted cutting (단속절삭에서 AE신호를 이용한 공구마멸의 감시)

  • 김정석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.2
    • /
    • pp.112-118
    • /
    • 1997
  • Characteristics of AE(Acoustic Emission) signal is related to cutting conditions, tool materials, and tool geometry in metal cutting. Relation between AE signal and tool wear was investigated experimentally. Experiment is carried out by interrupted cutting for SCM420 workpiece with TiN coating tool on HSS material. AE RMS voltage and count per event were increased according to tool wear. The major results are as follows : 1) AE RMS value is nearly constant as cutting speed changes, but is rapidly increase as feed rate increases. 2) AE RMS value and Count per Event increase as tool wear increases. 3) It is more effective to monitor tool wear by Incremental rate of AE RMS value than by Incremental rate of count per event.

  • PDF

Effects of Bojungikkitang on the immunosuppression induced by methotrexate in rats (보중익기탕(補中益氣湯)이 Lymphocyte와 CD4+ T cell에 미치는 영향(影響))

  • Kim Mi-Ji;Kim Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.211-230
    • /
    • 1998
  • Introduction The effects of Bojungikkitang on the immunosuppression induced by methotrexate in rats were investigated in this experiment. The multiple parameters of immunity assessed in. each rats includes the rate of body weight loss, weight changes in thymus, spleen and axillary lymphnode. The number of lymphocyte and CD4+ T cell count in blood, thymus, spleen and axillary lymphnode were also measured. Methodology Male Sprague-Dawley rats were chosen as an experiment object and were divided into 3 groups by a random selection. Each group consisted 6 rats. The normal group didn't receive any treatment. The control group was administered methotrexate for 4 days. The sample group was administered with both Bojungikkitang and methotrexate for 4 days. The dosage of medication was 2cc/day, 1cc given at 10AM and another 1cc given at 5PM. Results The rate of body weight loss was significantly decreased in the sample group. The weight of thymus was significantly increased in the sample group while the weight of spleen did not show much increase. Blood CD4+ T cell count, thymus lymphocyte count, thymus CD4+ T cell count, spleen lymphocyte count, spleen CD4+ T cell count and axillary lymph node CD4+ T cell count were significantly increased in the sample group while blood lymphocyte count and axillary lymphnode lymphocyte count did not show much increase. Conclusion As one can witness from the above results, administration of Bojungikkitang played potent role in increasing immune system among the rats treated with methotrexate which induces immunosuppression. Overall increase of lymphocyte count and CD4+ T cell count in the sample group with Bojungikkitang effectively proves its ability to boost the immune system.

  • PDF