• 제목/요약/키워드: Cost-saving

검색결과 1,308건 처리시간 0.024초

철강산업체 전기로(EAF) 설비에서 에너지절약 최신기술동향 (New Energy Saving Technology of Electric Arc Furnace in Steel Making Industry)

  • 오동환;박현규;박태준;임상국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.71-73
    • /
    • 2003
  • The paper discussed for energy saving technology of electric arc furnace (EAF) in steel making industry. The energy of EAF in steel making process is nearly 10% of total manufacturing cost. This paper is shown new trand of energy saving technology and future study analysis of technological evolution of the EAF by 2010 issued IISI.

  • PDF

수용가 수요관리용 전지전력저장시스템의 최적용량 산정방법 (Optimal Capacity Determination Method of Battery Energy Storage System for Demand Management of Electricity Customer)

  • 조경희;김슬기;김응상
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.21-28
    • /
    • 2013
  • The paper proposes an optimal sizing method of a customer's battery energy storage system (BESS) which aims at managing the electricity demand of the customer to minimize electricity cost under the time of use(TOU) pricing. Peak load limit of the customer and charging and discharging schedules of the BESS are optimized on annual basis to minimize annual electricity cost, which consists of peak load related basic cost and actual usage cost. The optimal scheduling is used to assess the maximum cost savings for all sets of candidate capacities of BESS. An optimal size of BESS is determined from the cost saving curves via capacity of BESS. Case study uses real data from an apartment-type factory customer and shows how the proposed method can be employed to optimally design the size of BESS for customer demand management.

제품군 디자인에서 공통속성의 활용이 사회적 효용에 미치는 영향 (Effects of Commonality Strategy in Product Line Design on Social Welfare)

  • 김길선
    • 한국경영과학회지
    • /
    • 제33권3호
    • /
    • pp.77-92
    • /
    • 2008
  • Commonality strategy is a popular design practice in designing a product line as it enables the firm cost saving and simplification in design, manufacturing, and distribution processes. However the issue of commonality has been mostly analyzed from a profit maximizing firm's perspective and, to our knowledge, there is no literature that deals with the issue from a different perspective. in this paper, we consider the issue of commonality strategy from a social welfare maximization perspective, and argue that commonality strategy used in designing of public goods can bring certain benefits not just for a firm but also for consumers, i.e., for society as a whole. While we assume certain cost saving in production process due to economies of scale under commonality strategy, we conceptualize two different effects of commonality strategy, utility effect due to cost saving and weighted-averaging effect, and show how these two effects interplay to determine the design of common attribute and desirability of commonality strategy. We also discuss how the implementation of commonality strategy differs under different objectives of a product line designer : social welfare and firm's profit maximization.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

환경친화형 주거단지지 계획에 관한 의식조사 - 공동주택 거주자와 전문가를 대상으로 - (A Survey on the Residents' and Experts' Consciousness to Planning of the Environment-Friendly Apartment Complex)

  • 정유선;윤정숙
    • 한국주거학회논문집
    • /
    • 제13권4호
    • /
    • pp.81-88
    • /
    • 2002
  • The purpose of this study is to accumulate basic data to establish planning direction and planning factors for the environment-friendly apartment complex. For this purpose, the survey has been conducted to residents living in an apartment housing and graduate students, architects and research experts in the field. The major findings of this study are as follows; 1) The basic concept of planning factors for environment-friendly apartment complex are energy saving, resources saving, minimizing environment pollution, natural harmony, regional identity and pursuit of residents' health & amenity. 2) For the planning factors of environment-friendly apartment complex, the residents had a great regard for aspect of Low-Impact (energy saving, resources saving, minimizing environment pollution). The experts, on the other hand, had a great regard for aspect of High-contact (natural harmony, regional identity). 3) It was increase of prime cost that the residents and experts regarded as the most important problem of planning and purchasing of environment-friendly apartment. It thus appears that the promotion of environmental consciousness of residents taking in the portion of increased cost is crucial parts and also that the role of the connected aspects such as administration, construction companies and residents must be redefined in order to manage problems caused in process of the development of it.

사무소건물 조명기기와 열원기기의 고효율기기로의 교체에 관한 경제성 검토 (Feasibility Study on Retrofitting Lighting and Heat Source Equipments in Office Buildings)

  • 이철구;김종대;임태순
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권2호
    • /
    • pp.13-18
    • /
    • 2016
  • Energy saving has been main concern, thus government supporting policies which are based on Fundamentals of Low-carbon Green Growth Act', 'Green Building Support Act, have been prepared in Korea. The objective of this study is to estimate energy conservation effectiveness and economic advantage assuming that lighting equipments and heat source equipments would be retrofitted. Office building, which has total floor area of $30,000m^2$, was a subject of this study. From the estimations, electric rate will be decreased by 62,886,000 won per year due to lighting equipments retrofit, and gas rate will be decreased 11,141,000 won or 17,332,000 won per year due to heat source equipments retrofit (in case of COP 1.2 or 1.5). Payback period of each case that are calculated by energy saving cost and retrofit cost are estimated 27.9 year, 38.6 year and 29.2 year, thus economic supporting policies is necessary for effective energy saving in buildings. Meanwhile payback period of heat source equipment for new building is estimated 6.1 year and 8.3 year.

사무소 건축물의 공조시스템 대수제어 여부에 따른 LCC 분석 (Life Cycle Costing through Operating Number Control of Air Conditioning Systems in Office Buildings)

  • 박률;정순성
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.981-988
    • /
    • 2002
  • Generally, the term "energy saving is economical" is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing the system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning system. For this reason, this research can provide the economics through operating number control as basic design data. The data obtained through assesment of Life Cycle Cost based on amount of yearly energy use, were produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating/cooling systems based on constant air volume conditioning system, which is widely used for medium and large office buildings in Busan.

Analysis of Economics through Control Method of Heat Source Equipment in Seasonal Air conditioning Building

  • Park, Yool;Kim, Samuel;Jung, Soon-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.209-217
    • /
    • 2003
  • The term “energy saving is economical” is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing a system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning systems. For this reason, this research can provide the economic operating number control method as basic design data. The data obtained through analysis of life cycle cost based on amount of yearly energy use, are produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating$.$cooling systems based on seasonal air conditioning system, which is widely used for medium and large size office buildings in Busan.

마이크로웨이브 센서를 이용한 에너지 절약시스템 개발 (Development of Energy Saving System Using the Microwave Sensor)

  • 정순원;이재진;구경완
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.404-407
    • /
    • 2008
  • Because of directly receiving the thing in which a microwave is reflected and comparing the frequency, the microwave sensor with doppler effect completely overcomes the problem of the passive infrared sensor. The microwave sensor with doppler effect well operates about a temperature, the dust, and the peripheral noise because of being dull in the most of ambient conditions. The system developed in this research is the electricity saving detection sensor which it senses the real time action of a man as the microwave sensor and automatically turns on the electric lamp and turns off, minimizes the electrical energy consumption. Since the microwave sensor is not influenced in the light, the dust, and the natural element like the ambient temperature, the effectiveness is considered to be superior to the passive infrared sensor being used currently. There was the energy reduction effect more than about 60% in the performed example which established this system. When this was compared with the construction cost, the cost of establishing payback period was about 1-1.5 year. The microwave sensor with doppler effect developed from this research result is convinced in the future to do enough for the electric energy saving.

IP 주소 제한을 이용한 PC 절전 시스템의 설계 (A Design of Power-saving PC System Using the IP Address Restriction)

  • 김홍윤
    • 디지털산업정보학회논문지
    • /
    • 제9권2호
    • /
    • pp.89-97
    • /
    • 2013
  • The green IT technology is being introduced in diverse sectors, especially in the data center and green computer sectors. Rack-type PCs, which have been developed by improving the computer hardware, are effective for data centers and large businesses, but they are not usually introduced in small organizations such as small and medium businesses and schools because they require high initial costs. Power-saving PC software enables the inexpensive power control, but the installation of the power-saving software in all computers in the organization is not an easy task. Computer users in the organization are usually not cooperative as they do not think the power-saving cost is directly related to themselves. In this paper, a technique wherein the server has a restriction in providing the IP address to the computers that has no power-saving software is proposed, so that users will cooperate in the PC power-saving system to avoid inconvenience. In order to provide restricted IP address periodically, the server makes a request of power-saving software installation check for user's PC. Proposed technique is more effective ways to save computer energy, because it does not depend on specific systems or organizations.