• 제목/요약/키워드: Corrugated Tube

검색결과 45건 처리시간 0.021초

곡률비가 다양한 코일 튜브에서의 열전달현상에 관한 연구 (A Study on the Heat Transfer Phenomena in Coiled Tubes with Variable Curvature Ratios)

  • 한규일;박종운
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1509-1520
    • /
    • 1998
  • An experiment was carried out for the fully developed turbulent flow of water in tube coils on the condition of uniform heat flux. The present work was conducted for various ranges for Dean number(1794~1321), Prandtl number (2.5~4.5), curvature ratio parameters (22~60). Heat transfer to steady viscous flow in coiled tubes of circular cross section was studied for fully developed velocity and temperature fields under the thermal boundary condition of uniform heat flux. The peripherally local Nusselt number correlated as a function of Dean and Prandtl numbers. We studied the flow in heat coiled tubes under the influence of both centrifugal and buoyancy forces in order to gain insight into the flow pattern. In the present study, we obtained three emperical formulas, $Nu_v=0.0231Re^{0.84}Pr^{0.4}(a/R)^{0.13}$ (vertical) $Nu_c=0.0241Re^{0.86}Pr^{0.4}(a/R)^{0.08}$ (corrugated) $Nu_h=0.0227Re^{0.84}Pr^{0.4}(a/R)^{0.09}$ (horizontal).

인위적으로 열화된 황색절연링형 금속플렉시블호스의 패턴 및 특성 (Patterns and Characteristics of Corrugated Stainless Steel Tubing for a Yellow Insulation Ring Type by Artificially Deteriorated)

  • 이장우;최충석
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.1-6
    • /
    • 2018
  • 본 논문은 배관용으로 사용되고 있는 황색절연링형(yellow insulation ring type) 금속플렉시블호스(CSST)를 인위적으로 열화(deterioration)시켜 소손되었을 때의 특성을 분석하는데 있다. 배관용 CSST는 튜브, 보호피막, 너트, 황색절연링, 패킹(packing), 이음쇠(socket)로 구성되어 있다. 그리고 튜브와 이음쇠 접속은 기밀성과 절연성능 향상을 위해 황색절연링과 고무 패킹을 사용한 것으로 판단된다. 실험에서 얻은 데이터를 95% 신뢰 구간에서 검증한 결과 AD (Anderson-Darling)는 0.945, P값은 0.015로 해석되었다. 배관용 CSST의 실험 데이터는 신뢰성이 있다는 것이 확인되었다. 가스 토치에 의해서 소손된 CSST의 산술적 평균 절연저항은 $16.7k{\Omega}$으로 가장 컸으며, 전기적인 소손을 입은 CSST는 상대적으로 가장 낮은 $208{\Omega}$, 정상 제품은 $1.72k{\Omega}$으로 분석되었다. 그러므로 화재 현장에서 수거한 CSST의 절연저항 값을 분석하면 소손 원인 판정에 활용할 수 있을 것이다. 또한, 대전류공급장치(PCITS)로 CSST에 최대 전류 97 A를 약 5 s 동안 흘린 결과 보호피막 및 절연링은 정상 제품과 차이가 없었으나 금속 튜브의 일부에서 용융이 형성된 것을 확인할 수 있었다.

Tubular Web Reduced Beam Section (TW-RBS) connection, a numerical and experimental study and result comparison

  • Zahrai, Seyed M.;Mirghaderi, Seyed R.;Saleh, Aboozar
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.571-583
    • /
    • 2017
  • A kind of accordion-web RBS connection, "Tubular Web RBS (TW-RBS)" connection is proposed in this research. TW-RBS is made by replacing a part of web with a tube at the desirable location of the beam plastic hinge. This paper presents first a numerical study under cyclic load using ABAQUS finite element software. A test specimen is used for calibration and comparison of numerical results. Obtained results indicated that TW-RBS would reduce contribution of the beam web to the whole moment strength and creates a ductile fuse far from components of the beam-to-column connection. Besides, TW-RBS connection can increase story drift capacity up to 9% in the case of shallow beams which is much more than those stipulated by the current seismic codes. Furthermore, the tubular web like corrugated sheet can improve both the out-of-plane stiffness of the beam longitudinal axis and the flange stability condition due to the smaller width to thickness ratio of the beam flange in the plastic hinge region. Thus, the tubular web in the plastic hinge region improves lateral-torsional buckling stability of the beam as just local buckling of the beam flange at the center of the reduced section was observed during the tests. Also change of direction of strain in arc shape of the tubular web section is smaller than the accordion webs with sharp corners therefore the tubular web provides a better condition in terms of low-cycle fatigue than other accordion web with sharp corners.

PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구 (A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS)

  • 이장우;최충석
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.121-127
    • /
    • 2016
  • 본 논문에서는 대전류공급장치(PCITS)에 의해 소손된 강이음쇠형(iron fittings type) 금속플렉시블호스(CSST)의 구조 및 전기적 특성을 해석하였다. CSST는 보호 피막, 튜브, 너트, 클램프 링, 플레어 캡, 소켓, 볼 밸브 등으로 구성되어 있다. CSST의 내전압 평가는 전기 충전부와 비충전부 사이에 교류 전압 220 V를 1분간 인가하여 견뎌야 한다. 직류 500 V에 의한 절연 성능의 평가는 온도 상승 시험 전에 $1M{\Omega}$ 이상, 시험이 끝난 후에는 $0.3M{\Omega}$ 이상을 요구한다. 정상 제품의 평균 저항은 $11.5m{\Omega}$이었으나 PCITS로 130 A를 흘려 소손된 제품의 평균 저항 $11.50m{\Omega}$이었다. 또한 130 A가 약 10 s 흘렀을 때 튜브의 보호 피막이 일부 용융되었고, 검정색의 연기가 발생하였다. 60 s 경과되면 튜브의 대부분이 적색으로 발열되며, 전류가 120 s 흘렀을 때는 적열 범위가 넓어졌다. 95%의 신뢰 구간(CI)의 검증에서 P 값은 0.019로 정규 분포를 갖지 못하였으나 Anderson-Darling (AD) 통계량은 0.896, 표준 편차는 0.5573 등으로 양호한 특성을 나타냈다.

배수개선공법개발에 관한 연구(I) -각종 지하배수용 암거재료의 배수성능- (Drainage Performance of Various Subsurface Drain Materials-)

  • 김철회;이근후;유시조;서원명
    • 한국농공학회지
    • /
    • 제21권3호
    • /
    • pp.104-120
    • /
    • 1979
  • I. Title of the Study Studies on the Development of Improved Subsurface Drainage Methods. -Drainage Performance of Various Subsurface Drain Materials- II. Object of the Study Studies were carried out to select the drain material having the highest performance of drainage; And to develop the water budget model which is necessary for the planning of the drainage project and the establishment of water management standards in the water-logged paddy field. III. Content and Scope of the Study 1. The experiment was carried out in the laboratory by using a sand tank model. The drainage performance of various drain materials was compared evaluated. 2. A water budget model was established. Various parameters necessary for the model were investigated by analyzing existing data and measured data from the experimental field. The adaptability of the model was evaluated by comparing the estimated values to the field data. IV. Results and Recommendations 1. A corrugated tube enveloped with gravel or mat showed the highest drainage performance among the eight materials submmitted for the experiment. 2. The drainage performance of the long cement tile(50 cm long) was higher than that of the short cement tile(25 cm long). 3. Rice bran was superior to gravel in its' drain performance. 4. No difference was shown between a grave envelope and a P.V.C. wool mat in their performance of drainage. Continues investigation is needed to clarify the envelope performance. 5. All the results described above were obtained from the laboratory tests. A field test is recommended to confirm the results obtained. 6. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as follows; $$D=\Sigma\limit_{t=1}^{n}(Et-R_{\ell}-I+W_d)..........(17)$$ 7. Among the various empirical formulae for potential evapotranspiration, Penman's formular was best fit to the data observed with the evaporation pans in Jinju area. High degree of positive correlation between Penman;s predicted data and observed data was confirmed. The regression equation was Y=1.4X-22.86, where Y represents evaporation rate from small pan, in mm/100 days, and X represents potential evapotranspiration rate estimated by Penman's formular. The coefficient of correlation was r=0.94.** 8. To estimate evapotranspiration in the field, the consumptive use coefficient, Kc, was introduced. Kc was defined by the function of the characteristics of the crop soil as follows; $Kc=Kco{\cdot}Ka+Ks..........(20)$ where, Kco, Ka ans Ks represents the crop coefficient, the soil moisture coefficient, and the correction coefficient, respectively. The value of Kco and Ka was obtained from the Fig.16 and the Fig.17, respectively. And, if $Kco{\cdot}Ka{\geq}1.0,$ then Ks=0, otherwise, Ks value was estimated by using the relation; $Ks=1-Kco{\cdot}Ka$. 9. Into type formular, $r_t=\frac{R_{24}}{24}(\frac{b}{\sqrt{t}+a})$, was the best fit one to estimate the probable rainfall intensity when daily rainfall and rainfall durations are given as input data, The coefficient a and b are shown on the Table 16. 10. Japanese type formular, $I_t=\frac{b}{\sqrt{t}+a}$, was the best fit one to estimate the probable rainfall intensity when the rainfall duration only was given. The coefficient a and b are shown on the Table 17. 11. Effective rainfall, Re, was estimated by using following relationships; Re=D, if $R-D\geq}0$, otherwise, Re=R. 12. The difference of rainfall amount from soil moisture depletion was considered as the amount of drainage required. In this case, when Wd=O, Equation 24 was used, otherwise two to three days of lag time was considered and correction was made by use of storage coefficient. 13. To evaluate the model, measured data and estimated data was compared, and relative error was computed. 5.5 percent The relative error was 5.5 percent. 14. By considering the water budget in Jinju area, it was shown that the evaporation amount was greater than the rainfall during period of October to March in next year. This was the behind reasonning that the improvement of surface drainage system is needed in Jinju area.

  • PDF