• Title/Summary/Keyword: Corrosion potentials

Search Result 116, Processing Time 0.027 seconds

Effects of Time and Current Density in Anodizing of Mg-Al Alloy in Alkaline Solution (알카리 수용액에서 Mg-Al 합금의 양극산화시 전류밀도와 양극산화 시간의 효과)

  • Jang Seok-Ki;Kim Seong-Jong;Kim Jeong-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.107-115
    • /
    • 2005
  • The effects on the formation of anodic oxide films on Mg-Al alloy (AZ91) in 1M-NaOH solution was investigated using parameters of current density and time during anodizing The general tendency has been confirmed that the increase of anodizing time improves the corrosion resistance. It is considered that the formation of anodic oxide film was increased by increasing the applied current and the anodizing time to generate active dissolution reaction In anodizing at constant current density. passivity potentials shifted to noble direction with increasing current densities. It was confirmed that oxygen quantify in anodic oxide films increased with anodizing time. The compact films above 4 $mA/cm^2$ were formed with the shape of an island in grooves at early stage and then grew with combination of the islands

Electronic Behaviors of Passive Films Formed on Fe-Cr and Fe-Cr-Mo Ferritic Stainless Steels Studied by Mott-Schottky and Cyclic Voltammetry Techniques

  • Kim, Suk-Won;Yoon, Sang-In;Lee, Jae-Bong
    • Corrosion Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.12-17
    • /
    • 2003
  • The effects of Cr content and film formation potential on electronic behaviors of the passive film on Fe-Cr alloys were investigated in borate buffer solution. Influence of pH on passive films of both Fe-Cr and Fe-Cr-Mo alloys was also investigated. Mott-Schottky and cyclic voltammetry techniques were used to elucidate electronic behaviors of passive films and their electrochemical characteristics. AES analysis of passive films was carried out. Results showed that doping density decreased as Cr content and film formation potentials increased. The addition of Mo to Fe-Cr alloy had little influence on donor densities in pH 9.2 solution but some effects on the decrease in donor densities in pH 1.6 acidic solution.

Bioinspired Nanoengineering of Multifunctional Superhydrophobic Surfaces

  • Choi, Chang-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.102-133
    • /
    • 2015
  • Nature, such as plants, insects, and marine animals, uses micro/nano-textured surfaces in their components (e.g., leaves, wings, eyes, legs, and skins) for multiple purposes, such as water-repellency, anti-adhesiveness, and self-cleanness. Such multifunctional surface properties are attributed to three-dimensional surface structures with modulated surface wettability. Especially, hydrophobic surface structures create a composite interface with liquid by retaining air between the structures, minimizing the contact area with liquid. Such non-wetting surface property, so-called superhydrophobicity, can offer numerous application potentials, such as hydrodynamic drag reduction, anti-biofouling, anti-corrosion, anti-fogging, anti-frosting, and anti-icing. Over the last couple of decades, we have witnessed a significant advancement in the understanding of surface superhydrophobicity as well as the design, fabrication, and applications of superhydrophobic coatings/surfaces/materials. In this talk, the designs, fabrications, and applications of superhydrophobic surfaces for multifunctionalities will be presented, including hydrodynamic friction reduction, anti-biofouling, anti-corrosion, and anti-icing.

  • PDF

Evaluation of Scc Susceptibility of Welded HAZ in Structual Steel(II) -Frcature Behavior in Cathodic Protection- (강 용접부의 응력부식크랙 감수성 평가에 관한 연구 II -음극방식에서의 파괴거동-)

  • 임재규;조정운;나의균
    • Journal of Welding and Joining
    • /
    • v.11 no.3
    • /
    • pp.61-74
    • /
    • 1993
  • The cause of corrosion failure found in structures or various components operating in severe corrosive environment has been attributed to stress corrosion cracking(SCC) which is resulting from the combined effects of corrosive environments and static tensile stress. Cathodic protection is an electrochemical method of corrosion control that is widely used in marine environment and primarily on carbon steel. A number of criteria are used to determine whether or not a structure is cathodically protected. In practice, -0.8V versus Ag/AgCl is the most commonly used for marine structures. This paper showed the combined effects of cathodic potential and slow, monotonic straining on the tensile ductility and fracture morphology of parents and friction welded joints for SM45C, SCM440 and SM20C steels in syntheic sea water(S.S.W.,pH:8.2). For the parent materials in cathodic potentials, the higher tensile strength is, the more susceptible SCC is. And the welded HAZ is more susceptible than the parent materials.

  • PDF

A Comparative Study of CrN Coatings Deposited by DC and Pulsed DC Asymmetric Bipolar Sputtering for a Polymer Electrolyte Membrane Fuel Cell (PEMFC) Metallic Bipolar Plate (DC 스퍼터법과 비대칭 양극성 펄스 스퍼터법으로 제작된 고분자 전해질 연료전지 금속분리판용 CrN 코팅막의 특성 연구)

  • Park, Sang-Won;Chun, Sung-Yong
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.390-395
    • /
    • 2013
  • Nanocrystalline CrN films were deposited on Si (100) substrates by means of asymmetric pulsed DC reactive magnetron sputtering. We investigated the growth behavior, corrosion resistance and mechanical properties of CrN films with a change in the duty cycle and pulse frequency. The grain size of the CrN films decreased from 25.4 nm to 11.2 nm upon a decrease in the duty cycle. The corrosion potentials for the CrN films by DC sputtering was approximately - 0.6 V, and it increased to - 0.3 V in the CrN films which underwent pulsed sputtering. The nanoindentation hardness of the CrN films also increased with a decrease in the duty cycle. This enhancement of the corrosion resistance and mechanical properties of pulsed sputtered CrN films could be attributed to the densification and surface smoothness of the microstructure of the films.

Long-term corrosion-resistance of an uncoated weathering steel and its on-line and in-situ measurements (무도장 내후성강의 장기 내식성 및 그 현장즉시측정법)

  • Park, Jeong Real;Kim, Kyoo Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.415-423
    • /
    • 2004
  • To investigate the long-term corrosion resistance of an uncoated weathering steel, an important outdoor constructional steel material, skyward surfaces of the weathering steel and a control steel initially exposed to rural and industrial atmospheres for 9 years were electrochemically tested in neutral artificial rain in terms of electrochemical potentials, impedances, and anodic potentiodynamic polarization curves. Their results were then discussed. A quite passive and stable rust layer to the artificial rain was well formed on the skyward surface of the weathering steel exposed to the industrial and rural atmospheres, and its corrosion rate in the artificial rain was measured to be about a low $3{{\mu}m}/y$. Continuous immersion of all the weathered surfaces in the artificial rain revealed the gradual degradation of the weathered corrosion layers on the steel, resulting in a cathodically controlled corrosion of the substrate steel by the electrochemical measurements. Alloy components of the weathering steel were found to retard the degradation of the weathered corrosion layers on the steel in the artificial rain. For better corrosion evaluation of the weathering steel, more electrochemical measurements of surfaces that have been exposed for more than 9 years to more closely simulated atmospheric waters are needed. These measurements are almost non-destructive and can provide online and in situ information on the corrosion rate, the development of corrosion and the conditions of rust layers on any interested surface and at any exposure time of the steel, so they can be effectively applicable to the corrosion evaluation of steel structures such as bridges, towers, and architectures by forming an electrochemical cell on an interested structural surface and by using a portable electrochemical instrument.

The Development and its Application of Diagnostic Technique for Corrosion Defect of U-type Open Rack Vaporizer (개방형 U-type 기화기의 부식손상부 진단기법 개발 및 적용)

  • Jang S. Y.;Lee S. M.;Oh B. T.;Kho Y. T.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.45-50
    • /
    • 2001
  • Open rack vaporizer (ORV) has been used in liquefied natural gas (LNG) receiving terminal in order to vaporize LNG into natural gas (NG) by heat exchange with seawater The U-type ORV which had been operated with seawater for 14 years is one of the important utilities of the gas production and the weld part of tube connected with header_ pipe had experienced many corrosion problems. To elucidate the cause of corrosion at weld part of vaporizer tube, corrosion potentials were compared by parts. This study concerns on the measurement of corrosion pit depth using non-destructive method and the evaluation of stress distribution in an aspect of safety with finite element analysis. In order to confirm the reliability of galvanic corrosion between weld parts and base metal, the measurement of corrosion potential by parts was conducted for 20 minutes in 3.5$\%$(wt.) NaCl solution. Many non-destructive methods were tried to measure the remaining thickness of vaporizer tube at fields. For general corrosion, tangential radiography test was confirmed as an effective method. In case of a fine corrosion pit, the shape of corrosion pit was reproduced using surface replication method. From collected data, stress distributions were quantitatively evaluated with 2-dimensional finite element method and the diagnostic evaluation on internal pressure of the U-type vaporizer could be made.

  • PDF

Crevice Corrosion Evaluation of Cold Sprayed Copper (저온분사코팅구리의 틈새부식 특성 평가)

  • Lee, Min-Soo;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.247-260
    • /
    • 2010
  • The developement of a HLW disposal canister is under way in KAERI using Cold Spray Coating technique. To estimate corrosion behavior of a cold sprayed copper, a creivice corrosion test was conducted at Southwest Research Institute(SWRI) in the United State. For the measurement of repassivation potential needed for crevice corrosion, three methods such as (1) ASTM G61-86 : Cyclic Potentiodynamic Polarization Measurements, (2) Potentiodynamic Polarization plus intermediate Potentiostatic Hold method, and (3) ASTM G192-08 (THE method) : Potentiodynamic- Galvanostatic-Potentiostatic Method, were introduced in this report. In the crevice corrosion test, the occurrence of corrosion at crevice area was optically determined and the repassivation potentials were checked for three kind of copper specimens in a simulated KURT underground water, using a crevice former dictated in ASTM G61-86. The applied electrochemical test techniques were cyclic polarization, potentiostatic polarization, and electrochemical impedance spectroscopy. As a result of crevice corrosion tests, every copper specimens including cold sprayed one did not show any corrosion figure on crevice areas. And the open-cell voltage, at which corrosion reaction initiates, was influenced by the purity of copper, but not their manufacturing method in this experiment. Therefore, it was convinced that there is no crevice corrosion for the cold sprayed copper in KURT underground environment.

A Study on the Development of Solid Reference Electrode and Remote Protection Potential Measuring System (고체기준전극 및 원격전위측정 시스템 개발에 관한 연구)

  • Ryou, Young-don;Kim, Jin-Jun;Kim, Dong-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.38-43
    • /
    • 2015
  • For buried gas pipelines, cathodic protection system shall be installed to protect against corrosion. The surveys of pipe-to-soil potentials for the gas pipelines should be carried out at the test box more than once a year. In urban, the test box is usually located on the driveway, therefore, it is difficult to measure the potentials. That is, traffic control is needed when carrying out the measurements of the potentials on daytime, or measurements of pipe-to-soil potentials at the test box located on the driveway have to be carried out in the late night when the traffic is light. We have developed remote potential monitoring system using the solid reference electrode and the wireless communication technology for the purpose of removing above problems. We have installed the developed solid reference electrodes at a site and monitored the potentials by wireless communication. Measured potential values were transferred to the server in office and analyzed. We have found the pipe-to-soil potentials transferred to the web server make no difference to the potentials measured directly on the site.

Evaluation of corrosion resistance of Co-Cr alloys fabricated with different metal laser sintering systems

  • Tuna, Suleyman Hakan;Karaca, Erhan;Aslan, Ismail;Pekkan, Gurel;Pekmez, Nuran Ozcicek
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.114-123
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the corrosion resistance of the specimens produced by five different commercial metal laser sintering (MLS) systems with their recommended Co-Cr alloy powders. MATERIALS AND METHODS. The MLS machines and the alloy powders used were, ProX 100-ST2724G (St-Pro), Mysint 100-EOS SP2 (SP2-Mys), EOSINT 270-EOS SP2 (SP2-EOS), SLM 100-Starbond CoS (SB-SLM), and MLab Cusing-Remanium® Star (RS-MLab), respectively. Eight specimens from each group were prepared. Open circuit potential (Eocp) and electrochemical impedance spectroscopy (EIS) measurements of polished surfaces of the specimens were conducted in a three-electrode cell using a potentiostat-galvanostat in Fusayama-Meyer artificial saliva (AS). Specimens from each group were immersed in AS and de-ionized water for seven days. Eocp, charge transfer resistance (Rct) values, and released ions (㎍/㎠ × 7d) in different solutions were determined. The specimen surfaces were observed with SEM/EDS. Results were analyzed statistically. RESULTS. Eocp values have shifted to potentials that are more positive over time. Steady-state Eocp values were from high to low as follows, SB-SLM, SP2-Mys, SP2-EOS, RS-MLab, and ST-Pro, respectively. After 60 mins, RS-MLab specimens had the highest Rct value, followed by SP2-Mys, SB-SLM, SP2-EOS, and ST-Pro. In all groups, ion release was higher in AS than that in de-ionized water. CONCLUSION. There were small differences among the corrosion resistances of the Co-Cr alloy specimens produced with MLS systems; meanwhile, the corrosion resistances were quite high for all specimens.