• Title/Summary/Keyword: Corrosion behavior

Search Result 1,274, Processing Time 0.026 seconds

Evaluation of Time-Dependent Chloride Resistance in HPC Containing Fly Ash Cured for 1 Year (1년 양생 조건의 Fly Ash를 혼입한 고성능 콘크리트의 시간의존적 염해저항성 평가)

  • Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.52-59
    • /
    • 2018
  • To control chloride attacks which is a representative deterioration in RC(Reinforced Concrete) structures, many studies have been conducted. Above all, a method using mineral admixture was known to be effective for corrosion protection. In this study, durability test about chloride attacks was carried out for concrete specimens containing FA(Fly Ash)-representative concrete mineral admixture and OPC concrete specimens considering 3 different levels of W/B(Water to Binder). Accelerated chloride diffusion coefficient tests referred to Tang's method, total passed charge tests referred to ASTM C 1202, and compressive strength tests based on KS F 2405 were performed at each target age day. Also, based on previous studies of 28 days, time-parameter which is a key parameter for diffusion behavior is evaluated and its relations with compressive strength at the age of 365 days is evaluated. After the age of 49 days, chloride resistance of FA concrete is much improved than that of OPC concrete, which arose out of stable hydrates due to pozzolan reaction of fly ash. Time-parameter of FA concrete is evaluated to be about 1.5 times larger than that of OPC concrete. Also, time-parameter of FA concrete has a linearly decreasing relation while that of OPC concrete has a linearly increasing relation with compressive strength development.

Oxidation characteristics of solder alloys for the photovoltaic module (태양전지 묘듈용 솔드 합금의 산화 특성)

  • Kim, Hyo Jae;Lee, Young Eun;Lee, Gu;Kang, Gi Hwan;Choi, Byung Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.98-104
    • /
    • 2014
  • Photovoltaic (PV) cell is considered as one of the finest ways to utilize the solar power. A study of improving solar cell's efficiency is important because the lifetime of solar cell is determined by photovoltaic module technology. Therefore, oxidation (and/or corrosion) of solder materials will be one of the primary yield and long-term reliability risk factor. Recently, the development of lead-free solder alloy has been done actively about lead-free solder alloys of the thermodynamic and mechanical properties. However, the oxidation behavior have rarely been investigated In this study, the oxidations of 60 wt% Sn-40 wt% Pb, 62 wt% Sn-36 wt% Pb -2 wt% Ag, 50wt% Sn-48 wt% Bi-2 wt% Ag alloys for the interconnect ribbon after exposure in atmosphere at $100^{\circ}C$ for several times were investigated. The wettability of 62 wt% Sn-36 wt% Pb-2 wt% Ag and 50 wt% Sn-48 wt% Bi-2 wt% Ag solders was also studied to compare with that of 60 wt% Sn-40 wt% Pb alloy. The results howed that the zero cross time and the wetting time of 50 wt% Sn-48 wt% Bi-2 wt% Ag solder were better than other two samples. The surface of tested samples was analyzed by XPS. The XPS result showed that in all samples, SnO grew first and then the mixture of SnO and $SnO_2$ was detected. $SnO_2$ grew predominantly for the long time aging. Moreover XPS depth profile analysis has found surface enrichment of tin oxide.

Effects of Metalized Al-2%Zn Layer on the Corrosion Behavior of Al 5083 Alloy (Al 5083 합금의 부식거동에 미치는 Al-2%Zn 용사 코팅층의 영향)

  • 김용철;김영근;이성민;고영태
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.2-2
    • /
    • 1999
  • 금속재료의 표면 특성을 높이기 위해서 여러 표면처리 방법들이 사용되어져 오고 있다. 그 중 용사법에 의한 코팅방법이 최근의 현저한 기술적인 진보와 새로운 용사재료의 개발 등에 의해 여러 분야에 널리 응흉되고 있다. 일반적으로 이 용사법에 의한 코팅층은 다리, 선박 등의 대형 구조물에 대한 내식성 향상뿐만 아니라 자동차 및 항공기 부품, 핵 반응기 등의 코팅부에 널리 이용되고 였다. 특히 해수분위기에서 주로 사용되는 설비의 내식성을 향상시킬 목적으로 사용되 는 알루마늄 및 아연 합금의 용사 코팅층은 대부분의 경우 건조한 분위기보다는 수분이 많은 수용액 환경 하에서 사용되므로, 사용 환경 중에서 용사피막의 내식성을 조사하는 연구가 요구되고 있다. 사용되는 환경하에서의 침지시험에 의한 방법도 중요하지만, 가속화된 전기화학측정에 의한 방법 또한 이용된다. 열용사법에 의한 코팅층의 전기화학적 특성을 알아보기 위해서 3.5 % NaCI 수용액 내에서 AI 5 5083 모재와 Al-2%Zn 합금의 용사 코팅층 각각에 대한, 그리고 AI 5083 모재 위 AI-2%Zn 용사층이 코팅된 경우에 대한 분극거동과 침지시간에 따른 부식전위 및 분극저항성의 특성변화, 표면의 임피던스특성 변화 등을 측정하였다. 이 결과 모재에 대한 코팅층의 희생양극성올 판단할 수 있고, 모재/코팅 사스템의 분극거동은 혼성전위이론(mixed-potential theory)에 의해 결정되었다. 용사 코팅층이 박리되어 모재가 일부 드러난 경우를 모사한 시험편올 제작하고, 시험편 표면의 각 위치에 따라 부식전위 분포를 측정하였다. 그리고 측정 데이터를 기초로 표면의 상태변화를 모사하여 용사코팅에 의한 표면에서의 방식전위분포를 시율레이션하였다. 이와 같은 표면에서의 방식전위분포 해석을 통하여, 코팅층의 희생양극성에 의한 모재의 방식범위를 판단할 수 있다.의 비저 항을 갖는 철 박막에서도 99.9% 순도의 철을 타켓으로 하여 증착된 막은 일반 저탄소 강을 타켓으로 하여 증착된 막보다 훨씬 낮은 부식속도를 보였다.TEX>$He/O_2/Ar/N_2$의 gas를 사용 한 atmospheric pressure plasma cleaning 과 $Ar/O_2$의 gas를 사용한 ICP cleaning에서 이 차전자방출계수(SEEC)가 약 1.5~2.5배 증가된 것을 알 수 있었다. 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorne

  • PDF

Prediction of Ultimate Strength and Strain of Concrete Columns Retrofitted by FRP Using Adaptive Neuro-Fuzzy Inference System (FRP로 보강된 콘크리트 부재의 압축응력-변형률 예측을 위한 뉴로퍼지모델의 적용)

  • Park, Tae-Won;Na, Ung-Jin;Kwon, Sung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.19-27
    • /
    • 2010
  • Aging and severe environments are major causes of damage in reinforced concrete (RC) structures such as buildings and bridges. Deterioration such as concrete cracks, corrosion of steel, and deformation of structural members can significantly degrade the structural performance and safety. Therefore, effective and easy-to-use methods are desired for repairing and strengthening such concrete structures. Various methods for strengthening and rehabilitation of RC structures have been developed in the past several decades. Recently, FRP composite materials have emerged as a cost-effective alternative to the conventional materials for repairing, strengthening, and retrofitting deteriorating/deficient concrete structures, by externally bonding FRP laminates to concrete structural members. The main purpose of this study is to investigate the effectiveness of adaptive neuro-fuzzy inference system (ANFIS) in predicting behavior of circular type concrete column retrofitted with FRP. To construct training and testing dataset, experiment results for the specimens which have different retrofit profile are used. Retrofit ratio, strength of existing concrete, thickness, number of layer, stiffness, ultimate strength of fiber and size of specimens are selected as input parameters to predict strength, strain, and stiffness of post-yielding modulus. These proposed ANFIS models show reliable increased accuracy in predicting constitutive properties of concrete retrofitted by FRP, compared to the constitutive models suggested by other researchers.

Flexural Behaviors of GFRP Rebars Reinforced Concrete Beam under Accelerated Aging Environments (GFRP Rebar 보강 콘크리트 보의 급속노화환경에서의 휨 거동에 관한 연구)

  • Park, Yeon-Ho;Choi, Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.137-144
    • /
    • 2013
  • The use of fiber-reinforced polymer (FRP) reinforcing bars in concrete structures has been increased as an alternative of steel reinforcement which has shown greater vulnerability to corrosion problem. However, the long-term performance of concrete members with FRP reinforcement is still questioned in comparison to the used of steel reinforcement. This study presents the results of an experimental study on the long-term behaviors of GFRP (glass fiber reinforced polymer) bar reinforced concrete beams after exposed to accelerated aging in an environmental chamber with temperature of $46^{\circ}C$ ($115^{\circ}F$) and 80% of relative humidity up to 300 days. The objectives of this research was to compare strength degradation and change of ductility between GFRP reinforced concrete beams and steel reinforcement beams after accelerated aging. Two types (wrapped and sand-coated surface) of GFRP bars and steel were reinforced. in concrete beams. Test results show that the failure modes of GFRP bar reinforced concrete beams are very similar with traditional RC beams, and the change of load-carrying capacity of steel reinforcing concrete beam is greater than that of GFRP bar reinforcing concrete beam under the accelerated aging. Test result also shows that the use of GFRP reinforcing in concrete could be introduced more brittle failure than that of steel reinforcing for practical application. The deformability factor up to compression failures indicates no significant variation before and after exposure of accelerated aging.

Analysis of Thermal Shock Behavior of Cladding with SiCf/SiC Composite Protective Films (SiCf/SiC 복합체 보호막 금속피복관의 열충격 거동 분석)

  • Lee, Dong-Hee;Kim, Weon-Ju;Park, Ji-Yeon;Kim, Dae-Jong;Lee, Hyeon-Geon;Park, Kwang-Heon
    • Composites Research
    • /
    • v.29 no.1
    • /
    • pp.40-44
    • /
    • 2016
  • Nuclear fuel cladding used in a nuclear power plant must possess superior oxidation resistance in the coolant atmosphere of high temperature/high pressure. However, as was the case for the critical LOCA (loss-of-coolant accident) accident that took place in the Fukushima disaster, there is a risk of hydrogen explosion when the nuclear fuel cladding and steam reacts dramatically to cause a rapid high-temperature oxidation accompanied by generation of a huge amount of hydrogen. Hence, an active search is ongoing for an alternative material to be used for manufacturing of nuclear fuel cladding. Studies are currently aimed at improving the safety of this cladding. In particular, ceramic-based nuclear fuel cladding, such as SiC, is receiving much attention due to the excellent radiation resistance, high strength, chemical durability against oxidation and corrosion, and excellent thermal conduction of ceramics. In the present study, cladding with $SiC_f/SiC$ protective films was fabricated using a process that forms a matrix phase by polymer impregnation of polycarbosilane (PCS) after filament-winding the SiC fiber onto an existing Zry-4 cladding tube. It is analyzed the oxidation and microstructure of the metal cladding with $SiC_f/SiC$ composite protective films using a drop tube furnace for thermal shock test.

The Effects of Pretreatment and Surfactants on CNT and Permalloy Composite Electroplating (전처리와 분산제가 CNT-permalloy 복합전기도금에 미치는 영향 연구)

  • Um, Ho-Kyung;Lee, Heung-Yeol;Yim, Tai-Hong;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.63-68
    • /
    • 2010
  • CNT and permalloy composite plating was investigated. CNTs were pretreated prior to electroplating to disassemble the tangled CNT lumps. The ball milling as a physical pretreatment and the acid treatment as a chemical pretreatment were used. 10M nitric acid and 10 M sulfuric acid were used for the chemical pretreatment. Sulfuric acid was more effective than nitric acid to disassemble CNT lumps. To disperse CNT in the solution, surfactants were used. SDS, Triton X-100 and PAA were used for this purpose. More CNTs were incorporated in permalloy coating when PAA was used as a surfactant. The surface morphologies were observed with FESEM after electroplating CNT and permalloy. The current densities were varied from 10 to $80\;mA/cm^2$ and the concentration of PAA was fixed at 2 g/L. The optimum current density without surface cracks was $20\;mA/cm^2$. The crystallinity of the deposit was analyzed with XRD and the surface hardness was analyzed with Vicker's hardness tester. The corrosion behavior was analyzed with polarization plot. The physical properties of permalloy were not improved with CNT composite plating.

Problems of Metallic Dental Instruments for Dental Use (치과에서 사용되는 금속치과기구의 임상적용시 문제)

  • 최한철
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.15-15
    • /
    • 2003
  • 치과재료에 사용되는 금속재료는 주로 스테인리스강, 타이타늄, Ni-Ti, Co-Cr등과 같은 특수합금이 주로 사용되고 있다. 이들 재료는 치과 보철물과 교정재료 및 충전재료로 주로 사용되고 있으며 그 외 치과에서 사용되는 기기나 기구에도 많이 활용되고 있다. 특히 치과 보철물을 사용하여 치료를 원하는 환자가 최근에 급격히 증가하면서 임플란트 고정체와 나사 등을 이용한 치료법의 연구와 개발이 필요하게 되어 세계적으로 연구와 투자가 활발히 진행되고 있다. 그러나 재료의 설계나 합금의 설계 및 제품의 설계상의 문제로 인하여 생체조직과 결합하는데 많은 문제점이 임상적으로 발생되고 있다. 즉 임플란트 표면의 생체적합성부여, 고정체와의 결합시 파절이나 풀림현상, 골에 고정체로 사용하는 나사의 강도와 내마모성문제 등이 개선되어야 할 문제점으로 남아있다. 또한 총의치에 사용되는 자석 어태치먼트의erosion-corrosion문제, 교정선의 탄성 과 마모저항문제 등은 앞으로 계속적인 연구를 행하여야할 과제로 남아있다. 또한 국소의치에서 사용되는 frame은 정밀주조법을 통하여 제조하며 주조상의 결함 등으로 인한 클라스프의 파절 문제점이 발생되고 있다. 따라서 본 연구에서는 치과재료로 사용되는 임플란트 고정체, 나사, 교정용 선등의 문제점을 고찰하고, 지금까지 이루어진 연구를 중심으로 최적의 개선 조건을 찾고자하였다. 최근첨단소재 및 금속재료를 사용하여 치과재료 합금을 설계할 수 있는 연구가 활발히 진행된다면 수입에 의존하고 있는 고가의 치과재료를 값이 싼 고성능의 제품으로 대체할 수 있는 효과가 클 것으로 생각된다.>$\rho$$\sub$0/=1.8 %. As t$\sub$Co/ increases, a transition from the regime of co-existence of superparamagnetic and ferromagnetic behaviors to ferromagnetic behavior was observed. Tunneling barrier called "decay length for tunneling" for the films having the thickness of Co layer from 1.4 to 1.6 nm was measured to be ranged from 0.004 to 0.021 ${\AA}$$\^$-1/.문에 기업간 관계를 연구하는 측면에서는 탐험적 연구성격이 강하다. 더 나아가 본 산업의 주된 연구가 질적이고 기업내부만을 연구했던 것에 비교하면 시초적이라고 할 수 있다. 또한 관계마케팅, CRM 등의 이론적 배경이 되고 있는 신뢰와 결속의 중요성이 재확인하는 결과도 의의라고 할 수 있다. 그리고 신뢰는 양사 간의 상호관계에서 조성될 수 있는 특성을 가진 반면, 결속은 계약관계 초기단계에서 성문화하고 규정화 할 수 있는 변수의 성격이 강하다고 할 수가 있다. 본 연구는 복잡한 기업간 관계를 지나치게 협력적 측면에서만 규명했기 때문에 많은 측면을 간과할 가능성이 있다. 또한 방법론적으로 일방향의 시각만을 고려했고, 횡단적 조사를 통하고 국내의 한 서비스제공업체와 관련이 있는 컨텐츠 공급파트너

  • PDF

Evaluation of Chloride Diffusion Characteristics in Concrete with Fly Ash Cured for 2 Years (2년 양생된 Fly Ash 콘크리트의 염화물 확산 특성 평가)

  • Yoon, Yong-Sik;Hwang, Sang-Hyeon;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • When RC(Reinforced Concrete) structures are exposed to harsh environment, deterioration phenomenon occurs, and the corrosion in rebar due to chloride intrusion is known as representative deterioration, so called chloride attack. In this paper, chloride resistance performance of 2 years aged concrete is evaluated considering 3 levels of water to binder ratio(0.37, 0.42, and 0.47) and 2 levels of substitution ratio of fly ash(0% and 30%). Accelerated chloride diffusion coefficient tests referred to Tang's method, total passed charge tests referred to ASTM C 1202, and compressive strength tests referred to KS F 2405 are performed. With adaptation of the previous test results and the results from this study, time-dependent chloride diffusion characteristics are analyzed for each concrete. The FA(Fly Ash) concrete has higher chloride resistance performance than OPC(Ordinary Portland Cement) concrete. According to the evaluation standard of ASTM C 1202, the FA concrete has "Moderate" grade after 49 days while OPC concrete does "Moderate" grade after 365 days. As the results of time-parameter for chloride diffusion, OPC concrete and FA concrete show the decreasing behavior of time-parameters with increasing water to binder ratio. Also, FA concrete has 1.57~2.74 times of time-parameter than OPC concrete. That's cause is thought that the time-parameter indicates the gradient of decreasing of diffusion coefficient. FA concrete has higher time-parameters than OPC concrete by pozzolanic reaction of FA.

The Case Study of Design on Steel Pipe Sheet Pile for Earth Retaining Wall on Deep Excavation (대심도 지반굴착을 위한 벽강관말뚝 흙막이공법의 설계 사례 연구)

  • Byung-Il Kim;Jong-Ku Lee;Kyoung-Tae Kim;Kang-Han Hong;Sang-Jae Han
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 2023
  • In this study, the results of the elasto-plastic beam analysis, finite element analysis and optimization design of the steel pipe sheet pile applied as an earth retaining wall under the deep excavation were presented. Through this study, it was found that the high-strength and sea resistant steel pipe has high allowable stress, excellent structural properties, favorable corrosion, and high utilization as an earth retaining wall, and the C-Y type joint has significantly improved the tensile strength and stiffness compared to the traditional P-P type. In addition, it was investigated that even if the leak or defect of the wall occurs during construction, it has the advantage of being able to be repaired reliably through welding and overlapping. In the case of steel pipe wall, they were evaluated as the best in views of the deep excavation due to the large allowable bending stress and deformation flexibility for the same horizontal displacement than CIP or slurry wall. Elasto-plastic and finite element analysis were conducted in consideration of ground excavation under large-scale earth pressure (uneven pressure), and the results were compared with each other. Quantitative maximum value were found to be similar between the two methods for each item, such as excavation behavior, wall displacement, or member force, and both analysis method were found to be applicable in design for steel pipe sheet pile wall. Finally, it was found that economical design was possible when determining the thinnest filling method with concrete rather than the thickest hollow shape in the same diameter, and the depth (the embedded length through normality evaluation) without rapidly change in displacement and member force.