• Title/Summary/Keyword: Corrosion Potential 부식전위

Search Result 182, Processing Time 0.04 seconds

Hydrodynamic Effects on Corrosion and Passivation of Copper in Borate Buffer Solution (Borate 완충용액에서 구리의 부식과 부동화에 미치는 대류 영향)

  • Chon, Jung-Kyoon;Kim, Youn-Kyoo
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.14-19
    • /
    • 2007
  • The corrosion and passivation of copper was investigated with the copper rotating disk electrode(Cu-RDE) in borate buffer solution. It has been observed with the mixed potential theory that the corrosion potential for the rotation rate increase under the convective diffusion condition was increased. It was suggested that the chemical intermediates and product 13. the copper oxidation were $Cu(OH)_{ads},\;{Cu(OH)_2}^-,\;Cu_2O,\;Cu(OH)_2,\;and\;CuO$.

Study on the Characteristics of Crevice Corrosion for STS304 Austenitic Stainless Steel(I) (오스테나이트계 스테인리스강의 틈부식 특성에 관한연구(I))

  • 임우조
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.66-72
    • /
    • 2000
  • In these days, with development of industry, the use of machines and structures like ships, airplanes, bridges, power plants, and structure for construction has increased and these machines and structures are used in various corrosive environment. Especially, in case of STS 304, which is material for every kind of machine and chemical plant, it makes many problems related with corrosion and as a result of this, there are happening tremendous economic loss. Therefor, in this study, the test for polarization characteristics was carried out to study characteristics of crevice corrosion of STS 304 which is austenitic stainless steel, in NaCl environment.The main results obtained are as follows :1) Part of crevice is corroded, neighboring outside surface of crevice is passivation. 2) In polarization behavior, corrosion potential of STS 304 become more noble as the concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5% that of STS 3.4 become less noble. 3) The current density under corrosion potential was high drained as concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, the current density was low drained.

  • PDF

The Effect of Shot Peening on the Corrosion and Fatigue Crack to SAE5155 Steel (SAE 5155강에서 쇼트피닝이 부식과 피로균열특성에 미치는 영향)

  • Park, Kyeong-Dong;Shin, Yung-Jin;Kim, Dong-Ug
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.731-739
    • /
    • 2006
  • Corrosion and lassitude are very important in the metal construction Currently, the shot peening is used much for removing the defect on the surface, improving the fatigue strength on surface. In this study. the influence of shot peening to the corrosion property were investigated in 3.5% NaCl, 10% HNO3 + 3% HF. 6% FeC13. The immersion test was performed on two kind of specimen(Removed corrosion product. RCP and Continuous immersed specimen: CIS). The immersion periods was 3600hours. Corrosion potential. weight loss, and fatigue crack growth characteristics were investigated. The result, shot peening in corrosion potential showed stable potential. Also, shot peening displayed small Weight loss than un peening. And Fatigue crack resistivity of shot peening in corrosion solution's fatigue crack appeared greatly than un peening.

A Study on the Corrosion Rehavior and Mechanical Property by SSRTTest of Welding Part of RE36 Steel for Marine Structure (해양구조물 RE36강의 용접부 부식거동 및 SSRT법에 의한 기계적 특성에 관한 연구)

  • 김종성;김진경;김종호;이명훈;김영식;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.460-469
    • /
    • 2000
  • A study on the corrosion behavior of RE36 steel for marine structure was investigated with parameters such as micro-Vickers hardness, corrosion potential and corrosion current density measurement of weld metal(WM), base metal (BM) and heat affected zone(HAZ), Al anode generating current and Al anode weight loss quantity in case of cathodic protection. And we carried out slow strain rate test(SSRT) in order to research mechanical properties such as stress at maximum load, percent strain, time to fracture and strain to failure ratio etc and to find out limiting cathodic polarization potential for hydrogen embrittlement with applied cathodic polarization potential. Hardness of HAZ part was the highest among those three parts and also galvanic corrosion susceptibility was the highest in HAZ part among those three parts due to the lowest corrosion potential than other parts. However corrosion current density was the highest in WM part among those three parts. And the optimum cathodic polarization potential showing the best mechanical properties obtained by SSRT method with applied constant cathodic potential was from - 770mV to - 875mV(SCE). However it is suggested that limiting cathodic polarization potential indicating hydrogen embrittlement on the mechanical properties was under - 900mV(SCE).

  • PDF

Crevice Corrosion Evaluation of Cold Sprayed Copper (저온분사코팅구리의 틈새부식 특성 평가)

  • Lee, Min-Soo;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.247-260
    • /
    • 2010
  • The developement of a HLW disposal canister is under way in KAERI using Cold Spray Coating technique. To estimate corrosion behavior of a cold sprayed copper, a creivice corrosion test was conducted at Southwest Research Institute(SWRI) in the United State. For the measurement of repassivation potential needed for crevice corrosion, three methods such as (1) ASTM G61-86 : Cyclic Potentiodynamic Polarization Measurements, (2) Potentiodynamic Polarization plus intermediate Potentiostatic Hold method, and (3) ASTM G192-08 (THE method) : Potentiodynamic- Galvanostatic-Potentiostatic Method, were introduced in this report. In the crevice corrosion test, the occurrence of corrosion at crevice area was optically determined and the repassivation potentials were checked for three kind of copper specimens in a simulated KURT underground water, using a crevice former dictated in ASTM G61-86. The applied electrochemical test techniques were cyclic polarization, potentiostatic polarization, and electrochemical impedance spectroscopy. As a result of crevice corrosion tests, every copper specimens including cold sprayed one did not show any corrosion figure on crevice areas. And the open-cell voltage, at which corrosion reaction initiates, was influenced by the purity of copper, but not their manufacturing method in this experiment. Therefore, it was convinced that there is no crevice corrosion for the cold sprayed copper in KURT underground environment.

Electrochemical and Sludge Dissolution Behavior During a Copper Removal Process for Chemical Cleaning on the Secondary Side of Nuclear Steam Generators (원전 증기발생기 2차측 화학세정을 위한 제동공정중의 전기화학적 거동 및 슬러지용해 거동)

  • Hur, Do-Haeng;Chung, Han-Sub;Kim, Uh-Chul;Chae, Sung-Ki;Park, Kwang-Kyoo;Kim, Jae-Pyong
    • Nuclear Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.154-162
    • /
    • 1992
  • Two major goals for chemical cleaning on the secondary side of nuclear steam generators are to remove sludge effectively and to minimize corrosion of base metals. In this work, electrochemical and sludge dissolution behaviors have been investigated in order to find out which parameters are critical and important during a copper removal process for chemical cleaning and to evaluate safety aspects and effectiveness of two major copper removal processes developed commercially in foreign countries. Hydrogen peroxide is vert effective for the process to use EDTA, NH$_4$OH and EDA at 38$^{\circ}C$ to control the potential of copper in a potential range sood for copper sludge removal. Corrosion rates for carbon steel SA 285 Gr.C and Alloy 600 are very small during this process if it is controlled properly. However, the corrosion rate of SA 285 Gr.C will be increased greatly if its corrosion potential is maintained below -450mV. The process to use EDA and ammonium carbonate is effective at 6$0^{\circ}C$ to dissolve copper sludge if the corrosion potential of copper can be controlled above -200mV. However, it is very difficult to raise the corrosion potential of copper to this range by air blowing and stirring.

  • PDF

A Study on Stress Corrosion Behaviors in Welded Zone of the API 5L-X65 Steel for Natural Gas Transmission (천연가스 수송용 API 5L-X65강 용접부의 부식거동에 관한 연구)

  • JO SANG-KEUN;SONG HAN-SEOP;KONG YOO-SIK;KIM YUONG-DAI
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.401-407
    • /
    • 2004
  • This study is on the constant-current stress corrosion test related to the load stress in welded zone and non-welded zone of high tensile strength steel for natural gas transmission. The surface corrosion pattern of the welded zone of API 5L-X65 specimens for natural gas transmission showed global corrosion and narrow pitting, and the pitting was increased by increasing the load stress. Initially, the average relative electrode potential and the average relative current of the high tensile strength steel for natural gas transmission specimens was decreased suddenly, and the average relative electrode potential was higher and the average relative current was lower in welded zone than base metal. and the average relative electrode potential was decreased by increasing the load stress, and the average relative current was somewhat increased by increasing the load stress. The corrosion rate was less in welded zone than base metal, and the corrosion rate was decreased by increasing the load stress.

  • PDF

Study on Environment Corrosion Characteristics of Automobile Component Materials (차량용 부품재료의 환경부식 특성 연구)

  • Park, Keyoung-Dong;Shin, Yeong-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.3
    • /
    • pp.86-91
    • /
    • 2006
  • The compressive residual stress, which is inducing by shot peening process, has the effect of increasing the intrinsic fatigue strength of surface and therefore would be beneficial in reducing the probability of fatigue damage. However, it was not known that the effect of shot peening in corrosion environment. In this study, the influence of shot peening and corrosion condition for corrosion property were investigated on immersed in 3.5% NaCl, 10% HNO3 + 3% HF, 6% $FeCl_3$. The immersion test was performed with two kind of specimen. The immersion periods was performed 150days. Corrosion potential, weight loss were investigated from experimental results. From test results, the effect of shot peening on the corrosion characteristics was evaluated.

  • PDF

Fundamental Study on Developing Embedded Mini-Sensor for Nondestructive Diagnosis Corrosion of Rebar (비파괴 철근 부식 진단을 위한 매립형 미니센서 개발에 관한 기초적 연구)

  • Joh, Sung-Hyung;Lim, Young-Chul;Ismail, Mohamed;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.179-187
    • /
    • 2010
  • Corrosion of rebar embedded reinforced concrete is the main cause of collapse and degradation of reinforced concrete structure. Degradation occurs in reinforced concrete structures from corrosion caused by the Chloride that the damage other than the severe degradation of the structure in terms of maintenance and construction when the huge expense required and deciding terms is hard. Therefore, early detection of rebar corrosion is important for efficient maintenance and repairing and planning. Meanwhile, how to evaluate the corrosion of the non-destructive measurements have been used a lot. In particular CM-II (corrosion meter) is used to measurement the natural potential, polarization resistance and the resistivity of the concrete, but has some disadvantages. Embedded mini-sensor has been developed in order to overcome these disadvantages. So Measurement corrosion for using the mini-sensor compares with the measured results CM-II (corrosion meter), the developed mini-sensor verify the validity.