• Title/Summary/Keyword: Corrosion Pattern

Search Result 115, Processing Time 0.021 seconds

Effect of Corrosion Characteristics in Relation to Loaded Stress in the Welded Zone of A5083-H116 Aluminum Alloy (A5083-H116 알루미늄 합금재 용접부의 부하응력에 따른 부식특성의 영향)

  • Jo, S.K.;Kong, Y.S.;Kim, Y.D.
    • Journal of Power System Engineering
    • /
    • v.8 no.3
    • /
    • pp.44-51
    • /
    • 2004
  • Effect of corrosion characteristics in relation to loaded stress in the welded zone of A5083-H116 aluminum alloy, in the seawater was studied. The corrosion experiment was performed for 120 hours on the specimens in the natural seawater tank with four steps of the loaded stress. The corrosion crack, corrosion rate, electrode potential, current, and corrosion pattern, etc. were examined for the specimens with the elapse of the immersion time. The main result derived from this study is the crack growth length is increased with the increasing loaded stress. The electrode potential and the corrosion current are decreased rapidly in the early stage of the corrosion, and then decreased gradually and stabilized eventually with the elapse of the immersion time. The test condition of the longer crack growth tends to show the higher corrosion rate. Corrosion pattern of the welded zone indicates that the depth and width of the pitting become increasing with the increasing loaded stress.

  • PDF

Effect of corrosion pattern on the ductility of tensile reinforcement extracted from a 26-year-old corroded beam

  • Zhu, Wenjun;Francois, Raoul
    • Advances in concrete construction
    • /
    • v.1 no.2
    • /
    • pp.121-136
    • /
    • 2013
  • Tension tests were carried out to investigate the effect of the corrosion pattern on the ductility of tension bars extracted from a 26-year-old corroded reinforced concrete beam. The tensile behavior of corroded bars with different corrosion patterns was examined carefully, as were two non-corroded bars extracted from a 26-year-old control beam. The results show that corrosion leads to an increase in the ratio of the ultimate strength over the yield strength, but reduces the ultimate strain at maximum force of the reinforcement. Both the corrosion pattern and the corrosion intensity play an important role in the ductile properties. The asymmetrical distribution of the corrosion around the surface is a decisive factor, which can influence the ultimate strain at maximum force more seriously.

Effects of Torsional Stress on the Corrosion Characteristics in the Rotor Assembly of Marine Diesel Engine Supercharger (선박용 디젤엔진 과급기 로터 접합체의 부식특성에 미치는 비틀림응력의 영향)

  • Jo, S.K.;Kong, Y.S.;Kim, Y.D.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.50-56
    • /
    • 2005
  • The corrosion experiment was performed for 120 hours on the specimens in the natural seawater tank with four steps of the loaded torsional stress. The surface corrosion pattern of SCM440 area was showed global corrosion and narrow pitting, that was cause by galvanic corrosion between friction welded IN713LC and SCM440. But corrosion does not proceeded from IN713LC area. Initially, the average relative electrode potential and corrosion current were decreased suddenly, by and large, it was stabilized gradually tend to decreasing with the elapse of the immersion time. The corrosion rate was decreased by increasing the load stress, but 200 MPa specimen was showed most large value.

  • PDF

The Effects of pH on the Corrosion Characteristics in Dissimilar Friction Welded Zone of IN713LC-SCM440 (IN713LC-SCM440 이종재 마찰용접부의 부식특성에 미치는 pH의 영향)

  • JO SANG-KEUN;KONG YU-SIK;KIM YOUNG-DAE
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.2 s.63
    • /
    • pp.53-59
    • /
    • 2005
  • The effect of pH on the corrosion characteristics in the dissimilar friction welded zone of IN713LC-SCM440 in the loaded torsional stress was studied. The corrosion experiment was performed for 120 hours on the specimens with five steps of pH. The surface corrosion pattern of the SCM440 area showed global corrosion and narrow pitting, which was caused by galvanic corrosion between friction welded IN713LC and SCM440, but corrosion did not proceeded from the IN713LC area. The average relative electrode potential gradually tends to decrease with the elapse of the immersion time in the acidity area. The average corrosion current also gradually tend to decrease The corrosion rate showed a larger value when the average relative electrode potential was higher and the average relative current was lower. The corrosion rate showed a larger value when the average relative electrode potential was higher in the acidity area, and it showed large when the average relative electrode potential was lower in the alkalinity area.

Impact of geometric pattern corrosion on limit failure pressure of buried gas pipelines

  • Hassani, Nemat;Kolbadi, S. Mohammad S.;Shiravand, Mahmud Reza;Golafshani, Jafar H.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.5
    • /
    • pp.795-802
    • /
    • 2016
  • Gas pipelines are types of structures that are highly susceptible to corrosion. Sometimes, the pipes are subjected to a thinning of the wall thickness at the inside or outside wall due to erosion/corrosion. Therefore, it is important to evaluate the strength of the pipes undergoing corrosion to maintain the integrity of the piping systems. The main purpose of this study is to understand failure aspects caused by degradation of metal due to corrosion through. The ASME standard offers a relationship for the yielding pressure of the corroded pipes which was compared with the finite element results. The results demonstrate to obtain accurate results, the ASME relationship is unreliable. Moreover, pitting corrosion must be considered critical more than of other types.

On Corrosion Behaviors in Welded Zone of API 5L-X65 Steel for Natural Gas Transmission (천연가스 수송용 API 5L-X65강 용접부의 부식거동에 관한 연구)

  • JO SANG-KEUN;SONG HAN-SEOP;KONG Yu-SIK;KIM YOUNG-DAI
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.50-56
    • /
    • 2004
  • This study is on the constant-current stress corrosion test, related to the load stress, in both the welded and non-welded zones of high tensile strength steel that is used for natural gas transmission. The surface corrosion pattern of the welded zone of API 5L-X65 specimens for natural gas transmission showed general corrosion and narrow pitting, and the pitting was increased with load stress. Initially, the average relative electrode potential and the average relative current of the high tensile strength steel, used for natural gas transmission specimens, were decreased rapidly, and the average relative electrode potential was higher and the average relative current was lower in welded zone, compared to base metal. The average relative electrode potential was decreased with load stress, and the average relative current was somewhat increased by increasing the load stress. The corrosion rate was less in welded zone, compared to base metal, and the corrosion rate was decreased by increasing the load stress.

A Study on Stress Corrosion Behaviors in Welded Zone of the API 5L-X65 Steel for Natural Gas Transmission (천연가스 수송용 API 5L-X65강 용접부의 부식거동에 관한 연구)

  • JO SANG-KEUN;SONG HAN-SEOP;KONG YOO-SIK;KIM YUONG-DAI
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.401-407
    • /
    • 2004
  • This study is on the constant-current stress corrosion test related to the load stress in welded zone and non-welded zone of high tensile strength steel for natural gas transmission. The surface corrosion pattern of the welded zone of API 5L-X65 specimens for natural gas transmission showed global corrosion and narrow pitting, and the pitting was increased by increasing the load stress. Initially, the average relative electrode potential and the average relative current of the high tensile strength steel for natural gas transmission specimens was decreased suddenly, and the average relative electrode potential was higher and the average relative current was lower in welded zone than base metal. and the average relative electrode potential was decreased by increasing the load stress, and the average relative current was somewhat increased by increasing the load stress. The corrosion rate was less in welded zone than base metal, and the corrosion rate was decreased by increasing the load stress.

  • PDF

A Study on the Post-Weld Heat Treatment Effect Affecting Corrosion Behavior and Mechanical Property of Welding Part of RE36 Steel for Marine Structure (해양구조물용 RE36강 용접부의 부식거동 및 기계적 특성에 미치는 용접후 열처리 효과에 관한 연구)

  • 김성종;문경만
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.65-74
    • /
    • 2001
  • A study on the corrosion behavior in case of As-welded and PWHT temperature 55$0^{\circ}C$ of welding part of RE36 steel for marine structure was investigated with parameters such as micro-Vickers hardness, corrosion potential measurement of weld metal(WM), base metal(BM) and heat affected zone(HAZ), both Al anode generating current and Al anode weight loss quantity under sacrificial anode cathodic protection conditions. And also we carried out slow strain rate test(SSRT) in order to research both limiting cathodic polarization potential for hydrogen embrittlement and optimum cathodic protection potential as well as mechanical properties by post-weld heat treatment(PWHT) effect. Hardness of HAZ was the highest among three parts(WM, BM and HAZ) and the highest galvanic corrosion susceptibility was HAZ. And the optimum cathodic polarization potential showing the best mechanical properties by SSRT method was from -770mV to -875mV(SCE). In analysis of SEM fractography, applied cathodic potential from -770mV to -875mV(SCE) it appeared dimple pattern with ductile fracture while it showed transgranular pattern (Q. C : quasicleavage) under -900mV(SCE). However it is suggested that limiting cathodic polarization potential indicating hydrogen embrittlement was under -900mV(SCE).

  • PDF

Noticeable localized corrosion of solid boric acid on 304 stainless steel

  • Xinzhu Li;Wen Sun;Guiling Ning
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3616-3625
    • /
    • 2024
  • With the aim to determine the potential corrosion effects of solid boric acid (BA) on light water reactors or other BA-involved equipment, the corrosion behaviors of solid BA on 304 stainless steel (SS) at different temperatures were investigated. Upon comparing the corrosion behaviors of solid BA at different temperatures, significant localized corrosion was observed on 304 SS surfaces at 150 ℃ following 90-day. This localized corrosion exhibited a characteristic pattern of scattered corrosion craters including B-containing Cr-rich oxides. These oxides were found to originate within micro-cracks, gradually evolving into scar-like protrusions within the craters. The proposed corrosion mechanisms entail the interactions between solid BA and chromium oxides/hydroxides, leading to the formation of B-containing Cr-rich oxides. Our findings offer insights into potential corrosion incidents and protective strategies for industries dealing with solid BA.

Acoustic emission technique to identify stress corrosion cracking damage

  • Soltangharaei, V.;Hill, J.W.;Ai, Li;Anay, R.;Greer, B.;Bayat, Mahmoud;Ziehl, P.
    • Structural Engineering and Mechanics
    • /
    • v.75 no.6
    • /
    • pp.723-736
    • /
    • 2020
  • In this paper, acoustic emission (AE) and pattern recognition are utilized to identify the AE signal signatures caused by propagation of stress corrosion cracking (SCC) in a 304 stainless steel plate. The surface of the plate is under almost uniform tensile stress at a notch. A corrosive environment is provided by exposing the notch to a solution of 1% Potassium Tetrathionate by weight. The Global b-value indicated an occurrence of the first visible crack and damage stages during the SCC. Furthermore, a method based on linear regression has been developed for damage identification using AE data.