• 제목/요약/키워드: Corrosion Monitoring

검색결과 259건 처리시간 0.022초

부식촉진시험에 의한 콘크리트 내의 철근의 부식 모니터링에 관한 실험적 연구 (An Experimental Study on the Corrosion Monitoring of Reinforcing Steel in Concrete by the Accelerated Corrosion Test)

  • 배수호;정영수;김진영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.543-548
    • /
    • 2001
  • The corrosion monitoring methods of reinforcing steel in concrete are the various methods such as half cell potential method, galvanic current method, resistivity method, polarization resistance method, AC impedance method and etc. In this study, the corrosion monitoring methods of reinforcing steel in concrete were investigated for the test specimens using corrosion inhibitors, zinc-mortar, zinc-plate, respectively. For this purpose, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles(140 days) of wetting($65^{\circ}C$, 90% R.H.) and drying period(15$^{\circ}C$ , 65% R.H.) for the test specimens. As a result, it can be concluded from the test that half cell potential and galvanic current method as monitoring techniques for corrosion were found to be relatively reliable and easily usable method in the field.

  • PDF

TRS를 이용한 해양구조물의 원격 실시간 부식감시 및 방식 제어시스템 개발 (The Development of The Remote Real-Time Corrosion Monitoring and Control System Using by TRS for Maritime Metallic Structures)

  • 배정효;하태현;이현구;김대경;최상봉;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 D
    • /
    • pp.657-659
    • /
    • 2000
  • The importance of total management for maritime structures (Ports, Piers, docks. marine bridges, marine roads, submarine pipelines, etc.) is more and more increasing in these days. Especially, in spite of the marine structures are exposed at the various corrosion circumstances, there are not only a standard of Cathodic Protection System but also knowledge of importance for necessity of corrosion monitoring. Therefore, this paper presents the results of development for the Remote Real-Time Corrosion Monitoring and Control System Using by TRS on Maritime Metallic Structures which can be prevents a big accident by corrosion.

  • PDF

고효율 전기 방식용 정류기를 이용한 유류탱크의 원 방식 제어 시스템 개발 (The Development of Remote Corrosion Monitoring and Control System for Oil Tank by using the High Efficiency CP Rectifier)

  • 배정효;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.249-252
    • /
    • 2002
  • Recently, the advanced countries are using the corrosion monitoring system in a chemical plant and an oil tank in order to protect the corrosion because it leads to a big accident, pollution of soil. and lose of money Generally. the owners of the facilities adopt CP(Cathodic Protection) systems to protect the corrosion also. However, a CP system for oil tank was not considered in Korea Moreover they didn't adopted a corrosion monitoring system. In this paper, we have been developed not only the remote automatic corrosion monitoring but also the remote corrosion control system using the high efficiency CP rectifier. This results should be used to operate the CP system effectively and economically. And also it will be possible to extend the expectation life of the Oil tanks.

  • PDF

무선 원격 부식모니터링용 TRS 단말기 (The TRS Terminal for Wireless Remote Corrosion Monitoring System)

  • 하태현;배정효;이현구;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

부식감시 및 방식을 위한 웹기반 예측시스템에 관한 연구 (Study on the Web-based Prediction System for Corrosion Monitoring and Anti-corrosion)

  • 박형근;김선엽
    • 한국산학기술학회논문지
    • /
    • 제13권2호
    • /
    • pp.784-789
    • /
    • 2012
  • 본 논문에서는 방식 대상물 주변에 설치되어 있는 다수의 양극과 기준전극을 감시하고, 상황에 맞게 고정전위 및 분극 방법을 자동으로 적용할 수 있는 시스템을 개발하였다. 특히, 개발된 시스템은 방식 대상물의 전 부분이 균일하게 방식이 이루어지도록 자동 조정하는 기능을 가진 원격 전기방식 자동제어 장치, 부식전위를 검출하는 기능을 수행하는 부식감시 장치 그리고 이들 장치의 부식 및 방식 관련 데이터에 대해 실시간 감시 및 제어와 예측 기능을 수행하는 웹기반 운영프로그램으로 구성하였으며, 이 시스템을 이용하여 산화현상에 의한 부식을 방지함으로써 방식 대상물의 수명을 최대화할 수 있다.

Performance indicator of the atmospheric corrosion monitor and concrete corrosion sensors in Kuwait field research station

  • Husain, A.;Al-Bahar, Suad Kh.;Salam, Safaa A. Abdul
    • Smart Structures and Systems
    • /
    • 제17권6호
    • /
    • pp.981-994
    • /
    • 2016
  • Two field research stations based upon atmospheric corrosivity monitoring combined with reinforced concrete corrosion rate sensors have been established in Kuwait. This was established for the purpose of remote monitoring of building materials performance for concrete under Kuwait atmospheric environment. The two field research sites for concrete have been based upon an outcome from a research investigation intended for monitoring the atmospheric corrosivity from weathering station distributed in eight areas, and in different regions in Kuwait. Data on corrosivity measurements are essential for the development of specification of an optimized corrosion resistance system for reinforced concrete manufactured products. This study aims to optimize, characterize, and utilize long-term concrete structural health monitoring through on line corrosion measurement and to determine the feasibility and viability of the integrated anode ladder corrosion sensors embedded in concrete. The atmospheric corrosivity categories supported with GSM remote data acquisition system from eight corrosion monitoring stations at different regions in Kuwait are being classified according to standard ISO 9223. The two nominated field sites where based upon time of wetness and bimetallic corrosion rate from atmospheric data where metals and rebar's concrete are likely to be used. Eight concrete blocks with embeddable anodic ladder corrosion sensors were placed in the atmospheric zone adjacent to the sea shore at KISR site. The anodic ladder corrosion rate sensors for concrete were installed to provide an early warning system on prediction of the corrosion propagation and on developing new insights on the long-term durability performance and repair of concrete structures to lower labor cost. The results show the atmospheric corrosivity data of the environment and the feasibility of data retrieval of the corrosion potential of concrete from the embeddable sets of anodic ladder corrosion sensors.

Monitoring Cathodic Shielding and Corrosion under Disbonded Coatings

  • Varela, F.;Tan, M. YJ;Hinton, B.;Forsyth, M.
    • Corrosion Science and Technology
    • /
    • 제16권3호
    • /
    • pp.109-114
    • /
    • 2017
  • Monitoring of corrosion is in most cases based on simulation of environmental conditions on a large and complex structure such as a buried pipeline using a small probe, and the measurement of thermodynamics and kinetics of corrosion processes occurring on the probe surface. This paper presents a hybrid corrosion monitoring probe designed for simulating deteriorating conditions wrought by disbonded coatings and for measuring current densities and distribution of such densities on a simulated pipeline surface. The concept of the probe was experimentally evaluated using immersion tests under cathodic protection (CP) in high resistivity aqueous solution. Underneath the disbonded area, anodic currents and cathodic currents were carefully measured. Anodic current densities were used to calculate metal loss according to Faraday's law. Calculated corrosion patterns were compared with corrosion damage observed at the surface of the probe after a series of stringent tests. The capability of the probe to measure anodic current densities under CP, without requiring interruption, was demonstrated in high resistivity aqueous solution. The pattern of calculated metal loss correlated well with corrosion products distribution observed at the array surface. Working principles of the probe are explained in terms of electrochemistry.

인공신경망과 대기부식환경 모니터링 데이터를 이용한 항공기 세척주기 결정 알고리즘 (Algorithm for Determining Aircraft Washing Intervals Using Atmospheric Corrosion Monitoring of Airbase Data and an Artificial Neural Network)

  • 권혁준;이두열
    • Corrosion Science and Technology
    • /
    • 제22권5호
    • /
    • pp.377-386
    • /
    • 2023
  • Aircraft washing is performed periodically for corrosion control. Currently, the aircraft washing interval is qualitatively set according to the geographical conditions of each base. We developed a washing interval determination algorithm based on atmospheric corrosion environment monitoring data at the Republic of Korea Air Force (ROKAF) bases and United States Air Force (USAF) bases to determine the optimal interval. The main factors of the washing interval decision algorithm were identified through hierarchical clustering, sensitivity analysis, and analysis of variance, and criteria were derived. To improve the classification accuracy, we developed a washing interval decision model based on an artificial neural network (ANN). The ANN model was calibrated and validated using the atmospheric corrosion environment monitoring data and washing intervals of the USAF bases. The new algorithm returned a three-level washing interval, depending on the corrosion rate of steel and the results of the ANN model. A new base-specific aircraft washing interval was proposed by inputting the atmospheric corrosion environment monitoring results of the ROKAF bases into the algorithm.

An Overview of New Progresses in Understanding Pipeline Corrosion

  • Tan, M. YJ;Varela, F.;Huo, Y.;Gupta, R.;Abreu, D.;Mahdavi, F.;Hinton, B.;Forsyth, M.
    • Corrosion Science and Technology
    • /
    • 제15권6호
    • /
    • pp.271-280
    • /
    • 2016
  • An approach to achieving the ambitious goal of cost effectively extending the safe operation life of energy pipeline to 100 years is the application of health monitoring and life prediction tools that are able to provide both long-term remnant pipeline life prediction and in-situ pipeline condition monitoring. A critical step is the enhancement of technological capabilities that are required for understanding and quantifying the effects of key factors influencing buried steel pipeline corrosion and environmentally assisted materials degradation, and the development of condition monitoring technologies that are able to provide in-situ monitoring and site-specific warning of pipeline damage. This paper provides an overview of our current research aimed at developing new sensors and electrochemical cells for monitoring, categorising and quantifying the level and nature of external pipeline and coating damages under the combined effects of various inter-related variables and processes such as localised corrosion, coating cracking and disbondment, cathodic shielding, transit loss of cathodic protection.

Monitoring corrosion of reinforced concrete beams in a chloride containing environment under different loading levels

  • Wei, Aifang;Wang, Ying;Tan, Mike Y.J.
    • Structural Monitoring and Maintenance
    • /
    • 제2권3호
    • /
    • pp.253-267
    • /
    • 2015
  • Corrosion has significant adverse effects on the durability of reinforced concrete (RC) structures, especially those exposed to a marine environment and subjected to mechanical stress, such as bridges, jetties, piers and wharfs. Previous studies have been carried out to investigate the corrosion behaviour of steel rebar in various concrete structures, however, few studies have focused on the corrosion monitoring of RC structures that are subjected to both mechanical stress and environmental effects. This paper presents an exploratory study on the development of corrosion monitoring and detection techniques for RC structures under the combined effects of external loadings and corrosive media. Four RC beams were tested in 3% NaCl solutions under different levels of point loads. Corrosion processes occurring on steel bars under different loads and under alternative wetting - drying cycle conditions were monitored. Electrochemical and microscopic methods were utilised to measure corrosion potentials of steel bars; to monitor galvanic currents flowing between different steel bars in each beam; and to observe corrosion patterns, respectively. The results indicated that steel corrosion in RC beams was affected by local stress. The point load caused the increase of galvanic currents, corrosion rates and corrosion areas. Pitting corrosion was found to be the main form of corrosion on the surface of the steel bars for most of the beams, probably due to the local concentration of chloride ions. In addition, visual observation of the samples confirmed that the localities of corrosion were related to the locations of steel bars in beams. It was also demonstrated that electrochemical devices are useful for the detection of RC beam corrosion.