• Title/Summary/Keyword: Corrosion Level

Search Result 348, Processing Time 0.032 seconds

Study on the Decontamination of Primary Cooling Pump in HANARO (하나로 1차 냉각펌프 제염에 대한 고찰)

  • An Jung-Sug;Lee Kyung-Ho;Kim Kwang-Dug;Park Young-Chul
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.21-29
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Recently, ten years after the initial operation of the HANARO, one of the two primary cooling pumps was decontaminated for overhaul maintenance in 2004. Before decontamination exposure doserate and surface contamination level of primary cooling pump measured at 4 points. After final decontamination exposure doserate and surface contamination level of primary cooling pump remeasured by same method done before. It is easy to decontaminate the out side exposed surfaces of the pump, but it is difficult to approach the inside surface due to double volute installed in the casing. Therefore, a new decontamination facility has been developed to solve this problem. A concentrated de-contaminant (DX-300) is rotated in the closed pump casing by the impeller actuated by a temporary motor. Nuclide particles are removed by the emulsification effect of the de-contaminant and the surface contaminants are chemically removed from the pump by the corrosion and dissolution effect. The inside surfaces of the primary cooling pump have been decontaminated by using the facility. As results, the contamination level of the inside surfaces was maintained below the surface contamination limit.

  • PDF

Recognition of damage pattern and evolution in CFRP cable with a novel bonding anchorage by acoustic emission

  • Wu, Jingyu;Lan, Chengming;Xian, Guijun;Li, Hui
    • Smart Structures and Systems
    • /
    • v.21 no.4
    • /
    • pp.421-433
    • /
    • 2018
  • Carbon fiber reinforced polymer (CFRP) cable has good mechanical properties and corrosion resistance. However, the anchorage of CFRP cable is a big issue due to the anisotropic property of CFRP material. In this article, a high-efficient bonding anchorage with novel configuration is developed for CFRP cables. The acoustic emission (AE) technique is employed to evaluate the performance of anchorage in the fatigue test and post-fatigue ultimate bearing capacity test. The obtained AE signals are analyzed by using a combination of unsupervised K-means clustering and supervised K-nearest neighbor classification (K-NN) for quantifying the performance of the anchorage and damage evolutions. An AE feature vector (including both frequency and energy characteristics of AE signal) for clustering analysis is proposed and the under-sampling approaches are employed to regress the influence of the imbalanced classes distribution in AE dataset for improving clustering quality. The results indicate that four classes exist in AE dataset, which correspond to the shear deformation of potting compound, matrix cracking, fiber-matrix debonding and fiber fracture in CFRP bars. The AE intensity released by the deformation of potting compound is very slight during the whole loading process and no obvious premature damage observed in CFRP bars aroused by anchorage effect at relative low stress level, indicating the anchorage configuration in this study is reliable.

Performance Evaluation of Sintered Metal Filter in LILW Vitrification Facility (중.저준위 방사성폐기물 유리화설비에서 금속필터 적용성평가)

  • Park, Seung-Chul;Kim, Byong-Ryol;Hwang, Tae-Won
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.146-153
    • /
    • 2006
  • A performance test of the stainless steel based sintered metal filter was conducted on the low and intermediate level radioactive waste (LILW) vitrification process. The applicability of the metal filter was based on the test results as well. The baseline pressure drop of the metal filter was evaluated similar to the ceramic filter. During the test, when the flow rate of off-gas was $110Nm^{3}/h$, the total baseline pressure drop was shown as $92mmH_{2}O$. The total pressure drop was attributed to the filter media and the residual dust layer and the value of each was $25mmH_{2}O\;and\;67mmH_{2}O$ respectively. The SEM-EDS spectrum and micrograph of the metal filter specimen showed, no corrosion and no physical damage both at the skin membrane and at the support layer. And most of the baseline pressure drop was caused by the deposition of dust on the surface of the membrane. In conclusion, even though the filter exposure time was short at the test, the performance of the stainless steel based metal filter was acceptable for the treatment of LILW vitrification process.

Mechanical Characteristics of GF/recycled PET Thermoplastic Composites with Chopped Fiber According to Cross Section (단면형상에 따른 GF/rPET 열가소성 복합재료의 물리적 특성 연구)

  • Kim, Ji-hye;Lee, Eun-soo;Kim, Myung-soon;Sim, Jee-hyun
    • Textile Coloration and Finishing
    • /
    • v.29 no.4
    • /
    • pp.239-246
    • /
    • 2017
  • Recently fiber-reinforced thermoplastic composites have attracted great interest from industry and study because they offer unique properties such as high strength, modulus, impact resistance, corrosion resistance, and damping reduction which are difficult to obtain in single-component materials. The demand for plastics is steadily increasing not only in household goods, packaging materials, but also in high-performance engineering plastic and recycling. As a result, the technology of recycling plastic is also attracting attention. In particular, many paper have studied recycling systems based on recycled thermoplastics. In this paper, properties of Glass Fiber Reinforced Thermoplastic(GFRTP) materials were evaluated using recycled PET for injection molding bicycle frame. The effect on thermal and mechanical properties of recycled PET reinforced glass chop fiber according to fiber cross section and fiber content ratio were studied. And it was compared void volume and torque energy by glass fiber cross section, which is round section and flat section. Mechanical characteristics of resulting in GF/rPET has been increased by increasing fiber contents, than above a certain level did not longer increased. And mechanical properties of flat glass fiber reinforced rPET with low void volume were most excellent.

ILD CMP 공정에서 실리콘 산화막의 기계적 성질이 Scratch 발생에 미치는 영향

  • Jo, Byeong-Jun;Gwon, Tae-Yeong;Kim, Hyeok-Min;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.23-23
    • /
    • 2011
  • Chemical-Mechanical Planarization (CMP) 공정이란 화학적 반응 및 기계적인 힘이 복합적으로 작용하여 표면을 평탄화하는 공정이다. 이러한 CMP 공정은 반도체 산업에서 회로의 고집적화와 다층구조를 형성하기 위하여 도입되었으며 반도체 제조를 위한 필수공정으로 그 중요성이 강조되고 있다. 특히 최근에는 Inter-Level Dielectric (ILD)의 형성과 Shallow Trench Isolation (STI) 공정에서실리콘 산화막을 평탄화하기 위한 CMP 공정에 대해 연구가 활발히 이루어지고 있다. 그러나 CMP 공정 후 scratch, pitting corrosion, contamination 등의 Defect가 발생하는 문제점이 존재한다. 이 중에서도 scratch는 기계적, 열적 스트레스에 의해 생성된 패드의 잔해, 슬러리의 잔유물, 응집된 입자 등에 의해 표면에 형성된다. 반도체 공정에서는 다양한 종류의 실리콘 산화막이 사용되고 gks이러한 실리콘 산화막들은 종류에 따라 경도가 다르다. 따라서 실리콘 산화막의 경도에 따른 CMP 공정 및 이로 인한 Scratch 발생에 관한 연구가 필요하다고 할 수 있다. 본 연구에서는 scratch 형성의 거동을 알아보기 위하여 boronphoshposilicate glass (BPSG), plasma enhanced chemical vapor deposition (PECVD) tetraethylorthosilicate (TEOS), high density plasma (HDP) oxide의 3가지 실리콘 산화막의 기계적 성질 및 이에 따른 CMP 공정에 대한 평가를 실시하였다. CMP 공정 후 효율적인 scratch 평가를 위해 브러시를 이용하여 1차 세정을 실시하였으며 습식세정방법(SC-1, DHF)으로 마무리 하였다. Scratch 개수는 Particle counter (Surfscan6200, KLA Tencor, USA)로 측정하였고, 광학현미경을 이용하여 형태를 관찰하였다. Scratch 평가를 위한 CMP 공정은 실험에 사용된 3가지 종류의 실리콘 산화막들의 경도가 서로 다르기 때문에 동등한 실험조건 설정을 위해 동일한 연마량이 관찰되는 조건에서 실시하였다. 실험결과 scratch 종류는 그 형태에 따라 chatter/line/rolling type의 3가지로 분류되었다 BPSG가 다른 종류의 실리콘 산화막에 비해 많은 수에 scratch가 관찰되었으며 line type이 많은 비율을 차지한다는 것을 확인하였다. 또한 CMP 공정에서 압력이 증가함에 따라 chatter type scratch의 길이는 짧아지고 폭이 넓어지는 것을 확인하였다. 본 연구를 통해 실리콘 산화막의 경도에 따른 scratch 형성 원리를 파악하였다.

  • PDF

Muscular Condition Monitoring System Using Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서를 이용한 근육 상태 감시 시스템)

  • Kim, Heon-Young;Lee, Jin-Hyuk;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.5
    • /
    • pp.362-368
    • /
    • 2014
  • Fiber optic sensors (FOS) have advantages such as electromagnetic interference (EMI) immunity, corrosion resistance and multiplexing capability. For these reasons, they are widely used in various condition monitoring systems (CMS). This study investigated a muscular condition monitoring system using fiber optic sensors (FOS). Generally, sensors for monitoring the condition of the human body are based on electro-magnetic devices. However, such an electrical system has several weaknesses, including the potential for electro-magnetic interference and distortion. Fiber Bragg grating (FBG) sensors overcome these weaknesses, along with simplifying the devices and increasing user convenience. To measure the level of muscle contraction and relaxation, which indicates the musle condition, a belt-shaped FBG sensor module that makes it possible to monitor the movement of muscles in the radial and circumferential directions was fabricated in this study. In addition, a uniaxial tensile test was carried out in order to evaluate the applicability of this FBG sensor module. Based on the experimental results, a relationship was observed between the tensile stress and Bragg wavelength of the FBG sensors, which revealed the possibility of fabricating a muscular condition monitoring system based on FBG sensors.

Investigation of Seasonal Characteristics of Contaminants and Hydrochemical Factors in an Aquifer for Application of In Situ Reactive Zone Technology (원위치 반응존 공법 적용을 위한 대수층내 오염물질 및 환경영향인자의 계절 특성 평가)

  • Ahn, Jun-Young;Kim, Cheolyong;Kim, Tae Yoo;Jun, Seong-Chun;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.192-203
    • /
    • 2016
  • A field investigation was conducted on an aquifer contaminated with trichloroethylene (TCE) for application of in situ reactive zone treatment using nanosized zero-valent iron (NZVI). The aquifer was an unconfined aquifer with a mean hydraulic conductivity of $5.14{\times}10^{-4}cm/sec$, which would be favorable for NZVI injection. Seasonal monitoring of TCE concentration revealed a presence of non-aqueous phase liquid form of TCE near IW (injection well). The hydrochemical data characterized the site groundwater to be a $Ca-HCO_3$ type. The average value of Langelier Saturation Index of the groundwater was -1.33, which implied that the site was favorable for corrosion of NZVI. Dissolved oxygen (DO) concentration varied between 2.5~11.5 mg/L, which indicated that DO would greatly compete with TCE as an electron acceptor. The hydrogeological and hydrochemical characterization reveals that the time around November would be appropriate for NZVI injection when water level and temperature are relatively high and DO concentration is low.

Optimal Parameter Selection by Health Monitoring of Gas Turbine Engines using Gas Path Analysis (GPA를 이용한 가스터빈 엔진의 성능진단에 의한 최적 계측변수 선정에 관한 연구)

  • ;Riti Singh
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.24-33
    • /
    • 1999
  • For performance prediction and diagnostics of gas turbine engines, linear and non-linear gas path analysis are applied. In order to find optimal instrument parameters to detect the physical faults such as (outing, erosion and corrosion, non-linear gas path analysis is used. A typical industrial gas turbine engine, TB5000, is used to study the effect of physical faults on engine performance. Through comparison of RMS error between linear and non-linear gas path analysis, the optimal instrument parameters can be defined. As a result, it is found that the linear GPA has the level of error introduced by the assumption of the linear mode: can be of the same order of magnitude as the fault being soughtwhile the non-linear GPA can be solved the non-linear relationships between dependent and independent parameters using an iterative method such as the Newton-Raphson method with sufficient accuracy.

  • PDF

The Bisphenol A: A Modulator of Pregnancy in Rats

  • Kim, Pan-Gyi;Lee, Na-Rae;Hwang, Seong-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.4
    • /
    • pp.27-34
    • /
    • 2003
  • Bisphenol A is used in the manufacture of epoxy, polycarbonate, and corrosion-resistant unsaturated polyester-styrene resins required for food packaging materials in industrial processing. Some reports indicated the possibility of harmful effects on rats. In this study was used a method for the determination of bisphenol A in blood according to the OSHA High Performance Liquid Chromatography (HPLC) guideline. The method involved blood extraction using methylene chloride. And it was evaluated developmental and teratogenic effects in pregnant rats and second generation. The results obtained were as follows. There was a significant increase in the body weights and treated groups F1 female in liver, spleen, kidney, but according to dose-response. F1 female rat's relative body weight and absolute body weight are not different. There was a significant increase liver, spleen, kidney organ weight and reproductive organ weight epididymis, prostate gland in F1 male rats. There was a proestrous in pregnant rat, group 200 $\mu\textrm{g}$/kg, 2000 $\mu\textrm{g}$/kg, 20,000 $\mu\textrm{g}$/kg. The effect on rat treated with bisphenol A decrease organ weight and reproductive organ weight. Identification and quantitation were performed with using HPLC C18 column and using at retention time 5.5 min. The results of the detection of bisphenol A were at 20,000 $\mu\textrm{g}$/kg in average 1 $\mu\textrm{g}$/ml, 200 $\mu\textrm{g}$/kg average in 0.9 $\mu\textrm{g}$/ml blood samples. From those results, it could be concluded that the effects of pregnant rat and second generation(F1) by bisphenol A treatment during lactational period were estrogenic and bisphenol A was remained in serum at low level.

Fabrication of Mechanical fatigue flawed Specimen and Evaluation of Flaw Size (기계적 피로결함 시험편 제조 및 결함 크기 평가)

  • Hong, Jae-Keun;Kim, Woo-Sung;Son, Young-Ho;Park, Ban-Uk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Mechanical or thermal fatigue crack and intergranular stress corrosion cracking could be occured in the in-service nuclear power plant and mechanical fatigue crack was selected to study in this paper. Specimen was designed to produce mechanical fatigue flaw under tensile stress. The number of cycles and the level of stress were controlled to obtain the desired flaw roughness. After the accurate physical measurement of the flaw size and location, fracture surface was seal-welded in place to ensure the designed location and site. The remaining weld groove was then filled by using gas-tungsten are welding(GTAW) and flux-cored arc welding(FCAW). Results of radio graphic and ultrasonic testing showed that fatigue cracks were consistent with the designed size and location in the final specimens.