• 제목/요약/키워드: Corrosion Fatigue

검색결과 418건 처리시간 0.029초

STS304 열화재의 부식및 부 식피로특성 (Corrosion and Corrosion Fatigue Characteristics of Artificially Sensitized STS 304)

  • 한지원;배동호
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Stainless steel is useful material for various industrial facilities such as the nuclear and steam power plant and the heavy chemical industry due to its good corrosion resistance and mechanical properties. However, it has also a large problem that is sensitized in the welding process and its corrosion resistance and mechanical properties decreases by sensitization. Thus, corrosion and corrosion fatigue characteristics of artificially sensitized austenitic STS304 were investigated through the EPR test and corrosion fatigue test. Obtained results are as follows: 1) According to the sensitizing period increase, Cr deficiency layer is linearly expanded. 2) Degree of sensitization(Ia/Ir) proportionally increased with sensitizing period. However, after 4hrs, it showed constant value. 3) Cr-carbide($Cr_{23}C_6$) in the grain boundary increased as sensitizing period increases until six hours. 4) corrosion fatigue strength of sensitized STS304 were remarkably reduced compare to non-sensitized ones.

철도차량 구조재료의 부식 및 피로 특성 연구 (A Study on the Corrosion and Fatigue of Structural Materials for Rolling Stock)

  • 장세기;김용기;구병춘
    • 한국철도학회논문집
    • /
    • 제8권4호
    • /
    • pp.299-307
    • /
    • 2005
  • In general, structural integrity of rolling stock structures should last more than 25 years. During the lifetime corrosive degradation occurs. For structural design and diagnosis, quantitative relationship between corrosive degradation and variation of mechanical properties such as tensile strength and fatigue strength is needed. In this study, first of all we established the atmospheric corrosion test procedure. At regular intervals using specimens of SM490A and SS400 on the atmospheric corrosion test bed, we carried out tensile and fatigue tests. The fatigue strength decreases as the atmospheric corrosion period increases. In addition we studied the effect of post-weld heat treatment on the tensile and fatigue behaviour and performed electrochemical corrosion tests.

Turbine Blade재료의 부식민감성과 부식피로특성에 관한 연구 (A Study on the Corrosion Susceptibility and Corrosion Fatigue Characteristics on the Material of Turbine Blade)

  • 조선영;김철한;류승우;김효진;배동호
    • 대한기계학회논문집A
    • /
    • 제24권3호
    • /
    • pp.603-612
    • /
    • 2000
  • Corrosion characteristics on the 12Cr alloy steel of turbine blade was electro-chemically investigated in 3.5wt% NaCI and 12.7wt% Na2S04 solution, respectively. Electro-chemical polarization test, Huey test and Oxalic acid etching test were previously conducted to estimate corrosion susceptibility of the material. And, using the horizontal corrosion fatigue tester, corrosion fatigue characteristics of 12Cr alloy steel in distilled water, 3.5wt% NaCI solution, and 12.7wt%(1M) Na2S04 solution were also fracture-mechanically estimated and compared their results. Parameter considered was room temperature, 60'C and 90'C. Corrosion fatigue crack length was measured by DC potential difference method.Obtained results are as follows,1) 12Cr alloy steel showed high corrosion rate in 3.5wt% NaCI solution and Na2S04 solution at high tempratue.2) Intergranular corrosion sensitivity of 12 Cr alloy was smaller than austenitic stainless steel.3) Corrosion fatigue crack growth rate in 3.5wt% NaCI and 12.7wt%(IM) Na2S04 solution is entirely higher than in the distilled water, and also increased with the temperature increase.

기계구조용강 SM55C의 부식피로강도에 미치는 산성안개 분위기의 영향 (Effects of Acid Fog Environment on the Corrosion Fatigue Strength of Structural Steel SM55C)

  • 김진학;김민건
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.181-187
    • /
    • 2000
  • Fatigue tests under acid fog environment were carried out to investigate the effect of acid fog on the corrosion fatigue strength of SM55C in comparison with distilled water. Main results obtained are as follows. The fatigue strength of SM55C under acid fog environment are remarkably decreased as compared with that of distilled water specimen. The corrosive effect of acid fog on fatigue strength are more serious under low stress amplitude level than under high stress amplitude level, and this leads to continuous reduction of fatigue strength. Under acid fog environment in early stage of crack growth. because the corrosive components dissolve the crack face offensively. the unstable fracture surface appears. But, the stable corrosion precipitation and products layer are formed on the fracture surface in accordance with the time pass.

  • PDF

3% NaCl 수용액중에서 복합조직강의 부식피로거동에 미치는 제2상 속도변화의 영향 (Effect of the change of second phase hardness on corrosion fatigue behavior of dual phase steel in 3% nacl solution)

  • 오세욱;김웅집
    • 한국해양공학회지
    • /
    • 제6권2호
    • /
    • pp.85-93
    • /
    • 1992
  • The only hardness of 2nd phase of martensite in dual phase steel which was composed of the martensite and ferrite was changed. Fatigue test was conducted by cantilever type of self-made rotated bending fatigue testing machine. The corrosion fatigue fracture behaviors of dual phase steel were investigated in 3% NaCl solution at $N_f$ = $1.5\times$$10^5$ $N_f$=1.0 $\times$ $10^6$ cycles. The fatigue strength was increased with increasing the hardness of 2nd phase. The size and number of corrsion pits were influenced by the 2nd phase hardness and pits remain constant in size just after they were transited into cracks. The life of crack initiation was effected by stress level. The shape of relation of $\Delta$K and da/dn has smaller scattering in it in 3% NaCl solution than that in air. The higher the 2nd phase hardness is, the higher the corrosion fatigue life becomes. Corrosion fatigue fracture behavior was effected by mechanics in case of $N_f$=1.5$\times$10$^5$$N_f$=1.5$\times$10$^6$ cycles.

  • PDF

고장력강의 부식피로에 미치는 용액온도의 영향에 관한 연구 (Study on effect of solution temperature on corrosion fatigue of high strength steel)

  • 유헌일
    • 오토저널
    • /
    • 제8권1호
    • /
    • pp.40-51
    • /
    • 1986
  • A study has been made of the corrosion fatigue of high strength low alloy steel in 3.5% NaCl solution under tension stress for solution temperature being 25.deg. C, 55.deg. C and 85 .deg. C. The main results obtained are as follows; 1) The corrosion fatigue crack growth rate curve could be divided into the First Region, the Second Region and the Third Region. 2) The corrosion fatigue crack growth rates in the First Region and the Second Region were Arrhenius temperature-dependent in this test range. The apparent activation energies for the corrosion fatigue cack growth rate were found to be 2000cal/mol in the First Region and 3700 cal/mol in the Second Region. 3) Hematite (Fe$_{2}$O$_{3}$) as the hexahedral crystal and magnetite (Fe$_{3}$O$_{4}$) as the octahedral crystal were observed in the corrosion products on the corrosion fatigue fracture surface at 85.deg. C and the anode fusion seem to be generated in the crack tip region at high temperature. 4) The complex environment effect ratio which was defined by the ratio of fatigue crack growth rate in corrosion environment to that in air might be considered not only a criterion estimating the effect of environment quantitatively but also an important parameter in the selection of the design stress for the fail safe design. The complex environment effect was not greater than ten in this test.

  • PDF

부식의 영향을 받는 강교 부재의 피로 취약도 평가 (Fatigue Vulnerability Evaluation of Steel Bridge Members Affected by Corrosion)

  • 김동조;김효진;이형철;이상호
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.67-70
    • /
    • 2007
  • A methodology to evaluate fatigue vulnerability of steel bridge members affected by corrosion and truck traffic variation is proposed. A fatigue limit state function including corrosion and traffic variation effects is established to make the criterion whether the steel bridge member is damaged by fatigue. Corrosion effects are expressed as increase of the average corrosion depth, and the traffic variation effects are modeled as the accumulated number of stress cycles. Reliability analysis is carried out by Monte-Carlo simulation method for the fatigue limit state function. The methodology Proposed is verified by comparing reference study and applying for the steel bridge in service.

  • PDF

일반구조용 압연강재의 부식피로균열전파거동에 미치는 시험편 두께의 영향 (Effect of Specimen Thickness to Corrosion Fatigue Crack Propagation Behavior of Structure Rolled Steel)

  • 조약래
    • 수산해양기술연구
    • /
    • 제28권3호
    • /
    • pp.286-294
    • /
    • 1992
  • In this paper, the corrosion fatigue crack propagation behavior of structure rolled steel (SWS 41C) was investigated by changing the thickness, and this experiment was done by the three point bending corrosion fatigue tester. The main results obtained are as follows: 1) As the thickness of specimen becomes thicker, the corrosion sensitivity to initial stage crack becomes some sensitive, and that the fatigue life becomes more sensitive. 2) The crack growth rate to initial stage crack (da/dN) was retarded as the thickness of specimen becomes thicker. But after initial stage crack, as the thickness of specimen is more thicker, da/dN is more rapid. 3) As the corrosion fatigue crack length grows, the accelerative factor of thick specimen (t=12mm) is more higher than that of thin specimen (t=6mm). 4) As the corrosion fatigue crack length grows, the corroson potential of both thick specimen and thin specimen becomes more less noble potential, however thick specimen (t=12mm) tends to more less noble potential than that of thin specimen(t=6mm).

  • PDF

가스저장탱크의 부식피로균열 특성에 관한 연구 (Study on the Characteristics of Corrosion Fatigue Crack for Gas Storage Tanks)

  • 임우조;신종대
    • 수산해양기술연구
    • /
    • 제34권1호
    • /
    • pp.30-36
    • /
    • 1998
  • Recently, with rapid increase of gas demand, there occurs much interest their security of safety in the gas storage tanks and pressure vessels etc. In order to solve the problems, the occurrence of corrosion fatigue crack and the propagation behavior must be investigated. Especially the occurrence of corrosion fatigue crack and the propagation behavior in the part which has concentrated stress or defects, must be studied more carefully. In this paper, the high-tensile steel of SPV 50 which is much used for building the LPG storage tanks was tested by the use of a plane bending corrosion fatigue tester under the various marine environments and in the air. These experiments were done to investigate the corrosion fatigue crack propagation behavior, the variation of aspect ratio for part through crack and electro-chemical characteristics of the metal. The main results obtained are as follows ; 1. Comparing the same surface crack length with the crack depth, the crack depth toward the thickness of specimen in air propagated faster than that in corrosion environment. 2. The aspect variation of the half elliptical crack can be estimated as following equation; b/a=i-jb/t where a : surface crack length, b : crack depth, t : specimen thickness, i,j : experimental constants but the slope j is decreased as specific resistance decreases. 3. As the specific resistance of corrosion environment decrease or the corrosion fatigue crack propagates, the corrosion potential become less noble.

  • PDF

Corrosion Fatigue Characteristics in the Weld of Multi-Pass Welded A106 Gr B Steel Pipe

  • Bae, Dong-Ho;Kim, Chul-Han
    • Journal of Mechanical Science and Technology
    • /
    • 제18권1호
    • /
    • pp.114-121
    • /
    • 2004
  • In order to investigate the corrosion fatigue characteristics in the weld of multi-pass welded A 106 Gr B steel pipe, corrosion fatigue tests were performed under the various stress ratios and 3.5 wt% NaCl solution at room temperature. The corrosion fatigue characteristic curves were represented using crack closure concept. The obtained results are as follows : when the load frequency is 1.0 Hz, the crack opening point is transited in the region of $K_{max}$=20∼32 MPaㆍ $m^{1}$2/. In the low stress intensity factor range, the crack opening point is higher than that in air. However, in the high stress intensity factor range, it is lower than that in air. In the cases of 0.1 Hz and 0.01 Hz, the crack opening point gradually decreases to $K_{min}$ with $K_{max}$ increase.rease.