• Title/Summary/Keyword: Corrosion Degradation

Search Result 384, Processing Time 0.032 seconds

Advanced Cathodic Protection Modeling Associated with Coating Degradation Conditions

  • Im, Gwan-Jin;Kim, Ki-Joon;Lee, Myung-Hoon
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.177-183
    • /
    • 2009
  • There are two effective methods in use to protect ship ballast tank against corrosion. One is paint coating and the other cathodic protection(CP). The conventional cathodic protection design has mainly relied on the expert's experience. During the last two decades computer modeling has been significantly developed as an advanced design technology for cathoidic protection systems not only for ships, but also for offshore structures. However the present computer modeling of cathodic protection systems have some limitations simulating corrosion in the ballast tank with a deteriorated coating. In this study, "coating breakdown factor" considering coating degradation states with time has been attempted to improve the cathodic protection modeling using the data from literatures.

A Study on the Atmospheric Corrosion and Fatigue of Rolling Stock Structures (철도차량 구조물의 대기부식 및 피로에 관한 연구)

  • Goo Byeong-Choon;Kim Jai-Hoon;Jang Se-Ky
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.421-426
    • /
    • 2005
  • In general, structural integrity of rolling stock structures should last more than 25 years. During the lifetime corrosive degradation occurs. For structural design and diagnosis, quantitative relationship between corrosive degradation and variation of mechanical properties such as tensile strength and fatigue strength is needed. In this study, first of all we established the atmospheric corrosion test procedure. At regular intervals using specimens of SM490A and SS400 on the atmospheric corrosion test bed, we carried out tensile and fatigue tests. The fatigue strength decreases as the atmospheric corrosion period increases. And we studied the effect of post-weld heat treatment on the tensile and fatigue behaviour.

  • PDF

Chloride Diffusion Properties of Concrete with Corrosion Inhibitor (방청제를 함유한 콘크리트의 염소 이온 확산 특성)

  • 구현본;이광명;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.694-699
    • /
    • 2000
  • Recently, the degradation of reinforced concrete structures due to physical and chemical attack has been a major issue in construction engineering. One of the main causes of degradation of concrete structures can be ascribed to chloride-induced corrosion, i.e., the rapid penetration of chloride ions into concrete. To estimate durability of reinforced concrete structures exposed to marine environment, many different kinds of accelerated tests to evaluate the concrete diffusivity were proposed. In this study, present test methods are reviewed and a proper test method for concrete is selected. The diffusion coefficients of concrete with corrosion inhibitor are measured using the proposed method, and then, measured values are compared to those of concrete without corrosion inhibitor. It is found from experimental results that diffusion coefficient re decreased with curing ages.

  • PDF

A Literature Study on the Ozone Degradation of Concrete Structures in Water Treatment Facilities (수처리 시설 콘크리트 구조물의 오존 열화에 관한 문헌적 연구)

  • Park, Jin-Ho;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.177-178
    • /
    • 2015
  • Recently, Advanced water treatment facilities with Ozone are being introduced owing to domestic water pollution. However, waterproofing/corrosion prevention construction method of concrete structure for existing advanced water treatment makes waterproofing/corrosion prevention materials and concrete deteriorated because of strong oxidation of ozone. it causes increase of maintenance cost and water quality degradation. Therefore, in this study, it will figure out problems of waterproofing/corrosion prevention construction method being applied to through existing studies.

  • PDF

OVERVIEW OF FRETTING CORROSION IN ELECTRICAL CONNECTORS

  • PARK Y. W.;JUNG J. P.;LEE K. Y.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.75-82
    • /
    • 2006
  • Fretting corrosion widely known as a degradation mechanism refers to the combination of fretting wear and corrosion such as oxidation. This paper critically reviews the works published previously on fretting corrosion of electrical connectors. Various experimental approaches such as testing machines, material selection, testing environments, acceleration testing techniques and preventing methods are addressed. Future research prospects are suggested.

Integrity Estimation of The RC Members Damaged by Corrosion of Main Rebar (철근이 부식된 철근콘크리트 구조물의 건전도 평가기술)

  • Kwon, Dae Hong;Yoo, Suk Hyeong;Noh, Sam Young
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.141-146
    • /
    • 2007
  • It is necessary to guarantee the safety, serviceability and durability of reinforced concrete structures over their service life. However, concrete structures represent a decrease in their durability due to the effects of external environments according to the passage of time, and such degradation in durability can cause structural degradation in materials. In concrete structures, some degradations in durability increase the corrosion of embedded rebars and also decrease the structural performance of materials. Thus, the structural condition assessment of RC materials damaged by corrosion of rebars becomes an important factor that judges needs to apply restoration. In order to detect the damage of reinforced concrete structures, a visual inspection, a nondestructive evaluation method(NDE) and a specific loading test have been employed. However, obscurities for visual inspection and inaccessible members raise difficulty in evaluating structure condition. For these reasons, detection of location and quantification of the damage in structures via structural response have been one of the very important topics in system identification research. The main objective of this project is to develope a methodologies for the damage identification via static responses of the members damaged by durability. Six reinforced concrete beams with variables of corrosion position and corrosion width were fabricated and the damage detections of corroded RC beams were performed by the optimization and the conjugate beam methods using static deflection. In results it is proved that the conjugate beam method could predict the damage of RC members practically.

Monitoring of the Content of Imidazoline-Containing Corrosion Inhibitor

  • Zadorozhny, P.A.;Sukhoverkhov, S.V.;Markin, A.N.;Savin, K.I.;Prokuda, N.A.
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.161-166
    • /
    • 2017
  • The qualitative composition of active components of the corrosion inhibitor CGW-85567 was studied. It was found that С18:2 and С18:1 imidazolines and the corresponding imidazolin-amides are the major components. The HPLC/MS technique was developed for their determination in the water solutions of monoethylene glycol (MEG). Industrial application of the inhibitor showed that MEG solution retained high concentration of the inhibitor for a long time after ceasing its addition into pipelines. Low values of the partition coefficients (0.010-0.014) of imidazolines in the system "water solution of MEG (concentration of MEG 62-85% v/v) - gas condensate" have allowed to pass on from the technology of continuous pumping of the inhibitor into protected pipelines to the periodic dosing technology. Taking into account a long time of circulation in the system and high temperatures during MEG regeneration process possible degradation products of the inhibitor were studied. N, N-dimethyl-dodecanamine-1, and N, N-dimethyl-tetradecanamine-1 were identified as major degradation products of the corrosion inhibitor CGW-85567.

Corrosion image analysis on galvanized steel by using superpixel DBSCAN clustering algorithm (슈퍼픽셀 DBSCAN 군집 알고리즘을 이용한 용융아연도금 강판의 부식이미지 분석)

  • Kim, Beomsoo;Kim, Yeonwon;Lee, Kyunghwang;Yang, Jeonghyeon
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.3
    • /
    • pp.164-172
    • /
    • 2022
  • Hot-dip galvanized steel(GI) is widely used throughout the industry as a corrosion resistance material. Corrosion of steel is a common phenomenon that results in the gradual degradation under various environmental conditions. Corrosion monitoring is to track the degradation progress for a long time. Corrosion on steel plate appears as discoloration and any irregularities on the surface. This study developed a quantitative evaluation method of the rust formed on GI steel plate using a superpixel-based DBSCAN clustering method and k-means clustering from the corroded area in a given image. The superpixel-based DBSCAN clustering method decrease computational costs, reaching automatic segmentation. The image color of the rusty surface was analyzed quantitatively based on HSV(Hue, Saturation, Value) color space. In addition, two segmentation methods are compared for the particular spatial region using their histograms.

Contribution of Water Chemistry in Initiation of Some Accelerated Corrosion Processes in CANDU-PHWR Primary System

  • Pirvan, Ioana;Radulescu, Maria;Fulger, Manuela
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.85-91
    • /
    • 2008
  • By operation in aqueous environment at high temperature and pressure, the structural materials from Primary Heat Transport System (PHTS) cover with protective oxide films, which maintain the corrosion rate in admissible limits. A lot of potential factors exist, which conduct to degradation of the protective films and consequently to intensification of the corrosion processes. The existing experience of different nuclear reactors shows that the water chemistry has an important role in integrity maintaining of the protective oxide films. To investigate the influence of water chemistry (pH, O2 dissolved, $Cl^-$, $F^-$) on corrosion of some structural materials (carbon and martensitic steel, Zr and Ni alloys) and to establish the maximum permissible values, corrosion experiments by static autoclaving and electrochemical methods were performed. The experimental results allowed us to establish the contribution of the water chemistry in initiation and evolution of some accelerated corrosion processes.

Analysis of Degradation of Durability of the GDL with Various MPL Penetration Levels (MPL 침투깊이에 따른 GDL 내구성능 저하 특성 분석에 관한 연구)

  • Park, Jaeman;Cho, Junhyun;Ha, Taehun;Min, Kyoungdoug;Lee, Eunsook;Jyoung, Jy-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.77.1-77.1
    • /
    • 2010
  • Durability problems of gas diffusion layer(GDL) is one of the important issues for accomplishing commercialization of proton exchange membrane fuel cell(PEMFC). GDL is strongly related to the performance of PEMFC because one of the main function of GDL is to work as a path of fuel, air and water. When the GDL is degraded, it causes water balance problems such as the flooding phenomenon. Thus, investigating the durability characteristics of the GDL is important and understanding the GDL degradation process is needed. In this study, the GDLs are degraded by carbon corrosion stress method which is the electrochemical degradation mode. To determine the effects of carbon corrosion of the GDL, 1.45 V of potential is imposed for 96 hours. In this manner, in the previous research, the structure between the substrate and the MPL is weaken. Further investigations are needed to clarify this phenomenon. Therefore, in this study, the carbon corrosion stress method is carried out with GDLs which have various MPL penetration levels and the effects of the MPL penetration level on the characteristics change of the GDL are analyzed. The changes in characteristics are measured with various properties of GDL such as weight, thickness and static contact angle. The degraded GDL shows loss of their properties.

  • PDF