• Title/Summary/Keyword: Corresponding rate

Search Result 1,605, Processing Time 0.034 seconds

The Comparison of Waist Circumference, Waist to Hip Ratio and Body Mass Index in Female College Students (여대생의 허리둘레, 허리둔부 둘레비와 체질량지수 비고)

  • Paek, Kyung-Shin;Chaung, Seung-Kyo
    • Research in Community and Public Health Nursing
    • /
    • v.16 no.4
    • /
    • pp.527-533
    • /
    • 2005
  • Purpose: The purpose of this study was to validate waist circumference (WC) and waist to hip ratio (WHR) corresponding to body mass index (BMI) of $25kg/m^2$ and to survey the prevalence of hypertension according to obesity in female college students. Method: Weight, height, waist and hip circumferences and blood pressure were measured for each of 286 female college students in J City, Chungbuk. Results: The subjects' mean BMI was $21.4kg/m^2$, and the estimated prevalence of obesity was 11.2%. The subjects, the 80th-90th percentile of whom had BMI exceeding $25kg/m^2$, were found to have WC of 75-78.1 cm and WHR of 0.79-0.80, respectively. Of the subjects with obesity($BMI{\geq}25kg/m^2$), 53.1% exhibited abdominal obesity ($WC{\geq}80cm$) and 40.6% had WHR over 0.80. Systolic and diastolic blood pressure were correlated with BMI, WC, and WHR. The prevalence rate of hypertension in subjects with obesity($BMI{\geq}25kg/m^2$) was 25%. Additionally, the prevalence rate of hypertension in subjects with abdominal obesity ($WC{\geq}80cm$) was 39.1%. Conclusions: Our study indicates that WC corresponding to BMI of $25kg/m^2$ in female subjects in their twenties is different from that of adult women. We also found that the prevalence rate of hypertension in subjects with abdominal obesity was high. Therefore. we suggest further studies to determine the cutoff value of WC for evaluating abdominal obesity and to investigate the long-term effects of obesity on women in their twenties.

  • PDF

Multi-view Synthesis Algorithm for the Better Efficiency of Codec (부복호화기 효율을 고려한 다시점 영상 합성 기법)

  • Choi, In-kyu;Cheong, Won-sik;Lee, Gwangsoon;Yoo, Jisang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.375-384
    • /
    • 2016
  • In this paper, when stereo image, satellite view and corresponding depth maps were used as the input data, we propose a new method that convert these data to data format suitable for compressing, and then by using these format, intermediate view is synthesized. In the transmitter depth maps are merged to a global depth map and satellite view are converted to residual image corresponding hole region as out of frame area and occlusion region. And these images subsampled to reduce a mount of data and stereo image of main view are encoded by HEVC codec and transmitted. In the receiver intermediate views between stereo image and between stereo image and bit-rate are synthesized using decoded global depth map, residual images and stereo image. Through experiments, we confirm good quality of intermediate views synthesized by proposed format subjectively and objectively in comparison to intermediate views synthesized by MVD format versus total bit-rate.

Analysis and Classification of Acoustic Emission Signals During Wood Drying Using the Principal Component Analysis (주성분 분석을 이용한 목재 건조 중 발생하는 음향방출 신호의 해석 및 분류)

  • Kang, Ho-Yang;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.254-262
    • /
    • 2003
  • In this study, acoustic emission (AE) signals due to surface cracking and moisture movement in the flat-sawn boards of oak (Quercus Variablilis) during drying under the ambient conditions were analyzed and classified using the principal component analysis. The AE signals corresponding to surface cracking showed higher in peak amplitude and peak frequency, and shorter in rise time than those corresponding to moisture movement. To reduce the multicollinearity among AE features and to extract the significant AE parameters, correlation analysis was performed. Over 99% of the variance of AE parameters could be accounted for by the first to the fourth principal components. The classification feasibility and success rate were investigated in terms of two statistical classifiers having six independent variables (AE parameters) and six principal components. As a result, the statistical classifier having AE parameters showed the success rate of 70.0%. The statistical classifier having principal components showed the success rate of 87.5% which was considerably than that of the statistical classifier having AE parameters.

Effect of W Addition on the Hardenability of Low-Carbon Boron Steels (저탄소 보론강의 경화능에 미치는 W 첨가의 영향)

  • Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.24 no.9
    • /
    • pp.488-494
    • /
    • 2014
  • The effect of tungsten (W) addition on the hardenability of low-carbon boron steels was investigated using dilatometry, microstructural observations and secondary ion mass spectroscopy. The hardenability was discussed with respect to transformation behaviour aspects depending on the segregation and precipitation of boron at austenite grain boundaries. A critical cooling rate producing a hardness corresponding to 90 % martensite structure was measured from a hardness distribution plot, and was used as a criterion to estimate hardenability at faster cooling rates. In the low-carbon boron steel, the addition of 0.50 wt.% W was comparable to that of 0.20 wt.% molybdenum in terms of critical cooling rate, indicating hardenability at faster cooling rates. However, the addition of 0.50 wt.% W was not more effective than the addition of .0.20 wt.% molybdenum at slower cooling rates. The addition of 0.20 wt.% molybdenum completely suppressed the formation of eutectoid ferrite even at the slow cooling rate of $0.2^{\circ}C/s$, while the addition of 0.50 wt.% W did not, even at the cooling rate of $1.0^{\circ}C/s$. Therefore, it was found that the effect of alloying elements on the hardenability of low-carbon boron steels can be differently evaluated according to cooling rate.

Calculation of Neutron and Gamma-Ray Flux-to-Dose-Rate Conversion Factors (중성자(中性子) 및 감마선(線)에 대한 선량율(線量率) 환산인자(換算因子) 계산(計算))

  • Kwon, Seog-Guen;Lee, Soo-Yong;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.6 no.1
    • /
    • pp.8-24
    • /
    • 1981
  • This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute(ANSI) N666. These data are used to calculated the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from $2.5{\times}10^{-8}$ to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoetiergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be a useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions.

  • PDF

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

Non-contact Heart Rate Monitoring using IR-UWB Radar and Lomb-Scargle Periodogram (IR-UWB 레이더와 Lomb-Scargle Periodogram을 이용한 비접촉 심박 탐지)

  • Byun, Sang-Seon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • IR-UWB radar has been regarded as the most promising technology for non-contact respiration and heartbeat monitoring because of its ability of detecting slight motion even in submillimeter range. Measuring heart rate is most challenging since the chest movement by heartbeat is quite subtle and easily interfered with by a random body motion or background noise. Additionally, periodic sampling can be limited by the performance of computer that handles the radar signals. In this paper, we deploy Lomb-Scargle periodogram method that estimates heart rate even with irregularly sampled data and uneven signal amplitude. Lomb-Scargle periodogram is known as a method for finding periodicity in irregularly-sampled and noisy data set. We also implement a motion detection scheme in order to make the heart rate estimation pause when a random motion is detected. Our scheme is implemented using Novelda's X4M03 radar development kit and its corresponding drivers and Python packages. Experimental results show that the estimation with Lomb-Scargle periodogram yield more accurate heart rate than the method of measuring peak-to-peak distance.

Low Strain Rate Flame Extinction Characteristic of Oxygen Enhanced Opposed Flow Partially Premixed Flame in a Mesoscale Channel (채널 내부 대항류 산소부화 부분예혼합 화염의 저신장율 소화특성)

  • Lee, Min Jung;Kim, Nam Il
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.243-244
    • /
    • 2014
  • The opposed flow flame in a mesoscale channel was constructed to observe the flame stabilization behaviors at low strain rate conditions (<$10s^{-1}$). The purpose of this study is to get the overall flame behaviors of partially premixed flames with oxygen enhanced conditions at low strain rates. The oxygen ratio in oxidizer was changed from 18 to 30 %. Conclusively, the flame extinction limit approached to about $1s^{-1}$, and divided into three representative regimes corresponding to self propagating flame, transitional flame, quenching flame regimes.

  • PDF

Quasi-Static and Dynamic Loading Responses of Ti-6Al-4V Titanium Alloy: Experiments and Constitutive Modeling

  • Suh, Yeong-Sung;Akhtar S. Khan
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.191-194
    • /
    • 2003
  • The results from a systematic study of the response of a Ti-6Al-4V alloy under quasi-static and dynamic loading at different strain rates and temperatures are presented. It has been shown that the work-hardening rate decreased as the strain rate and the strain increased. The correlations and predictions using modified KHL (Khan-Huang-Liang) viscoplastic constitutive model are compared with those from JC (Johnson-Cook) model and experimental observations. Overall, KHL model correlations and predictions compared much more favorably than the corresponding JC model predictions and correlations.

  • PDF

Agricultural Fertilizers as Economical Alternative for Cultivation of Haematococcus pluvialis

  • Dalay Meltem Conk;Imamoglu Esra;Demirel Zeliha
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.393-397
    • /
    • 2007
  • A Haematococcus pluvialis strain isolated from the ruins of Ephesus in Turkey was investigated as regards its adaptation to laboratory conditions and maximum growth rate. In the first stage of the experiment, the growth of H. pluvialis was compared in common culture media. Furthermore, in an effort to minimize the culture costs, the second stage of the experiment compared the growth rate in the culture medium selected in the first stage with that in commercial plant fertilizers. The results demonstrated that the maximum cell concentration of 0.90 g/l, corresponding to a growth rate of $0.150d^{-1}$, was found with an N-P-K 20:20:20 fertilizer under a light intensity of $75{\mu}mol$ photons $m^{-2}s{-1}$ on the $12^{th}$ day of cultivation.