Correlation Algorithm for High-Precision Measurement in FM-CW Radar Level Meters (FM-CW 레이더 거리계의 비트 신호 스펙트럼 상관성을 이용한 고정밀 측정 알고리듬)

  • Kim, Jeong-Mok;Lim, Zong-Soo;Chun, Joong-Chang;Kim, Tae-Soo;Shim, Jae-Ryun;Park, Wee-Sang
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.38-44
    • /
    • 2001
  • In this paper, for the microwave level meter based on the FM-CW radar, we analyze the spectrum correlation of beat signals and propose a measurement algorithm using the theory. For industrial applications, level meters must have high precision, which requires a good linearity of VCO. But, in practice, it is very complicated or very expensive to make VCO linear enough to be acceptable in the industrial field. We propose a measurement algorithm using the fact that there exists a peak in the spectrum correlation of beat signals when range difference is sufficiently small. This makes it possible to determine the range difference in a precise manner even using a practical VCO. We present some experimental results to show the validity of this algorithm.

  • PDF

Short-term Comparison of Supervised Rehabilitation and Home-based Rehabilitation for Earlier Recovery of Shoulder Motion, Pain, and Function after Rotator Cuff Repair

  • Song, Si-Jung;Jeong, Tae-Ho;Moon, Jung-Wha;Park, Han-Vit;Lee, Si Yung;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.15-21
    • /
    • 2018
  • Background: This study was undertaken to compare the outcome of supervised and home exercises with respect to range of motion (ROM), pain, and Single Assessment Numeric Evaluation (SANE). We further correlated the ROM recovery and pain reduction as well. Methods: The study included 49 patients who underwent arthroscopic rotator cuff repair. Rehabilitation was initiated after 4 weeks of immobilization. A total of 29 patients performed supervised exercise 3 times a week. Standardized education and brochures for review were provided to the remaining 20 patients who insisted on home rehabilitation. Statistical analysis was performed for comparing pain Numerical Rating Scale (NRS), SANE, and ROM. In addition, we also evaluated the correlation between pain and ROM. Results: Comparison of the two groups revealed no significant differences in forward flexion, internal rotation, abduction, and pain NRS. However, SANE at the 9th week (63.8 vs. 55.0, p=0.038) and improvement of external rotation from the 5th to the 9th week (17.6 vs. 9.3, p=0.018) were significantly higher in the supervised exercise group as compared to the home exercise group. Correlation of pain NRS with forward flexion, external rotation, internal rotation and abduction were statistically not significant (correlation coefficient=0.032 [p=0.828], -0.255 [p=0.077], 0.068 [p=0.642], and -0.188 [p=0.196], respectively). Conclusions: The supervised rehabilitation after arthroscopic rotator cuff repair showed better improvement in external rotation and higher SANE score after 4 weeks of rehabilitation exercise. However, no statistically significant correlation was observed between the recovery of ROM and short-term pain relief.

The Relationship among Workplace Bullying, Organizational Commitment and Turnover Intention of the Nurses Working in Public Medical Institutions (공공의료기관에 근무하는 간호사가 경험하는 근무지 약자 괴롭힘과 조직몰입, 이직의도간의 관계)

  • Kang, Hei Young;Kim, Sanghee;Han, Kihye
    • Journal of Korean Clinical Nursing Research
    • /
    • v.24 no.2
    • /
    • pp.178-187
    • /
    • 2018
  • Purpose: The purpose of this study was to explore the relationships among workplace bullying, organizational commitment, and turnover intention of nurses. Methods: A cross-sectional study was conducted. Data were collected using a structured questionnaire from nurses at five public hospitals (N=190). Results: The experience of bullying was 31.29 points (range 16-64) on average: Work-related bullying was the highest, followed by verbal/non verbal bullying and external threats. The consequences of bullying were 30.54 points (range 13-52) on average: The physical/psychological withdrawal was the highest, followed by increasing distrust and the poor quality of patient care. The experiences of bullying had positive correlations with the consequences of bullying (r=.55, p<.001) and the turnover intention (r=.27, p<.001), and had a negative correlation with organizational commitment (r=-.28, p<.001). The consequences of bullying had a positive correlation with the turnover intention (r=.52, p<.001), and had a negative correlation with organizational commitment (r=-.49, p<.001). Organizational commitment showed a negative correlation with the turnover intention (r=.63, p<.001). Conclusion: The findings of this study suggests the needs of a regular monitoring system and organizational management for workplace bullying, which helps nurses to commit to their organization and to be retained in a workplace.

Comparison of Center of Pressure Displacement during Sit to Stand to Sit and Balance Ability of Subjects with and without Chronic Ankle Instability

  • Hyun-Sung Kim;Seung-Jun Oh
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.1
    • /
    • pp.13-20
    • /
    • 2023
  • Purpose : The purpose of this study is to compare the balance ability between subjects with chronic ankle instability and normal people and the center of pressure displacement during the sit to stand and stand to sit. Methods : The subjects of this study were 63 who met the inclusion criteria and were classified into normal group (n=33) and chronic ankle instability group (n=30). The displacement of the center of pressure during sit to stand and stand to sit was measured. And the limit of stability and Y-balance tests were performed to measure the balance ability. Independent t-test was conducted to compare center of pressure displacement and balance ability between groups, and pearson correlation was conducted to analyze the correlation between the center of pressure displacement and balance ability. Results : In the case of the center of pressure displacement, there was a significant difference between the two groups during sit to stand and stand to sit. In the case of balance, both limit of stability and Y-balance test showed significant differences between the two groups. At the time of sit to stand, the center of pressure displacement showed a significant correlation with balance abilities, and at the time of stand to sit, the center of pressure displacement showed a significant correlation with Y-balance test. Conclusion : Chronic ankle instability shows that there is a lot of sway in the body due to compensation to replace the decrease in ankle joint range of motion when performing sit to stand and stand to sit due to sensory input damage such as decrease in ankle range of motion and decrease in ankle proprioception. Chronic ankle instability is expected to have a negative effect on our daily lives in life. The results of this study will serve as the basis for the dynamic approach to objective evaluation, treatment, and prevention of chronic ankle instability.

The Effect of Second Toe Valgus on Correction Loss of Hallux Valgus Angle in Surgical Treatment (무지외반증 수술에서 제 2족지의 외반 정도가 무지 외반각 교정소실에 미치는 영향)

  • Kang, Suk Woong;Song, Moo Ho;Kim, Yeong Joon;Oh, Young Kwang;Yoo, Seong Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.135-138
    • /
    • 2017
  • Purpose: The purpose of this study is to determine the correlation between the correction loss of hallux valgus angle and the severity of valgus angle of the second toe. Materials and Methods: We selected 312 cases from 268 surgical patients with hallux valgus deformity receiving distal chevron osteotomy. For a radiological evaluation, we analyzed the changes in the hallux valgus angles, first to second intermetatarsal angles, and valgus angle of the second toe post index operations. All patients were women; the mean age was 46 years. The mean follow-up period was 17 months. Results: The mean hallux valgus angle was $33.6^{\circ}$ preoperatively (range, $25.7^{\circ}{\sim}44.8^{\circ}$), $13.1^{\circ}$ (range, $8.4^{\circ}{\sim}16.4^{\circ}$) after 4 weeks of postoperative period, and $17.1^{\circ}$ (range, $9.4^{\circ}{\sim}28.5^{\circ}$) at their final follow-up. The mean valgus angle of the second toe was $8.4^{\circ}$ preoperatively (range, $2.0^{\circ}{\sim}25.8^{\circ}$) and $8.3^{\circ}$ (range, $1.7^{\circ}{\sim}24.9^{\circ}$) at the final follow-up. Preoperatively, there was a positive correlation between the valgus angle of the second toe and hallux valgus angle (r=0.747, p=0.001). The correction loss of hallux valgus angle had a significant correlation with the severity of valgus angle of the second toe (r=0.802, p=0.001). Conclusion: The existence of the second toe valgus deformity may present itself as a cause of correction loss of hallux valgus angle. The preoperative measurement of the second toe valgus angle may be a good predictor of correction loss; therefore, thorough preoperative warning on the possibility of correction loss should be conducted to maximize patient satisfaction after the procedure.

Stress Indices of Hollow Circular Cross Section Welded Attachments on Piping Elbows with the Extended Parameters Range (매개변수 적용범위를 확장한 배관 곡관부에 용접 부착된 원형관 이음부의 이차응력지수)

  • Lee, Kun-Suk;Moon, Seong-Jae
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.43-51
    • /
    • 2019
  • The stress concentration of the integral welded attachments (IWA) often used to support piping system has been a big issue because it induces local stresses in piping. The method to evaluate local stresses associated with attachments on elbows has been suggested in EPRI TR-107453. However, there are limitations regarding specific parameters range in order to use correlation equation. In this paper, parametric study based on piping elbow size and attachment dimension was performed utilizing finite element analysis (FEA) to evaluate the secondary stress indices of hollow circular cross section welded attachments on piping elbows with the extended parameters range. The results of the FEA were used to develop correlation formulas for calculating secondary stress indices. The empirical equations in this study are suggested as an alternative evaluation method of EPRI TR-107453 by extending parameters range.

A Study on Range-Doppler Processing of Time Shifted LFM Signals based on Quasi Orthogonal Property (준 독립적 특성 기반의 시간이동 LFM 신호를 이용한 거리-도플러 처리에 대한 연구)

  • Suh, Kyoung-Whoan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.125-133
    • /
    • 2016
  • As one of solutions to pursue the efficient use of spectrum resource, we proposed the methodology for the co-channel multi-site radar operations with the synchronous GPS clock. The proposed algorithm, based on a quasi orthogonal property, find a candidate set of the time shifted linear frequency modulation(TSLFM) signals with the minimum acceptable level of the correlation among selected TSLFM signals. To check suggested algorithm, numerical analysis for several radars operating in the same channel with a sawtooth waveform has been performed by using range-Doppler processing for the given system parameters, and computational results are presented and examined in terms of range profile and doppler shift for a targets with velocity and distance. Simulated results have a good agreement with assumed target distance and its velocity, within the error of resolution.

Removal of Search Point using Motion Vector Correlation and Distance between Reference Frames in H.264/AVC (움직임 벡터의 상관도와 참조 화면의 거리를 이용한 H.264/AVC 움직임 탐색 지점 제거)

  • Moon, Ji-Hee;Choi, Jung-Ah;Ho, Yo-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.2A
    • /
    • pp.113-118
    • /
    • 2012
  • In this paper, we propose the removal of search point using motion vector correlation and distance between reference frames in H.264/AVC. We remove the search points in full search method and predictive motion vectors in enhanced predictive zonal search method. Since the probability that the reference frame far from the current frame is selected as the best reference frame is decreased, we apply the weighted average based on distance between the current and reference frame to determine the fianl search range. In general, the size of search range is smaller than initial search range. We reduce motion estimation time using the final search range in full search method. Also, the refinement process is adaptively applied to each reference frame. The proposed methods reduce the computational throughput of full search method by 57.13% and of enhanced predictive zonal search by 14.71% without visible performance degradation.

Assessment of Psychopathic Personality and Interpersonal Problems in Korean Criminal Offenders with Schizophrenia (치료 감호중인 조현병 환자에서 정신병질 성격과 대인관계문제)

  • Wang, Seung-Keun;Kwon, JeeHyun;Lee, Jae-Woo;Chee, Ik-Seung
    • Anxiety and mood
    • /
    • v.10 no.2
    • /
    • pp.157-162
    • /
    • 2014
  • Objective : This study was conducted to evaluate the validity of the Korean Inventory of Interpersonal Problems (K-IIP) with Psychopathic Personality Inventory-Revised (PPI-R) to assess interpersonal problems in Korean criminal offenders with schizophrenia. Methods : The sample consisted of 187 inpatients with schizophrenia who had committed crimes. All participants filled out self-report questionnaires ofPPI-R and K-IIP. Results : The result showed that all scales of K-IIP were correlated highly with the PPI-R total score (r range=0.25-0.65). Correlations with K-IIP scales were highest for Blame Externalization, Rebellious Nonconformity, and Machiavellian Egocentricity scales (r range=0.50-0.66, 0.43-0.64, 0.39-0.58, respectively). All scales of K-IIP exhibited a negative correlation with Social Influences, Stress Immunity, Coldheartedness (C) scale ofPPI-R. Cold/Distant scale ofK-IIP was not correlated with C scale of PPI-R. All scales of K-IIP was highly correlated with PPI-R-factor-2 (r range=0.44-0.71) and negatively correlated with PPI-R-factor-l (r range=-0.03-0.38). Conclusions : Despite of strong correlation between PPI-R total score and K-IIP total score, K-IIP was not correlated with PPI-R-I that represents affective and interpersonal deficits. It suggests K-IIP may not proper for measuring the interpersonal problems of criminal offenders with schizophrenia. It will be needed other assessment scale for measuring the interpersonal problems of psychopathy in criminal schizophrenia.

An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.