• Title/Summary/Keyword: Correction method

Search Result 3,406, Processing Time 0.031 seconds

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

Key-word Error Correction System using Syllable Restoration Algorithm (음절 복원 알고리즘을 이용한 핵심어 오류 보정 시스템)

  • Ahn, Chan-Shik;Oh, Sang-Yeob
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.165-172
    • /
    • 2010
  • There are two method of error correction in vocabulary recognition system. one error pattern matting base on method other vocabulary mean pattern base on method. They are a failure while semantic of key-word problem for error correction. In improving, in this paper is propose system of key-word error correction using algorithm of syllable restoration. System of key-word error correction by processing of semantic parse through recognized phoneme meaning. It's performed restore by algorithm of syllable restoration phoneme apply fluctuation before word. It's definitely parse of key-word and reduced of unrecognized. Find out error correction rate using phoneme likelihood and confidence for system parse. When vocabulary recognition perform error correction for error proved vocabulary. system performance comparison as a result of recognition improve represent 2.3% by method using error pattern learning and error pattern matting, vocabulary mean pattern base on method.

The evaluation of correction methods and effect of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method (직접필터법을 이용한 석영 분석시 고령석의 영향 및 보정방법 평가)

  • Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • To establish the Fourier-Transform Infra-Red spectrophotometry(FTIR) Direct-On-Filter(DOF) technique as a useful analytical method for quartz in respirable dust samples, an influence of the kaolinite should be corrected. Respirable dust, created in a dust chamber containing the standard material of quartz and kaolinite were collected using a cyclone equipped with a 25 mm, $0.8\;{\mu}m$ pore size DM filter as a collection medium. This study was designed to compare three methods of correction for kaolinite when quantifying the content of quartz, including the least square, the optimum choice and the spectral subtraction methods. The content of quartz in the respirable dust samples was overestimated by 6.2% when mixed with kaolinite(35.5% by weight). The content of quartz containing kaolinite(72.8% by weight) were overestimated by 32%. The spectral subtraction method underestimated the quartz content by 1.5%, while the other two correction methods, the optimum choice and the least square method, overestimated the quartz content by 1.9% to 6.4% and 0.04 to 1.1%, respectively. The results of this study are suggested that, when correcting for effects of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method, the least square method produce the most unbiased results be compared with those of other correction methods.

Automatic Jitter Evaluation Method from Video using Optical Flow (Optical Flow를 사용한 동영상의 흔들림 자동 평가 방법)

  • Baek, Sang Hyune;Hwang, WonJun
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1236-1247
    • /
    • 2017
  • In this paper, we propose a method for evaluating the uncomfortable shaking in the video. When you shoot a video using a handheld device, such as a smartphone, most of the video contains unwanted shake. Most of these fluctuations are caused by hand tremors that occurred during shooting, and many methods for correcting them automatically have been proposed. It is necessary to evaluate the shake correction performance in order to compare the proposed shake correction methods. However, since there is no standardized performance evaluation method, a correction performance evaluation method is proposed for each shake correction method. Therefore, it is difficult to make objective comparison of shake correction method. In this paper, we propose a method for objectively evaluating video shake. Automatically analyze the video to find out how much tremors are included in the video and how much the tremors are concentrated at a specific time. In order to measure the shaking index, we proposed jitter modeling. We applied the algorithm implemented by Optical Flow to the real video to automatically measure shaking frequency. Finally, we analyzed how the shaking indices appeared after applying three different image stabilization methods to nine sample videos.

The correction of support interference effect of belly sting (벨리 스팅 모형 지지부의 간섭 효과 보정기법 연구)

  • Kim, Nam-Gyun;Ahn, Seung-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.8
    • /
    • pp.30-36
    • /
    • 2002
  • Wind tunnel model has some difference in shape compared to the real flight vehicle because of model support system for testing. The support system can make some differences in the measured forces and moments to the flight test data. There are several correction methods involved such as cavity pressure correction and model support interference. Internal balance and belly sting support were used for this wind tunnel test and three types of model support correction methods, variable sting thickness method, dummy sting method, and wire support method, were compared. Variable sting thickness method is well matched with wire support method, which is known for almost interference free.

Distortion Correction Modeling Method for Zoom Lens Cameras with Bundle Adjustment

  • Fang, Wei;Zheng, Lianyu
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.140-149
    • /
    • 2016
  • For visual measurement under dynamic scenarios, a zoom lens camera is more flexible than a fixed one. However, the challenges of distortion prediction within the whole focal range limit the widespread application of zoom lens cameras greatly. Thus, a novel sequential distortion correction method for a zoom lens camera is proposed in this study. In this paper, a distortion assessment method without coupling effect is depicted by an elaborated chessboard pattern. Then, the appropriate distortion correction model for a zoom lens camera is derived from the comparisons of some existing models and methods. To gain a rectified image at any zoom settings, a global distortion correction modeling method is developed with bundle adjustment. Based on some selected zoom settings, the optimized quadratic functions of distortion parameters are obtained from the global perspective. Using the proposed method, we can rectify all images from the calibrated zoom lens camera. Experimental results of different zoom lens cameras validate the feasibility and effectiveness of the proposed method.

Data Correction For Enhancing Classification Accuracy By Unknown Deep Neural Network Classifiers

  • Kwon, Hyun;Yoon, Hyunsoo;Choi, Daeseon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.9
    • /
    • pp.3243-3257
    • /
    • 2021
  • Deep neural networks provide excellent performance in pattern recognition, audio classification, and image recognition. It is important that they accurately recognize input data, particularly when they are used in autonomous vehicles or for medical services. In this study, we propose a data correction method for increasing the accuracy of an unknown classifier by modifying the input data without changing the classifier. This method modifies the input data slightly so that the unknown classifier will correctly recognize the input data. It is an ensemble method that has the characteristic of transferability to an unknown classifier by generating corrected data that are correctly recognized by several classifiers that are known in advance. We tested our method using MNIST and CIFAR-10 as experimental data. The experimental results exhibit that the accuracy of the unknown classifier is a 100% correct recognition rate owing to the data correction generated by the proposed method, which minimizes data distortion to maintain the data's recognizability by humans.

Absolute Atmospheric Correction Procedure for the EO-1 Hyperion Data Using MODTRAN Code

  • Kim, Sun-Hwa;Kang, Sung-Jin;Chi, Jun-Hwa;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2007
  • Atmospheric correction is one of critical procedures to extract quantitative information related to biophysical variables from hyperspectral imagery. Most atmospheric correction algorithms developed for hyperspectral data have been based upon atmospheric radiative transfer (RT) codes, such as MODTRAN. Because of the difficulty in acquisition of atmospheric data at the time of image capture, the complexity of RT model, and large volume of hyperspectral data, atmospheric correction can be very difficult and time-consuming processing. In this study, we attempted to develop an efficient method for the atmospheric correction of EO-1 Hyperion data. This method uses the pre-calculated look-up-table (LUT) for fast and simple processing. The pre-calculated LUT was generated by successive running of MODTRAN model with several input parameters related to solar and sensor geometry, radiometric specification of sensor, and atmospheric condition. Atmospheric water vapour contents image was generated directly from a few absorption bands of Hyperion data themselves and used one of input parameters. This new atmospheric correction method was tested on the Hyperion data acquired on June 3, 2001 over Seoul area. Reflectance spectra of several known targets corresponded with the typical pattern of spectral reflectance on the atmospherically corrected Hyperion image, although further improvement to reduce sensor noise is necessary.

Gate CD Control for memory Chip using Total Process Proximity Based Correction Method

  • Nam, Byung--Ho;Lee, Hyung-J.
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.180-184
    • /
    • 2002
  • In this study, we investigated mask errors, photo errors with attenuated phase shift mask and off-axis illumination, and etch errors in dry etch conditions. We propose that total process proximity correction (TPPC), a concept merging every process step error correction, is essential in a lithography process when minimum critical dimension (CD) is smaller than the wavelength of radiation. A correction rule table was experimentally obtained applying TPPC concept. Process capability of controlling gate CD in DRAM fabrication should be improved by this method.

Iterative Attenuation Correction and Image Reconstruction Using Time-Of-Flight Positron Emission Tomography (양전자방출단층촬영기의 비행시간정보를 이용한 반복적 감쇠보정 및 영상재구성)

  • Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1371-1376
    • /
    • 2016
  • In this paper, an iterative method is proposed to perform attenuation correction and image reconstruction simultaneously for positron emission tomography, by using the time-of-flight information. Numerical simulation results are presented to demonstrate an improved performance of the proposed method in attenuation correction and image reconstruction.