• Title/Summary/Keyword: Correction effect

Search Result 1,367, Processing Time 0.027 seconds

An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correction Converter with Active Clamp Circuit (능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터)

  • 이준영;문건우;고관본;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.626-630
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi-resonant converter (QRC) for the power factor correction(PFC) converter is introduced in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of an input current. The proposed converter has the characteristics of the good power factor, low line current harmonics, and tight output regulation. Furthermore, the ringing effect due to the output capacitance of the main switch can be eliminated by use of active clamp circuit.

  • PDF

MONTE CARLO SIMULATION FOR CORRECTION OF IONIZATION CHAMBER WALL

  • Kurosawa, Tadahiro;Takata, Nobuhisa;Koyama, Yasuji
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.271-273
    • /
    • 2001
  • In precise measurement of air kerma with cavity ionization chambers, the effect of wall attenuation and scatter are corrected by Kwall and that of nonuniformity by Knu. Using the EGS4 code, we calculated these two correction factors. Correction factors calculated for two different-sized cylindrical ionization chamber differ by up to 0.7% from those obtained by measurements.

  • PDF

Red-Eye Removal Using an Inpainting Method (인페인팅 기법을 이용한 적목현상 제거)

  • Yoo, Seung-Hwan;Park, Rae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.365-366
    • /
    • 2007
  • In this paper, a novel correction method of red-eye effect is proposed. Conventional methods simply reduce red components in red-eye regions, not considering the expanded size of a pupil, thus the correction results can be unnatural. In the proposed method, an exemplar-based inpainting method is used for reducing the pupil region and filling the iris texture instead. Experimental results show that the proposed method is effective and its correction results look more natural than those of conventional methods.

  • PDF

Effect of a Five-week Scapular Correction Exercise in Patients with Chronic Mechanical Neck Pain

  • Lee, Kang-Seong
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.2
    • /
    • pp.126-131
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the change in pain, Neck Disability Index score, and the craniovertebral angle by performing scapular correction exercise or general neck exercise for five weeks in participants with mechanical neck pain. Methods: A total of 31 participants were randomly assigned between the scapular correction exercise and the general neck exercise groups, and all participants performed intervention for 40 minutes each, three times a week for five weeks The effects were evaluated by measuring the Visual Analog Scale score, the Neck Disability Index score, and the craniovertebral angle, before and after the intervention. Independent t-tests were used to compare differences between two groups, and to compare differences between pre- and post-intervention, paired t-tests were used. Results: As measured before and after the intervention, the scapular correction exercise group showed significant improvement in all variables (p<0.05), while the general neck exercise group improved only in the neck disability index score. The differences between the two groups revealed further improvement in the scapular correction exercise group compared to the general neck exercise group (p<0.05). Conclusion: We found that five weeks of the scapular correction exercise to modify the position and movements of the scapula is clinically an important treatment tool for recovery from chronic mechanical neck pain symptoms and restoration of proper neck function.

A Study of Static Bias Correction for Temperature of Aircraft based Observations in the Korean Integrated Model (한국형모델의 항공기 관측 온도의 정적 편차 보정 연구)

  • Choi, Dayoung;Ha, Ji-Hyun;Hwang, Yoon-Jeong;Kang, Jeon-ho;Lee, Yong Hee
    • Atmosphere
    • /
    • v.30 no.4
    • /
    • pp.319-333
    • /
    • 2020
  • Aircraft observations constitute one of the major sources of temperature observations which provide three-dimensional information. But it is well known that the aircraft temperature data have warm bias against sonde observation data, and therefore, the correction of aircraft temperature bias is important to improve the model performance. In this study, the algorithm of the bias correction modified from operational KMA (Korea Meteorological Administration) global model is adopted in the preprocessing of aircraft observations, and the effect of the bias correction of aircraft temperature is investigated by conducting the two experiments. The assimilation with the bias correction showed better consistency in the analysis-forecast cycle in terms of the differences between observations (radiosonde and GPSRO (Global Positioning System Radio Occultation)) and 6h forecast. This resulted in an improved forecasting skill level of the mid-level temperature and geopotential height in terms of the root-mean-square error. It was noted that the benefits of the correction of aircraft temperature bias was the upper-level temperature in the midlatitudes, and this affected various parameters (winds, geopotential height) via the model dynamics.

Effect of Correction to Muscle Imbalance in Lower Limbs according to Reduction of Weight Bearing Methods of Four Point of Horizontal Shaft (횡축 4정점 체중부하 감소기법 이용한 하지 근력불균형 개선에 미치는 효과)

  • Kang, S.R.;Kim, U.R.;Jeong, H.C.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.101-107
    • /
    • 2013
  • In this paper, we were to investigate effect of correction to muscle imbalance in lower limbs according to reduction of weight bearing methods of four point of horizontal shaft using two-belt treadmill. Participants were divided to two group according to each ten peoples who have difference of muscle function in left and right legs over 20%. Experiment progressed forty minutes a day three days a week, total four weeks and we estimated the maximal peak torque and average power for testing joint torque in hip, knee and ankle. The results showed that the correction effect of muscle imbalance to the maximal muscle strength was the most effective in hip joint. Also in knee joint, correction effect of muscular reaction was the most effective too. We thought that reduction of weight bearing methods could be positive effect to correct muscle imbalance in lower limbs.

  • PDF

Effect of Ambient Temperature on Bovine Erythrocyte Sedimentation Rate as Measured by Angled Capillary Method (경사모세관법에 의한 우의 적혈구침강 속도에 미치는 환경온도의 영향)

  • Kim Kyeong-Jin;Lee Bang-Whan
    • Journal of Veterinary Clinics
    • /
    • v.4 no.1
    • /
    • pp.395-401
    • /
    • 1987
  • In this study, the effect of ambient temperature on the 45$^{\circ}$micro ESR/hr of cattle blood were observed, and a correction chart for correcting observed values at any ambient temperature to standard values at 20$^{\circ}C$ was plotted. Besides, the effect of storage temperature of blood on the 45$^{\circ}$micro ESR/hr was surveyed. The results were as follows: 1. The values of the 45$^{\circ}$micro ESR/hr were increased as the ambient temperature were elevated(P<0.01), and lower the value of PCV, higher the effect of temperature on the 45$^{\circ}$micro ESR/hr was observed(P<0.01). 2. Regression of values of 45$^{\circ}$micro ESR to ambient temperature in all the group of different level of blood PCV showed linear regression with the highly significant coefficient of correlation. With the results, correction chart was drawn as in Fig. 1. 3. In the purpose to verify the reliability of correction chart, observed values of 45$^{\circ}$micro ESR/hr in field(out door) were corrected to values at 20$^{\circ}C$ by the correction chart(Fig. 1), comparing with the observed values at 20$^{\circ}C$ of standard temperature. No significant differences were found between two groups mentioned above. 4. In the study on the effect of storage temperature of the blood on the 45$^{\circ}$micro ESR/hr, group of storage temperature at 5$^{\circ}C$ showed statistically no significant differences untill 24 hours in contrast with standard control group.

  • PDF

The posture correction effect of functional clothing to prevent turtle neck syndrome (거북목 증후군 예방용 기능성 의류의 자세 교정 효과)

  • Kim, Hyunsook;Chun, Jongsuk;Jee, Jungwoo
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.3
    • /
    • pp.358-366
    • /
    • 2016
  • This study was performed to measure the posture correction effect of wearing ergonomic experimental clothing. Two types of experimental clothing (A, B) were developed. Both of them reinforced the muscles surrounding the spine. Experimental clothing A was developed by reflecting the shape and position of the pectoralis major muscle, abdominal muscle, and latissimus dorsi muscle. Experiment clothing B was developed by reflecting the integrated form of those muscles. Subjects were males in their 20s~30s (n=32). They were divided into two groups based on their acromion distance (AD): the turtle neck syndrome group (n=16, AD=3.81cm) and the normal group (n=16, AD=1.27cm). The correction of body posture was detected by three index values: change of the cervical curvature angle, horizontal distance between the seventh cervical vertebra and tragion, and AD. The comfort and tightness of the clothing were also measured. The results showed that both types of experimental clothing corrected body posture and that turtle neck syndrome can be prevented by wearing these types of posture correcting clothing. Two index values were decreased: cervical curvature angle ($0.31{\sim}1.32^{\circ}$) and horizontal distance between seventh cervical vertebra and tragion (0.22~0.31cm). The chest was also stretched. The comfort was rated as good for both types of experimental clothing. These results indicate that the experimental clothing had a posture correction effect without any discomfort for daily living.

The Effect of Attraction by the Atmosphere to Gravity (중력(重力)의 대기보정(大氣補正)에 대(對)한 연구(硏究))

  • Choi, Kwang-sun
    • Economic and Environmental Geology
    • /
    • v.16 no.2
    • /
    • pp.79-81
    • /
    • 1983
  • The effeet of the mass of the earth's atmosphere for gravity is studied. The computed correction value of the air mass effect is g=+0.86-0.0978 h (km) mgal and has always positive sign. In comparision with usual gravity works. this value is relatively large. So that, all gravity works always carry out this correction.

  • PDF