• Title/Summary/Keyword: Correction curve

Search Result 209, Processing Time 0.028 seconds

Light Curve Analyses of the Eclipsing Binary EROS 1010 in the Large Magellanic Cloud (대마젤란은하 식쌍성 EROS 1010의 광도곡선 분석)

  • Hong, Kyeong-Soo;Kang, Young-Woon
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.3
    • /
    • pp.295-304
    • /
    • 2009
  • We present BV light curves of EROS 1010 which is located in the central bar of the Large Magellanic Cloud. The BV light curves including BR and I light curves observed by the EROS and OGLE projects, have been analyzed using the 2005 version of the Wilson & Devinney Differential Correction program for the photometric solutions. The absolute dimensions of EROS 1010 were calculated by adopting the distance modulus of the Large Magellanic Cloud, $m-M=18.^m3{\sim}18.^m5$.

CCD PHOTOMETRY OF CONTACT BINARY WZ Cephei (접촉쌍성 WZ Cephei의 CCD 측광관측)

  • Lee, Woo-Baik;Kang, Young-Woon;Oh, Kyu-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • We present the full BVR light curves and five times of minima of WZ Cep to provides a complete photometric solution and to confirm the long term variation of the light curves. Our light curves show symmetry while previous light curves of Hoffmann (1984) show a high degree of asymmetry (the O'Connell effect). The BVR light curves were analyzed by the method of Wilson-Devinney Differential Correction. Our photometric results show a good agreement with those of Djurasevic et al. (1998).

The Error Analysis of measuring wind speed on Met Mast Shading Effect (기상탑 차폐 영향에 따른 측정 풍속의 오차 분석)

  • Ko, Suk-Whan;Jang, Moon-Seok;Lee, Yoon-Sub
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.1-7
    • /
    • 2011
  • In the performance test for wind turbines of medium and large, The reference met-mast should be installed for measurement reference wind speed as IEC 61400-12-1 standards and design of booms for mounted an anemometer must be considered exactly. Boom-mounted cup anemometer are influenced by flow distortion of the mast and the boom. Therefore design of booms must be important so that flow distortion due to booms should be kept below 0.5%. But, in some cases at size of met-mast structure, the distance of boom from mast is longer then measurement of wind speed is impossible because of oscillation of boom-mounted anemometer. In this paper, We measured a wind speed at several point from mast and boom and we analyzed the error of wind speed at each point of measurement. Also, we will suggest a correction method using the data curve fitting about errors of wind speed between each point of mounted anemometer.

A Study on the Adjustment of the Magnetic Compass on the Vessel alongside the Wharf (접안된 선박에 있어서 자기 compass 의 자착수정에 관한 연구)

  • 이상집;노태현
    • Journal of the Korean Institute of Navigation
    • /
    • v.12 no.2
    • /
    • pp.23-32
    • /
    • 1988
  • This paper offers a method of magnetic compass adjustment for the vessel alongside the wharf using newly designed magnetic north former, which makes the same magnetic field-change as the turning vessel does. The characteristics of the magnetic north former was examined by observing the deviation curves of the magnetic compass installed on the compass deviascop at laboratory. The magnetic north former consists of A and B arms which hold the permanent bar magnets at the both ends of each arm. The arm is to rotae in the horizontal plane about the vertical axis fixed at the center boss of the magnetic compass and it is to compensate the horizontal plane about the vertical axis fixed at the center boss of the magnetic compass and it is to compensate the horizontal component of the earth's field. The B arm makes the artificial magnetic north around the magnetic compass for every ship's heading. The results of investigation are summarized as follows ; 1. The observation and correction of magnetic compass deviation can be done without swinging the ship, of the effect of D coefficient is negligible. 2. The residual deviation curve of the magnetic compass depends on the accuracy of deduced value of ship's multplier($\lambda$). 3. The errors due to the inaccuracy of deduced value of ship's multiplier change in the same way as the B and C coefficient do.

  • PDF

A study on simplified fatigue design methodology for composite structures (복합재구조물에 대한 단순화된 수명평가방법 고찰)

  • 김성준
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.75-78
    • /
    • 2002
  • A simplified methodology is presented to predict fatigue life and residual strength of composite structures. To avoid excessive amount of tests that are required for model characterization, strength degradation parameter is assumed as function of fatigue life. S-N curve is used to extract fatigue life that is required to characterize the stress levels comprising a randomly-ordered load spectrum. And different stress ratios are handled with Goodman correction approach(fatigue envelope). It is assumed that the residual strength is a function of the number of loading cycles and applied fatigue stress amplitude. And the residual strength distribution after an arbitrary load cycles is represented by two parameter Weibull functions.

  • PDF

Post-earthquake building safety evaluation using consumer-grade surveillance cameras

  • Hsu, Ting Y.;Pham, Quang V.;Chao, Wei C.;Yang, Yuan S.
    • Smart Structures and Systems
    • /
    • v.25 no.5
    • /
    • pp.531-541
    • /
    • 2020
  • This paper demonstrates the possibility of evaluating the safety of a building right after an earthquake using consumer-grade surveillance cameras installed in the building. Two cameras are used in each story to extract the time history of interstory drift during the earthquake based on camera calibration, stereo triangulation, and image template matching techniques. The interstory drift of several markers on the rigid floor are used to estimate the motion of the geometric center using the least square approach, then the horizontal interstory drift of any location on the floor can be estimated. A shaking table collapse test of a steel building was conducted to verify the proposed approach. The results indicate that the accuracy of the interstory drift measured by the cameras is high enough to estimate the damage state of the building based on the fragility curve of the interstory drift ratio. On the other hand, the interstory drift measured by an accelerometer tends to underestimate the damage state when residual interstory drift occurs because the low frequency content of the displacement signal is eliminated when high-pass filtering is employed for baseline correction.

An Instrument for Continuous Measurement of Double Layer Capacitance (이중층 전기용량 연속 측정 장치)

  • Czae Myung-Zoon;Woo Seung-Soo;Choi Q. Won
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.674-678
    • /
    • 1992
  • An instrument is described that can obtain directly the whole capacitance vs. potential curve and accurately even in dilute solutions using positive feedback for IR correction. Applying a small (7∼10 mV) triangular signal, controlled rectification of the resulting square wave using sample-and-hold circuit allows one to plot the corrected double layer capacitance over a wide potential range. Several illustrations involving the improved performance characteristics of its applicability are given and its limitations discussed.

  • PDF

Design Method of the Meander-Coupled Wilkinson Power Divider for L-band (미앤더(Meander) 결합 형태의 Wilkinson 전력 분배기 설계 방법)

  • 이영순;이창언;김선효;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.676-685
    • /
    • 2001
  • In this paper, the design method of the meander-coupled Wilkinson power divider with slit is proposed. Because the electrical performance of this structure is varied with each coupling distance and the slit's size, a tedious design work, which is done by trial and error correction, is required to determine the values of parameters for the best suitable operation. To solve this problems, therefore, an experimental design formulas for optimum performance are presented by curve fitting, under the desired center frequency($f_0$). As the example using the proposed design equation, we designed and fabricated the meander-coupled divider at $f_0$=1.5 GHz. It has better electrical performance and measured results also agrees very well that of the simulated. From these observation, it can be concluded that the obtained design formulas are useful for design of this divider.

  • PDF

A Study on the Korean Women′s Wear Grading by Different Age Groups I (국내 여성복 브랜드 그레이딩의 연령별 비교에 관한 연구 I)

  • 최윤선;김소라;송미령
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.4
    • /
    • pp.377-391
    • /
    • 2002
  • The purpose of this study was to research grading work according to the targets of women's wear manufacturers in Korea. For the questionnaire, 91 women's wear brands, which were in higher ranking of sales, were selected, and the age groups were separated into 3: 20's, 30's, and 40's & 50's, according to their customers. The graders of each brand were questioned about 20 items for this research. The results of the questionnaire were as follows: 1 The brands for older women manufactured more sizes and cared more about somatotypes fur grading than other brands did. 2. For upper garments on the basis of bust girth, the numbers of dimensional increments were different depending on the age groups: 9 for 20's, 7 for 30's, and 7 for 40's & 50's. 3. For lower garments on the basis of hip girth, the numbers of dimensional increments were different depending on the age groups: 9 for 20's, 6 for 30's, and 5 for 40's & 50's. 4. As a model size of grading, many brands used the smallest size, but the brands for 40's & 50's also used the second size. 5. The parts needed to be corrected after grading were sleeve ease, armhole, shoulder line, neckline, crotch curve, etc. The grading with CAD system had more correction after grading than hand grading.

  • PDF

Spectroscopy of Early-Type Host Galaxies of Type Ia Supernovae

  • Kang, Yijung;Lim, Dongwook;Kim, Young-Lo;Chung, Chul;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.29.2-29.2
    • /
    • 2013
  • The presence of dark energy, suggested from Type Ia supernovae (SNe) cosmology, is the most pronounced astronomical discovery made during the past decade. The basic assumption of this discovery is that the look-back time evolution of SNe luminosity would be negligible after light-curve correction. Several recent works, however, show that there are some differences in Hubble residual among host galaxies having different morphology and mass, indicating that SNe luminosity might be affected by population age. In order to investigate this more directly, we are continuing the YONSEI (YOnsei Nearby Supernovae Evolution Investigation) project, where we are obtaining low-resolution spectra of some 60 nearby early-type host galaxies. The early-type galaxies are preferred because the mean population ages and metallicities can be estimated from the absorption lines, and they are less affected by dust extinction. In this talk, we will report our progress in determining the ages and metallicities of host galaxies to investigate their correlation with the Hubble residual.

  • PDF