• Title/Summary/Keyword: Corporation performance

Search Result 1,796, Processing Time 0.031 seconds

An Analysis of the Relationship between Surface Profile Error of f-$\theta$Lens and Optical Performance (f-$\theta$렌즈 표면형상오차와 광학적 성능과의 연관성 분석)

  • Kim, Dong-Sik;Lee, In-Yong;Kim, Hyeong-Chae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.90-95
    • /
    • 2001
  • f-$\theta$len is one of the important parts in Laser Scanning Unit because it affects on the optical performance of Laser Scanning Unit dominantly. It is necessary to find out the relationship between the surface profile error of f-$\theta$lens and the beam profile focusing on the Organic Photo Conductive drum in order to analysis the beam profile problems such as appearance of side lobe and expansion of center lobe. In this research, a simulation process which relates the surface profile characteristics to the beam profile has been developed by CODE V. The simulated beam profile also have been compared with the measurement results.

  • PDF

Performance Evaluation and Development of the Power Conditioning System for 250kW Molten Carbonate Fuel Cell (250kW급 MCFC용 전력변환기 개발 및 성능평가)

  • Lee, Jin-hee;Son, Ui-kwon;Suh, In-young
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.261-262
    • /
    • 2010
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a Molten Carbonate Fuel Cell (MCFC) for high power generation system. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of 250kW PCS was implemented and verified respectively. Experimental performances are compared to minimum target requirements of the PCS for MCFC respectively.

  • PDF

Influence of Joint on Retrofitting Effect by Exterior Steel Frames of Existing RC Buildings (외부접합공법의 내진보강효과에 미치는 접합부의 영향)

  • Ahn, Choong Weon;Min, Chan Gi;Noh, Eun Choul;Han, Hong Soo;Kim, Tae Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.183-194
    • /
    • 2015
  • In this paper, Nonlinear Static Pushover analysis method(NSP) is proposed which apply to RC buildings reinforced by external retrofit for seismic performance. Based on previous analysis and research, NSP is more developed by connection nonlinearity according to shear resistance mechanism such as dowel and adhesive resistance as major shear resistance elements. According to the proposed method, structural analysis for example buildings was carried out to evaluate seismic performance of buildings. And, it was confirmed that depending on shear strain and characteristics of joint resistant of external retrofitting are different from internal retrofitting. Furthermore, the strength reduction coefficient of the anchor needs to be considered at the joint design.

Performance Prediction of 3 MWth Chemical Looping Combustion System with Change of Operating Variables (3 MWth 급 매체순환연소 시스템의 운전변수 변화에 따른 성능 예측)

  • RYU, HO-JUNG;NAM, HYUNGSEOK;HWANG, BYUNG WOOK;KIM, HANA;WON, YOOSEOB;KIM, DAEWOOK;KIM, DONG-WON;LEE, GYU-HWA;CHOUN, MYOUNGHOON;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.419-429
    • /
    • 2022
  • Effects of operating variables on temperature profile and performance of 3 MWth chemical looping combustion system were estimated by mass and energy balance analysis based on configuration and dimension of the system determined by design tool. Air reactor gas velocity, fuel reactor gas velocity, solid circulation rate, and solid input percentage to fluidized bed heat exchanger were considered as representative operating variables. Overall heat output and oxygen concentration in the exhaust gas from the air reactor increased but temperature difference decreased as air reactor gas velocity increased. Overall heat output, required solid circulation rate, and temperature difference increased as fuel reactor gas velocity increased. However, overall heat output and temperature difference decreased as solid circulation rate increased. Temperature difference decreased as solid circulation rate through the fluidized bed heat exchanger increased. Effect of each variables on temperature profile and performance can be determined and these results will be helpful to determine operating range of each variable.

Developing High-Performance Polymer Electrolyte Membrane Electrolytic Cell for Green Hydrogen Production (그린수소 생산을 위한 고성능 고분자 전해질막 전해조 개발 연구)

  • Choi, Baeck Beom;Jo, Jae Hyeon;Lee, Yae Rin;Kim, Jungsuk;Lee, Taehee;Jeon, Sang-Yun;Yoo, Young-Sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.137-143
    • /
    • 2021
  • As an electrochemical water electrolysis for green hydrogen production, both polymer electrolyte membrane (PEM) and alkaline electrolyte are being developed extensively in various countries. The PEM electrolyzer with high current density (above 2 A/cm2) has the advantage of being able to design a simple structure. Also, it is known that it has high response to electrical output fluctuations. However, the cost problem of major components is the most important issue that a PEM electrolyzer must overcome. Instantly, there are platinum group metal (PGM)-based electrocatalysts, fluorine-based polyfluoro sulfuric acid (PFSA) membrane, Ti felt (porous transport layer, PTL) and so on. Another challenging issue is productivity. A securing outstanding productivity brings price benefits of the electrolytic cells. From this point of view, we conducted basic studies on manufacturing electrode and membrane electrode assembly (MEA) for PEM electrolyzer production.

A Study on the Application and Verification of Statistical Techniques for Calculating the Life of Electric Power Facilities (전력설비의 수명계산을 위한 통계적 분석기법의 활용 및 검증에 대한 연구)

  • Lee, Onyou;Kim, Kang-Sik;Lee, Hongseok;Cho, Chongeun;Kim, Sang-Bong;Park, Gi-Hun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 2022
  • Social infrastructure facilities such as production, transportation, gas and electricity facilities may experience poor performance depending on time, load, temperature, etc. and may require maintenance, repair and management as they are used. In particular, in the case of transformers, the process of managing them for the purpose of preventing them from failing is necessary because a failure can cause enormous social damage. The management of transformers should consider both technical and economic aspects and strategic aspects at the same time. Thus, it applies the Asset Management concept, which is widely used in the financial industry as an advanced method of transformer management techniques worldwide. In this paper, the operation and power outage data were secured for the asset management of the transformer for distribution, and the asset status was analyzed. Analysis of asset status using actual operation and power outage data is essential for assessing the statistical life and failure rate of the facility. Through this paper, the status of transformer assets for arbitrary A group distribution was analyzed, and the end of life and replacement life were calculated.

Performance-based Design of 300 m Vertical City "ABENO HARUKAS"

  • Hirakawa, Kiyoaki;Saburi, Kazuhiro;Kushima, Souichirou;Kojima, Kazutaka
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.35-48
    • /
    • 2014
  • In designing a 300 meter high skyscraper expected to be the tallest building in Japan, an earthquake-ridden country, we launched on the full-scale performance based design to ensure redundancy and establish new specifications using below new techniques. The following new techniques are applied because the existing techniques/materials are not enough to meet the established design criteria for the large-scale, irregularly-shaped building, and earth-conscious material saving and construction streamlining for reconstructing a station building are also required: ${\bullet}$ High strength materials: Concrete filled steel tube ("CFT") columns made of high-strength concrete and steels; ${\bullet}$ New joint system: Combination of outer diaphragm and aluminium spray jointing; ${\bullet}$ Various dampers including corrugated steel-plate walls, rotational friction dampers, oil dampers, and inverted-pendulum adaptive tuned mass damper (ATMD): Installed as appropriate; and ${\bullet}$ Foundation system: Piled raft foundation, soil cement earth-retaining wall construction, and beer bottle shaped high-strength CFT piles.

Effect of the Exhaust Heat from Micro Gas Turbine on the Performance Characteristics of the Absorption Chiller (마이크로가스터빈 배열부하가 배가스흡수식 냉온수기의 성능에 미치는 영향)

  • Choi Kyoung-Shik;Sohn Wha-Seung;Kim HyoungSik;Rhim Sang-Kyu;Hur Kwang-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.158-162
    • /
    • 2006
  • Micro gas turbine (MGT) has received attention recently as a small-scale distributed power source. Due to many advantages such as their small size, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of applications. The exhaust heat emitted by the MGT is in the form of an exhaust gas that is about $270^{\circ}C$ which is an extremely clean gas. Korea Gas Corporation (KOGAS) has researched performance characteristics of a cogeneration system combining 28kW class MGT and 13 USRT class absorption hot and chilled water generator in the local condition. The present results of this study can be summarized as follows: (1) in heating mode, the total efficiency of cogen. system is about $65\%$ and heating capacity is 33kW at 25kW MGP power (2) in cooling mode, COP is about 0.6 at 22kW MGT power.

In-situ Measurement Technique for Thermal Performance of Building Wall Excluding Surface Heat Transfer Resistance (표면 열전달 저항이 배제된 건물 벽체 열성능 현장 측정 기법)

  • Kim, Seungchul;Kim, Sangbong;Nah, Hwanseon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.151-155
    • /
    • 2020
  • In this paper, a new experimental method to determine the thermal resistance of building wall was proposed by improving the heat flow method (HFM) based on the air-surface temperature ratio theory. This technique measures the thermal resistance of the wall excluding the inner and outer surface heat transfer resistance. Unlike conventional HFM, this value can be compared directly with the theoretical reference value. Its performance was verified using three mock-up structures with a theoretical thermal transmittance of 0.5, 3.3, and 0.18 W/㎡·K respectively. After measuring the variations in the temperature and heat transfer rate of the mock-ups for 383 hours, the thermal transmittances were determined to be 0.47, 3.10, and 0.18 W/㎡·K, which corresponded to errors of 5.2, 6.2 and 0.5%, respectively, compared to the theoretical values. It was concluded that this technique can directly compare the thermal resistance of the wall between the existent stage and initial stage after construction.

Structural Design of High-Rise Concrete Condominium with Wall Dampers for Vibration Control

  • Tsushi, Takumi;Ogura, Fumitaka;Uekusa, Masahiro;Kake, Satoshi;Tsuchihashi, Toru;Yasuda, Masaharu;Furuta, Takuya
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.201-209
    • /
    • 2019
  • This paper presents a structural design of the "(Tentative Name) Toranomon Hills Residential Tower" which is currently under construction in Tokyo. The building is a reinforced concrete high-rise residential complex building with 54 stories above ground, 4 basement levels, and a building height of about 220 m. It is a requirement to provide the highest grade of residence in Japan, and in terms of the structural design, it is required to provide wide and comfortable spaces with high seismic performance. These requirements are satisfied by providing a total of 774 vibration control walls of two types. Also, to further improve the structural performance, steel fibers at the rate of 1.0vol% are provided in the ultra-high strength concrete used in the column members.