• Title/Summary/Keyword: Corporation performance

Search Result 1,796, Processing Time 0.032 seconds

Capabilities of Two Chromium Powder Metallurgy Steels for High Performance Applications at Conventional Sintering Temperatures

  • Kinga, Patrick;Lindsley, Bruce
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.134-135
    • /
    • 2006
  • Ancorsteel 4300, a high performance Cr-Si-Ni-Mo steel, was unveiled two years ago as the first in a series of powder metallurgy alloys that will simulate wrought steel compositions. Advantages of this alloy include good compressibility, high hardenability, and excellent dimensional stability. More important, however, is that this alloy has the ability to be effectively sintered at $1120^{\circ}C$ and maintain oxygen contents below 500 ppm. This unique blend of performance and processing capabilities provides static and dynamic properties that exceed those of conventional powder metallurgy alloys and approach wrought gearing materials. A second Cr-Si-Ni-Mo alloy has now been developed that offers complimentary performance levels at a lower Mo content. This manuscript reviews properties of the two chromium steels with comparisons to traditional sinter-hardened and heat-treated powder metallurgy alloys.

  • PDF

An examples of a 6-inch GTO inverter drive system applied for rougher mills

  • Kawasaki, Muneo;Okayama, Hideo;Koyama, Masato;Mitsuhashi, Masamichi;Masuda, Hiroyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.25-28
    • /
    • 1996
  • Recently, AC variable-speed motors are used for many steel rolling mill drive systems, because of their low maintenance and enhanced control performance. We have been applied GTO inverters for these AC motor drive systems since 1993. We have developed world largest 6-inch diameter GTO and large capacity 3-level GTO inverter up to 20000(kVA). As an example, in this paper, we describe the main circuit, system arrangement and control features of the 6-inches GTO inverters to drive rougher mills for hot strip mill of Pohang Iron & Steel Co., Ltd. The motor capacity is 6000(kW), and it's overload is 250(%).

  • PDF

Maximizing the Efficiency Lifetime Product for Phosphorescent OLEDs

  • Adamovich, Vadim;Kwong, Raymond C.;Weaver, Michael S.;Hack, Mike;Brown, Julie J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.272-276
    • /
    • 2004
  • Great strides in organic light emitting device (OLED) technology have resulted in a number of commercial products. To continue this growth into large area displays, for example televisions, an understanding of the mechanisms that drive the OLED device efficiency and lifetime performance is critical. In this work, we consider maximizing the efficiency lifetime product based on phosphorescent OLED ($PHOLED^{TM}$) technology. We report green PHOLEDs with luminous efficiency of 82 cd/A, 5.7 V and 10,000 hours lifetime at 1,000 cd/$m^2$,red PHOLEDs with CIE of (0.67,0.33), 11 cd/A and 35,000 hours lifetime at 500 cd/$m^2$ and recent progress in blue demonstrating efficiencies of 18 cd/A at 200 cd/$m^2$.

  • PDF

Study on the control conformance testing of IEC 61850 based IED (IEC 61850기반 IED대상 제어 적합성 시험에 관한 연구)

  • Jang, B.T.;Lee, N.H.;Kim, J.H.;Kim, B.H.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.122-124
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project "The verification of Performance of the Substation Automation System and Its Field Test". This paper describes control testing, one of the IEC 61850 conformance testing items, which consists of DO, enhanced DO, SBO and enhanced SBO with a number of test cases.

  • PDF

Diamond Conditioner Wear Characterization for a Copper CMP Process

  • Boruckia, L.;Zhuang, Y.;Kikuma, R.;Rikita, N.;Yamashita, T.;Nagasawa, K.;Lee, H.;Sun, T.;Rosales-Yeomans, D.;Philipossian, A.;Stout, T
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.15-20
    • /
    • 2007
  • Conditioner wear, copper polish rates, pad temperature and coefficient of friction (COF) are measured for two novel Mitsubishi Materials Corporation designs during an extended wear and polishing test. Both designs are coated with a $Teflon^{TM}$ film to reduce substrate wear and chemical attack. Using optical interferometry, changes in the coating that result in gradual changes in diamond exposure are measured. Theories of the COF, conditioning, and polishing are applied to explain the observed performance differences between the designs.

Study on the Report Conformance Test of IEC 61850 based IED (IEC 61850기반 IED 대상 리포트 적합성 시험에 관한 연구)

  • Lee, N.H.;Jang, B.T.;Kim, J.H.;Song, I.J.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.241-242
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project, "The verification of Performance of the Substation Automation System and Its Field Test". This paper presents reporting services of IEC 61850-8-1 and related UCA Test procedures, reporting test items are widely divided into unbuffered report and buffered report and this paper is dealing with unbuffered report.

  • PDF

Performance Verification of IGCT GDU Power Supply System(HFI) for 100MVA STATCOM (100MVA STATCOM IGCT GDU 전원공급장치(HFI) 실증)

  • Han, Young-Seong;Chung, Chung-Choo;Choi, Jong-Yun;Park, Yong-Hee;Suh, In-Young;Yoo, Hyun-Ho;Kim, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.367-368
    • /
    • 2008
  • 한전 전력연구원이 주관하고 (주)효성이 참여하는 협동연구과제로 100MVA STATCOM(Static Compensator)개발이 수행 중에 있다. 100MVA STATCOM의 반도체 스위칭 소자로는 IGCT(Integrated Gate Commutated Thyristor)를 사용하고 있으며 IGCT GDU(Gate Deive Unit)의 전원공급용으로 HFI(High Frequency Inverter)를 사용한다. 본 논문에서는 설계 및 제작된 HFI를 실제 인버터 IGCT GDU전원 공급용으로 적용하여 확인한 성능에 대하여 기술하고 있다.

  • PDF

Development of 1kW Class PEFC System for Residential Applications (1kW급 가정용 연료전지 시스템 실증 연구)

  • Choi, Dong-Min;Shin, Bum-Su;Park, Yon-Goo;Ham, Mi-Sook;Shim, Jae-Hwi
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.174-176
    • /
    • 2008
  • HYOSUNG manufactured and tested 1kw class PEFC systems to generate electrical and thermal energy for each residential usage. In particular, HYOSUNG developed Power conditioning system that performs about 91% electrical conversion ratio specified in 1kW class PEFC systems. Prior to system integration, we tested each performances of components to derive control issues from it. In addition, we have been developing the adequate simulator to describe and predict system performance. In this paper, we verified HYOSUNG's 1kW class PEFC systems are valid for residential energy sureces by testing the characteristics of systems and performances of main component.

  • PDF

A study on the Fire Hazard for the Tracking of RCD through Ground Path at Low Voltage Cabinet Panel (저압분전반에서 접지 경로를 통한 차단기의 트래킹 화재위험성에 관한 연구)

  • Kim, Dong-Ook;Lee, Ki-Yoen;Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.349-352
    • /
    • 2008
  • The electrical accidents result from insulation blackdown due to over voltage and overheating due to the excess of allowable current, deterioration of insulation performance due to the passage of time, and so on. In this paper, the insulating characteristics of phenolic resin using insulating materials for low voltage were analyzed and the tracking test was performed according to IEC Publ. 112.

  • PDF

Consideration on the trial operation of 765kV substation (765kV 변전소 시운전에 관한 고찰)

  • Byun, Gang;Jung, S.H.;Park, K.W.;Lee, S.M.;Choi, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.29-31
    • /
    • 2002
  • Purpose of the 765kV trial operation conducted for the first time in our country are performance verification of domestic developed equipment(765kV M.Tr, GIS,etc) and extraction of problem in advance to commercial operation and cultivation of operation ability. The trial operation of 765kV substation was finished successfully under the positive supports of institutes. manufactures. and constructers. It is expected that extraction of problems in advance and accumulation of operation techniques through the trial operation of 765kV substation will be contributed largly to the realization of the without a hitch operation of 765kV system.

  • PDF