• Title/Summary/Keyword: Corporation Concentration

Search Result 799, Processing Time 0.027 seconds

Electrostatic Discharge and the Minimum Ignition Energy Measurement of Three-Component Flammable Gas Mixtures (정전기(靜電氣) 방전(放電)과 삼성분계(三成分系) 가연성(可燃性) 혼합기체(混合氣體)의 최소점화(最小點火) Energy 측정(測定)에 관한 연구(硏究))

  • Lee, Gwan-Hyung;Choi, Sang-Won;Chung, Jae-Hee;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1819-1823
    • /
    • 1997
  • When flammable gases are mixed with air or oxygen in the explosion concentration range and are ignited by sufficiently large electrostatic discharge energy, they may explode causing severe disaster in workplaces. The minimum ignition energy (MIE) of single gas-air mixtures has been already investigated by many researchers, but the MIE of mixtures of more than three substances is not examined yet. The purpose of this study is to investigate the MIE of several three-component gas mixtures experimentally. The result of our experiment shows that the MIE of some gas mixtures is quite different from that we expected based on the characteristics of individual gas-air mixture.

  • PDF

Point defects and grain boundary effects on tensile strength of 3C-SiC studied by molecular dynamics simulations

  • Li, Yingying;Li, Yan;Xiao, Wei
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.769-775
    • /
    • 2019
  • The tensile strength of irradiated 3C-SiC, SiC with artificial point defects, SiC with symmetric tilt grain boundaries (GBs), irradiated SiC with GBs are investigated using molecular dynamics simulations at 300 K. For an irradiated SiC sample, the tensile strength decreases with the increase of irradiation dose. The Young's modulus decreases with the increase of irradiation dose which agrees well with experiment and simulation data. For artificial point defects, the designed point defects dramatically decrease the tensile strength of SiC at low concentration. Among the point defects studied in this work, the vacancies drop the strength the most seriously. SiC symmetric tilt GBs decrease the tensile strength of pure SiC. Under irradiated condition, the tensile strengths of all SiC samples with grain boundaries decrease and converge to certain value because the structures become amorphous and the grain boundaries disappear after high dose irradiation.

Influence of Heavy Metal on Riparian Vegetation in Downstream Areas of Disused Metal Mines (폐금속광산지역의 하천퇴적물에서 중금속이 식물에 미치는 영향에 관한 연구)

  • Ahn, Tae Woong;Lee, Joung An;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.4
    • /
    • pp.209-218
    • /
    • 2009
  • The purpose of this study was to accumulation of the heavy metals by riparian vegetation throughout analysis of the heavy metal concentration in riparian vegetation, water, and sediment near mine drainage. According to analyzing concentration of the heavy metals in riparian vegetation, water, and sediment the heavy metal was indicated at the leaf significantly. Compared with the concentration of sediment soil, the maximum concentration of the As, Cd, CN, Pb, Zn was higher 2.6, 2.6, 25, non-detect, and 15 times in leaf. Also those concentration have 9.6, 16.6, 25, 1.6, and 25 times in root. As the results, the author can know the sediment has a very relative to vegetation in mine drainage. because, the increasing of concentration of heavy metal in sediment gives the more accumulative concentration of heavy metal in vegetation. Compared with the concentration of conta minated site and non-contaminated site. As, Cd, CN, Pb, Zn the maximum concentration in sediment soil was higher 5.7, 258.1, 10.9, 370.0, and 298.3 times respectively. In case of vegetation, the maximum concentration of the As, Cd, CN, Pb, Zn was higher 5.6, 62.3, 5.0, non-detect, and 30.6 times in leaf. Also those concentration have 8.5, 63.3, 2.6, 60.7, and 62.1 times in root. In this study, the author can surmise that there indicated a lot of adsorption with the heavy metal concentration in contaminated mine drainage.

The Mg Solid Solution far the P-type Activation of GaN Thin Films Grown by Metal-Organic Chemical Vapor Deposition

  • Kim, KeungJoo;Chung, SangJo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.4
    • /
    • pp.24-29
    • /
    • 2001
  • GaN films were grown for various Mg doping concentrations in metal-organic chemical vapor deposition. Below the Mg concentration of 10$^{19}$ ㎤, the thermally annealed sample shows the compensated phase to n-type GaN in Hall measurement. In the MB concentration of 4$\times$10$^{19}$ ㎤ corresponding to the hole carrier concentration of 2.6$\times$1$^{19}$ ㎤ there exists a photoluminescence center of the donor and the acceptor pair transition of the 3.28-eV band. This center is correlated with the defects for a shallow donor of the $V_{Ga}$ and for an acceptor of $Mg_{Ga}$ . The acceptor level shows the binding energy of 0.2-0.25 eV, which was observed by the photon energy of the photocurrent signal of 3.02-3.31 eV. Above the Mg concentration of 4$\times$10$^{19}$ ㎤, both the Mg doping level and Mg concentration were saturated and there Is a photoluminescence center of a deep donor and an acceptor pair transition of the 2.76-eV blue band.

  • PDF

How Skin Care Ingredient Concentrations Can Modulate the Effect of polyols and Oils on Skin Moisturization and Skin Surface Roughness (화장품 원료 중 폴리올, 오일 농도에 따른 피부 보습과 피부 표면 거칠기의 변화)

  • Nam, Gae-Won;Kim, Seung-Hun;Kim, Eun-Joo;Kim, Jin-Han;Chae, Byung-Guen;Lee, Hae-Kwang;Moon, Seong-Joon;Kang, Hak-Hee;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.337-342
    • /
    • 2005
  • The aim of this study was to evaluate the influence of different skin care ingredient concentrations on the effect of polyols and oils on the human skin moisturization and skin surface roughness. Polyols and oils were essential ingredients to make a skin care formulation. But these were still not understood how much concentration(s) were tested on human skin in the aspect of efficacy and sensory. We studied to examine various concentrations of ingredient by cosmetic companies using noninvasive methods. Polyols were composed of glycerol and butylene glycol (BG) as 1:1 ratio, and oils were hydrogenated polydecene, cetyl ethylhexanoate and pentaerythrityl tetraethylhexanoate (PTO(R), Stearinerie Dubois Fils Co., France) as 1:1:1 ratio. All compounds were tested $0{\sim}27%dml$ Polyols and $0{\sim}35%dml$ oils in O/W emulsions. We investigated the effect of water contents and the effect of stratum corneum roughness in forearm skin after application of compounds. Water contents of the skin measured by skin capacitance and skin surface roughness measured visual scoring of skin surface biopsy through the scanning electron microscopy. Water contents of the skin were highly related to amount of polyols (to 20%) and oils (to 12%). Correlation coefficients were 0.971 and 0.985 respectively (p<0.01), 2 h after application. Skin surface roughness was positively correlated with polyol contents in concentration dependent manner, and depend on oils up to 6%. The ratio of coefficient was 2.5 to 1 (polyol to oils) by regression analysis. Further studies will be conducted with other ingredients such as surfactants, lipids and aqueous materials, and with ether methods for noninvasive measurement.

Uncertainty of Online TOC Analyzer in Water Quality Monitoring System (수질자동측정시스템에서 온라인 TOC 자동측정장치의 불확도 산출)

  • Lee, Chung-Yul;Lee, Yong-Woon;Lee, Jun-Hung;Lim, Boung-Jin;Kwon, Young-Jin;Khang, Bum-Ju;Hong, Young-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.193-200
    • /
    • 2007
  • The objective of this study was to estimate uncertainty of online TOC analyzer in water quality monitoring system. A procedure for the estimation of measurement uncertainty of total organic compounds (TOC) based on the ISO approach is presented. It is based on a mathematical model that involves 4 input parameters (standardization, sensitivity, solute effect and representativeness). In this study, a major problem in estimating the uncertainty of online TOC analyzer was the solute effect. It was strongly depends on organic materials. So homogeneity of the sample is the most important consideration. Modified concentration and combined standard uncertainty was $4.71{\pm}0.36$ mg $L^{-1}$ by model modified in this study.

Simple Analytical Method for Acrylamide in the Workplace Air Adsorbed by Charcoal Tube (활성탄관을 사용하여 포집한 작업환경 공기중 아크릴아마이드의 분석법)

  • Yang, J.S.;Lee, M.Y.;Park, I.J.;Kang, S.K.
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 1998
  • For the ambient monitoring of acrylamide, the adequate condition of sampling and analysis was checked. The adequate adsorbents and desorption solvents were tested. The combination of charcoal tube as a adsorbent and acetone as a desorption solvent showed 87% desorption efficiency. Flame ionization detector was used to detect acrylamide. The detection limit was 0.814 mg acrylamide in 1 L acetone. It is the equivalent concentration of 0.0203 mg acrylamide in $1m^3$ air if the volume of air collected was 40L. The permissible exposure level (PEL) of acrylamide in the workplace air recommended by Occupational Safety and Health Administration (OSHA, USA) is 0.3 mg acrylamide in $1m^3$ air. So, it is very simple and economic analytical method for acrylamide to be set in the industrial hygiene laboratories.

  • PDF

Study on the Acute and Sub-Acute Inhalation Toxicity of 1-Bromopropane in SD Rats (Rat를 이용 1-Bromopropane의 급성 및 아급성 흡입독성 연구)

  • Kim, Hyeon-Yeong;Jeong, Jae-Hwang;Chung, Yong-Hyun;Lee, Yong-Muk;Sur, Gil-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.272-288
    • /
    • 1998
  • The purpose of this study was to investigate the acute(4 hrs) and repeated-dose(6 hrs a day, 5 days a week, 8 weeks) toxic effects of 1-bromopropane(1-BP) on Sprague-Dawley (SD) rats which were treated by inhalation. The results were as follows ; 1. The median lethal concentration($LC_{50}$) was estimated 14,374 ppm(confidence limit 95% ; 13,624~15,596 ppm) in acute inhalation. Abnormal clinical signs related to the 1-BP were not observed with the acute inhalation dose. Gross findings of necropsy revealed no evidence of specific toxicity related to the 1-BP. 2. By sub-acute inhalation the body weights of male and female were significantly reduced(p<0.001) by the dose of 1,800 ppm compared with control group, while the relative weights of liver were significantly increased(p<0.001) in both sexes. However there were no significant variation in food consumption, urine biochemistry, hematology and blood biochemistry for the exposed rats compared with the control rats. Abnormal clinical signs and gross findings of necropsy related to the 1-BP were not shown. No toxicologic lesions were observed by the histopathological test.

  • PDF

Estimation of Suspended Sediment Load in Imha-Andong Watershed using SWAT Model (SWAT 모델을 이용한 임하.안동 유역의 부유사량 발생량 추정)

  • Kim, Jeong-Kon;Son, Kyong-Ho;Noh, Joon-Woo;Lee, Sang-Uk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1209-1217
    • /
    • 2008
  • For efficient turbid water management a SWAT model was established for the Imha-Andong watershed where serious turbid water problems have frequently occurred. To evaluate soil loss combined with rainfall runoff process, the analysis focused on comparing the daily runoff discharge and concentration of suspended sediment (SS) using measured data sets. The results of annual SS load analysis for each sub-basin using the calibrated model showed that in the entire target watershed the soil loss ranged from 0.7 to 5.9 tons/ha in year 2005 and from 3.0 to 34.0 tons/ha in year 2003 when the typhoon 'Maemi' severly affected the area. In the future, it is suggest to increase model simulation accuracies supported by a long-term and extensive monitoring to enhance basin-wide suspended sediment estimation and management.

Uncertainty of Peroxide Value Determination in Fat in Follow up Formula (성장기용 조제식에 함유된 유지성분의 과산화물가 측정불확도)

  • Kim, Sung-Han;Kwack, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.885-892
    • /
    • 2004
  • Peroxide values (PV) of fat from fallow up formula were determined using redox-potentiometric titration method and standard method, which is based on KI oxidation by hydroperoxides and volumetric titration of liberated iodine, and their uncertainties were compared. Uncertainty sources in measurement, such as sample weight, sodium thiosulfate concentration, and titer, were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement and Draft EURACHEM/CITAC Guide. Analytical results and combined standard uncertainties of peroxide values (PV) determined by standard burette and potentiometric titrations were $2.05{\pm}0.17\;and\;1.96{\pm}0.07\;meq/kg$, respectively, suggesting potentiometric titration method is suitable for determining PV of fat with low PV, because uncertainty of PV determination obtained by potentiometric titration was lower than that obtained by burette titration.