• 제목/요약/키워드: Coronary CT angiography

검색결과 56건 처리시간 0.026초

Valve-Sparing Root Replacement in a Turner Syndrome Patient with Bicuspid Aortic Valve and Juxtacommissural Origin of the Right Coronary Artery: A Case Report

  • Son, Dong Hyeon;Cho, Sungkyu;Song, Mi Kyoung
    • Journal of Chest Surgery
    • /
    • 제55권5호
    • /
    • pp.413-416
    • /
    • 2022
  • A 32-year-old woman diagnosed with Turner syndrome presented to the hospital for an evaluation of cardiovascular complications. Preoperative computed tomography (CT) and echocardiography showed progression of aortic root and ascending aorta dilatation, as well as a bicuspid aortic valve. There was no evidence of aortic regurgitation. We planned valve-sparing aortic root replacement and ascending aorta replacement with a high risk of aortic rupture. Intraoperatively, we incidentally found a juxtacommissural origin of the right coronary artery (RCA). We performed aortic valve reimplantation using a graft designed with a key-shaped hole to wrap the juxtacommissural-origin RCA by modifying the Florida sleeve technique. Coronary blood flow was patent on postoperative CT angiography, and there was no evidence of aortic regurgitation on postoperative echocardiography. The patient was discharged from the hospital on postoperative day 7 without any complications.

관상동맥검사에서 선량과 화질에 관한 연구 (Effects of Radiation Dose and Image Quality at the Coronary Angiography)

  • 류명송;최남길;한재복;양숙;이종호
    • 한국콘텐츠학회논문지
    • /
    • 제12권4호
    • /
    • pp.367-372
    • /
    • 2012
  • 본 연구는 체질량지수에 따른 관전압(kVp)과 관전류량(mAs)의 변화에서 선량과 화질의 연관성을 알아보고자 하였다. 실험대상군은 A군(100 kVp, 240 mAs, N=20), B군(120 kVp, 240 mAs, N=20), C군(100 kVp, 270 mAs, N=20), D군(120 kVp, 270 mAs, N=20)으로 나누어 관전류량의 변화에 관계된 화질을 평가하였다. 실험대상군에 대한 화질평가는 4점 척도를 사용하여 very good 4점, good 3점, fair 2점, poor 1점 등급으로 나누어 평가하였고, 피폭선량은 DLP(dose length product)를 이용하여 평가하였다. 결론적으로 100 kVp에서는 5.6 $mGy{\cdot}cm$, 120 kVp에서는 11 $mGy{\cdot}cm$, 정도 낮은 선량을 보였고 통계적으로 유의한 차이를 보였다(p<0.05). 하지만 화질평가에서도 통계적으로 유의한 차이가 없었으며 진단적 가치가 동등한 영상을 획득하였다(p>0.05). 따라서 CT 관상동맥조영술 검사에서는 사전에 체질량지수(body mass index)을 고려하여 검사조건을 적절하게 선택하는 것이 환자의 피폭선량을 줄이면서 최적의 화질을 획득할 수 있을 것이라 사료된다.

반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험 (Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols)

  • 하성민;정성희;장혁재;박은아;심학준
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.28-35
    • /
    • 2015
  • 본 논문에서는 반복적 구성 기법과 관전류 노출자동조절 기법이 영상의 화질과 방사선량에 미치는 영향을 관상동맥 전산화단층촬영 혈관조영 영상(coronary computed tomography angiography, CCTA)을 대상으로 팬텀 실험에 기반하여 평가하고자 한다. 이를 위하여 미국 의학물리학회(American Association of Physics in Medicine) 표준의 성능 평가 팬텀을 320 다중검출열 CT로써 촬영하였다. 80 kVp, 100 kVp, 120 kVp의 관전압에 있어서, 관전류 노출자동조절 기법은 저선량 목표 표준편차(SD=44)와 고선량(목표 표준편차=33)의 두 가지 설정으로써 촬영하였다. 재구성 변수로서는 필터보정 역투영(FBP)와 반복적 재구성 방법을 설정하여, 전부 12개의 재구성 영상을 획득하였다(12=3 (80, 100, 120 kVp)${\times}2$ (저선량(목표SD=44), 고선량(목표SD=33))${\times}2$ (필터보정역투영, 반복적 재구성). 영상의 화질은 잡음의 세기(표준편차), 변조전달함수, 대조대잡음비(CNR)에 의하여 평가하였으며, 관전압과 관전류 노출자동조절 기법에서의 목표 선량과 대소 및 재구성 기법의 선택이 화질과 방사선량에 미치는 영향을 관찰하였다. 반복적 재구성 기법은 필터보정역투영 기법보다 영상 잡음을 대폭 감소시켰으며 이는 저선량의 경우 더욱 뚜렷하였다. 즉, 잡음의 세기는 관전류 노출자동조절의 설정이 고선량 (목표SD=33)과 저선량(목표SD=44)인 경우, 각각 평균 38%와 평균 46% 감소하였다. 반복적 재구성 기법에 의하여, 변조전달 함수에 의한 공간적 해상도의 평가에 있어서 미약한 감소를 보였으나, 이로써 잡음 저감과 대조대잡음비(CNR)에 있어서의 현저한 개선을 상쇄할 정도의 영향에는 미치지 못 하였다. 결과적으로, 관상동맥 전산화단층촬영 혈관조영 영상의 획득에서 있어서, 반복적 재구성 기법과 관전류 노출자동조정 기법을 동시에 사용하는 것은 영상의 화질을 개선하면서 공간적 해상도의 저하 등 그 부작용은 최소화함으로써, 합리적으로 획득 가능한 한 최소한의 선량 (ALARA)의 원칙에 충실한 실제 임상적 효과를 의미한다고 기대할 수 있다.

관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가 (The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography)

  • 최남길;최재성;한재복
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4411-4417
    • /
    • 2010
  • 64채널 MDCT(multidetector computed tomography)와 128채널 DSCT(dual source computed tomography)를 이용한 관상동맥 전산화단층촬영 시 유효선량과 획득한 영상의 질을 평가함으로서 임상에서의 유용성을 평가하고자 하였다. 피폭선량은 선량길이곱(dose length product: DLP)에 흉부 조직의 가중치(0.017)을 곱하여 유효선량(mSv)으로 계산하였으며, 영상 평가는 심장촬영검사 후 영상의학과 전문의가 5점 Likert 척도(5점 최상)로 평가하였다. DLP 값은 64 채널 MDCT에서는 $851{\sim}1277\;mGy{\cdot}cm$ (평균 유효선량: 17.23mSv), 128 채널 DSCT에서는 $82{\sim}110\;mGy{\cdot}cm$ (평균 유효선량: 1.58mSv)로 각각 분포하였다. 영상 평가점수는 64 채널 MDCT에서 $3.31{\pm}0.62$(4점 이상 34명), 128channel DSCT에서 $4.05{\pm}0.46$(4점 이상 96명)으로 각각 나타났다. 유효선량은 64채널 MDCT에 비해 128채널 DSCT가 1/10 이상 감소함을 알 수 있었다. 영상 평가점수는 통계적으로 유의한 차이를 보였으며 4점 이상 점수의 빈도는 128채널 DSCT에서 2.8배 높게 나타났다. 결론적으로 관상동맥 전산화단층촬영검사에서는 128채널 DSCT가 64채널 MDCT에 비해 환자가 받는 유효선량은 감소하고 영상 평가점수는 높게 나타나 임상에서 보다 유용할 것으로 판단된다.

64-slice single source CT와 128-slice dual source CT를 이용한 관상동맥 조영 검사 시 환자선량 비교 (Comparison of Radiation Doses between 64-slice Single Source and 128-slice Dual Source CT Coronary Angiography in patient)

  • 강영한
    • 한국방사선학회논문지
    • /
    • 제6권2호
    • /
    • pp.129-136
    • /
    • 2012
  • 본 연구는 64-절편 단선원 CT(SSCT)와 128-절편 이중선원(DSCT)을 이용한 관상동맥조영 CT 검사 시 방사선량에 대해 알아보고, 이 선량으로 인한 암 발생의 잠재적 위험(LAR)을 평가해 보았다. SSCT의 후향적동조화(RGH)스캔의 유효선량은 13.86 mSv 이었고, DSCT의 RGH 스캔의 유효선량은 11.87 mSv 이었다. DSCT의 전향적동조화 (PGT) 스캔 중 선량변조를 적용치 않은 모드의 유효선량은 5.61 mSv, 선량변조를 적용하였을 때는 3.04 mSv 이었다. 1회 스캔하는 FLASH 모드는 0.98 mSv 이었다. SSCT의 RGH 스캔의 LAR은 1,176명 중 1명, DSCT의 RGH에서는 1,960명 중 1명이었다. DSCT의 PGT는 3,030명 중 1명, 선량변조를 하면 5,882명 중 1명에서 발암 위험이 있었다. 따라서 SSCT와 DSCT를 이용한 관상동맥조영 CT 검사는 암발생 귀속위험과 관련성이 있음을 인지하여야 하고, 환자선량을 줄이기 위해 RGH보다 PGT, FLASH 등의 프로토콜을 적용하는 것이 필요하다.

개인용 컴퓨터를 이용한 기능 유관성 관상동맥 협착증의 삼차원 심장스펙트 사진과 64채널 전산화 단층 혈관촬영사진과의 융합 (Fusion of 3D Cardiac SPECT and 64-Channel-CT Angiography Using Personal Computer in Functionally Relevant Coronary Artery Stenosis)

  • 박용휘
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.252-254
    • /
    • 2007
  • Image fusion is fast catching attention as Wagner pointed out in his 2006 version of the recent progress and development presented at the annual meeting of Society of Nuclear Medicine. Prototypical fusion of bone scan and radiograph was already attempted at in 1961 when Fleming et al. published an article on strontium-85 bone scan. They simply superimposed dot scan on radiograph enabling simultaneous assessment of altered bone metabolism and local bone anatomy. Indeed the parallel reading of images of bone scan and radiography, CT, MRI or ultrasonography has been practiced in nuclear medicine long since. It is fortunate that recent development of computer science and technology along with the availability of refined CT and SPECT machines has permitted us to open a new avenue to digitally produce precise fusion image so that they can readily be read, exchanged and disseminated using internet. Ten years ago fusion was performed using Bresstrahlung SPECT/CT and it is now achievable by PET/CT and SPECT/CT software and SPECT/CT hardware. The merit of image fusion is its feasibility of reliable assessment of morphological and metabolic change. It is now applicable not only to stationary organs such as brain and skeleton but also to moving organs such as the heart, lung and stomach. Recently, we could create useful fusion image of cardiac SPECT and 64-channel CT angiograph. The former provided myocardial metabolic profile and the latter vascular narrowing in two patients with coronary artery stenosis and myocardial ischemia. Arterial stenosis was severe in Case 1 and mild in Case 2.

Evaluation of the Ostium in Anomalous Origin of the Right Coronary Artery with an Interarterial Course Using Dynamic Cardiac CT and Implications of Ostial Findings

  • Jin-Young Kim;Yoo Jin Hong;Kyunghwa Han;Suji Lee;Young Jin Kim;Byoung Wook Choi;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.172-179
    • /
    • 2022
  • Objective: We aimed to evaluate the ostium of right coronary artery of anomalous origin from the left coronary sinus (AORL) with an interarterial course throughout the cardiac cycle on CT and analyze the clinical significance of the ostial findings. Materials and Methods: From January 2011 to December 2015, 68 patients (41 male, 57.3 ± 12.1 years) with AORL with an interarterial course and retrospective cardiac CT data were included. AORL was classified as high or low ostial location based on the pulmonary annulus in the diastolic and systolic phases on cardiac CT. In addition, the height, width, height/width ratio, area, and angle of the ostium were measured in both cardiac phases. After cardiac CT, patients were followed until December 31, 2020 for major adverse cardiac events (MACE). Clinical and CT characteristics associated with MACE were explored using Cox regression analysis. Results: During a median follow-up period of 2071 days (interquartile range, 1180.5-2747.3 days), 13 patients experienced MACE (19.1%, 13/68). Seven (10.3%, 7/68) had the ostial location change from high in the diastolic phase to low in the systolic phase. In the univariable analysis, younger age (hazard ratio [HR] = 0.918, p < 0.001), high ostial location (HR = 4.008, p = 0.036), larger height/width ratio (HR = 5.621, p = 0.049), and smaller ostial angle (HR = 0.846, p = 0.048) in the systolic phase were significant predictors of MACE. In multivariable cox regression analysis, younger age (adjusted HR = 0.917, p = 0.002) and high ostial location in the systolic phase (adjusted HR = 4.345, p = 0.026) were independent predictors of MACE. Conclusion: The ostial location of AORL with an interarterial course can change during the cardiac cycle, and high ostial location in the systolic phase was an independent predictor of MACE.

3차원 관상동맥의 위상적인 형상분석을 위한 골격 추출 (Skeleton Extraction of 3D Coronary Artery for Topological Shape Analysis)

  • 이재진;김정식;최수미
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 가을 학술발표논문집 Vol.32 No.2 (1)
    • /
    • pp.700-702
    • /
    • 2005
  • 3차원 관상동맥처럼 위상 구조가 중요한 객체의 형상을 분석하기 위해서는 혈관의 분기점, 극단점, 혈관의 계층적 구조 관계 등의 정보를 함축적으로 표현할 수 있는 골격 추출이 매우 중요하다 본 논문에서는 3차원 CT 혈관조영술(3D CT Angiography)로 촬영된 영상으로부터 관상동맥의 3차원 골격을 추출하는 방법을 개발하였다. 먼저, CT 혈관조영술부터 획득한 슬라이스 이미지로부터 3차원 조작 및 수술 시뮬레이션 등을 위하여 혈관의 3차원 표면에 대한 메쉬 모델을 생성한다. 생성된 메쉬 모델이 임의로 변형된 후에도 자동으로 골격을 쉽게 추출할 수 있도록 메쉬 모델을 복셀화하는 단계를 거친다. 이렇게 얻어진 복셀모델로부터 유클리디언 거리 맵을 구성하여 discrete medial surface (DMS)을 생성하고 최종적으로 골격을 추출하게 된다. 이렇게 추출된 3차원 골격은 관상동맥 수술 시뮬레이션 등에서 다양한 형상 분석에 유용하게 사용될 수 있다.

  • PDF

거대 우관상 동맥류를 동반한 우관상 동맥에서 좌심실로 유출되는 관상 동맥루 - 1예 보고 - (Right Coronary Artery to Left Ventricular Fistula with a Giant Right Coronary Artery Aneurysm - A case report -)

  • 강준규;허재학;장지민;송철민
    • Journal of Chest Surgery
    • /
    • 제43권3호
    • /
    • pp.296-299
    • /
    • 2010
  • 거대 우관상 동맥류를 동반한 우관상 동맥에서 좌심실로 유출되는 관상 동맥루는 매우 드문 질환이며 동맥류 파열과 심부전, 심내막염으로의 진행 가능성이 있으므로 수술적 치료가 요구되는 질환이다. 본 증례는 47세 남자 환자가 3개월 전부터 시작된 운동 시 호흡 곤란을 주소로 내원한 환자로 흉부 전산화 단층 촬영과 관상동맥 조영술을 통해 거대 우관상동맥류 및 관상동맥-좌심실루로 진단되어 거대 관상동맥류 절제술 및 관상동맥 우회술을 시행하여 성공적으로 치험하였기에 보고하는 바이다.

Microvascular Myocardial Ischemia in Patients With Diabetes Without Obstructive Coronary Stenosis and Its Association With Angina

  • Yarong Yu;Wenli Yang;Xu Dai;Lihua Yu;Ziting Lan;Xiaoying Ding;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제24권11호
    • /
    • pp.1081-1092
    • /
    • 2023
  • Objective: To investigate the incidence of microvascular myocardial ischemia in diabetic patients without obstructive coronary artery disease (CAD) and its relationship with angina. Materials and Methods: Diabetic patients and an intermediate-to-high pretest probability of CAD were prospectively enrolled. Non-diabetic patients but with an intermediate-to-high pretest probability of CAD were retrospectively included as controls. The patients underwent dynamic computed tomography-myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) to quantify coronary stenosis, myocardial blood flow (MBF), and extracellular volume (ECV). The proportion of patients with microvascular myocardial ischemia, defined as any myocardial segment with a mean MBF ≤ of 100 mL/min/100 mL, in patients without obstructive CAD (Coronary Artery Disease-Reporting and Data System [CAD-RADS] grade 0-2 on CCTA) was determined. Various quantitative parameters of the patients with and without diabetes without obstructive CAD were compared. Multivariable analysis was used to determine the association between microvascular myocardial ischemia and angina symptoms in diabetic patients without obstructive CAD. Results: One hundred and fifty-two diabetic patients (mean age: 59.7 ± 10.7; 77 males) and 266 non-diabetic patients (62.0 ± 12.3; 167 males) were enrolled; CCTA revealed 113 and 155 patients without obstructive CAD, respectively. For patients without obstructive CAD, the mean global MBF was significantly lower for those with diabetes than for those without (152.8 mL/min/100 mL vs. 170.4 mL/min/100 mL, P < 0.001). The mean ECV was significantly higher for diabetic patients (27.2% vs. 25.8%, P = 0.009). Among the patients without obstructive CAD, the incidence of microvascular myocardial ischemia (36.3% [41/113] vs. 10.3% [16/155], P < 0.001) and interstitial fibrosis (69.9% [79/113] vs. 33.3% [8/24], P = 0.001) were significantly higher in diabetic patients than in the controls. The presence of microvascular myocardial ischemia was independently associated with angina symptoms (adjusted odds ratio = 3.439, P = 0.037) in diabetic patients but without obstructive CAD. Conclusion: Dynamic CT-MPI + CCTA revealed a high incidence of microvascular myocardial ischemia in diabetic patients without obstructive CAD. Microvascular myocardial ischemia is strongly associated with angina.