• Title/Summary/Keyword: Coronary CT angiography

Search Result 56, Processing Time 0.035 seconds

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Findings on Chest Low-Dose CT Images of Group Exposed to Inorganic Dusts (분진에 노출되었던 집단의 흉부 저선량 CT영상 소견)

  • Lee, Won-Jeong;Seon, Jong-Ryul;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.305-314
    • /
    • 2011
  • The purpose of this study was to compare the findings on the chest low-dose CT (LDCT) images between the negative and positive groups for pneumoconiosis in the group exposed to inorganic dust. From May 30, 2007 to August 31, 2008, total 328 subjects were examined by a LDCT. LDCT images were read by a chest radiologist who has much experience for reading of pneumoconiosis. All subjects were classified into two groups based on digital images after consensus reading of two radiologists according to the ILO 2000 guidelines; negative group (87, 26.5%) without pneumoconiosis and positive group (241, 73.5%). Statistical analysis was performed using a SPSS 14.0. There were significant differences in age (60.9 vs. 65.0, p<0.001), and in dust expose duration (17.0 vs. 19.2, p=0.024) between two groups, but no significant difference in smoking (p=0.784). Of the 328 subjects, 13 diagnosis were extracted from 245 subjects (74.7%). Coronary artery calcification (CAC) was significantly higher in positive group than that in negative group (36.9% vs. 25.3%, p=0.049). Honeycombing showed higher frequency in positive group than in negative group (6.2% vs. 1.2%, p=0.079). Pneumoconiosis findings caused by inorganic dusts exposure showed the significant relation with CAC on LDCT images. Future studies need to prove that pneumoconiosis finding is independent risk factor for CAC using a coronary artery angiography.

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction

  • Chuluunbaatar Otgonbaatar;Jae-Kyun Ryu;Jaemin Shin;Ji Young Woo;Jung Wook Seo;Hackjoon Shim;Dae Hyun Hwang
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1044-1054
    • /
    • 2022
  • Objective: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. Materials and Methods: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods. Results: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR. Conclusion: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.

The Effect of Attenuation Correction with CT on the Interpretation of Myocardial Perfusion SPECT: in Patients with Normal Coronary Angiogram (관상동맥조영술상 정상소견을 보인 환자에서 전산화단층촬영술(CT)를 이용한 감쇠보정이 심근관류 SPECT의 판독에 미치는 영향)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Hyung-Woo;Hong, Geu-Ru;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.246-251
    • /
    • 2005
  • Purpose: There has been many reports for the effect of attenuation correction on myocardial perfusion SPECT. We studied the effect of attenuation correction with CT (computed tomography) in patients with normal coronary angiography. Materials and Methods: Fifteen patients with normal coronary artery on angiography and low likelihood of coronary artery disease were enrolled in this study (male: 6, female: 9, mean age: $58{\pm}8$ year). Myocardial perfusion SPECT was done with Millennium VG with Hawkeye device (GE, SPECT/CT camera). A visual analysis and polar map quantification (Emory tool box) was performed. In quantitative analysis, percent uptake of each myocardial wall on polar map (percent of maximal uptake) was compared between non-corrected (NC) and corrected (AC) images. Results: Visual analysis showed AC images led to an increase of uptake in the inferior wall, but decrease of uptake in the anterior wall, apex and septum. liver activity is also increased in AC images. In quantitative analysis, the percent uptake is decreased in the anterior wall, apex and septum, but increased in the inferior wall. It is helpful to interpret the images in the inferior wall after AC, but difficult in the apex and anterior wall after AC. Conclusion: AC is helpful in the inferior wall. But in the apex or anterior wall, AC must be carefully applied to normal perfused myocardium.

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

CT-Based Leiden Score Outperforms Confirm Score in Predicting Major Adverse Cardiovascular Events for Diabetic Patients with Suspected Coronary Artery Disease

  • Zinuan Liu;Yipu Ding;Guanhua Dou;Xi Wang;Dongkai Shan;Bai He;Jing Jing;Yundai Chen;Junjie Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.939-948
    • /
    • 2022
  • Objective: Evidence supports the efficacy of coronary computed tomography angiography (CCTA)-based risk scores in cardiovascular risk stratification of patients with suspected coronary artery disease (CAD). We aimed to compare two CCTA-based risk score algorithms, Leiden and Confirm scores, in patients with diabetes mellitus (DM) and suspected CAD. Materials and Methods: This single-center prospective cohort study consecutively included 1241 DM patients (54.1% male, 60.2 ± 10.4 years) referred for CCTA for suspected CAD in 2015-2017. Leiden and Confirm scores were calculated and stratified as < 5 (reference), 5-20, and > 20 for Leiden and < 14.3 (reference), 14.3-19.5, and > 19.5 for Confirm. Major adverse cardiovascular events (MACE) were defined as the composite outcomes of cardiovascular death, nonfatal myocardial infarction (MI), stroke, and unstable angina requiring hospitalization. The Cox model and Kaplan-Meier method were used to evaluate the effect size of the risk scores on MACE. The area under the curve (AUC) at the median follow-up time was also compared between score algorithms. Results: During a median follow-up of 31 months (interquartile range, 27.6-37.3 months), 131 of MACE were recorded, including 17 cardiovascular deaths, 28 nonfatal MIs, 64 unstable anginas requiring hospitalization, and 22 strokes. An incremental incidence of MACE was observed in both Leiden and Confirm scores, with an increase in the scores (log-rank p < 0.001). In the multivariable analysis, compared with Leiden score < 5, the hazard ratios for Leiden scores of 5-20 and > 20 were 2.37 (95% confidence interval [CI]: 1.53-3.69; p < 0.001) and 4.39 (95% CI: 2.40-8.01; p < 0.001), respectively, while the Confirm score did not demonstrate a statistically significant association with the risk of MACE. The Leiden score showed a greater AUC of 0.840 compared to 0.777 for the Confirm score (p < 0.001). Conclusion: CCTA-based risk score algorithms could be used as reliable cardiovascular risk predictors in patients with DM and suspected CAD, among which the Leiden score outperformed the Confirm score in predicting MACE.

Bilateral Vertebral Artery Dissecting Aneurysms Presenting with Subarachnoid Hemorrhage Treated by Staged Coil Trapping and Covered Stents Graft

  • Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.155-159
    • /
    • 2012
  • The treatment of bilateral vertebral artery dissecting aneurysms (VADAs) presenting with subarachnoid hemorrhage (SAH) is still challenging. The authors report a rare case of bilateral VADA treated with coil trapping of ruptured VADA and covered stents implantation after multiple unsuccessful stent assisted coiling of the contralateral unruptured VADA. A 44-year-old woman was admitted to our hospital because of severe headache and sudden stuporous consciousness. Brain CT showed thick SAH and intraventricular hemorrhage. Cerebral angiography demonstrated bilateral VADA. Based on the SAH pattern and aneurysm configurations, the right VADA was considered ruptured. This was trapped with endovascular coils without difficulty. One month later, the contralateral unruptured VADA was protected using a stent-within-a-stent technique, but marked enlargement of the left VADA was detected by 8-months follow-up angiography. Subsequently two times coil packing for pseudosacs resulted in near complete occlusion of left VADA. However, it continued to grow. Covered stents graft below the posterior inferior cerebellar artery (PICA) origin and a coronary stent implantation across the origin of the PICA resulted in near complete obliteration of the VADA. Covered stent graft can be used as a last therapeutic option for the management of VADA, which requires absolute preservation of VA flow.

Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography

  • Masuda, Takanori;Nakaura, Takeshi;Funama, Yoshinori;Sato, Tomoyasu;Higaki, Toru;Kiguchi, Masao;Matsumoto, Yoriaki;Yamashita, Yukari;Imada, Naoyuki;Awai, Kazuo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1021-1030
    • /
    • 2018
  • Objective: We evaluated the effect of various patient characteristics and time-density curve (TDC)-factors on the test bolus-affected vessel enhancement on coronary computed tomography angiography (CCTA). We also assessed the value of generalized linear regression models (GLMs) for predicting enhancement on CCTA. Materials and Methods: We performed univariate and multivariate regression analysis to evaluate the effect of patient characteristics and to compare contrast enhancement per gram of iodine on test bolus (${\Delta}HUTEST$) and CCTA (${\Delta}HUCCTA$). We developed GLMs to predict ${\Delta}HUCCTA$. GLMs including independent variables were validated with 6-fold cross-validation using the correlation coefficient and Bland-Altman analysis. Results: In multivariate analysis, only total body weight (TBW) and ${\Delta}HUTEST$ maintained their independent predictive value (p < 0.001). In validation analysis, the highest correlation coefficient between ${\Delta}HUCCTA$ and the prediction values was seen in the GLM (r = 0.75), followed by TDC (r = 0.69) and TBW (r = 0.62). The lowest Bland-Altman limit of agreement was observed with GLM-3 (mean difference, $-0.0{\pm}5.1$ Hounsfield units/grams of iodine [HU/gI]; 95% confidence interval [CI], -10.1, 10.1), followed by ${\Delta}HUCCTA$ ($-0.0{\pm}5.9HU/gI$; 95% CI, -11.9, 11.9) and TBW ($1.1{\pm}6.2HU/gI$; 95% CI, -11.2, 13.4). Conclusion: We demonstrated that the patient's TBW and ${\Delta}HUTEST$ significantly affected contrast enhancement on CCTA images and that the combined use of clinical information and test bolus results is useful for predicting aortic enhancement.

Sternal Healing after Coronary Artery Bypass Grafting Using Bilateral Internal Thoracic Arteries: Assessment by Computed Tomography Scan

  • Shin, Yoon Cheol;Kim, Sue Hyun;Kim, Dong Jung;Kim, Dong Jin;Kim, Jun Sung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.48 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • Background: This study aimed to investigate sternal healing over time and the incidence of poor sternal healing in patients undergoing coronary artery bypass graft (CABG) surgery using bilateral internal thoracic arteries. Methods: This study enrolled 197 patients who underwent isolated CABG using skeletonized bilateral internal thoracic arteries (sBITA) from 2006 through 2009. Postoperative computed tomography (CT) angiography was performed on all patients at monthly intervals for three to six months after surgery. In 108 patients, an additional CT study was performed 24 to 48 months after surgery. The axial CT images were used to score sternal fusion at the manubrium, the upper sternum, and the lower sternum. These scores were added to evaluate overall healing: a score of 0 to 1 reflected poor healing, a score of 2 to 4 was defined as fair healing, and a score of 5 to 6 indicated complete healing. Medical records were also retrospectively reviewed to identify perioperative variables associated with poor early sternal healing. Results: Three to six months after surgery, the average total score of sternal healing was $2.07{\pm}1.52$ and 68 patients (34.5%) showed poor healing. Poor healing was most frequently found in the manubrium, which was scored as zero in 72.6% of patients. In multivariate analysis, the factors associated with poor early healing were shorter post-surgery time, older age, diabetes mellitus, and postoperative renal dysfunction. In later CT images, the average sternal healing score improved to $5.88{\pm}0.38$ and complete healing was observed in 98.2% of patients. Conclusion: Complete sternal healing takes more than three months after a median sternotomy for CABG using sBITA. Healing is most delayed in the manubrium.

A Case of Coronary-Pulmonary Artery Fistula (관상동맥-폐동맥 누공 1예)

  • Lee, Kyung Hae;Wang, Joon Kwang;Shin, Sung Joon;Kim, Mi Ok;Kim, Tae Hyung;Son, Jang Won;Yun, Ho Ju;Shin, Dong Ho;Park, Sung Soo;Kim, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.4
    • /
    • pp.420-425
    • /
    • 2004
  • Fistula between coronary artery and pulmonary artery is a type of coronary artery anomalies. It can cause atypical chest pain and fatigue, angina pectoris, endocarditis, finally myocardial steal can result in heart failure and myocardial infarction. But only 0.1-0.2% of coronary angiographic studies reveal the communications between coronary artery and other spaces. (heart chamber, pulmonary artery etc.) It is frequently congenital, but acquired types are increasing because chest and heart manipulations such as opertion of tetralogy of Fallot, endomyocardial biopsy, radiation therapy, or penetrating blunt trauma are increasing. There are reports about repair of fistula using thrombogenic tips, coil embolization and surgical intervention. We report a connection between coronary artery and pulmonary artery in 79 years old female. She was 30 pack-years smoker and suffered from dyspnea several years with chronic obstructive pulmonary disease. She presented with atypical chest pain and palpitation after admission. Electrocardiography showed ST-T wave abnormality. Emergency coronary angiography and chest CT scan revealed coronary-pulmonary artery fistula. Transcatheter embolization was performed and she was relieved from discomforts.