• Title/Summary/Keyword: Coronal plane

Search Result 139, Processing Time 0.025 seconds

Intrarater and Interrater Reliability of the Lateral Scapular Slide Test in Patients with Chronic Shoulder Pain (만성 견부통 환자를 대상으로 한 측방 견갑골 활주 검사의 측정자내 및 측정자간 신뢰도)

  • Park, Young-Seok;Kim, Suhn-Yeop;Seo, Young-Joo;Kim, Taek-Yean
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.32-40
    • /
    • 2009
  • Purpose: The purposes of this study were to determine the intertester and intratester reliabilities of the Lateral Scapular Slide Test (LSST) method, and to examine if significant differences existed in scapular positions among the pain groups (right-shoulder pain group, left-shoulder, pain group and both-shoulders pain group). 27 female subjects (mean age = 51.6, mean height = 157.7 cm, mean weight = 57.5 kg) with shoulder pain were recruited for this study. Methods: The bilateral distances between the root of the scapular spine and T3/4 (RSS), and between the inferior scapular angle and T7/8 (IA), were recorded. Subjects were tested at three positions: the with arms with abducted at 0, 45 and 90 degrees in the coronal plane. The LSST measurements were performed by two testers, selected randomly. Results: The results were as follows: Intraclass correlation coefficients (ICCs) for the intertester reliability were excellent (ICC 0.78-0.94). And the ICCs for the intratester reliability were excellent (ICC 0.83-0.99). In the right-shoulder and both-shoulders pain groups, the right-side RSS and IA values of right side were significantly greater than of the left-side RSS values left side for the arms abducted at 0 degrees of right shoulder pain group and both shoulder pain group (p<.05). However, the side-to-side difference was less than 1.5 cm. Conclusion: Our results suggest that the LSST is highly reliable in identifying the abnormal scapular position of patients with shoulder problems. Future research should be continued to clarify the clinical usefulness of this method.

  • PDF

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).

Effects of Mobilization With Movement Using Posterior Talus Glide Taping Added Myofascial Release on Kinematic Data of Dynamic Balance in Individuals With Calf Shortening (종아리근 단축 대상자에게 목말뼈 후방활주 테이핑을 이용한 관절가동술 적용과 근막이완기법의 적용이 동적 균형의 운동학적 변화에 미치는 영향)

  • Seo, Min-A;Jeong, Kyu-Na;Kim, Yu-Jin;Lee, Yu-Jin;Hwang, Young-In
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.70-78
    • /
    • 2022
  • Background: Individuals with calf muscle shortening may have decreased dynamic balance. Objects: This study aimed to investigate the effect of mobilization with movement (MWM) and myofascial release (MFR) on kinematic changes in dynamic balance in individuals with calf muscle shortening. Methods: Thirteen participants were randomly assigned to the MWM or the mobilization with movement added myofascial release (MWM-MFR) group. The MWM group received treatment with only MWM, whereas the MWM-MFR group was treated with MWM and MFR. Pre- and post-intervention passive range of motion (PROM), maximum reaching lengths, and modified star excursion balance test (MSEBT) results were compared for all participants. Wilcoxon signed-rank test and Mann-Whitney U test were used for statistical analysis. Results: The results showed significant within-group differences in ankle PROM, but no significant between-group differences. The maximum reaching length in the MWM-MFR group in the posterolateral direction was significantly different before and after the intervention (p = 0.005). This group also showed significantly reduced ankle abduction in MSEBT during the posteromedial direction section 3 (p = 0.007) and posterolateral direction section 5 (p = 0.049) compared with the MWM group. Conclusion: Combined MWM and MFR intervention improves ankle stability in the coronal plane during the posteromedial and posterolateral forward movement in dynamic balance compared with only MWM in individuals with calf shortening.

Pattern of microimplant displacement during maxillary skeletal expander treatment: A cone-beam computed tomography study

  • Ney Paredes;Ausama Gargoum;Ramon Dominguez-Mompell;Ozge Colak;Joseph Bui;Tam Duong;Maya Giannetti;Fernanda Silva;Kendra Brooks;Won Moon
    • The korean journal of orthodontics
    • /
    • v.53 no.5
    • /
    • pp.289-297
    • /
    • 2023
  • Objective: To analyze the microimplant (MI) displacement pattern on treatment with a maxillary skeletal expander (MSE) using cone-beam computed tomography (CBCT). Methods: Thirty-nine participants (12 males and 27 females; mean age, 18.2 ± 4.2 years) were treated successfully with the MSE II appliance. Their pre- and post-expansion CBCT data were superimposed. The pre- and post-expansion anterior and posterior inter-MI angles, neck and apical inter-MI distance, plate angle, palatal bone thickness at the MI positions, and suture opening at the MI positions were measured and compared. Results: The jackscrew plate was slightly bent in both anterior and posterior areas. There was no significant difference in the extent of suture opening between the anterior and posterior MIs (P > 0.05). The posterior MI to hemiplate line was greater than that anteriorly (P < 0.05). The apical distance between the posterior MIs was greater than that anteriorly (P < 0.05). The palatal thickness at the anterior MIs was significantly greater than that posteriorly (P > 0.01). Conclusions: In the coronal plane, the angulation between the anterior MIs in relation to the jackscrew plate was greater than that between the posterior MIs owing to the differential palatal bone thickness.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF

Clinical Outcomes After Arthroscopic Double-Row Rotator Cuff Repair and Evaluation of Cuff Integrity by CT Arthrography (관절경적 2열 고정 회전근개 복원술 후의 임상 결과 및 CT 관절조영술을 이용한 건의 치유 평가)

  • Jo, Chris H.;Kim, Je-Kyoon;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baek;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.199-206
    • /
    • 2009
  • Purpose: Our goal for this study was to prospectively evaluate the functional & structural outcomes, by means of CT arthroscopy, of arthroscopic double-row fixation for treating rotator cuff tear. We also attempted to determine the variants that affect the functional & structural outcomes. Materials and Methods: Twenty seven consecutive patients underwent arthroscopic rotator cuff repair with double-row fixation. The average age at the time of the operation was fifty six years. The preoperative and postoperative examinations consisted of determining the Constant score, the score for the visual analogue scale for pain, the UCLA score, the American Shoulder and Elbow Surgeons (ASES) score, as well as a full physical examination of the shoulder. Preoperative MR arthrography was used to evaluate the integrity and atrophy of the rotator cuff. We measured the intraoperative tear size in the sagittal and coronal planes. Postoperative CT arthrography was used at one year postoperatively to evaluate the integrity and atrophy of the repaired tendons and muscles. Results: Preoperative MR arthrography revealed an average 29.22 mm tear size in the sagittal plane and an average 22.72 mm tear size in the coronal plane. Twelve cases of supraspinatus muscle atrophy and two cases of infraspinatus atrophy were observed on the preoperative MR arthrography. The average clinical outcome scores all significantly improved at the time of follow-up. At a mean of one year postoperatively, CT arthrography revealed 48.1% of the shoulders had healed, 11.1% showed incomplete healing and 40.7% showed retear of the repaired tendon. Conclusion: Arthroscopic double-row repair can result in improved clinical outcomes and good patient satisfaction. However, the problems about how to enhance healing of the repaired tendon still remain.

Development of Multi-rotational Prosthetic Foot for Lower Limb Amputee (하지 절단자를 위한 다축 회전이 가능한 인공발의 개발)

  • Shin, Hyunjun;Park, Jin-Kuk;Cho, Hyeon-Seok;Ryu, Jei-Cheong;Kim, Shin-Ki
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.305-313
    • /
    • 2016
  • Movements of the lower limb are important for normal walking and smooth oscillation of the center of gravity. The ankle rotations such as dorsi-flexion, plantar-flexion, inversion and eversion allows the foot to accommodate to ground during level ground walking. Current below knee (B/K) prostheses are used for replacing amputated ankle, and make it possible for amputees to walk again. However, most of amputees with B/K prostheses often experience a loss of terrain adaptability as well as stability because of limited ankle rotation. This study is focused on the development of multi-rotational prosthetic foot for lower limb amputee. Our prosthesis is possible for amputees to easily walk in level ground by rotating ankle joint in sagittal plane and adapt to the abnormal terrain with ankle rotation in coronal plane. The resistance of ankle joint in the direction of dorsi/plantar-flexion can be manually regulated by hydraulic damper with controllable nozzle. Furthermore, double layered rubber induce the prosthesis adapt to irregular ground by tilting itself in direction of eversion and inversion. The experimental results highlights the potential that our prosthesis induce a normal gait for below knee amputee.

The Effect of Vision and Proprioception on Lumbar Movement Accuracy (시각과 고유수용성 감각이 요부 운동의 정확도에 미치는 영향)

  • Sim, Hyun-Po;Yoon, Hong-Il;Youn, I-Na
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.31-44
    • /
    • 2007
  • The purposes of this study were to examine the normal lumbar proprioception and identify the effect of vision and proprioception on lumbar movement accuracy through measuring a reposition error in visual and non-visual conditions and to provide the basic data for use of vision when rehabilitation program is applied. The subjects of this study were 39 healthy university students who have average physical activity level. They were measured the ability to reproduce the target position(50% of maximal range of motion) of flexion, extension, dominant and non-dominant side flexion in visual and non-visual conditions. Movement accuracy was assessed by reposition error(differences between intended and actual positions) that is calculated by the average of absolute value of 3 repeated measures at each directions. The data were analysed by paired samples t-test, independent samples t-test, and repeated measures ANOVA. The results were as follows : 1. Movement accuracy of flexion, extension, dominant side flexion, and non-dominant side flexion was increased in visual condition. 2. There were no differences in the lumbar movement accuracy between sexes in visual and non-visual conditions. 3. In non-visual condition, the movement in coronal plane(dominant and non dominant side flexion) is more accurate than that in sagittal plane(flexion and extension). 4. In non-visual condition, there were no differences in the lumbar movement accuracy between dominant and non-dominant side flexion. In conclusion, this study demonstrates that the movement is more accurate when the visual information input is available than proprioception is only available. When proprioception is decreased by injury or disease, it disturbs the control of posture and movement. In this case, human controls the posture and movement by using visual compensation. However it is impossible to prevent an injury or trauma because most of injuries occur in an unexpected situation. For this reason, it is important to improve the proprioception. Therefore, proprioceptive training or exercise which improve the ability to control of posture and movement is performed an appropriate control of permission or interception of the visual information input to prevent an excessive visual compensation.

  • PDF

Magnetic Resonance Imaging Assessment of Acromion Morphology and Superior Displacement of the Humeral Head in the Impingement Syndrome (충돌 증후군에서 견봉 형태 및 상완골 두 상방 전위의 자기공명영상 분석)

  • Koo Bon Seop;Kim Kyung Chul;Oh Jung Hee
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.1
    • /
    • pp.28-34
    • /
    • 1999
  • Purpose: We studied magnetic resonance imaging of acromion morphology and superior displacement of the humeral head in the patients with diagnosis of rotator cuff impingement syndrome, and also documented the relationship of type Ⅲ acromion to the rotator cuff tear. Materials and Methods: We reviewed retrospectively 40 patients(40 shoulders) who had arthroscopic treatment for the diagnosis of stage II impingement or rotator cuff partial tear and did not have other risk lesions except acromion factor. The mean age was 48.7 years at operation. 21 men(2l shoulders), mean age of 26 years, were used as controls. Acromial type, tilt, and superior displacement of humeral head in sagittal plane, and acromial lateral angulation in coronal plane were measured. Four parameters of the patients were compared with those of control group. And then, the data were subdivided and analyzed with respect to acromial type and patient age in the impingement group. Student t test and multi-way ANOVA were used. Results: In impingement group, Farley's type I acromion, 33%, type Ⅱ, 38%, type Ⅲ, 27% and type Ⅳ, 2%. Superior displacement of humeral head( 4.8mm) were characteristic in the impingement group compared with the control group(1.3mm)(p<0.05). But acromial tilt and lateral angulation were not statistically different. In the analysis of the impingement group, the change of 4 parameters was not significant with respect to age(p>0.05), but lateral angulation in type I acromion(18 degree) and superior displacement of humeral head in type Ⅲ acromion(6.3mm) were significantly increased(p<0.05). All 4 parameters were not different between two subdivided types of type Ⅲ acromion. Conclusion: All types of acromian and large lateral angulatian cauld develop impingement syndrame, but acromial tilt was nat risk factar. Appearance of type Ⅲ acromian and increased superiar displacement of humeral head were characteristic findings in the impingement syndrame. Superiar displacement of humeral head as a result of degenerative change of rotatar cuff was probably primary cause far impingement. The type Ⅲ acromian might be an acquired farm, which cauld be expected to accelerate the tear of rotatar cuff as a cansequence.

  • PDF