• Title/Summary/Keyword: Corona-discharge

Search Result 475, Processing Time 0.025 seconds

Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer (변압기 부분방전과 노이즈에 의한 초음파 신호 분석)

  • Gwon, Dong-Jin;Jeong, Gil-Jo;Jin, Sang-Beom;Gwak, Hui-Ro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

A Study on an Ion Wind Created by a Wire Electrode and Parallel Plates Assembly (와이어 전극과 평행판에서 발생되는 이온풍 특성 연구)

  • 안영철;황필재;이재근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.318-323
    • /
    • 2004
  • When a strong electric field is applied between a sharply curved electrode and a blunt surface, the corona may result in a gas movement in the electrode gap which is directed toward the blunt surface. That is called the corona wind. It enhances heat and mass transfer between the surface and the surrounding gas. Moreover such enhancement causes no noise or vibration, which can be applied in complex, isolated geometries, and allows simple control of surface temperatures. This paper examines the relationship between the corona wind and the relative humidity. The facility consists of high voltage power supply thin tungsten wire, plate electrode, multimeter, microammeter and flow meter. Gas velocity is a linear function of voltage, relative humidity and is proportional to the square root of the current. The maximum velocities for the positive and negative corona discharge are 1.9 m/s (2.74 CMM/m), 1.5 m/s(2.15 CMM/m), respectively.

Investigation of Surface Degradation in Silicone Rubber Due to Corona Exposure (코로나 방전에 노출된 고분자 애자용 실리콘 고무의 표면열화)

  • Hong, Joo-Il;Huh, Chang-Su;Lee, Ki-Taek;Hwang, Sun-Mook;Youn, Bok-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1068-1078
    • /
    • 2004
  • In this paper we investigated the characteristics of surface degradation in silicone rubber due to corona exposure and recovery mechanism. It was shown that surface free energy was 22.42 mJ/$m^2$ on initial sample but surface free energy was approximately increased to 71.14 mJ/$m^2$ after 45 minutes. However, surface free energy on silicone rubber after corona discharge treatment was completely recovered within a short time due to diffusion of low molecular weight(LMW) silicone fluid. It was shown that corona discharge insured the increase of diffusible LMW chains, which could lead to recover the surface hydrophobicity. 200~370 g/mol distribution of LMW silicone fluid which was extracted by solvent-extraction with gel permeation chromatography (GPC) was contributed to recovery. The surface degradation characteristics on silicone rubbers and the recovery mechanism based on our results were discussed.

Charge Distribution of Submicron Particles Charged by Spray Electrification or Corona Discharge (분무 및 코로나 방전에 의해 대전된 서브마이크론 입자의 대전량 분포)

  • Lee, Jae-Bok;Bae, Gwi-Nam;Hwang, Jeong-Ho;Lee, Gyu-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.124-132
    • /
    • 2001
  • This paper reports on the charge distribution measurements of submicron particles for three different charging mechanisms, which are spray electrification, bipolar ionization and corona discharge process, respectively. The number of elementary charges per particle was investigated by classifying and counting of a discrete mobility class. Charge distribution measurements were performed with NaCl particles generated from a collision atomizer for 0.01, 0.1, 1% NaCl solutions. Experimental results show than charge level of atomized NaCl particles is high and decreases with increasing the dissolved ion concentration. The charge level of the atomized NaCl particles can be reduced to that o Boltzmann equilibrium conditions by the bipolar ionization(Po(sup)210 bipolar ionizer). The charge level on NaCl particles passing through the corona discharge reactor is much higher than those of atomized or bipolar ionized NaCl particles. The evaluation of these measurements results in charge distribution of the submicron particles.

Effect of Propene($C_3H_6$) ON NO-$NO_2$ Conversion Process in a Pulsed Corona Discharge (펄스코로나 방전에서 프로핀($C_3H_6$)이 NO-$NO_2$ 변환에 미치는 영향에 관한 연구)

  • 박광서;전배혁;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.67-77
    • /
    • 2000
  • Investigated was the effect of propene(C3H6) on the NO-NO2 conversion in dry exhaust gases from lean burn engine using a pulsed corona discharge. A kinetic model was developed to characterize the plasma chemistry in simulated exhausts containing propene. The model uses ELENDIF program to solve Boltzmann equation for electron energy distribution function, and CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement for NO and NO2 concentrations with the experimental data, and predicts the formation of byproducts such as CH2O, CH3HCO, CO AND CH3NO2 Propene enhances the NOx conversion enormously at lower energy density and the NOx conversion increases with the increase of initial propene and oxygen concentration, and temperature.

  • PDF

Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Plasma Reactor with a Ferroelectric Pellet Layer (강유전체층을 갖는 선대선 방편 플라즈마장치의 코로나 방전 및 오존발생 특성)

  • 문재덕;신정민;한상옥
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.7
    • /
    • pp.377-381
    • /
    • 2004
  • A discharge plasma reactor using a ferroelectric pellet packed bed is now used as a removal means of pollutant gases, such as NOx, SOx and VOCs. When an ac voltage is applied to this plasma reactor, then the pellets are polarized, and great electric fields are formed at each top and bottom contact points of the ferroelectric pellets. Thus the points of each pellet become covered with intense corona discharges, where an electrophysicochemical reaction is taking place strongly However these strong discharges also elevate the temperature of the pellets greatly and concurrently decrease the output ozone generation, as a result, the overall removal efficiency of gas becomes decreased greatly A new configuration of discharge plasma reactor using a ferroelectric pellet layer and a wire-to-wire electrode has been proposed and investigated experimentally. It is found that an intensive microdischarge is taking place on the surface of ac corona-charged ferroelectric pellet layer of the proposed reactor, which concurrently enhances the efficiency of plasma generation greatly And, this type of configuration of plasma reactor utilizing a wire-to-wire electrode and a ferroelectric pellet layer could be used as one of effective plasma reactors to remove pollutant gas.

Characteristics of Ultrasonic Signals Caused by Corona Discharge in Air (코로나방전에 의한 공중(空中)초음파 신호 특성)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.38-46
    • /
    • 1999
  • Measurerments of ultrasonic signals caused by corona discharges were perforrred by using an ultrasonic meeasurerment technique to analyze the deve1qxrent states of coronas in a high-voltage power apparatus. We also examined the relationship between discharge magnitude and ultrasonic pulse number to diagnose the deterioration of electrical insulation by corona discharges. From these results, it was found that ultrasonic signals due to corona discharges can be firstly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of ultrasonic signals was closely related to the current pulses by the corona discharges when ac voltages were gradually raised, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, tirre-delaying and directivity charocteristics of ultrasonic signals propagated to air by using ultrasonic oscillation and receiving systems are feJXlrt.ed as a basic data of ultrasonic measurements in out-door HV apparatus.aratus.

  • PDF

The Ultraviolet Generation Characteristics of porcelain and Polymer Insulators by Corona Discharge (코로나 방전에 의한 자기 및 폴리머 애자의 자외선 발생특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.147-152
    • /
    • 2008
  • This paper describes the breakdown poperties of porcelain and polymer insulators using the UV camera. The experiment was carried out using condition of voltage at the KS C IEC 60060-1(2006). As these results, corona discharge in porcelain insulator was generated the weakness point of insulator union. And the corona discharge of polymer insulator happened in union of power source. Also, we could confirm easily weakness part of these insulators by ultraviolet image through the corona discharge. Besides, in the comparison with the exciting technique of ultrasonic detection, it confirmed that deterioration steps are corrected. These steps are possible to judge the deterioration of power facilities through reliable date. Hereafter, this study as the diagnostic technology suitable for the sites is used.

A Study on Conductivity Characteristics of Insulating Oil by Corona Discharge in Oil (유중(油中)코로나 방전(放電)으로 인(因)한 절연유(絶緣油)의 도전특성(導電特性)에 관한 연구(硏究))

  • Kim, Young-Ill
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.71-83
    • /
    • 1979
  • Not only the insulating oil used for extra high voltage and high capacity transformer has a lot of possibilites of a corona discharge in oil, but the oil is easily degraded by a response of light oxidization. This study is either to classfy, with priority given to a transformer oil produced in Korea belonging to, the insulating oil No. 2, the sample irradiated the ultraviolet rays, treated a corona discharge in oil by a high voltage DC source and done nothing, or to measure the characteristics of breakdown, V-i, I-t and electrode material. The obtained results can be summarized as followings: (1) Unless the sample is contacted with the air, on the process to irradiate the ultraviolet rays, the sample less influence on the changes of the electric characteristics. At the same time, if the sample is contacted with the air and irradiated the ultraviolet rays, the sample shows a remarkable changes of the electric characteristics, and a declined breakdown strength. This tells us that the influence of the light irradiation must be considered as a primary factor of degrading the insulating oil. (2) In the oil treated by a corona discharge, breakdown voltage is declined more than in the oil not to be treated with it. This means that the degradation of the insulating oil is getting increased by a corona discharge in oil. (3) It shows that the increase of conducting current has little to do with breakdown voltage. (4) The conducting current depending on the electrode materials can be put in order by value as Al>Cu>Fe. This is due to the differences of the work function of each metals, and an chemical reaction with the insulating oil. These result can be a great help in verifying the degradation progress of the insulating oil and furnish a new technical information to the manufacturers of the insulating oil and electrical equipment designers and operators. Besides, this study would be helpful to improve the electrical characteristics of the insulating oil produced in Korea.

  • PDF

Sterilization of Scoria Powder by Corona Discharge Plasma (코로나 방전 플라즈마를 이용한 화산암재 분말 살균)

  • Jo, Jin Oh;Lee, Ho Won;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.386-391
    • /
    • 2014
  • Atmospheric-pressure nonthermal corona discharge plasma was applied to the sterilization of biologically contaminated scoria powder. Escherichia coli (E. coli) culture solution was uniformly sprayed throughout the scoria powder for artificial inoculation, which was well mixed to ensure uniformity of the batch. The effect of the key parameters such as discharge power, treatment time, type of gas and electrode distance on the sterilization efficiency was examined and discussed. The experimental results revealed that the plasma treatment was very effective for the sterilization of scoria powder; 5-min treatment at 15 W could sterilize more than 99.9% of E. coli inoculated into the scoria powder. Increasing the discharge power, treatment time or applied voltage led to an improvement in the sterilization efficiency. The effect of type of gas on the sterilization efficiency was in order of oxygen, synthetic air (20% oxygen) and nitrogen from high to low. The inactivation of E. coli under the influence of corona discharge plasma can be explained by cell membrane erosion or etching resulting from UV and reactive oxidizing species (oxygen radical, OH radical, ozone, etc.), and the destruction of E. coli cell membrane by the physical action of numerous corona streamers.