• Title/Summary/Keyword: Corona test

Search Result 132, Processing Time 0.029 seconds

Comparative Study of Target Genes and Protocols by Country for Detection of SARS-CoV-2 based on Polymerase Chain Reaction (PCR) (중합효소 연쇄반응 기반의 코로나-19 바이러스 검출법에 대한 국가별 목표 유전자 및 프로토콜 비교 연구)

  • Kim, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.465-474
    • /
    • 2021
  • Corona-19, a disease caused by 'Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)', was declared a global pandemic by the World Health Organization (WHO) in March 2020, and a real-time polymerase chain reaction test is performed as a diagnostic test for screening and confirmation in most countries. However, not only the target genes and protocols differ by countries, but also the procedures for reading the diagnosis results are diverse, so the criteria for confirmed patients differ by country. Therefore, in this review, we discussed the target genes, test techniques, and diagnostic criteria for each country notified by WHO. And the specificity and sensitivity, limits of detection, positive and negative controls, false positive bacteria candidates, and specimens, and the specifics of the control setting were also described. In addition, the characteristics of Korea's test were compared to each country's one. Finally, in order to obtain the same diagnosis result for SARS-CoV-2 in the future, standardized diagnosis methods and result interpretations for Corona-19 diagnosis were proposed.

Development of Algorithm of Surge Test for Quality Control on Electrical Parts of Throttle Body in Automobiles (차량 드로틀 보디 전장부품의 품질관리 성능시험 알고리즘 개발)

  • Son, Jae-Hwan;Kim, Tae-Han
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.1
    • /
    • pp.67-72
    • /
    • 2006
  • This study is on the development of algorithm of surge test for quality control on electrical parts of throttle body in automobiles with internal combustion engine, not only to know its condition to be good or not, but also jugding its condition to be classified into six types. To know whether its condition to be good or not, comparing and analyzing between two waveforms generated from master and test coil of throttle body. If test net area is below 20% of master area, the condition of test coil is good. By analyzing test coil waveform to master coil waveform, the condition of test coil into winding badness, insulation badness, layer and corona discharge, short badness should known. Therefore quality control system on electrical parts of throttle body should be developed.

  • PDF

Design of a Privacy-based Confirmed Case Contact Notification System in the With-Corona Era (With-Corona 시대에 프라이버시 보호 기반의 확진자 접촉 여부 알림 시스템 설계)

  • Mun, Hyung-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.10
    • /
    • pp.138-143
    • /
    • 2021
  • As of this moment, we are tracing people who are closed contact with Covid-19 patients and trying to block the spread of Covid-19 through diagnostic tests. However, the incubation period of the confirmed case is two weeks, and it takes a lot of human resources, time, and money to trace the routes of the confirmed case. In particular, as the number of confirmed cases have been increasing, the cost for finding closed contacts and blocking them in advance exponentially have almost reached the limitation of the budget. In finding closed contacts, all citizens must record an electronic access list every time they visit an amenities such as a store or a restaurant. This is likely the invasion of the privacy of personal location information. In this study, we designed a system that keeps one's location in real time, it will download the movement information of the confirmed case which is collected by KDCA, and it will notify the user when there is an overlap. Moreover, then guide for diagnostic test in advance will be used. The proposed method can solve the difficulty of recording in an electronic access list when visiting a store, and it can block infringement of privacy without providing personal information from KDCA.

A Case Report on Hemiplegia in a Patient with an Intracerebral Hemorrhage of the Basal Ganglia of the Corona Radiata Treated with Traditional Korean and Western Medicine (기저핵-대뇌부챗살 뇌출혈로 인한 반신부전마비에 대한 한·양방 병행 치험 1례)

  • Jung, Da-hae;Kil, Bong-hun;Kim, Dong-won;Youn, Hye-soo;Lee, Eun-chang;Jo, Hye-mi;Han, Da-young;Son, Ah-hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.5
    • /
    • pp.1131-1141
    • /
    • 2021
  • Objective: This study examined the case of a 63-year-old man with a history of hypertension and gout who had developed an intracerebral hemorrhage (ICH) of the right basal ganglia of the corona radiata. Methods: The patient was treated with herbal medicine (Boyanghwanoh-tang and powdered Oryeong-san extract), Western medicine (Anticonvulsants, antihypertensive drugs, psychotropic agents, and others), acupuncture, moxibustion, cupping, and rehabilitative therapy. Their effects were evaluated using the Manual Muscle Test (MMT), Korean version of the modified Barthel Index (K-MBI), National Institute of Health's Stroke Scale (NIHSS), and Modified Rankin Scale (mRS). Results: After treatment, the MMT grade improved from 3/3+ to 4+/4+. Additionally, the K-MBI score improved from 62 to 77. Conclusion: The results suggest that combined traditional Korean and Western medicine can effectively treat patients with ICH.

The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line (초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발)

  • Ju, Mun-No;Yang, Kwang-Ho;Lee, Dong-Il;Shin, Koo-Yong;Lim, Jae-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

Influence of Particle and Filter Charge on Filtration Property of Air Filter under Particle Loading (입자 및 필터 대전상태에 따른 입자부하조건에서 공기정화 필터의 여과특성)

  • Ji, Sung-Mi;Sohn, Jong-Ryeul;Park, Hyun-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.644-655
    • /
    • 2012
  • As soon as a new air filter is applied to an air purification process, the filter gets loaded with dust particles. Thus, the study on the particle loading characteristics of air filter is very essential in order to understand the real filtration phenomena during filter use. In this study, we investigated the effect of particle and filter charge on the particle loading property of air filter. Charged filter and uncharged filter prepared by discharging the charged filter by isopropyl alcohol were used as test samples, and three types of particle having different charge states were supplied to filters tested. For neutralized particles there was a big difference in areal mass loading rates between charged and uncharged filters due to the very small amount of particle charge, on the other hand the difference was diminished for atomized particle and finally almost vanished for corona charged particles. The pressure drop of filter loaded with corona charged particles was only half of those for neutralized and atomized particles at the same areal mass loading because of the porous structure of particle deposit formed on filter fibers, caused by the space charge effect between particles.

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Electrical Properties of Silicone Rubber with Different Particle Size and Amount of ATH (ATH의 입자크기 및 첨가량에 따른 실리콘 고무의 전기적 특성)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Myung, In-Hae;Lee, Tae-Hui;Lee, Tae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.227-230
    • /
    • 2003
  • Silicone rubber has very excellent chemical stability and hydrophobicity. A hydrophobic surface can prevent the formation of continuous water films on the surface in wet and heavily contaminated conditions. This phenomenon contributes to the suppression of leakage current and partial discharges on insulator surfaces. Silicone rubber has been used much for housing materials of polymer insulators. ATH is added to the silicone rubber for improvement of its resistance against surface discharge. In this paper, ATH with different particle size and content was added to the silicone rubber during compounding. Silicone rubber was deteriorated by a corona treatment. Hydrophobicity recovery rate after corona treatment and arc resistance of silicone rubber were investigated. Hydrophobicity recovery rate of silicone rubber was evaluated by the measurement of contact angle. Arc resistance was evaluated by measuring weight loss of silicone rubber after arc resistance test. It was observed that the hydrophobicity recovery rate and arc resistance of silicone rubber were different when different particle size and content of ATH were added.

  • PDF

Comparative Test on Corona Characteristic Between Binding Shapes of the Overhead Cable (바인드 시공형태별 코로나에 의한 전선침식 비교)

  • Kim, Dong-Myung;Lee, Nam-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.197-199
    • /
    • 2008
  • 전연전선을 핀애자에 고정하기 위해 피복바인드선을 사용하고 있는데, 오손지역에서 전선피복과 바인드 사이에서 트래킹으로 인하여 단선고장이 간혹 발생하고 있다. 과거 간접 활선시 사용하던 핫스틱(Hot-stick) 공법에 필요한 바인드 고리의 불필요성이 검토되었고 이러한 고리가 바인드선 내 순환전류를 제공하여 주울열에 의해 전선의 피복에 손상이 발생한다는 의견이 제기되었다. 본 논문에서는 절연전선의 바인드 끝단 형태를 변경하여 전선피복에 대한 침식 영향을 평가하였다.

  • PDF

Ion Effects of HVDC ±500 kV Double Bipole Overhead Transmission Line with Metallic Return Conductor Using Full-scale Test Line (실증시험선로를 이용한 도체귀로형 HVDC ±500 kV Double Bipole 가공송전선로의 이온류 특성 평가)

  • Shin, Kooyong;Kwon, Gumin;Ju, Munno;Woo, Jeong Min
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.249-256
    • /
    • 2019
  • A full-scale test line was established to verify the electrical environmental interferences caused by the HVDC ±500 kV Double Bipole overhead transmission line with metallic return conductor, which is scheduled for construction in Korea and the fullscale test was conducted for one year. And through the human perception test of the DC electric-field under the HVDC Double Bipole line, the threshold value at which the human detects DC electric field was investigated to verify the validity of the design guide for the HVDC ±500 kV Double Bipole overhead transmission line. The polarity configuration of the HVDC ±500 kV Double Bipole test line was arranged diagonally with the same polarity in terms of the electrical environment disturbance and operation. The test line utilized the 6-bundle arrangement to prevent the corona discharge taking into account the domestic social acceptability. The test results show that the HVDC ±500 kV Double Bipole transmission line generated very little corona discharge from the conductors. Therefore, both DC electric field and ion current density met the domestic design guide for DC overhead transmission lines. Also, the human perception test of DC electric fields under the test line showed that 70% of participants did not recognize the DC electric field even when exposed to 23 kV/m.