• Title/Summary/Keyword: Corona

Search Result 1,313, Processing Time 0.034 seconds

Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment (코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공)

  • Hong, Young-Ki
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

Characteristics of Ion Wind Generation According to Application of Acceleration Electrodes (가속전극의 적용에 따른 이온풍 발생 특성)

  • Kim, Chol-Gyu;Jang, Kyeong-Min;Kim, Jin-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.5
    • /
    • pp.656-661
    • /
    • 2019
  • Currently, the devices to generate ion winds in air are mainly composed of corona electrodes and induction(ground) electrodes, of which the corona electrodes mainly use needles or wires as electrodes and the induction electrodes use plate electrodes of ring or mesh type. Ion winds can be effectively generated through a diverse combination of corona electrodes and induction electrodes mentioned above. However, only changing the form and structure of corona electrodes and induction electrodes has a limit in raising the speed of ion winds. This paper conducted a study on the characteristics of ion wind generation by additionally installing acceleration electrodes in addition to corona electrodes and induction electrodes to increase the speed of ion winds.

Application of Nano Coating to ACSR conductor for the Protection of Transmission lines against Solar Storms, Surface Flashovers, Corona and Over voltages

  • Selvaraj, D. Edison;Mohanadasse, K.;Sugumaran, C. Pugazhendhi;Vijayaraj, R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2070-2076
    • /
    • 2015
  • Nano composite materials were multi-constituent combinations of nano dimensional phases with distinct differences in structure, chemistry and properties. Nano particles were less likely to create large stress concentrations and thereby can avoid the compromise of the material ductility while improve other mechanical properties. Corona discharge was an electrical discharge. The ionization of a fluid surrounding a conductor was electrically energized. This discharge would occur when the strength of the electric field around the conductor was high enough to form a conductive region, but not high enough to cause electrical breakdown or arcing to nearby objects. This paper shows all the studies done on the preparation of nano fillers. Special attention has given to the ACSR transmission line conductor, TiO2 nano fillers and also to the evaluation of corona resistance on dielectric materials discussed in detail. The measurement of the dielectric properties of the nano fillers and the parameters influencing them were also discussed in the paper. Corona discharge test reveals that in 0%N ACSR sample corona loss was directly proportional to the applied line voltage. No significant change in corona loss between 0%N and 1%N. When TiO2 nano filler concentration was increased up to 10%N fine decrement in corona loss was found when compared to base ACSR conductor, corona loss was decreased by 40.67% in 10%N ACSR sample. It was also found from the surface conditions test that inorganic TiO2 nano filler increases the key parameters like tensile strength and erosion depth.

A Study on the Perception of Corona19 Period Play Culture Based on Big Data Analysis

  • Jung, Seon-Jin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.196-203
    • /
    • 2020
  • In this study, we tried to explore the actual direction for the play culture by looking at the social perception of the change of play culture due to the Corona 19 using big data analysis. For this research, we used Textom, a website specializing in collecting big data, and collected 10,216 data using keywords of "Corona + Play," "Play Culture" and "Leisure" from January 19, 2020 to September 30, 2020, when the first confirmed case of Corona 19 occurred in Korea on various portal sites at home and abroad. The results of this paper showed that the social perception of the play culture in Corona 19 was 51.61%, not much different from the negative image of 48.15%. It is necessary to develop a play culture program that can identify people's various desires and emotions under the premise that situations similar to the current With Corona period and Corona19 can occur at any time, and find mental and physical stability and vitality in unstable situations. In addition, the results of this study can be used as basic data for the development of play culture policies or programs, with the significance that this study helped vitalize big data utilization research in the fields of play, leisure, and culture.

Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries (핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구)

  • Cheong Seongir;Lee Jaekeun;Chung Dongkyu;Ahn Youngchull
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-U;Lee, Dong-In;Lee, Gwang-Sik;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF

Surface treatment of polyethylene terephthalate films by corona discharge (코로나방전에 의한 polyethylene terephthalate 필름의 표면처리)

  • 김명룡
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.316-323
    • /
    • 1995
  • A vital step in magnetic tape manufacturing is the surface modification of polymer substrate prior to ink application. A critical element for good adhesion of magnetic ink on polymeric substrate is the ability to join ink in cost-effective manner. Corona discharging is one of the effective methods of modifying polymer surface to improve adhesion while maintaining the desirable properties of the film itself. Surface treatment by corona which is exposure of film surface to electron or ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and/or introducing reactive chemical groups. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission be avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polymer substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle measurements.

  • PDF

A Study on the Surface Corona Discharge in the Gas with different Mixing Ratio of Air to $SF_6$ ($SF_6$와 공기의 혼합기체중에서의 연면 코로나 방전)

  • 전춘생;조기선;우호환
    • 전기의세계
    • /
    • v.26 no.6
    • /
    • pp.78-85
    • /
    • 1977
  • This paper studies flashover voltage and surface corona loss of A.C and D.C in the mixed gas of air and SF$_{6}$ for solid insulators P.V.C, arcylic, glass and bakelite in two cases. In one case, those solids are covered with transformer oil and the other case, those solids are not covered with it. 1) The flashover voltage for each solids in SF$_{6}$ is more than three times compared with that in the air. The flashover voltage for P.V.C is the highest and then arcylic, glass, bakelite in a decreasing order. 2) The more the amount of SF$_{6}$ in the mixing ratio, the less corona loss. The P.V.C shows the least amount of corona loss and the bakelite the largest. 3) Compared with the corona loss of positive polarity and the negative polarity, the former has less corona loss than the latter. 4) The more the number of flashover discharge, the less insulation of each solids, but in case of bakelite, insulation almost vanishes after a couple of discharge. 5) When each insulator is covered with transformer oil, the flashover voltage generally increases and the corona loss decreases.eases.

  • PDF

The Physicochemical Characteristics of PET Fabrics Treated with Low Temperature Glow Plasma and Atmospheric Corona Discharge (진공 저온 플라즈마와 대기압 코로나 방전가공 PET 직물의 물리화학적 특성)

  • Ma, Jaehyuk;Yang, Jinyoung;Koo, Kang;Yang, Hyun A;Park, Youngmi
    • Textile Coloration and Finishing
    • /
    • v.26 no.3
    • /
    • pp.201-208
    • /
    • 2014
  • The high value-added functionality for synthetic fiber can be considered through a plasma enhanced treatment. In this study, PET(Polyethyleneterephthalate) was treated with a glow plasma and corona treatment. Surface characteristics of treated fabric were investigated using electron scanning microscopy(SEM), contact angle, X-ray photoelectron spectroscopy(XPS), tensile and adhesion strength. It was found that the contact angle showed $85.5^{\circ}$ for untreated fabric, $0^{\circ}$ for plasma and corona treatment at the condition of 200W for 7min. By XPS analysis, atomic ratio of O 1s/C 1s was increased from 0.27 to 0.43 by glow plasma and 0.27 to 0.41 by corona treatment at 200W for 7min, respectively. Glow plasma and corona treatment did not significantly change the tensile strength of PET fabric. Adhesion strength showed a substantial enhancement for the surface treated with the glow plasma, while corona treatment was adversely affected.

Development of Corona Cage Measurement System for Simulation on Electrical Environmental Characteristics of HVDC Overhead Transmission Line (HVDC 가공 송전선로 전기환경특성 모의시험용 코로나 케이지 계측시스템 개발)

  • Kil, Gyung-Suk;Yang, Kwang-Ho;Lee, Sung-Doo;Ju, Mun-No
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.245-249
    • /
    • 2006
  • Corona characteristics of conductors are dependent on the electric field conditions in the immediate vicinity of the conductors. In case of DC transmission line, particularly, the space charge plays an important role in the electric field distribution. Therefore, DC corona cage simulation is necessary for long-term test in the same conditions. This paper presents the results of designing and constructing hardwares such as DC power supply, measurement system and DAS to carry out the simulation. The corona cage longitudinally is divided into five equal length sections and three inner sections of those are isolated from the ground of outer cage. The measurement items are radio noise, corona current, television noise, audible noise and meteorological conditions. In the next step, various simulations about the type and configuration of two or three candidate conductors will be conducted. And then finally an environmentally-friendly conductor for HVDC overhead transmission line will be decided.