• Title/Summary/Keyword: Corneal curvature

Search Result 24, Processing Time 0.017 seconds

Fitting of Soft Contact Lenses (소프트 콘택트 렌즈의 피팅)

  • Lee, Eun-Hee;Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.173-180
    • /
    • 2000
  • To determine the effect of base curve and diameter of soft contact lenses on the fitting under the various corneal curvature, the model eyes which was made of either stainless steel or ordinary wood, were used as the substitutes for human eyes. The evaluations of fit of the soft contact lenses on both wood model eyes and human eyes were found to be very similar to each other. All the contact lenses except very thin ones became flat after fit on the stainless steel model eyes because the model eye could not preserve enough moisture to hold the edge of contact lenses on the steel ball's surface. The relationships between the base curves of contact lenses and radii of cornea for the optimum (normal) fit were measured as follows : corneal curvature (C.C)<7.6 mm : base curve(B.C) 8.4 mm, C.C 7.6~7.8 mm : B.C 8.4~8.5 mm. C.C 7.8~8.1 mm : B.C 8.6 mm. It is concluded that larger base curve is required for the eyes which have abnormal bulge on its cornea. It is found that very thin soft contact lenses can be easily twisted or folded regardless of moisture content when they were fit on the relatively dry eyes(corneas).

  • PDF

A Measurement Algorithm using Gray-level Thresholding in Automatic Refracto-Keratometer (그레이-레벨 한계 기법을 이용한 자동 시각 굴절력 곡률계의 측정 알고리즘)

  • Sung, Won;Park, Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.9B no.6
    • /
    • pp.727-734
    • /
    • 2002
  • Currently. people become interested in the development of measuring instrument related to eyesight. In this study, we developed software of electronic part in automatic refracto-keratometer. If an automatic system, which uses images from an optical instrument, can inform the in-spector of an accurate eyesight measured value after the internal process, the frequency of mistakenly observed value will be reduced considerably. This software is using morphological filtering and gray-level signal enhancing techniques. The morphological filtering is the first process, from images of the optical instrument, to transform an original image which is hard to process into manageable one. The second process is a signal enhancing technique to the first processed image using gray -level thresholding technique and is used to reduce an error caused by the variety in distribution of the gray value of image. Therefore, this software system in electronic part will make more effective eyesight measurement by reducing the error effectively when applied to the optical image which is difficult to get accurate measurement value.

Effects of Base Curve on Fitting with the current Soft Contact Lenses (베이스 커브에 의한 콘택트렌즈 피팅 효과)

  • Choe, Oh Mok;Gang, Myoung Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • The study investigated the effects of base curve radius art the fit of thin, mid-water contact lenses. It was found that central corneal curvature(as measured with the keratometer) was not predictive of the best fitting base curve. Proper lens fit may be the single most important factor that ultimately determines the success of contact lens wear. Comfort, vision, and physiological response are all dependent on the fit of the lens. The percent of optimal fits was highest with the 8.4 mm base curve lens for all three ranges of keratometry values. When fit with the 8.4 mm lens. For most eyes, fitting a flatter lens led to greater decentration, decreased comfort, and no increase in lens movement. The 8.4 mm lens was found to provide on "optimal" fit in over 60% of eyes tested and a fit of "good" or "better" in nearly 90% of eyes tested. Comparisons of different manufactures' lens found that similiar lenses do not always fit in the same way due to subtle design and production differences. Therefore, different products may require different base curve radii to fit the same patient. This is even true when water content, center thickness, and diameter are approximately the same. A praditioner fitting a new patient in this lenses should begin with the 8.4 mm base curve radius.

  • PDF

A Mechanical Model of Excimer Laser Surgery (엑시머 레이저 수술의 역학적 모델)

  • Shin, Jung-Woog;Kim, Jong-Hyun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.57-60
    • /
    • 1993
  • A finite element-based computer simulation of excimer laser susery was conducted to study some factors on the surgery. In particular, the radius of curvature at the apex of the cornea was examined under various surgical conditions. Corneal tissue was assumed to be a nearly incompressible, linear elastic, homogeneous, isotropic material under very small deformation. The geometry of the human cornea was taken from the experimental data[1]. The simulation utilized ANSYS(Swanson Analysis System Inc.Rev.4.4A). In this study, the major factors which affect the outcomes of the excimer laser surgery were investigated. First, two patterns of surgery with various surgery thickness(40-70micrometers) were examind. The pattern#1 describes the meridian from the apex to the edge of the surgery area to be straight. And the corresponding meridian of the pattern 2 can be expressed as a quardratic function. The results show that the pattern #2 is more realistic and effective. Then, the effects of other factors were investigated based on the pattern #2. Other factors are:various diameters of the surgical area (3-8 milimeters), Young's modules(3.5-4.5MPa), and depth of surgery at the apex(40-70micrometers). Compared with the computer simulation of the radial keratotomy surgery[2], the excimer laser surgery was proven to be more effective in treating myopia patients. In conculusion, the results of the simulation are qualitative agreement with clinical experience[3] indicating the potential of the finite element model of the surgery as a guideline to the surgeon before actual surgery.

  • PDF