• Title/Summary/Keyword: Cornea

Search Result 278, Processing Time 0.024 seconds

Backbone NMR assignments of the FAS1-3/FAS1-4 domains of transforming growth factor-beta-induced protein

  • Kang, Dong-Hoon;Yi, Jong-Jae;Sim, Dae-Won;Park, Jung-Wook;Lee, Sung-Hee;Kim, Eun-Hee;Jeon, Young-Ho;Son, Woo Sung;Won, Hyung-Sik;Kim, Ji-Hun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • An extracellular matrix protein, transforming growth factor-beta-induced protein (TGFBIp/βig-h3), which is induced by transforming growth factor-β in the human cornea, skin, and matrix of many connective tissues, is associated with the adhesion, migration, proliferation, and differentiation of various cells. TGFBIp contains four homologous repeat domains, known as FAS1 domains, where certain mutations have been considered to cause corneal dystrophies. In this study, backbone NMR assignments of FAS1-3/FAS1-4 tandem domain were obtained and compared with those previously known for the isolated FAS1-4 domain. The results corroborate in solution the inter-domain interaction between FAS1-3 and FAS1-4 in TGFBIp.

Distribution and Characteristics of Pacific Herring Clupea pallasii Spawning Beds in Jinhae Bay, Korea (진해만에서의 청어(Clupea pallasii) 산란장 분포와 특성)

  • Moon, Seong Yong;Choi, Jung-Hwa;Lee, Hae-Won;Kim, Jung-Nyun;Heo, Jin Seok;Gwak, Woo Seock;Lee, Yong-Deuk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.5
    • /
    • pp.534-538
    • /
    • 2019
  • The distribution and characteristics of spawning beds of the Pacific herring Clupea pallasii, were observed by scuba diving in Jinhae Bay, Korea, with a focus on marine vegetation as adhesive substrates and egg density during the spawning season. In 2017, the fertilized eggs of C. pallasii were mainly found attached to the leaves of algae species Carpopeltis cornea, Gracilaria textorii, and Acrosrium polyneurum at the rocky shore in Wonpo-dong and Jeodo. The mean density of fertilized eggs in C. pallasii spawning beds was $153,776eggs/m^2$ off Wonpo-dong and $856,430eggs/m^2$ off Jeodo, giving an estimated total of $5.345{\times}10^9$ eggs in Wonpo-dong and $3.3074{\times}10^{10}$ eggs in Jeodo. We examined spawning beds with an area of $38,619m^2$ off Wonpo-dong and $34,760m^2$ off Jeodo. The choice of spawning bed may be affected by the composition of marine vegetation, such as the algal diversity of rocky shore environments, which could affect adhesive substrates and egg density during the spawning season. The results of the present study suggest that the spawning season of C. pallasii in Jinhae Bay is in January to mid-February.

Triggered Electrooculography for Identification of Oculomotor and Abducens Nerves during Skull Base Surgery

  • Jeong, Ha-Neul;Ahn, Sang-Il;Na, Minkyun;Yoo, Jihwan;Kim, Woohyun;Jung, In-Ho;Kang, Soobin;Kim, Seung Min;Shin, Ha Young;Chang, Jong Hee;Kim, Eui Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.282-288
    • /
    • 2021
  • Objective : Electrooculography (EOG) records eyeball movements as changes in the potential difference between the negatively charged retina and the positively charged cornea. We aimed to investigate whether reliable EOG waveforms can be evoked by electrical stimulation of the oculomotor and abducens nerves during skull base surgery. Methods : We retrospectively reviewed the records of 18 patients who had undergone a skull base tumor surgery using EOG (11 craniotomies and seven endonasal endoscopic surgeries). Stimulation was performed at 5 Hz with a stimulus duration of 200 μs and an intensity of 0.1-5 mA using a concentric bipolar probe. Recording electrodes were placed on the upper (active) and lower (reference) eyelids, and on the outer corners of both eyes; the active electrode was placed on the contralateral side. Results : Reproducibly triggered EOG waveforms were observed in all cases. Electrical stimulation of cranial nerves (CNs) III and VI elicited positive waveforms and negative waveforms, respectively, in the horizontal recording. The median latencies were 3.1 and 0.5 ms for craniotomies and endonasal endoscopic surgeries, respectively (p=0.007). Additionally, the median amplitudes were 33.7 and 46.4 μV for craniotomies and endonasal endoscopic surgeries, respectively (p=0.40). Conclusion : This study showed reliably triggered EOG waveforms with stimulation of CNs III and VI during skull base surgery. The latency was different according to the point of stimulation and thus predictable. As EOG is noninvasive and relatively easy to perform, it can be used to identify the ocular motor nerves during surgeries as an alternative of electromyography.

Anti-inflammatory and Anti-itching Effects of Herbal Medicine Complex Extracts(NI-01) (한약복합추출물(NI-01)의 항염증 및 소양감 억제 효과)

  • Kim, Hyun-A;Kim, Suk-Kyung;Kim, Bae-Hwan
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.34 no.6
    • /
    • pp.341-347
    • /
    • 2020
  • The purpose of this study was to investigate the possibility of herbal medicine complex extract (NI-01), which were prepared from 6 natural materials (Cinnamomum cassia Blume, Lonicerae Flos, Paeonia suffruticosa Andrews, Arctium lappa Linne, Schzandra chinesis Bailon, Elsholtzia ciliata Hylander), as a functional material for inhibition of atopic dermatitis. anti-oxidative activity was confirmed by measuring DPPH electron donating ability and ABTS+ radical scavenging ability. Cytotoxicity and NO inhibition were measured using RAW 264.7 cells to confirm anti-inflammatory efficacy. The test substance was orally administered to the pruritus-induced ICR mice to confirm the inhibition of pruritus. The bovine cornea opacity and permeability (BCOP) assay was performed to confirm safety for irritation. NI-01 showed high antioxidant activity in DPPH and ABTS+ methods. In the anti-inflammatory effect tests with RAW 264.7 cells, NO production was inhibited at NI-01 concentrations of 50 (14.9%) and 100 (4.2%) ㎍/mL, which indicated that the anti-inflammatory effect was increased in a concentration-dependent manner. NI-01 also showed anti-itching effect after inducing of itching by compound 48/80 in ICR mice. NI-01 was proved to be a non-irritant substance in BCOP assay. The results of this study suggested that the herbal medicine combined extract (NI-01) has high antioxidant, anti-inflammatory and anti-itching effects, and safety for irritation. Therefore, herbal medicine complex extract (NI-01) is thought to be highly applicable for the inhibitory ingredients of the atopic dermatitis.

Interspecies comparative morphological evaluation of the corneal epithelial stem cell niche: a pilot observational study

  • Popova, Petya;Malalana, Fernando;Biddolph, Simon;Ramos, Tiago;Parekh, Mohit;Chantrey, Julian;Ahmad, Sajjad
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.62.1-62.10
    • /
    • 2022
  • Background: The corneal and limbal morphology relevant to corneal epithelial maintenance in ten different species was examined using histological methods. Objectives: The presence of a Bowman's layer, limbal epithelial cell, and superficial stromal morphology was examined in the following species to evaluate the differences in corneal thickness and epithelium: Java sparrows, frogs, macaws, spoonbills, red pandas, penguins, horses, Dobermans, orangutans, and humans. Methods: Corneal sections (4 ㎛) were obtained from ten ocular globes from three different animal classes: Aves, Amphibia, and Mammalia. All sections were stained with hematoxylin and eosin and periodic acid-Schiff reaction. After microscopy, all stained slides were photographed and analyzed. Results: Significant morphological differences in the corneal and limbal epithelia and their underlying stroma between species were observed. The number of corneal epithelial cell layers and the overall corneal epithelial thickness varied significantly among the species. The presence of a Bowman's layer was only observed in primates (orangutans and humans). Presumed supranuclear melanin caps were noted in four species (orangutans, macaws, red pandas, and horses) in the limbal basal epithelial layer (putative site of corneal epithelial stem cells). The melanin granules covered the apex of the cell nucleus. Conclusions: Supranuclear melanin capping has been described as a process within the epidermis to reduce the concentration of ultraviolet-induced DNA photoproducts. Similarly, there may be a relationship between limbal stem cell melanin capping as a protective mechanism against ultra-violet radiation.

A Comparison of the Movement of Aspheric RGP Lens on Cornea by the Amounts of Keratometric Astigmatisms using Keratometer and Corneal Topography (각막곡률계와 각막지형도를 이용한 각막난시 측정값에 따른 비구면 RGP 렌즈의 각막에서 동적움직임 비교)

  • Park, Sang-Il;Lee, Se Eun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.123-133
    • /
    • 2011
  • Purpose: The present study was conducted to analyze any difference in the movement of aspheric RGP lens by the amounts of keratometiric astigmatisms using keratometer and corneal topography. Methods: Corneal curvatures in thirty six eyes of males and females of with-the-rule keratometric astigmatisms in their twenties were measured by a keratometer and worn aspheric RGP lenses. Then, lens rotations, vertical and horizontal movements of lens by blinking were measured to compare with lens movements when aspheric RGP lenses were fitted by total keratometric astigmatisms using corneal topography. Results: The case having higher amount of central keratometric astigmatism was 61.1% of subjects, however, 36.1% of subjects showed higher total keratometric astigmatism indicating that central keratometric astigmatism was not always bigger than total keratometric astigmatism. Since over 0.25 diopter difference between total and central keratometric astigmatisms was shown in 19 eyes (52.8% of subjects), the prescription for lens fitting could be changed. Significant difference in horizontal movement was detected with increase of astigmatism when it compared based on the amount of keratometric astigmatism measured by a keratometer. However, there was no significant difference in lens rotation, horizontal and vertical movements by comparison with the amount of total keratometric astigmatism using a corneal topography. When central keratometric astigmatism measured by keratometer was bigger than total keratometric astigmatism estimated by corneal topography, bigger lens rotation was shown compared with opposite case. Also, the tendency of bigger lens rotation was measured with the increase of keratomatric astigmatism in the case of same prescription having same base curves with same amount of keratometric astigmatism but different curvatures. Conclusions: From the present study, we concluded that lens movements on cornea were not totally different when aspheric RGP lens fitted on with-the-rule astigmatism by keratometer and corneal topography. However, there was some difference in certain lens movements. Therefore, we concluded that further study on the relationship between the prescriptions for lens fitting should be conducted for improving the rate of successful lens fitting by keratometer or for the proper application of corneal topography for lens fitting.

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

Comparison of Tear Distributions by the Corneal Eccentricity when Fitted with Spherical and Aspherical RGP Lenses (구면 및 비구면 RGP렌즈 피팅 시 각막 이심률별 눈물분포 비교)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.99-108
    • /
    • 2016
  • Purpose: The present study was aimed to compare the tear volume and distribution by corneal eccentricity when fitted with spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted in best alignment on a total of 77 subjects (136 eyes) in their twenties and thirties without any ocular disease or ocular surgery experience. The tear volume was analyzed by estimating the concentration of tear stained with fluorescein in the center of RGP lens as well as at the mid-peripheral and peripheral areas, and the difference of tear distributions was analyzed according to corneal eccentricity. Results: Tear distribution from the center to the peripheral area was not significantly different when spherical RGP lenses were fitted on the corneal eccentricities of e < 0.38 and $0.68{\leq}e$, indicating the relatively even tear distribution compared with other corneal eccentricity. In the case of aspherical RGP lenses, the difference of tear distribution between the central and peripheral areas was smaller than spherical RGP lenses. The significant difference of tear distribution according to RGP lens design was observed in the corneal eccentricity of 0.48 < e < 0.68. In other words, more even tear distribution was shown when aspherical RGP lenses were fitted on the cornea with eccentricity of $0.48{\leq}e<0.68$ and spherical RGP lenses were fitted on the cornea with eccentricity $0.68{\leq}e$. Furthermore, tear volume in the mid-peripheral area increased with higher corneal eccentricity. Conclusions: The results suggest that the appropriate selection of RGP lens design according to corneal eccentricity is necessary since tear volume and distribution by the regions of spherical and aspherical lenses are affected by corneal eccentricity.

The Inhibitory UV-B Blocking Rate of Eyeglasses Lens on the Enzymes Denaturation in Cornea (각막 내 효소의 변성을 억제하는 안경 렌즈의 UV-B 차단율)

  • Kim, So Ra;Lee, Jee Hee;Choi, Jung-Im;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.253-260
    • /
    • 2013
  • Purpose: To investigate the UV-B blocking rate of eyeglasses lens which can prevent enzymes denaturation in cornea. Methods: The denaturation degree of RNase A and catalase, superoxide dismutase (SOD) was determined by using Acrylamide gel electrophoresis after UV-B irradiation of 312 nm for 1, 3, 6, 24 and 96 hours. Also, the inhibitory effect of eyeglasses lens having UV-B blocking rate of 50%, 80%, 95% and 99% on the enzymes denatration was measured. Results: The denaturation of RNase A was induced by 1 hour-irradiation of UV-B. To inhibit RNase A denaturation after UV-B irradiation between 1 hour and 6 hours, UV-B blocking lens of 95% were effective. UV-B blocking lens of 99% suppressed the inhibition of RNase A denaturation after the UV-B exposure between 24 hours and 96 hours. The denaturation of catalase was not induced by 1 hourirradiation of UV-B. To inhibit enzyme denaturation after UV-B irradiation between 1 hour and 6 hours, UV-B blocking lens of 50% were effective. UV-B blocking lens of 95% suppressed the inhibition of enzyme denaturation induced by UV-B irradiation between 24 hours and 96 hours. The SOD denaturation was not induced by UV-B irradiation shorter than 6 hours exposure. The UV-B blocking lens of 50% could inhibit SOD denaturation after the UV-B irradiation for 24 hours. When SOD was exposed to UV-B for 96 hrs, SOD denaturation was inhibited by eyeglasses lens with UV blocking rate higher than 95%. Conclusions: The results demonstrated that the proper UV-B blocking rates of eyeglasses lens to inhibit the enzymes denaturatioin was different according to the types of enzymes and its inhibitory effect was effective only when eyeglasses lens had higher than certain UV-B blocking rate.

The Analysis of Corneal Patterns in Korean 20s by Corneal Topography and Corneal Radii by Astigmatic Degree (각막지형도를 이용한 20대의 각막형상 및 난시도에 따른 각막곡률반경의 분석)

  • Kim, So Ra;Gil, Ji-Yeon;Park, Chang Won;Kim, Ji Hye;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.273-281
    • /
    • 2011
  • Purpose: In order to provide the fundamental information for the design development of RGP lenses and its clinical prescription, the corneal types of Korean twenties were analyzed according to corneal shapes, astigmatic degree, and the certain distance from the corneal apex. Methods: Corneal types of total 252 eyes in 20s were firstly classified, then their corneal radii from the certain distance from the corneal apex were measured by corneal topography and further analyzed based on the astigmatic degree. Results: Korean 20s' corneal types were classified as 14.3%(36 eyes) of round, 31.3%(79 eyes) of oval, 28.6%(72 eyes) of symmetric bow tie, 17.5%(44 eyes) of asymmetric bow tie, 8.3%(21 eyes) of irregular shapes. The round and oval typed corneas had mild astigmatic degree whereas the higher astigmatic degree in symmetric and asymmetric bow tie typed corneas were shown. The relative corneal radii of round and oval typed corneas at each distance from corneal apex were shown to consistently increase regardless of astigmatic degrees when they measured at certain distances from the corneal apex. However, the relative corneal radii of symmetric and asymmetric bow tie typed corneas within 1.0-1.5mm from the corneal apex were decreased, which showed steeper slope than it within 1.0 mm and somewhat different based on astigmatic degrees. Bigger change of corneal radii outer 3.5 mm from the corneal apex in symmetric bow tie typed corneas with astigmatism of 1.50-2.00 D and 2.25-2.75 D appeared. Conclusions: The consideration of radial change from the central cornea to peripheral cornea is necessary for manufacturing RGP lens and its prescription since they showed different change in corneal radii by corneal patterns and astigmatic degrees.