• Title/Summary/Keyword: Core Radius

Search Result 145, Processing Time 0.026 seconds

Construction Case of Maintenance-free Track System in Application of Elastic Rail Fastening System for Sharp Curved Section (급곡선용 레일탄성체결장치를 사용한 생력화궤도 시공 사례)

  • Kong Sun-Yong;Kim Sang-Jin
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.382-388
    • /
    • 2005
  • SMSC(Seoul Metropolitan Subway Corporation) is substantially taking the core role of mass transit system in Seoul Metropolitan area. When it was built, the design had challenged to sharp curved tracks less than 250m radius considering the protection of buildings and cultural properties as well as the connection to ground roads. Such circumstances have required a certain extent of slack in track geometry and therefore led to the construction of ballasted track with wooden sleepers. However, the dynamic force from running on sharp curved track has caused the misalignment and abnormal failure of track geometry, and it has resulted in a frequent maintenance and repair works which require a lot of cost and manpower. In this paper, we present the construction case of maintenance-free track system by using of concrete sleeper and elastic rail fastening system to ensure the safety of both passengers and trains, and to contribute the effective maintenance for track facilities of SMSC.

  • PDF

Fluorescence and Laser Light Scattering Studies of Modified Poly(ethylene-co-methylacrylate0 Ionomers on the Formation of Stable Colloidal Nanoparticles in Aqueous Solution

  • 여상인;우규환
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.10
    • /
    • pp.1054-1059
    • /
    • 1998
  • Fluorescence and dynamic light scattering measurements were applied to the study of formation and structure of aggregated colloidal particles in modified poly(ethylene-co-methylacrylate) ionomers in aqueous solution. Both 8-anillino-l-naphthalene-sulfonic acid (ANS) and pyrene were used as fluorescence probe to obtain the information on the structure of particle surface and inside, respectively. Three different ionomers used in this study started to aggregate at very dilute concentration, 3-8 x 10-6 g/mL. In this study, we demonstrate that the polyethylene ionomers can form stable nanoparticles. The hydrophobic core made of the polyethylene backbone chains is stabilized by the ionic groups on the particle surface. Such a formed stable nanoparticles have a relatively narrow size distribution with an average radius in the range of 27-48 nm, depending on the kind of ionic groups. Once the stable particles are formed, the particle size distributions were nearly constant. This study shows another way to prepare surfactant-free polyethylene nanoparticles.

Development of the All Wheel Steering ECU for Articulated Vehicle (굴절차량을 위한 전차륜 조향 시스템 전자제어 장치 개발)

  • Kim, Ki-Jeong;Chung, Ki-Hyun;Choi, Kyung-Hee;Lee, Soo-Ho;Park, Tae-Won;Moon, Kyeong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1231-1236
    • /
    • 2008
  • Since the bi-modal tram is too long so that the traditional steering system controlled only the first axle increases its turning radius, it is not suitable to the domestic road environment. In addition, it become hard to make fine parking with the traditional steering system. To resolve the problem, the bi-modal tram requires an all wheel steering system (AWS) that the second axle is controlled by the first axle's degree and the velocity of vehicle, and the third axle is steered by the articulation angle's degree and the velocity of degree. This paper addresses the factors for the AWS ECU design, the strategies to solve the problems, the core technologies for the implementation, and also the outcomes and analysis of the performance evaluation of implemented system.

  • PDF

Optical-Loss Measurement of a Silicon-Slab Waveguide

  • Tresna, Wildan Panji;Putra, Alexander William Setiawan;Maruyama, Takeo
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.551-557
    • /
    • 2020
  • A mirror-in-slab waveguide is fabricated on a slab waveguide by using the refractive-index contrast between two materials, with the reflection performance depending on the slab waveguide's design. In this research, a slab waveguide design consisting of silicon (Si) as the core and SiO2 as the substrate was designed and developed to determine the coupling, waveguide, and mirror losses. Based on experimental results, coupling loss is dominant and is affected by the design of the slab waveguide. Furthermore, the mirror loss is affected by the design of the mirror, such as the curvature radius and the size of the mirror. TE and TM polarizations of light are used in the measurements. The experimental results show that mirror losses due to reflection by mirrors are 0.011 dB/mirror and 0.007 dB/mirror for TE and TM polarizations respectively. A simulation was performed to confirm whether the size of mirror is sufficient to reflect the input light, and to check the quality of the surfaces of fabricated mirrors.

Planning for Amphibians Habitats in Urban Forest Wetlands, Korea (도시 산림습지 내 양서류 서식처 조성방안 연구)

  • Hur, Myung-Jin;Han, Bong-Ho;Kwak, Jeong-In
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.6
    • /
    • pp.1-19
    • /
    • 2017
  • This study set out to identify problems with amphibian habitation by the wetland types and improve their habitation environment in urban forest wetlands, thus creating a habitat for amphibians. Study site include forest swamps in Jatjul Park as well as Yeoji neighborhood Park in Guro-gu, and in Choansan neighborhood Park in Dobong-gu. The forest swamp in Jatjul Park gets its water from Mt. Maebong and it is a former escalated farmland-turned wetland. The swamp area is $2,500m^2$, a forest zone and a landscape planting site are 83.27% and 6.70% each. Target species Seoul pond frogs are inseparable from rice fields because they live in a short radius of and lay eggs in or near paddy fields, and Rana nigromaculata have similarities with Rana plancyi chosenica in choosing their habitats. There was need for paths that would lead to other paths so amphibians would spread to other parts of the forest and for measures to secure open water. Modifying a variety of routes for water, human and animals along with building a buffer to keep the core habitation zones were required. The forest swamp in Yeonji neighborhood Park used to be a water reservoir on the foot of Mt. Gunji. The swamp area is $1,980m^2$, a forest zone and farmland account for 80.61% and 4.88% each. Non-point pollutants from upstream along run into the subject forest marsh, bare ground on the around swamp and steep stone embankments obstructed amphibians. Target species was Bufo gargarizans that live in forests and edges of hills and spawn in deep water. The forest swamp in Choansan neighborhood Park gets its water from Mt. Choan and it is close to its water source that it is a mountain stream forest wetland. The basin and the swamp are $35,240m^2$ and $250m^2$ in size respectively. A forest zone accounts for 90.20%, high stone embankments laid in refurbishing the valley obstruct amphibians and there is water shortage in times of droughts. Target species were Rana coreana, Rana dybowskii and Hynobius leechii that live in mountain valleys, streams and wetlands and lay eggs in forest marshes and rocks in valleys. Looking into the three swamps of amphibian habitation, I came to conclusions that those wetlands were suitable for their amphibians but man-made facilities blocked their corridors leading to other corridors and even killed off target species in some parts of those swamps by destroying those parts. Amphibians live in water, on ground and underground at different stages of life. Hence, we should take this fact into consideration when planning their habitats and design core habitation zones, buffers zone and use zones accordingly. Buffer zones ought to be between core habitation zones and surrounding trees. Aiming at protecting core habitation zones, buffers should be in harmony with habitation zones. Use zones should be minimized in size and not in direct contact with core habitation zones.

An Experimental Study on the Failure of a Novel Composite Sandwich Structure (새로운 형상의 복합재 샌드위치 체결부 구조의 파손거동 연구)

  • Kwak, Byeong-Su;Kim, Hong-Il;Dong, Seung-Jin;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • The failure of composite sandwich structures with thickness and material variation was studied. The main body of the structure is sandwich plate made of the carbon composite face and Aluminum honeycomb core. It is connected with composite laminated flange without core through transition region of tapered sandwich panel with foam core. Tension and compression tests were conducted for the total of 6 panels, 3 for each. Test results showed that the panels under compression are vulnerable to the face failure along the material discontinuity line between two different cores. However the failure load of which panel does not show such failure can carry 16% more load and fails in honeycomb core and face debonding. For the tensile load, the extensive delamination failure was observed at the corner radius which connects the panel and the flange. The average failure load for compression is about 7 times the tensile failure load. Accordingly, these sandwich structures should be applied to the components that endure the compressive loadings.

Development of Hardware for the Architecture of A Remote Vital Sign Monitor (무선 체온 모니터기 아키텍처 하드웨어 개발)

  • Jang, Dong-Wook;Jang, Sung-Whan;Jeong, Byoung-Jo;Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2549-2558
    • /
    • 2010
  • A Remote Vital Sign Monitor is an in-home healthcare system designed to wirelessly monitor core-body temperature. The Remote Vital Sign Monitor provides accuracy and features which are comparable to hospital equipment while minimizing cost with ease-of-use. It has two parts, a bandage and a monitor. The bandage and the monitor both use the Chipcon2430(CC2430) which contains an integrated 2.4GHz Direct Sequence Spread Spectrum radio. The CC2430 allows Remote Vital Sign Monitor to operate at over a 100-foot indoor radius. A simple user interface allows the user to set an upper temperature and a lower temperature that is monitored with respect to the core-body temperature. If the core-body temperature exceeds the one of two defined temperatures, the alarm will sound. The alarm is powered by a low-voltage audio amplifier circuit which is connected to a speaker. In order to accurately calculate the core-body temperature, the Remote Vital Sign Monitor must utilize an accurate temperature sensing device. The thermistor selected from GE Sensing satisfies the need for a sensitive and accurate temperature reading. The LCD monitor has a screen size that measures 64.5mm long by 16.4mm wide and also contains back light, and this should allow the user to clearly view the monitor from at least 3 feet away in both light and dark situations.

Effect of scratches on optical connector interface surface on the insertion loss (광 커넥터 접합면의 스크래치가 삽입손실에 미치는 영향)

  • 윤영민;윤정현;김부균;신영곤;송국현
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.287-292
    • /
    • 2004
  • This paper presents the effect of scratches on an optical connector interface surface on the insertion loss of optical connectors. We propose a model for calculating the insertion loss of optical connectors. The model is expressed in terms of geometrical parameters of scratches assuming that the transmission coefficient of a light wave on the scratch surfaces is linearly varied as a function of scratch depth. Geometrical parameters of scratches such as location, width, and depth of scratches are measured using 3D optical interferometry surface profiler. We obtain the equation of the transmission coefficient in terms of scratch depth comparing the experimental insertion loss data to the insertion loss data using the model presented in this paper. Using the model and the equation of the transmission coefficient presented in this paper, we present the results of the insertion loss of optical connectors for various geometrical parameters of scratches. Scratches which are located at longer than two times the core radius from the center of the core show negligible effect on the insertion loss of optical connectors.

Tunable Optical Delay Line Based on Polymer Single-Ring Add/Drop Filters and Delay Waveguides (폴리머 단일 링 Add/Drop 필터와 지연 도파로로 구성된 튜닝 가능 광 신호 지연기)

  • Kim, Kyoungrae;Moon, Hyunseung;Chung, Youngchul
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.5
    • /
    • pp.174-180
    • /
    • 2016
  • A tunable optical delay line is designed, fabricated, and characterized. The tunable delay line consists of four polymer-ring add/drop filters with delay waveguides between adjacent ones. The polymer waveguide is a buried structure, designed to be square with core width and height of $1.8{\mu}m$. The refractive indices of the core and cladding polymer are 1.48 and 1.37 respectively. The large index difference and small cross section of the waveguide enable us to realize a compact device using a small radius of curvature. Four pairs of electrodes are evaporated above the add/drop filters to provide heating currents for thermal tuning. In measurements we can identify variable time delays of 110, 225, and 330 ps in proportion to the number of delay lines.

Annealing Effect and Stress for Ultra-Thin 3%Si-Fe Strip Wound Cores (극박방향성 규소강판 권자심 제작에 따른 응력과 열처리효과)

  • 김영학
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.4
    • /
    • pp.185-191
    • /
    • 1998
  • Magnetic domain structure and static magnetic properties were investigated in the ultra thin 3%Si-Fe strip wound cores when the strips were wound and annealed to relief the stress. The elastic and plastic deformation due to the radius of curvature was also investigated for the cores. At the as-wound state, the maze pattern domain structure was generated on the concave surface of the core and 180$^{\circ}$ domain wall was recovered by annealing 600 $^{\circ}C$$\times$30 min. After annealed by 900 $^{\circ}C$$\times$30 min, Hc of strip-wound cores was not reached to the $H_c$ of the strip even at the cores of elastic deformation region. It is necessary to relief the local stress remained in the core when the cores were manufactured for the application of ultra-thin 3%Si-Fe strip.

  • PDF