• Title/Summary/Keyword: Copper Ion

Search Result 504, Processing Time 0.034 seconds

Properties and Functions of Melanin Pigment from Klebsiella sp. GSK

  • Sajjan, Shrishailnath S.;Anjaneya, O;Kulkarni, Guruprasad B.;Nayak, Anand S.;Mashetty, Suresh B.;Karegoudar, T.B.
    • Microbiology and Biotechnology Letters
    • /
    • v.41 no.1
    • /
    • pp.60-69
    • /
    • 2013
  • Purified melanin pigment from Klebsiella sp. GSK was characterized by thermogravimetric, differential thermal, X-ray diffraction and elemental analysis. This melanin pigment is structurally amorphous in nature. It is thermally stable up to $300^{\circ}C$ and emits a strong exothermic peak at $700^{\circ}C$. Its carbon, hydrogen and nitrogen composition is 47.9%, 6.9% and 12.0%, respectively. It was used to scavenge metal ions and free radicals. After immobilizing the pigment and using it to adsorb copper and lead ions, the metal ion adsorption capacity was evaluated by atomic absorption spectroscopy (AAS) and the identity of melanin functional groups involved in the binding of metal ions was determined by Fourier transform infrared (FT-IR) spectroscopy. Batch adsorption studies showed that 169 mg/g of copper and 280 mg/g of lead were adsorbed onto melanin-alginate beads. The metal ion adsorption capacity of the melanin-alginate beads was relatively significant compared to alginate beads. The metal ion desorption capacity of HCl was greater (81.5% and 99% for copper and lead, respectively) than that of EDTA (80% and 71% for copper and lead, respectively). The ability of the melanin pigment to scavenge free radicals was evaluated by inhibition of the oxidation of 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and was shown to be about 74% and 98%, respectively, compared with standard antioxidants.

Solvent Extraction of Copper from $CuCl_2-NiCl_2-CoCl_2$ Solutions by Alamine336 and LIX84 ($CuCl_2-NiCl_2-CoCl_2$용액으로부터 Alamine336과 LIX84에 의한 구리의 용매추출)

  • Lee Man-Seung;Ahn Jong-Gwan;Ahn Jae-Woo
    • Resources Recycling
    • /
    • v.11 no.6
    • /
    • pp.12-17
    • /
    • 2002
  • Solvent extraction experiments have been performed to separate copper from $CuCl_2$-$NiCl_2$-$CoCl_2$$ solutions using Alamine336 and LIX84. The complex formation tendency between metal ions and chloride ion had a great effect on the distribution coefficients of Cu, Co and Ni ions and separation factor of Cu to Co and Ni. In the experimental ranges of chloride ion concentration from 0.5 to 4.0 M, LIX84 was superior to Alamine336 in separating copper from cobalt. When the volume percentage of LIX84 and Alamine336 was varied from 5 to 40%, LIX84 was more effective than Alamine336 in separating Cu from Co and Ni in solutions in which the chloride ion concentration was 1.0 M.

The influence of Ni ion addition on the microstructure and gamma ray shielding ability of ferromagnetic CuFe2O4 ceramic material

  • Mohammad W. Marashdeh;Fawzy H. Sallam;Ahmed M. Abd El-Aziz;Mohamed I. Elkhatib;Sitah f. Alanazi;Mamduh J. Aljaafreh;Mohannad Al-Hmoud;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2740-2747
    • /
    • 2024
  • The sintering process acquired ferromagnetic copper ferrite ceramic material with a small concentration of Ni ion at 1100 ℃ for 1 h. Previously, copper ferrite with Ni proportions powder was acquired by the wet chemical process according to the relation CuFe2-xNixO4 where x takes values 0.0, 0.015, 0.03, 0.04, and 0.05. The role of Ni ion in the copper ferrite structure was investigated by X-ray analysis, Scanning electron microscope, EDX analysis, and density measurements. The gamma-ray shielding properties for the fabricated CuFeNiO ceramics samples were evaluated using the Monte Carlo simulation method. The obtained results show an enhancement in the linear attenuation coefficient for the fabricated ceramics with increasing the insertions of Ni ions within the fabricated samples, where increasing the Ni ions concentration between 0 and 1.19 wt% increases the linear attenuation by between 1.581 and 1.771 cm-1 (at 0.103 MeV), 0.304-0.338 cm-1 (at 0.662 MeV), and 0.160-0.178 cm-1 (at 2.506 MeV), respectively. Simultaneously, the radiation protection efficiency for a 1 cm thickness of the fabricated samples increased between 14.8 and 16.3% with increasing the Ni ions between 0 and 1.19 wt%. Although the Ni doping concentration does not exceed 1.5 wt% of the total composition of the fabricated ceramics, the shielding capacity of the fabricated ceramics was enhanced by more than 11%, along the studied energy interval. Therefore, the fabricated samples can be used in gamma-ray shielding applications.

Mechanical and Antibacterial Properties of Copper-added Austenitic Stainless Steel (304L) by MIM

  • Nishiyabu, Kazuaki;Masai, Yoshikaze;Ishida, Masashi;Tanaka, Shigeo
    • Journal of Powder Materials
    • /
    • v.9 no.4
    • /
    • pp.227-234
    • /
    • 2002
  • For the austenitic stainless steel (304L) manufactured by metal injection molding(MIM), the effects of copper content and sintering temperature on the mechanical properties, antibacterial activities, corrosion resistance, and electric resistances were investigated. The specimens were prepared by injection molding of the premixed powders of water-atomized 304 L and Cu with poly-acetyl binders. The green compacts were prepared with various copper contents from 0 to 10 wt.% Cu, which were debound thermally at 873 K for 7.2 ks in $N_2$gas atmosphere and subsequently sintered at various temperatures from 1323 K to 1623 K for 7.2 ks in Ar gas atmosphere. The relative density and tensile strength of the sintered compacts showed the minimum values at 5 and 8 wt.% Cu, respectively. Both the relative density and the tensile strength of the specimen with 10 wt.% Cu sintered at 1373 K showed the highest values, higher than those of copper-free specimen. Antibacterial activities investigated by the plastic film contact printing method for bacilli and the quantitative analysis of copper ion dissolved in water increased as the increase of the copper content to stainless steels. It was also verified by the measurement of pitting potential that the copper addition in 304 L could improve the corrosion resistance. Furthermore the electric conductivity increased with the increase of copper content.

Comparison of Heavy Metal Adsorption between Pseudomonas cepacia H42 and Saccharomyces cerevisiae SEY2102 (Pseudomonas cepacia H42와 Saccharomyces cerevisiae SEY2102의 중금속 흡착비교)

  • Park, Ji-Won;Jeong, Yu-Jeong;Ryu, Eun-Ju;Kim, Byung-Woo;Kwon, Hyun-Ju;Lee, Eun-Woo;Lee, Hyun-Tae;Kim, Young-Hee
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1177-1185
    • /
    • 2010
  • To examine the potency of biosorbent, the adsorption capacity of Pseudomonas cepacia H42 isolated from fresh water plant root was compared with Saccharomyces cerevisiae SEY2102 on bases of biomass, concentration of heavy metal, presence of light metals, immobilized cell, and ion exchange resin. P. cepacia H42 biomass of 0.05-0.5 g/L increased adsorption and above 1.0 g/L of yeast biomass was the most effective in adsorption. By applying the same amount of biomass, lead showed the highest adsorption on two strains and the adsorption strength was lead>copper>cadmium on both strains. The high heavy metal concentration induced the high adsorption capacity. P. cepacia H42 adsorption was in the order of copper>lead>cadmium and lead>copper>cadmium by yeast in 10 mg/L. Both strain showed same adsorption strength in the order of lead>copper>cadmium in 100 mg/L and 1000 mg/L. The adsorption capacity of both yeast and P. cepacia H42 was decreased in the presence of light metals and the order of cadmium>copper>lead. $Mg^{2+}$ induced the least adsorption while $Na^+$ induced highest adsorption. The adsorption capacity of immobilized yeast and P. cepacia H42 was detected between 200-400 mL in flow volume and decreased in the presence of light metals. Ion exchange containing light metals caused 30-50% adsorption reduction on both strains.

Nanoscale Fluoropolymer Pattern Fabrication by Capillary Force Lithography for Selective Deposition of Copper

  • Baek, Jang-Mi;Lee, Rin;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.369-369
    • /
    • 2012
  • The present work deals with selective deposition of copper on fluoropolymers patterned silicon (111) surfaces. The pattern of fluoropolymer was fabricated by nanoimprint lithography (NIL) and plasma reactive ion etching (RIE) was used to remove the residuals layers. Copper was electrochemically deposited in bare Si regions which were not covered with fluoropolymers. The patterns of fluoropolymers and copper have been investigated by scanning electron microscopy (SEM). In this work, we used two deposition methods. One is galvanic displacement method and another is electrodeposition. Selective deposition works in both cases and it shows applicability to other materials. By optimization of the deposition conditions can be achieved therefore this process represents a simple approach for a direct high resolution patterning of silicon surfaces.

  • PDF

Research on the copper diffusion process in germanium metal induced crystallization by different thickness and various temperature

  • Kim, Jinok;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.289.1-289.1
    • /
    • 2016
  • Germanium (Ge) with higher carrier mobility and a lower crystallization temperature has been considered as the channel material of thin-film transistors for display applications. Various methods were studied for crystallizaion of poly-Ge from amorphous Ge at low temperature. Especially Metal induced crystalliazation (MIC) process was widely studied because low process cost. In this paper, we investigate copper diffusion process of different thick (70 nm, 350 nm) poly-Ge film obtained by MIC process at various temperatures (250, 300, and $350^{\circ}C$) through atomic force microscopy (AFM), Raman spectroscopy, and secondary ion mass spectroscopy (SIMS) measurement. Crystallization completeness and grain size was similar in all the conditions. Copper diffusion profile of 370 nm poly-Ge film show simirly results regardless of process temperature. However, copper diffusion profile of 70 nm poly-Ge film show different results by process temperature.

  • PDF

Oxidative Modification of Human Ceruloplasmin by Methylglyoxal: An in vitro study

  • Kang, Jung-Hoon
    • BMB Reports
    • /
    • v.39 no.3
    • /
    • pp.335-338
    • /
    • 2006
  • Methylglyoxal (MG) is an endogenous physiological metabolite which is present in increased concentrations in diabetics. MG reacts with the amino acids of proteins to form advanced glycation end products. In this in vitro study, we investigated the effect of MG on the structure and function of ceruloplasmin (CP) a serum oxidase carrier of copper ions in the human. When CP was incubated with MG, the protein showed increased electrophoretic mobility which represented the aggregates at a high concentration of MG (100 mM). MG-mediated CP aggregation led to the loss of enzymatic activity and the release of copper ions from the protein. Radical scavengers and copper ion chelators significantly prevented CP aggregation. CP is an important protein that circulates in plasma as a major copper transport protein. It is suggested that oxidative damage of CP by MG may induce perturbations of the copper transport system and subsequently lead to harmful intracellular condition. The proposed mechanism, in part, may provide an explanation for the deterioration of organs in the diabetic patient.

Experimental Determination of Equilibrium Constants of Copper Complexes in Aqueous Environment

  • Cho, Young-Il
    • Journal of Environmental Science International
    • /
    • v.21 no.5
    • /
    • pp.555-562
    • /
    • 2012
  • The experimental determination of equilibrium constants is required to estimate concentrations of reagents and/or products in environmental chemical reactions. For an example, the choice of copper (Cu) complexation reactions was motivated by their fast kinetics and the ease of measurement of Cu by an ion-sensitive electrode. Each individual titrant of sulfate ($SO{_4}^{2-}$) and oxalate ($C_2O{_4}^{2-}$) was expected to have its own unique characteristics, depending on the bonding in Culigands connected to the aqueous species. The complexation reaction of Cu with $SO{_4}^{2-}$ somewhat fast reached equilibrium status compared with $C_2O{_4}^{2-}$. The experimental equilibrium constants ($K_{eq}$) of copper sulfate ($CuSO_4$) and copper oxalate ($CuC_2O_4$) were determined $10^{2.2}$ and $10^{3{\sim}4.3}$, respectively.