• 제목/요약/키워드: Coplanar compounds

검색결과 11건 처리시간 0.052초

Passive Air Sampler (PAS)와 기체/입자 분배모델을 이용한 대기 중 PCB 농도 산정 (Estimation of Air Concentrations of PCBs using Passive Air Samplers (PAS) and a Gas/particle Partition Model)

  • 백송이;최성득;장윤석
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.734-743
    • /
    • 2007
  • Polyurethane foam-disk passive air samplers (PAS) were deployed in a southern area of Korea for three months. The target compounds were 12 coplanar polychlorinated biphenyls (PCBs). The congener profiles measured in this study were the same as those in ambient air and emission gas from the incinerator. A gradient of the total PCBs in different regions (industrial>residential>rural) was observed, suggesting the industrial complex may be an important source of coplanar PCBs. In general, only gas-phase compounds are mainly sequestrated by PAS. In order to estimate the concentration of particle-phase PCBs, a gas/particle partition model was used. A combined result (gas+particle-phase PCBs) was compared with previous results, indicating that the level of coplanar PCBs in our study area is comparable to those in other urban sites in the world. The validation of this method for estimating the total concentration is required through additional backup studies.

Synthesis and Characterization of Tetrathiafulvalene-Based Smectic Liquid Crystals

  • Wang, Lei;Kim, Young-Gook;Jeong, Kwang-Un;Lee, Myong-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1389-1392
    • /
    • 2009
  • A series of new symmetric TTF derivatives were designed and synthesized. This facile synthetic method provides an opportunity to prepare TTF-based LC candidates. This series of compounds exhibited smectic A phase based on coplanar TTF core. One of the LC compounds was used as a semiconductor layer to fabricate OTFT.

  • PDF

Synthesis, Cytotoxicity and Topoisomerase II Inhibitory Activity of Benzonaphthofurandiones

  • Rhee, Hee-Kyung;Kwon, Young-Joo;Chung, Hwa-Jin;Lee, Sang-Kook;ParkChoo, Hea-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권7호
    • /
    • pp.2391-2396
    • /
    • 2011
  • Benzonaphthofurandiones containing four coplanar fused aromatic rings were synthesized and evaluated for their cytotoxicity against five human cancer cell lines, and their inhibitory activity on topoisomerases. These benzonaphthofurandiones were prepared by condensation of 2,3-dichloronaphthoquinone and three aromatic diols with base catalysts in alcohol. The synthesized compounds were o-alkylated with six dialkylaminoalkyl halides. The hydroxy derivatives (8a-8g) exhibited relatively potent cytotoxicity among the prepared compounds. These compounds were evaluated as excellent inhibitors against topoisomerase II (topo II). Especially, the hydroxy analogue with branched methyl side chain (8e) showed high cytotoxicity against cancer cell lines and good inhibitory activity on topo II.

Assessment of Environmental Pollution in Korean Stream Sediments by Chemical Analyses and Insect Immune Biomarkers

  • Ryoo, Keon-Sang;Byun, Sang-Hyuk;Hong, Yong-Pyo;Cho, Ki-Jong;Bae, Yeon-Jae;Kim, Yong-Gyun
    • 환경생물
    • /
    • 제26권4호
    • /
    • pp.330-342
    • /
    • 2008
  • A comprehensive quality survey for PCDDs/PCDFs and coplanar PCBs as well as heavy metals (Cu, Zn, Cd and Pb) in sediments has been investigated in August 2006, Korea. Monitoring was undertaken at five streams representing different surrounding environments throughout Juwang and Gapyeong streams (reference sites), Jungrang stream (dense population site), Ansan stream (mixed small population and industrial site), and Siheung stream (heavy industrial site). The levels of heavy metal in samples were found to be significantly higher in sediment from Siheung stream compared to those of other stream sites. The heavy metal concentrations (dry weight basis) in sediment from Siheung stream were as follows; Cd (3.7 ${\mu}g$/g), Pb (1,295 ${\mu}g$/g), Cu (713.4 ${\mu}g$/g) and Zn (358.1 ${\mu}g$/g). Among 12 coplanar PCBs and 17 PCDDs/PCDFs selected as target compounds in this study, PCB (IUPAC no. 118) and OCDD were the most abundant congeners found in all sediment samples, followed by 1,2,3,4,6,7,8-HpCDD, OCDF and 1,2,3,4,6,7,8HpCDF as well as PCB (IUPAC no. 105). These results were shown to be in the same trend as the sediment samples of other countries. The levels of PCDDs/PCDFs/coplanar PCBs in sediment samples were expressed as concentrations and WHO- TEQ values. The PCDDs/PCDFs/coplanar PCBs concentrations and their WHO-TEQ values in sediment from Siheung stream were remarkably high. The levels detected were 788.16 pg/g and 36.080 pg WHO-TEQ/g dry weight for PCDDs/ PCDFs and 314 pg/g and 0.4189 pg WHO-TEQ/g dry weight for coplanar PCBs, respectively, beyond the safety level of sediment value 20 pg WHO-TEQ/g. Sediment samples of the five streams were also monitored by sensitive biomarkers using insect immune responses: hemocyte-spreading behavior and immune-associated enzyme activities of phospholipase A$_2$ (PLA$_2$) and phenoloxidase. Organic extracts of Siheung and Jungrang sediments significantly interfered with the hemocytespreading behavior, whereas those of Ansan, Gapyeong, and Juwang did not. These organic extracts did not inhibit the PLA$_2$ and phenoloxidase activities. However, phenoloxidase was highly susceptible to exposure to aqueous extracts in all site sediments. In comparison, PLA$_2$ activities of the hemocytes were significantly inhibited only by aqueous extracts of Siheung, Jungrang, and Gapyeong sediments, but not by those of Ansan and Juwang. Despite some disparity between bioand chemical monitoring results, the biomarkers can be recommended as a device warning the contamination of biohazard environmental chemicals because of a fast and inexpensive detection method.

토양의 이화학적 특성이 PCBs 분석에 미치는 영향 (The Effects of Physico-chemical Properties of soils on PCBs Analysis)

  • 김태승;신선경;장준영
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.48-58
    • /
    • 2003
  • 본 이화학적 특성이 다른 토양 중 PCBs 분석에 대해 연구하기 위해, 세 종류의 우리나라 토양을 선정하여 용매별 (톨루엔, 아세톤:헥산, 디클로로메탄) 추출효율을 조사하였다. 또한, 실리카겔, 플로리실 및 알루미나 정제 컬럼을 이용한 용출패턴 특성을 조사하였으며, 현재 이용되고 있는 미국, 일본 및 우리나라 PCBs 시험방법을 우리나라 토양에 적용하여 분석결과를 비교하였다. 토양 중 62종의 PCBs 용매별 추출효율은, 톨루엔의 경우 토양 A, 토양 B 및 토양 C에 대하여 평균회수율은 각각 77.94%, 53.65% 및 44.52%로 나타났다. 아세톤:헥산 (1:1)의 경우에는 토양에 따라 각각 58.59%, 80.32% 및 60.35%로 나타났으며, 디클로로메탄의 경우에는 각각 54.20%, 68.27% 및 56.36%로 나타났다. PCBs 분석을 위한 정제컬럼별 용출효율은, 실리카겔의 경우 1Cl에서 10Cl의 평균회수율이 89.67% (1Cl)~44.85% (8Cl)로 나타났으며, 플로리실의 경우 1Cl에서 10Cl의 평균 회수율은 67.00% (8Cl)~98.26% (10Cl)로 나타났다. 또한, 알루미나의 경우 알루미나 I은 1Cl에서 10Cl의 평균 회수율은 63.01% (9Cl)~88.17% (1Cl)로 나타났으며, 알루미나 II는 1Cl에서 10Cl의 평균 회수율은 61.40% (7Cl)~80.78% (1Cl)로 나타났다. 미국, 일본 및 본 연구의 시험방법을 비교한 결과, 토양 A에 대한 62종의 PCBs의 평균회수율은 각각 37.15%, 45.92% 및 44.46%로 나타났으나, 시험방법에 따라 개별 피이크의 회수율은 비교적 큰 차이를 보이고 있다.

국내 하천들의 수질, 하천 퇴적물, 주변 토양 및 별늑대거미 체내 중금속 축적량을 통한 환경오염도 평가 (Assessment of Environmental Contaminant Levels in Water, Sediments and Adjacent Soils and Spider from Several Stream Sites in Korea)

  • 변상혁;유건상;최종하;김용균;이화성
    • 한국환경과학회지
    • /
    • 제17권3호
    • /
    • pp.287-296
    • /
    • 2008
  • A comprehensive quality survey for heavy metals, organophosphorous and organochlorine residual pesticides, and coplanar PCBs in samples such as water, sediments and soils as well as spiders has been implemented. The samples were undertaken at nine stream sites and their vicinity in August 2006, representing different surrounding environments. The levels of PCBs were expressed as concentrations and WHO-TEFs. Among 12 coplanar PCBs as target compounds in this study, 2,3', 4,4', 5-PentaCB (IUPAC # 118) was the congener with the highest concentration. The total concentrations and TEF values of coplanar PCBs in Siheung stream sediment (heavy industrial complex site located in Ansan city) were 3915.50 pg/g and 0.8366 pg-TEQ/g on a dry weight basis, respectively. Such levels were around 40 times higher compared to sediment from Gapyung stream (green site located in the upper of Myunggi mountain). It is probably due to the direct input of PCBs trom PCBs treatment materials. Organophosphorous (EPN, dementon-s-methyl, diazinon, parathion, and phenthoate) and organochlorine (alpha-BHC, aldrin, 4,4'-DDT, 4,4'-DDE, endosulfan alpha and etc.) pesticides were not detected above 5 ppb of detection limits. The concentrations of Cu and Cd in water and sediment samples from Siheung stream were 44.11 and $0.17ug/m\ell$ and $713.42{\mu}g/g$ and $3.73{\mu}g/g$, respectively, which contained $20\sim40$ times higher concentrations than those from Gapyung stream. In addition to the water and sediment samples, the levels of heavy metals in spider from designated sampling sites were also determined. Heavy metals in spider collected near Siheung stream was appeared to be equivalent and/or a little higher levels with respect to other spiders. Furthermore, the ratio of relative heavy metals (Cu, Cd, and Pb) in spider from each stream site showed a correlation as similar as that of heavy metals in soil samples.

Impurity Profiling and Quantification of Sudan III Dyes by HPLC-selective UV Detection

  • Yang, Ki Ryeol;Hong, Ji Yeon;Yoon, Soo Hwan;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.765-769
    • /
    • 2014
  • An analytical methodology was developed for qualitative and quantitative impurity profiling of the coloring agent Sudan III by high-performance liquid chromatography (HPLC)-diode array detection (DAD). The impurities in commercial Sudan III were characterized by comparison of their retention times and UV spectra with those of authentic standards. Four impurities regulated by International Committees in Sudan III were quantified by HPLC-selective UV detection. The impurities in Sudan dye were successfully separated on a reversed phase C18-column within 25 min and sensitively detected by UV spectrometry at two selective wavelengths. Method validation was conducted to determine linearity, precision, accuracy, and limit of quantification (LOQ). The linear dynamic range extended from 0.002 to 4.0%, with a correlation coefficient (R2) greater than 0.995. The LOQs of the impurities ranged from 8.04 to $54.29{\mu}g/mg$. Based on the established method, the levels of regulated impurities in five commercial Sudan III dyes were determined.

동위원소희석법 HRGC/HRMS에 의한 식품 중 Co-planar PCBs 분석 (Analyzing Co-planar PCBs in Food by HRGC/HRMS with Isotopic Dilution Method)

  • 최동미;서정혁;김민정;홍무기;김창민;송인상
    • 분석과학
    • /
    • 제16권4호
    • /
    • pp.325-332
    • /
    • 2003
  • 고분해능질량분석기를 이용한 동위원소희석법으로 식품 중 co-planar PCBs의 분석을 시도하였다. 시료를 균질화하여 추출 후 실리카겔 및 알루미나 컬럼으로 정제를 하여 HRGC/HRMS로 분리능 10,000에서 분석하였다. 대상물질은 세계보건기구인 WHO에서 다이옥신류와 유사한 독성이 있다고 평가한 non-ortho co-planar PCB #77, #81, #126 및 #169 4종 및 mono-ortho coplanar PCBs #105, #114, #118, #123, #156, #157, #167 및 #189 8종을 포함한 12종 이었다. 대상시료는 시중에 유통 중인 우유 및 유제품을 선택하였다. 분석 결과 평균 회수율은 83~106%이었고 검출한계는 신호대잡음비 (signal/noise, S/N) >3에서 0.1 pg/g이었으며 식품시료 중 검출된 대상물질은 0.001~0.107 pgWHO-TEQ/g 수준이었다.

PYE [2-(1-pyrenyl)ethyldimethylsilylated silica] Column HPLC and HR-GC-(micro) ECD in the Accurate Determination of Toxic Co-planar PCBs and Polybrominated Diphenyl Ethers (PBDEs)

  • Kannan, Narayanan;Hong, Sang-Hee;Oh, Jae-Ryoung;Yim, Un-Hyuk;Li, Donghao;Shim, Won-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.529-536
    • /
    • 2005
  • Measurement of toxicologically relevant polychlorinated biphenyl (PCB) congeners such as non-ortho(IUPAC#) 77, 81, 126, 169 and mono-ortho 105, 114, 118, 123, 156, 157, 189 and di-ortho 170, 180 and polybrominated diphenyl ethers (PBDEs) such as 47, 66, 85, 99, 100, 138, 153, 154 in environmental samples become almost mandatory in several countries now. However, most of the available methods involve expensive instrumentations such as HRGC-HRMS or ECNI-LRMS, apart from expensive extraction and clean-up (with large volume of solvents) steps. A method has been devised combining the analytical separation power of PYE [2-(1-pyrenyl)ethyldimethysilylated silica] column HPLC and high-resolution gas chromatographic techniques including micro-electron capture detection (ECD) and two dimensional gas chromatograpy-ECD techniques to determine these eco-toxic substances at parts-per-trillion (ppt) levels. This combination resolves co-elution of congeners that occur in disproportionate ratios (e.g. CB-110 and -77) and allows accurate congener-specific determination of target compounds. This method is cost effective as it requires only hexane, that in small quantities (10 mL) and GC-ECD. The elution and analysis time are optimized to less man hours. This method is effectively utilized in the analysis of co-planar PCBs and PBDEs from archived solvent extracts of samples previously analyzed for pesticides and PCBs. Structure based separation of contaminant classes improves GCECD determination at ppt levels.

Two Polymorphs of Structures of $\alpha,\alpha$-Trehalose Octaacetate Monohydrate

  • Park, Young-Ja;Shin, Jung-Mi
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권2호
    • /
    • pp.200-206
    • /
    • 1993
  • Structures of two polymorphs of ${\alpha},{\alpha}$-trehalose octaacetate monohydrate, $C_{28}H_{38}O_{19}\;{\cdot}\;H_2O$, have been studied by X-ray diffraction method. ${\alpha},{\alpha}$-trehalose (${\alpha}$-D-glucopyranosyl ${\alpha}$-D-glucopyranoside) is a nonreducing disaccharide. The polymorph I belongs to the monoclinic $P2_1$, and has unit cell parameters of a=10.725(l), b=15.110(4), c=11.199(5) ${\AA}$, ${\beta}=108.16(2)^{\circ}$ and Z=2. The polymorph II is orthorhombic $P2_12_12_1$, with a=13.684(4), b=15.802(4), c=17.990(9) ${\AA}$ and Z=4. The final R and R$_w$ values for monoclinic polymorph I are 0.043 and 0.048 and for orthorhombic polymorph II are 0.116 and 0.118, respectively. Those R values of polymorph II are high because the large thermal motions of acetyl groups and the poor quality of the crystal. The molecular conformations in the two polymorphs are similar. Both D-glucopyranosyl rings have chair $^4C_1$ conformations and atoms of glycosidic chain ${\alpha}(1{\rightarrow}1)$ linkage are coplanar. The primary acetate groups of the pyranose residues assume both gauche-trans conformations. The molecules of two polymorphs have pseudo-C$_2$ symmetry at glycosidic O(1) atom. The bond lengths and angles are normal compared with those in other acetylated sugar compounds. The molecules in the monoclinic crystal are held by the hydrogen bonds with the water molecules and by van der Waals forces.