• Title/Summary/Keyword: CopA3

Search Result 435, Processing Time 0.029 seconds

Test-retest Reliability of Sit-to-Stand and Gait Assessment Using the Wii Balance Board (Wii Balance Board를 이용한 Sit-to-Stand와 보행기능 측정의 검사-재검사 신뢰도)

  • Yang, Seong-rye;Oh, Yu-ri;Jeon, Ye-rim;Park, Dae-sung
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2016
  • Background: Assessments of Sit-to-Stand (STS) and gait functions are essential procedures in evaluating level of independence for the patients after stroke. In a previous study, we developed the software to analyze center of pressure (COP) in standing position on Wii Balance Board (WBB). Objects: This purpose of this study is to measure test-retest reliability of ground reaction forces, COP and time using WBB on STS and gait in healthy adults. Methods: Fifteen healthy participants performed three trials of STS and gait on WBB. The time (s), vertical peak (%) and COP path-length (cm) were measured on both tasks. Additionally, counter (%), different peak (%), symmetry ratio, COP x-range and COP y-range were analyzed on STS, 1st peak (%), 2nd peak (%) of weight were analyzed on gait. Intra-class correlation coefficient (ICC), standard error measurement (SEM) and smallest real difference (SRD) were analyzed for test-retest reliability. Results: ICC of all variables except COP path-length appeared to .676~.946 on STS, and to .723~.901 on gait. SEM and SRD of all variables excepting COP path-length appeared .227~8.886, .033~24.575 on STS. SEM and SRD excepting COP path-length appeared about .019~3.933, .054~11.879 on gait. Conclusion: WBB is not only cheaper than force plate, but also easier to use clinically. WBB is considered as an adequate equipment for measuring changes of weight bearing during balance, STS and gait test which are normally used for functional assessment in patients with neurological problems and elderly. The further study is needed concurrent validity on neurological patients, elderly patients using force plate and WBB.

Consideration of Energy Consumption with Respect to the Position of Refrigerator in a Room (냉동냉장고의 실내위치에 따른 에너지 소비량의 변화에 관한 연구)

  • Nam Pyung Woo;Lee Jae Heon;Park Man Heung;Kim Suk Hyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.200-211
    • /
    • 1985
  • The paper discusses the problem of the reduction in Coefficient of Performance (COP) in a refrigerator due to the inadequate position or some flow obstacles such as shelves in a room. The propriety of the present numerical method has teen proved by experiments using the flow visualization technique. The COP are calculated from the temperature rise of the condenser whose temperature indicates the condensing temperature of refrigerant The temperature rise is predicted by the theory of the steady two-dimensional laminar natural convection. In a room size of $2m\;{\times}\;2m$ the COP are decreased by 0.3 when the gap between the wall and condenser are decreased from 10cm to 2cm. While the COP are decreased by 0.55 as the shelf length increases from 0 to 75cm.

  • PDF

Effects of Robotic Gait Training with Lower Extremity Restraint on Static Balance, Lower Extremity Function, Gait Ability in Subacute Stroke Patients

  • Kang, Yun-Su;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.270-277
    • /
    • 2021
  • Objective: The purpose of this study is to compare the effect of static balance, lower extremity function, and gait ability between a lower extremity restrain robot gait training and a general robot gait training in subacute stroke subjects. Design: Two-group pretest-posttest design. Methods: A total of 12 subacute stroke patients were randomly divided into an Experimental group (n=6) and a control group (n=6). Both groups were performed for four weeks, three times a week, for 20 minutes. To compare the Static balance function, the center of pressure (COP) path-length and COP velocity were measured. The Fugl-Meyer assessment lower extremity (FMA-LE) were evaluated to compare the Lower Extremity function. 2D Dartfish Program and 10 Meter Walking Test (10 MWT) on Gait ability were evaluated to compare the gait function. Results: In the intra-group comparison, Experimental groups showed significant improvement in COP path-length, velocity, Lower Extremity Function, 10 MWT, Cadence, by comparing the parameters before and after the intervention (p<0.05). Comparison of the amount of change between groups revealed significant improvement for parameters in the COP path-length, velocity, Lower extremity function, 10 MWT by comparing the parameters before and after the intervention (p<0.01). Conclusions: The Experimental group showed enhanced efficacy for variables such as COP path-length, velocity, Lower extremity function, 10 MWT as compared to the control group.

Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment (공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가)

  • LEE, C.H.;Nah, H.S.;JUNG, H.;Kim, K.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

Attachment of the Air Heat Exchanger for COP Improvement in the Heat Pump (열펌프 성능향상을 위한 공기 열교환기 부착효과)

  • 노정근;송현갑;박용규
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.235-240
    • /
    • 2002
  • Performance of the heat pump with attaching an air heat exchanger was investigated in the heating condition when the air heat exchanger was worked in the ambient air temperature of -5 to 11$\^{C}$ and air flow rate of 542 to 747 ㎡/h. Performance tests for heating condition were conducted in an experimental room equipped with heat pump. The performance tests were performed in a ambient temperature of -4 ∼ 11$\^{C}$, and room temperature of 4∼22$\^{C}$ respectively. Measured data(temperature, capacity of heat transfer and consumption of electronic power) were analyzed to the efficiency of HEEVA(Heat Exchanger fur the Evaporator), overall heat transfer coefficient and COP of heat pump. The results of inlet temperature for evaporator increased that the temperature was 2 ∼6$\^{C}$, and inlet temperature for condenser decreased that the temperature was 3 ∼ 8$\^{C}$. The results of comparing efficiency of HEEVA for the ratio of heat exchange between hot air and cold air showed that efficiency were considered to 91% because of the ratio of 83∼98%. The results of comparing of COP for the heat pump increased that improvement COP was approximately 0.3∼7.5 than HEEVA had not been operated.

An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System (가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구)

  • Kong, Hyoung Jin;Kang, Sung Jae;Yun, Kyoung Sik;Lim, Hyo Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

Effects of Ankle and Hip Strategy Training on Improving the Center of Pressure Movements and Limits of Stability in Stroke Patients

  • Park, Shinjun;Park, Sunghyun;Kim, Yongyoun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1823-1829
    • /
    • 2019
  • Background: Stroke patients have leg muscle weakness and impaired balance resulting in compensatory changes. To restore balance in these patients, functional training using postural strategy is needed. Objective: To examine the effects of ankle and hip strategy training on the center of pressure (COP) movement and limits of stability (LOS) in standing posture in stroke patients. Design: The study was an assessor-blinded and randomized-controlled clinical trial. Methods: Thirty patients were randomly assigned to an ankle strategy training group and a ankle/ hip strategy training group. Patients in the ankle strategy training group underwent ankle strategy exercise for 30 min, and those in the ankle/ hip strategy training group underwent 15 min of ankle strategy exercise and 15 min of hip strategy exercise. Both groups underwent training thrice a week for four weeks. Forward, backward, paretic side, and non-paretic side COP movements and LOS were measured using BioRescue. Results: After the intervention, except for the backward area in the ankle strategy training group, the COP movement area and the LOS were significantly improved in both the groups. In addition, these improvements were significantly higher in ankle/ hip strategy training group than that in the ankle strategy training group. Conclusions: Ankle strategy training in addition to hip strategy training improves COP movement (forward-backward, paretic side area, and non-paretic side area) and LOS in stroke patients.

Effect of ankle joint taping treatment on lower extremity joint and center of pressure factors during the Uchi-mata (허벅다리걸기 동작 시 발목 관절의 테이핑 처치가 하지 관절과 압력 중심 요인들에 미치는 영향)

  • Yun, Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.224-231
    • /
    • 2020
  • The purpose of this study was to analyze the effect of ankle joint taping treatment on lower extremity joint and center of pressure(COP) factors during the Uchi-mata. Twenty college judo athletes (age, 20.9 ± 0.8 years; height, 168.6 ± 7.4cm; weight, 73.5 ± 11.6kg; body mass index, 25.7 ± 2.6kg/㎡) participated, and two types before and after ankle joint taping treatment when the during the Uchi-mata was exhibited under conditions, the angle and COP factors of the support leg joints were analyzed to show the following results. At the time of E2 (t = 2.411, p = .027) E4 (t = 2.388, p = .029), the ankle joint angle was statistically less after the treatment than before the taping treatment, and E2 (t = -2.343, p = .032) At E3 (t = -4.531, p = .000), the angle of the hip joint was statistically large. And after the ankle joint taping treatment, the medial/lateral COP movement after the ankle joint taping treatment was statistically large in the P3 phase of throwing the opponent (t = 2.670, p = .016), and the anterior/posterior COP movement showed a statistically small number in the P1 phase where the opponent was tilted (t = 2.846, p = .011). Therefore, it was suggested that judo athletes who use thighs as a special technique should be used considering the movement function of the support joint and the range of movement of the COP caused by tapping of the ankle joint.

Performance Evaluation of R-22 Alternative Refrigerants with Hydrofluorocarbon and Hydrocarbon (HFC 및 탄화수소를 포함한 R-22 대체냉매의 성능평가)

  • 김창년;박영무;이병권;임종성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.315-324
    • /
    • 2000
  • R-410A, R-407C, and four refrigerant mixtures composed of R-32, R-l34a, R-l43a, R-l52a, R-600(butane), and R-600a(isobutane) were tested in an attempt to replace R-22 used in most of the residential air conditioners. The performance evaluation was carried out in a psychrometric calorimeter test facility using a residential spilt type air conditioner under the KS rating conditions. Except for the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; COP, capacity, compressor power, and VCR. R-410A was shown to have 5.5% higher COP and 3.5% lower capacity than R-22. R-32/134a/600a (42.8/ 46.0/11.2 wt%) mixture have the best performance among the four refrigerant mixtures composed of hydrofluorocarbon and hydrocarbon. This inixture have 3.0% lower COP and 1.6% lower capacity than R-22.

  • PDF

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF