A Multi-Dimensional Node Pairing Scheme for NOMA in Underwater Acoustic Sensor Networks (수중 음향 센서 네트워크에서 비직교 다중 접속을 위한 다차원 노드 페어링 기법)

  • Cheon, Jinyong;Cho, Ho-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.1-10
    • /
    • 2021
  • The interest in underwater acoustic sensor networks (UWASNs), along with the rapid development of underwater industries, has increased. To operate UWASNs efficiently, it is important to adopt well-designed medium access control (MAC) protocols that prevent collisions and allow the sharing of resources between nodes efficiently. On the other hand, underwater channels suffer from a narrow bandwidth, long propagation delay, and low data rate, so existing terrestrial node pairing schemes for non orthogonal multiple access (NOMA) cannot be applied directly to underwater environments. Therefore, a multi-dimensional node pairing scheme is proposed to consider the unique underwater channel in UWASNs. Conventional NOMA schemes have considered the channel quality only in node pairing. Unlike previous schemes, the proposed scheme considers the channel gain and many other features, such as node fairness, traffic load, and the age of data packets to find the best node-pair. In addition, the sender employs a list of candidates for node-pairs rather than path loss to reduce the computational complexity. The simulation results showed that the proposed scheme outperforms the conventional scheme by considering the fairness factor with 23.8% increases in throughput, 28% decreases in latency, and 5.7% improvements in fairness at best.

Uterotrophic Assay Using Ovariectomized Female Rats with Sub-cutaneous Administration

  • Kim, Hyung-Sik;Han, Soon-Young;Lee, Rhee-Da;Kil, Kwang-Sup;Park, Kui-Lea
    • Biomolecules & Therapeutics
    • /
    • v.8 no.1
    • /
    • pp.78-83
    • /
    • 2000
  • The objective of this study was to prevalidate the Organization for Economic Cooperation and Development's (OECD) rodent uterotrophic assay as a test method for screening of potential endocrine disrupting chemicals (EDCs). This study was conducted exactly as described in the OECD protocol documents. A positive control substance, 17$\alpha$-ethinyl estradiol (EE), was administered daily for three days to ovariectomized (OVX) Sprague-Dawley rats at various doses for determine the dose-response curve. Additionally, a pure antiestrogenic chemical, ZM189, 154 was administered to OVX rats at the same time EE to determine the effectiveness of the material against blocking the estrogenic effects of EE. At higher concentration of EE (10 $\mu\textrm{g}$/kg), a statistically significant difference in body weight gain and food consumption was observed compared to vehicle controls. In uterine responses, EE produced a dose-related increase in uterus weights compared to vehicle control. These increases were statistically significant at the >1.0 $\mu\textrm{g}$/kg doses. However, a similar dose-response relationship was not observed in vagina weight. A comparison of the two groups receiving ZM189,154 (0.1 and 1.0 mg/kg) with 0.3 $\mu\textrm{g}$/kg of EE and the group receiving only 0.3 $\mu\textrm{g}$/kg of EE showed dose-related decreases in uterus weights. However, statistical significance was shown in 1.0 mg/kg of ZM189,154. In conclusion, administration of EE produced a dose-related increase in uterine (wet and blotted) weights. Additionally, the 1.0mg/kg dose of ZM189,154 was effective in blocking the estrogenic activity of EE. These data suggest 3-day uterotrophic assay using OVX rats may serve as a good tool for EDCs screening.

  • PDF

A Nested Case Control Study on Risk Factors for Coronary Heart Disease in Korean (관상동맥질환 위험요인 구명을 위한 코호트내 환자-대조군 연구)

  • Kim, Ki-Soon;Park, Jong;Park, Jong-Ku;Kim, Chun-Bae;Chun, Byung-Yeol;Lee, Tae-Yong;Lee, Kang-Sook;Lee, Duk-Hee;Koh, Kwang-Wook;Jee, Sun-Ha;Suh, Il;Ryu, So-Yeon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.2
    • /
    • pp.149-156
    • /
    • 2001
  • Objective : To elucidate risk factors for coronary heart diseases among Korean males. Methods : A nested case control study was conducted among a Korea Medical Insurance Cooperation(KMIC) cohort composed of 108,802 males. The eases included 246 male patients who were admitted to hospital due to coronary heart diseases from 1993 to 1997 (120-25 by ICD) and whose diagnosis was confirmed by the protocol by WHO MONICA Project(1994). The control group was composed of 483 patients selected by frequency matching considering age and resident area from an inpatient care group without coronary heart disease during the same period. For study cases and the controls, the results of a health check-up in 1990 and a questionnaire on life style in 1992 were received through the KMIC. Some additional information was collected by telephone interviews during October 1999. Results : Multiple logistic regression analysis showed that the odds ratio(OR) of coronary heart diseases among past smokers and current smokers as compared to non-smokers were 1.94(95% CI : 1.14-3.31) and 2.20(55% CI : 1.35-3.59), respectively. The OR among persons who drank 4 cups or more of caffeinated beverages such as coffee or tea daily as compared to persons who drank one cup for 2-3 days was 2.50(95% CI : 1.07-6.12). The OR among persons with high normal BP and stage 3 hypertension against normotension were 2.51 (95% CI : 1.44-4.37) and 5.08(95% CI : 2.38-10.84). The OR among persons whose blood cholesterol were 240 mg/dL or mere against lower than 200mg/dL was 2.24(95% CI : 1.43-3.49). Conclusion : Smoking, drinking of excessive caffeinated beverages, hypertension and high blood cholesterol were proven to be significant risk factors for coronary heart diseases among Korean males.

  • PDF

Improved Cryopreservation Using Droplet-vitrification and Histological Changes Associated with Cryopreservation of Madder (Rubia akane Nakai)

  • Yi, Jung-Yoon;Sylvestre, Isabelle;Colin, Myriam;Salma, Mohammad;Lee, Sok-Young;Kim, Haeng-Hoon;Park, Hong-Jae;Engelmann, Florent
    • Horticultural Science & Technology
    • /
    • v.30 no.1
    • /
    • pp.79-84
    • /
    • 2012
  • An efficient protocol for cryopreservation of madder hairy root cultures has been developed using droplet-vitrification. In previous study, combining loading solution C4 (35% PVS3) and vitrification solution B5 (80% PVS3) was the most effective method. In this study, we tried three types of vitrification solution, B5, A3 (90% PVS2, on ice), and A5 (70% PVS2, on ice). Combining loading solution C4 and vitrification solution A5 (on ice) showed the best regeneration rate in this study. Histological changes of the cells within the hairy root of madder were also observed in different steps. The cells from the hairy roots of the control treatment were full and intact with different size of vacuoles and obvious cell nucleus having a dark nucleolus. After the stage of preparing for cryopreservation (after preculturing, loading, followed by dehydration solution A5 or B5), intercellular spaces had become distinct, and within cells, the cytoplasms had become denser and week plasmolyses had appeared. The cell plasmolyses were much more apparent and we measured the degree of plasmolysis by calculating, the area of cell/the area of cytoplasm. The value of plasmolysis degree was the highest in the combination of preculture, loading solution C4, and dehydration solution A5, 1.97. Because the highest regeneration rates appeared in the treatment of A5 for 20 min, we could assume that the optimal degree of plasmolysis for cryopreservation might be around 1.97. The changes in cell structure during cryopreservation might be a useful basis for the development of a proper long-term preservation method for madder germplasms.

MANET Certificate Model Using Distributed Partial-Certificate with Cooperation of Cluster Member Node (MANET 환경 하에서 멤버 노드간의 협력에 의해 분산된 인증서를 이용한 인증서비스에 관한 연구)

  • Lee, Dae-Young;Song, Sang-Hoon;Bae, Sang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.1
    • /
    • pp.206-215
    • /
    • 2007
  • Ad-Hoc network technology is a mobile internet technology of the future that will be used widely not only in Mobile Network but also in Wireless Personal Area Network (WPAN) and Ubiquitous Network For this to occur, distributed routing protocol design, loop prevention for link information reduction in overhead for control messages and route restoration algorithm must be improved or complemented. Security techniques that can guarantee safe com-munication between Ad-Hot nodes net also be provided. This study proposes and evaluates a new authentication mechanism for MANET. The mechanism segregates the roles of certification authority to keep with the dynamic mobility of nodes and handle rapid and random topological changes with minimal over-head. That is, this model is characterized by its high expandability that allows the network to perform authentication service without the influence of joining and leaving nodes. The efficiency and security of this concept was evaluated through simulation.

Performance Evaluation of LTE-VPN based Disaster Investigation System for Sharing Disaster Field Information (재난사고 정보공유를 위한 LTE-VPN기반 현장조사시스템 성능평가)

  • Kim, Seong Sam;Shin, Dong Yoon;Nho, Hyun Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.602-609
    • /
    • 2020
  • In the event of a large-scale disaster such as an earthquake, typhoon, landslide, and building collapse, the disaster situation awareness and timely disaster information sharing play a key role in the disaster response and decision-making stages for disaster management, such as disaster site control and evacuation of residents. In this paper, an exited field investigation system of NDMI (National Disaster Management Research Institute) was enhanced with an LTE-VPN- based wireless communication system to provide an effective on-site response in an urgent disaster situation and share observation data or analysis information acquired at the disaster fields in real-time. The required performance of wireless communication for the disaster field investigation system was then analyzed and evaluated. The experimental result for field data transmission performance of an advanced wireless communication investigation system showed that the UDP transmission performance of at least 4.1Mbps is required to ensure a seamless video conference system between disaster sites. In addition, a wireless communication bandwidth of approximately 10 Mbps should be guaranteed to smoothly share the communication and field data between the survey equipment currently mounted on the survey vehicle.

Importance awareness and Compliance on Patient Safety for Nurses Working in Operating Rooms (수술실간호사의 수술환자 안전관리에 대한 중요성인지도와 실천이행도)

  • Kim, Joung-Soon;Kim, Ju-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5748-5758
    • /
    • 2011
  • The purpose of this study was to evaluate the perceived patient safety, type of errors related to patient safety, importance awareness and compliance on patient safety for operating room nurses and to identify factors influencing compliance. Data were collected using a structured questionnaire from 191 perioperative nurses. Data were analyzed using descriptive statistics, t-test, paired t-test, ANOVA, Pearson correlation coefficients, and multiple regression. The perceived patient safety score was 6.3 as moderate level. Types of errors were mostly happened in patient injury (39.8%), counts (18.4%) and infection control (17.5%). The level of compliance on patient safety was significantly lower than that of importance awareness (t=18.01, P<.001). Compliance on patient safety showed significantly positive correlations to importance awareness (r=.56, p<.001). Experience of patient safety education, experience of errors in colleague, job position and working experience in hospital explained 13.9% of variance compliance on patient safety(F=8.407, P<.001). In conclusion, Hospital should develop education program related to patient safety, encourage nurses to manage safety protocol and ensure cultivating patient safety culture in the perioperative practice setting.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

A Study on Design of Agent based Nursing Records System in Attending System (에이전트기반 개방병원 간호기록시스템 설계에 관한 연구)

  • Kim, Kyoung-Hwan
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.2
    • /
    • pp.73-94
    • /
    • 2010
  • The attending system is a medical system that allows doctors in clinics to use the extra equipment in hospitals-beds, laboratory, operating room, etc-for their patient's care under a contract between the doctors and hospitals. Therefore, the system is very beneficial in terms of the efficiency of the usage of medical resources. However, it is necessary to develop a strong support system to strengthen its weaknesses and supplement its merits. If doctors use hospital beds under the attending system of hospitals, they would be able to check a patient's condition often and provide them with nursing care services. However, the current attending system lacks delivery and assistance support. Thus, for the successful performance of the attending system, a networking system should be developed to facilitate communication between the doctors and nurses. In particular, the nursing records in the attending system could help doctors monitor the patient's condition and provision of nursing care services. A nursing record is the formal documentation associated with nursing care. It is merely a data repository that helps nurses to track their activities; nursing records thus represent a resource of primary information that can be reused. In order to maximize their usefulness, nursing records have been introduced as part of computerized patient records. However, nursing records are internal data that are not disclosed by hospitals. Moreover, the lack of standardization of the record list makes it difficult to share nursing records. Under the attending system, nurses would want to minimize the amount of effort they have to put in for the maintenance of additional records. Hence, they would try to maintain the current level of nursing records in the form of record lists and record attributes, while doctors would require more detailed and real-time information about their patients in order to monitor their condition. Therefore, this study developed a system for assisting in the maintenance and sharing of the nursing records under the attending system. In contrast to previous research on the functionality of computer-based nursing records, we have emphasized the practical usefulness of nursing records from the viewpoint of the actual implementation of the attending system. We suggested that nurses could design a nursing record dictionary for their convenience, and that doctors and nurses could confirm the definitions that they looked up in the dictionary through negotiations with intelligent agents. Such an agent-based system could facilitate networking among medical institutes. Multi-agent systems are a widely accepted paradigm for the distribution and sharing of computation workloads in the scientific community. Agent-based systems have been developed with differences in functional cooperation, coordination, and negotiation. To increase such communication, a framework for a multi-agent based system is proposed in this study. The agent-based approach is useful for developing a system that promotes trade-offs between transactions involving multiple attributes. A brief summary of our contributions follows. First, we propose an efficient and accurate utility representation and acquisition mechanism based on a preference scale while minimizing user interactions with the agent. Trade-offs between various transaction attributes can also be easily computed. Second, by providing a multi-attribute negotiation framework based on the attribute utility evaluation mechanism, we allow both the doctors in charge and nurses to negotiate over various transaction attributes in the nursing record lists that are defined by the latter. Third, we have designed the architecture of the nursing record management server and a system of agents that provides support to the doctors and nurses with regard to the framework and mechanisms proposed above. A formal protocol has also been developed to create and control the communication required for negotiations. We verified the realization of the system by developing a web-based prototype. The system was implemented using ASP and IIS5.1.